CANH
CANL
ECM/PCM
U0073-0302
General Description
The controller area network (CAN) transmits/receives pulsing signals to/from the control modules simultaneously by using
two signal lines (CANH and CANL).
When the engine control module (ECM)/powertrain control module (PCM) does not receive the signals from the gauge con-
trol module via the CAN lines for more than a set time, the ECM/PCM detects a malfunction and a DTC is stored.
Sequence None
Enable Conditions
Condition Minimum Maximum
Malfunction Threshold
No signals from the gauge control module via the CAN lines are received for at least 1 second.
Diagnosis Details
Conditions for illuminating the MIL
When a malfunction is detected, the MIL comes on and the DTC and the freeze frame data are stored in the ECM/PCM
memory.