This document provides code numbers and settings for a 55 kW spinning machine frequency inverter. It lists default settings for motor specifications like voltage, frequency, current and pole number. It also lists acceleration/deceleration ramp settings and speed settings for 4 products in Hertz. The final step is to save the parameter settings by pressing various buttons on the inverter control panel.
Original Description:
Original Title
Inverter Setting for 55kw SIEI Inanam Spinning Machine
This document provides code numbers and settings for a 55 kW spinning machine frequency inverter. It lists default settings for motor specifications like voltage, frequency, current and pole number. It also lists acceleration/deceleration ramp settings and speed settings for 4 products in Hertz. The final step is to save the parameter settings by pressing various buttons on the inverter control panel.
This document provides code numbers and settings for a 55 kW spinning machine frequency inverter. It lists default settings for motor specifications like voltage, frequency, current and pole number. It also lists acceleration/deceleration ramp settings and speed settings for 4 products in Hertz. The final step is to save the parameter settings by pressing various buttons on the inverter control panel.
PMW 55 KW SPINNING MACHINE FREQUENCY INVERTOR SETTING
CODE NO SETTING DESCRIPTION REMARKS
d 000 drive output frequency in " hz " monitoring only d 001 drive frequency reference monitoring only d 002 drive output current in " ampere " monitoring only d 003 drive output voltage in " volt " monitoring only d 005 power factor monitoring only d 006 power using monitoring only d 100 digital input status monitoring only S 000 440 main voltage of main supply initial setting for motor S 001 50 base frequency of main supply initial setting for motor S 100 440 maximum voltage applied to the motor initial setting for motor S 101 50 rated frequency of the motor initial setting for motor S 150 97.9 rated current of the motor initial setting for motor S151 4 pole of motor initial setting for motor S 152 0.89 power factor of the motor initial setting for motor F 020 95 maximum frequency value initial setting for motor F 021 0 minimum frequency value initial setting for motor I 000 7 digital input 1 configuration do not change this value I 001 8 digital input 2 configuration do not change this value I 002 9 digital input 3 configuration do not change this value I 005 10 digital input 4 configuration do not change this value I 004 6 digital input 5 configuration do not change this value F 050 4 source of the reference 1 do not change this value F 051 0 source of the reference 2 do not change this value F 060 3 source of the multispeed 1 do not change this value F 061 3 source of the multispeed 2 do not change this value S 200 1 command source selection do not change this value S 201 60 maximum frequency reference do not change this value S 202 4 source of the reference 1 do not change this value F 200 2 acc/dec ramp setting do not change this value F 100 22.6 product no. 1 first speed with flip - flop all setting in " hz " F 101 31.9 product no. 1 second speed all setting in " hz " F 102 63.8 product no. 1 third speed all setting in " hz " F 103 91.7 product no. 1 fourth speed all setting in " hz " F 104 20.4 product no. 2 first speed with flip - flop all setting in " hz " F 105 28.9 product no. 2 second speed all setting in " hz " F 106 57.8 product no. 2 third speed all setting in " hz " F 107 85.5 product no. 2 fourth speed all setting in " hz " F 108 23 product no. 3 first speed with flip - flop all setting in " hz " F 109 32.5 product no. 3 second speed all setting in " hz " F 110 65 product no. 3 third speed all setting in " hz " F 111 96.1 product no. 3 fourth speed all setting in " hz " F 112 27.3 product no. 4 first speed with flip - flop all setting in " hz " F 113 31.5 product no. 4 second speed all setting in " hz " F 114 62.9 product no. 4 third speed all setting in " hz " F 115 93.1 product no. 4 fourth speed all setting in " hz " F 116 20 manual run speed all setting in " hz " F 201 / S 300 35 first step acceleration time all setting in " second " F 202 / S 301 10 first step deceleration time all setting in " second " F 203 35 second step acceleration time all setting in " second " F 204 10 second step deceleration time all setting in " second " F 205 35 third step acceleration time all setting in " second " F 206 10 third step deceleration time all setting in " second " F 207 40 fourth step / manual acceleration time all setting in " second " F 208 10 fourth step / manual deceleration time all setting in " second "
Final Step ( Save Parameter )
C 000 -> press E -> press up -> do ->press E -> done