Mention in Full texts "Best Please submit detailed sizing calculation of drive

Efficiency Point" Please clarify why these motor as per requirement of cl. no. 4.01.17 of sec-
figures are different from that III, Vol-IIC of specification.
of TD BFP
TOTAL
5071 mlc 4982 mlc SUCTION INT STG DISCHARGE INT. HEAD BFP INT. STG. MAX
HEAD MD BP
BFP+BP CONDITION FLOW FLOW FLOW TEMP (Deg C) SP. GR. (BFP+BP) SUCTION PR TAPOFF PR FLOW
(BFP+BP) HEAD (mlc)
(m3/hr) (m3/hr) (m3/hr) (mlc) (Kg/cm2)A (Kg/cm2)A (m3/hr)
(mlc)
A DESIGN POINT 1300 0.0 1300.0 3640 188.9 0.877 1151 29.01 114.95 170 1625
B BEP 1065 0.0 1065.0 3550 186.9 0.878 1132 29.34 112.98 179 1533
C EMERGENCY POINT 1175 0.0 1175.0 3900 188.9 0.877 1228 29.46 121.72 175 1631
D BMCR U/F 1245 0.0 1245.0 4060 187.9 0.878 1271 28.95 125.36 173 1678
D E RUNOUT POINT 1305 0.0 1305.0 2180 171.2 0.896 737 25.53 76.44 170 1351
C F HPBP POINT 775 0.0 775.0 3165 138.2 0.928 1029 22.94 100.96 188 1387
a

B MDBFP MDBFP MDBFP


MDBFP MDBFP MDBFP SHAFT POWER
MDBFP INT.
HEAD AT SHUT
A SHAFT NPSHR 3% FOR MOTOR SELECTION MIN. FLOW MIN RC OFF
BFP CONDITION HEAD EFFICIENCY SPEED HEAD (BFP)
POWER Head drop (KW) WITH MAX (m3/hr) FLOW HEAD
F (meter) % (RPM)
(kW) (mlc) EFFICIENCY 83%
[mlc]
(mlc) (mlc)
A DESIGN POINT 3469.5 84.7 5611 12728 58.6 12984 980 453 4383 4467
B BEP 3370.7 84.3 5303 10191 50.6 10345 952 428 3898 3968
C EMERGENCY POINT 3724.7 84.5 5629 12376 57.5 12376 1052 455 4414 4500
D BMCR U/F 3887.3 84.6 5796 13678 61.4 13945 1098 468 4668 4746
E RUNOUT POINT 2009.7 81.3 4670 7875 42.7 7714 567 377 3025 3079
F HPBP POINT 2976.6 81.3 4792 7176 39.8 7027 841 387 3189 3241
E NOTE :
1. HYDRAULIC COUPLING MAX OUTPUT SPEED @ 50Hz = 5810 RPM As per cl. no. 4.01.13 of sec-
2. HYDRAULIC COUPLING MAX OUTPUT SPEED @ 51.5Hz = 5984 RPM III, vol-IIC of specification,
3. MIN RC FLOW AT DESIGN CONDITION = 453 Cu.m/hr pump drive shall be rated for
w 4. MIN. RC FLOW INDICATED IS FOR BFP OPERATION. THIS IS INDICATED ONLY FOR THE PURPOSE OF CALCULATING BFP SET SHUT OFF PRESSURES AT RC FLOW. cold water application.
Provide reference document numberwith Title of BHEL-PEM Please also indicate min.
Please confirm that hyd. coup. max. output speed of hyd. coup.
speed @47.5 Hz shall be 5506 rpm, @47.5, 50.0 and 51.5 Hz.
D to achieve desired flow and head at
C A low frequency operation (at 47.5 Hz)
W

B
W

F
E
D
C
A
B
w
F
B C D A
F
E

W r
D
C As per cl. no. 4.01.06 of sec-
JOB NO. : 445 CUSTOMER: WBPDCL
A III, vol-IIC, BHEL shall
ensure that NPSH (A) at
y %

PROJECT: 1X660MW SAGARDIGHI STEP


design point with lowest
B deaerator level and STATUS: CONTRACT DEVELOPMENT CONSULTANTS PVT LTD.
%

maximum pressure drop CONSULTANT


KOLKATA
F across the strainer shall be
E at least 2.5 times the NPSH
(R) at 3% head drop for PUMP
MDG406
main pump.
MODEL
DRG NO. HY-DG-445-180-A008
Necessary calculation to be
submitted to validate above. PUMPS ENGINEERING NAME SIGN DATE
PRPD. RAJESH CH -- 22.02.21
BHARAT HEAVY ELECTRICALS LTD. HYDERABAD CHKD. AVINASH -- 22.02.21
APPD. AVINASH -- 22.02.21
TITLE
DRG. NO. HY-DG-445-180-A008 REV. NO.
w ESTIMATED PERFORMANCE CURVES OF MD BOILER
FEED PUMP SHEET NO: 1 OF 1 0