DATAR ENGINEERING

FUJI: VFD PARAMETER-


FOR HOIST APPLICATION - FUJI VFD
SR.NO. PARAMETER DESCRIPTION SET VALUE FACTORY SET
VALUE

1 F00 Data Protection 1 0


2 F02 Operation Method 1 2
3 F07 Acceleration Time 1 1 6
4 F08 Deceleration Time 1 0.5 6
5 F09 Torque Boost 1 2 6.8
6 F14 Restart Mode After Momentary 5 1
7 Power Failure(Mode Selection)

8 F15 Frequency Limiter(High) 50 70


9 F37 Load Selection /Auto Torque boost 2 1
10 F42 Drive Control Selection1 1 0
11 F50 BRAKE RESISTOR TEMP OFF 0
12 E03 Terminal X3 Function 10 2
13 E04 Terminal X4 Function 1009 3
14 E05 Terminal X5 Function 0 4
15 E06 Terminal X6 Function 100 5
16 E10 Acceleration Time 2 2 6
17 E11 Deceleration Time 2 0.5 6
18 E12 Acceleration Time 3 2 6
19 E13 Deceleration Time 3 0.5 6
20 E14 Acceleration Time 4 2 6
21 E15 Deceleration Time 4 0.5 6
22 E20 Terminal Y1 Function 37 0
23 E23 Terminal Y4 Function 38 0
24 E24 Terminal Y5A/C Function(Without Motor test-For Panel) 0 15
25 E24 Terminal Y5A/C Function(With Motor Site Perment) 57 15
26 E27 VFD OK CONDITION 10 99
27 E37 Current Detection 2/Low Current Detection (Level) As per Motor As per Motor
28 E38 Current Detection 2/Low Current Detection (Level) 3 10
29 E52 ALL PARAMETER ENABLE 2 0
30 C05 Multi Frequency1 50 0
31 C06 Multi Frequency2 20 0
32 C20 Jogging Frequency 20 0
33 P99 Motor 1 Selection 4 0
34 P02 KW
35 P03 Current
36 H98 Protection & Maintaince(Output/Input Phase Lose) 255 53
37 J68 Brake Signal(Brake-Off Current) 60 100
38 J70 Brake Signal(Brake-Off Timer) 0.5 1
39 J72 Brake Signal(Brake-On Timer) 0.5 1
40 J95 Brake Signal(Brake-Off Torque) 60 100
41 H03 FACTORY RESET Press-Stopkey+UP key---1 value