NICE3000new(LKVF-06)别墅电梯参数设置表

parameter
Parameter name Synchronous machine setting Setting range Remarks
number
F0-03 maximum operating speed According to production order
F0-04 Elevator rated speed According to the host nameplate
F0-05 Elevator rated load According to production order
F1-00 Encoder type 0: SIN/COS incremental
F1-01 rated power According to the host nameplate kW
F1-02 Rated voltage According to the host nameplate V
F1-03 Rated current According to the host nameplate A
F1-04 Rated frequency According to the host nameplate Hz
F1-05 Rated speed According to the host nameplate rpm
F1-12 Number of encoder pulses According to the encoder nameplate 2048
F1-25 motor type 1: Synchronous motor
F5-01 X1 function selection 01: The upper leveling layer is normally open
F5-03 X3 function selection 02: Lower leveling normally open
F5-06 X6 function selection 38: Running output feedback normally closed
F5-07 X7 function selection 39: Brake output feedback normally closed
F5-09 X9 function selection 40: Inspection signal normally closed
F5-10 X10 function selection 09: Overhaul up normally open
F5-11 X11 function selection 10: Maintenance down normally open
F5-14 X14 function selection 48: Forced deceleration normally closed at level 1
49: The next level 1 forced deceleration normally closed
F5-15 X15 function selection
F5-17 X17 function selection 11: The building fire switch is normally open
F5-18 X18 function selection 58: Brake switch: feedback normally closed
F5-19 X19 function selection 58: Brake switch: feedback normally closed
F5-20 X20 function selection 27: ARD emergency operation
F5-21 X21 function selection 46: The machine is overloaded and normally closed
F5-22 X22 function selection 99: Motor overheating normally closed
F5-25 Car top input port selection 1856
F5-26 Y1 function selection 1: Run the contactor
F5-27 Y2 function selection 2: Brake contactor
0: Mainboard
F6-36 Weighing channel selection 1: Car top board switch input
switch input
F5-37 X25 function selection 4: Safety circuit signal
F5-38 X26 function selection 7: Hall door lock signal
F5-39 X27 function selection 5: Door lock loop signal
F6-00 Elevator top floor According to production order F6-01~31
F6-01 Elevator lowest floor According to production order 1~F6-00
F6-02 Parking base station According to production order F6-01~F6-00
F6-03 Fire base station According to production order F6-01~F6-00
F6-04 Elevator lock base station According to production order F6-01~F6-00
F6-05 Service Tier 1 According to production order 0~65535
F6-06 Service Tier 2 According to production order 0~65535
F8-01 Pre-torque selection 2: Pre-torque automatic compensation
F8-09 Power outage emergency rescue speed 0.050m/s
Power outage emergency rescue
F8-10 1: UPS running
options
F9-00 Idle time to return to base station 10min 0~240min
F9-03 Clock: Year current time 2000~2100
F9-04 Clock: month current time 1~12
F9-05 Clock: Day current time 1~31
F9-06 clock: hour current time 0~23
F9-07 clock: minutes current time 0~59
FB-00 Number of door operators According to production order 1~2
FB-02 Door operator 1 service floor 1 According to production order 0~65535
FB-03 Door operator 1 service floor 2 According to production order 0~65535
FB-04 Door operator 2 service floor 1 According to production order 0~65535
FB-05 Door operator 2 service floor 2 According to production order 0~65535
FB-11 Out door hold time 5s 1~30s
FB-12 Hold time inside the door 3s 1~30s

FB-13 Base station door open hold time 10s 1~30s