You are on page 1of 1

SERV1783 - 104 -

04/04

AUXILIARY HYDRAULIC CONTROL


"B" SERIES SSL / MTL
INTERLOCK OVERRIDE / A2 ACTIVE
Worktool Control
Lever
Auxiliary Hyd.
(Proportional
Main or On / Off)
Key Start Switch Relay +8V

Auxiliary
Hydraulic ECM
Armrest A1 Switch / PWM Signal
Switch
A2 Switch / Press Switch
Seat Switch
+B

Park Brake Hydraulic Lockout/ Interlock Override


Switch Interlock Override Lamp
Switch

Door Switch

Aux. Hyd. Pressure Auxiliary Hydraulic


Release Switch Solenoid A1
Hydraulic
Lockout Lamp +B

Continuous Flow Auxiliary Hydraulic


+B Switch Engine Oil Press Switch Solenoid A2

88

The continuous flow and interlock override function allows the operator to continuously
operate the auxiliary hydraulic circuit without having to actuate the proportional or ON/OFF
switches. To enable the continuous flow function, the operator must first use the auxiliary
proportional or ON/OFF switches to the desired flow rate to the work tool. Once this rate has
been established, the tool is rotating at the desired speed, the operator must press and release
the continuous flow switch. The auxiliary proportional control or ON/OFF switch must be
returned to its NEUTRAL state within one second after the continuous flow switch has been
depressed. If the auxiliary proportional control or ON/OFF switch is not returned to its
NEUTRAL position within one second, the continuous flow command is ignored by the
Auxiliary Hydraulic ECM.

Once the continuous flow has been set, depressing and releasing the interlock override switch
activates the interlock override. This allows the operator to exit the machine and leave the
auxiliary hydraulic system activated.