Professional Documents
Culture Documents
250
100
300
B - UNDER FREQUENCY
Power (KW)
1. SHUT OFF HEAD AT 51.5 Hz / 50 Hz / 47.5 Hz = 278 mlc. / 262 mlc. / 237 mlc.
100
2. INPUT POWERS AT B & C ARE CALCULATED BASED ON ACTUAL HEADS GENERATED AT 50Hz.
3. PUMP IS SELECTED FOR MAXIMUM PARAMETERS POINT 'A' i.e DESIGN CONDITION
50
4. SUCTION SPECIFIC SPEED (Nss)AT DESIGN CONDITION: 10881 US UNITS
90.0
5. Motor rating = 300 kW
Digitally signed by
80.0 2.5 * REFERENCE DOCUMENTS/ DRAWING NO. S.Biswas
DN: cn=S.Biswas,
A 1.DRIP PUMP SIZING CALCULATION BHEL-PEM DRAWING NO.PE-DC-445-100-N119
o=DCPL, ou=Power
Cell,
70.0
CB email=swarajb@in.dcl
group.com, c=IN
Date: 2022.05.25
60.0 2.1 09:58:53 +05'30'
Efficiency (%)
50.0
THE WEST BENGAL POWER DEVELOPMENT
CUSTOMER
CORPORATION LIMITED (WBPDCL)
40.0 1.7
CONSULTANT DDEVELOPMENT CONSULTANTS PRIVATE LIMITED (DCPL), KOLKATA
30.0
A JOB NO. : 445
DRG NO. HY-DG-445-181-A007
Altd:
20.0
51.5 Hz B 1.3 PROJECT
SAGARDIGHI THERMAL POWER EXTENSION PROJECT
Date: Chkd: PHASE III, UNIT 5 [1X660MW, SUPERCRITICAL]
50 Hz STATUS: CONTRACT
C NAME SIGN DATE
10.0
47.5 Hz PUMPS ENGINEERING
PRPD. RAJESH SD/- 03-03-2021
Rev 01 Altd: VKKR CHKD. AVINASH SD/- 03-03-2021
0.0 0.9 BHARAT HEAVY ELECTRICALS LTD. HYDERABAD
0 50 100 150 200 250 300 350 Date: 13.12.21 Chkd: CHR APPD. KHRK SD/- 03-03-2021
TITLE:
DRG NO. HY-DG-445-181-A007
Flow (m3/h) As per the comments received
REV 01
from DCPL and latest drawings DRIP PUMP ESTIMATED PERFORMANCE CURVES
SHEET NO: 1 NO. OF SHEETS: 1
BHEL/HYDERABAD (PUMPS ENGINEERING)
1X660MW SAGARDIGHI TPP EXT. UNIT 5
WBPDCL DRG NO:HY-DG-445-181-A007 R-00
DRG TITLE: ESTIMATED PERFORMANCE CURVE OF DRIP PUMP
DATE: 13.12.2021
Sl.No CUSTOMER COMMENTS on R-00 Dated: 30.04.2021 BHEL REPLY
1 Please check this points are not falling on pump H-Q curve (50 Hz). How can stable operation This curve is falling below the design curve so it in operating region. BHEL confirms that
of pump at this points be ensured ? Pump runs in stable operation. Since DRIP Pump is constant speed pump, it always operate
on Flow - Head (H-Q) Curve given. i.e. DRIP pump operates at Flow and actual head (HEAD
ACT.) given in table.
2 We understand that at best efficiency point pump should run at highest efficiency. Please Best efficiency point is the system condition given in sizing calculation. It is EMCR condition
check. of the system not DRIP Pump best efficiency point.
3 As per Notes-1 of Annexure-I V-IIC/S-III "Best Efficiency point should be at the rated discharge Best efficiency point is the system condition given in sizing calculation. It is EMCR condition
(design point), the efficiency during 100% TMCR operation shall not fall appreciably (more of the system not DRIP Pump best efficiency point.
than 2%) from the best efficiency value."
4 Please indicate rating of motor. As per cl. no. 4.03.07 of sec-III, vol-IIC, "Rating of the motor Indiacted inrevised drawing.
shall be selected with at least 10% margin over the maximum power required within the range
of operation".
5 Provide reference document number with Title description of BHEL-PEM Provided in revised drawing.
6 Please clarify significance of the column. Actual head (HEAD ACT.) is opearting Head of Drip pump. And DRIP Pump is constant speed
pump, it always operate on Flow - Head (H-Q) Curve given. i.e. DRIP pump operates at Flow
and actual head (HEAD ACT.) given in table.