Discussion

on

IS 3177:2020
Amendment
(Third Revision)
Mechanical

Prepared by:
Reva Industries India (P) Ltd. Amit Gupta
Key Amendments & major changes:

A. Recommended selection of group mechanism (duty class) of the crane for


purchaser.
B. Basic duty factor for class of mechanisms.
C. Selection of wheel and giving due consideration of duty class, travel speed
and wheel material.
D. Selection of sizes for wire rope, rope drum, sheave and allowable fleet
angle
E. Provision of compacted rope, seamless pipe for rope drum, case carburized
gearboxes, geared brake motor, etc
F. Motor selection with thermal adequacy, use of service factor and RMS
method.
G. The mechanism duty is classified in eight groups M1 to M8 based on their
total duration of utilization applying up to the time of replacement of
mechanism and load spectrum that is, life load cycle.
H. Supersede IS 4137: 2015 (EOT Cranes for steel work)

Note: Structural design aspects are covered in IS 807:2006


New classification of Cranes:

IS 3177: 2006

Note: The running time per day & total life relate to mechanism class only
Guidance for the Purchaser- Annex B:
Graphical method for calculating fatigue stress:
Wire Rope- Max allowable fleet angle : Graphical method
Wire Rope Min. Breaking force Calculation:

IS 3177 : 2006
Wire Rope Drum Diamter Calculation:

IS 3177 : 2006
Strength of Wire Rope Drum:

IS 3177 : 2006
Drum groove clearance:

IS 3177 : 2006
Sheave Diameter Calculation:
IS 3177 : 2006
Sheave Material & Grooving:
IS 3177 : 2006

NO GROOVING IN
IS 3177 : 2006
Wheel Hardness:
IS 3177 : 2006
Diameter of the Wheels (IS 3177:2020)
Diameter of the Wheels (IS 3177:2006)
Minimum Flange dimensions:
IS 3177 : 2006
Bearing life:
IS 3177 : 2006

No Bearing life is mentioned in


IS 3177 : 2006
Lubrication System:
IS 3177 : 2006
Line Shafting & coupling:
IS 3177 : 2006

No line shaft & coupling


mentioned in
IS 3177 : 2006
Selection of AC motor-Hoisting Motion:
IS 3177 : 2006

* Cdf factor Obsolete.


* Service fator table introduced
* Ambient temp. as per OEM
Service factor for AC motor:
Ambient temp. for AC motor:
IS 3177 : 2006
Selection of AC motor-CT & LT Motion:
Selection of AC motor-CT & LT Motion (IS 3177: 2006):
Speed tolerance & track tolerance: