DESIGN/BUILDER:

OUR BUSINESS IS BUILDING YOURS

LaMACCHIA
GROUPAL

PLAN v DESIGNr BUILD' PEOPLE


157 North Milwaukee Street
Milwaukee, Wisconsin 53202
T 414.223.4400 F 414.223.4488
www.Iamacchiagroup.com

1-112" CW, SEE CIVIL


PLANS FOR ACTUAL
LOCATION

25.51
H
1 WATER
METER

4" VTR
~JAiG~V HB-1
ET-1 Fi4
IN

FD-1
N~
K IC. N

14727 VICTOR HUGO BLVD. N.


MB-1
DI3I- -3
I WH-1 22.5
N
N

N L-1
I
1-114
N

HEARTLAND CREDIT UNION


NN
"Soo
L-1 X"N N
N

N E-2 w- I~ FD-1 w
314V
N
N
NN.
N%
N -'-- L TWC-1A
_- - DI
MB-1 I 4.5 I
314"
18
S-1
L2 I- 18
LAY
F 3N
10 '00 RV1
F2
L-1
L-1
6 iNN EL FD-1 WC-1A
N EL EL WCO Li EL5

HUGO, MN 55038
N,'-
-
DW

-
WC-1A WC-1A
LI-5
N
4 ET1 S-1 F5
t3Z N,
N%
N
-

K IN,
N
N
N
4" WASTE PIPING,
SEE CIVIL PLANS FOR
loo

BEV N ACTUAL LOCATIONS


N
zrE2 EL
28 N NOTES:
1. 1-1/2 WATER METER WITH BYPASS, INSTALL PER CITY OF BIG
LAKE UTILITY DEPARTMENT STANDARDS. SEE CIVIL DRAWINGS
FOR ACTUAL WATER METER AND BACKFLOW PREVENTER
LOCATION.
<
2. PROVIDE SINK P-TRAPS AND WATER SUPPLIES TO ADA TO BE
INSULATED WITH FULLY MOLDED FLEXIBLE VINYL
INSULATION THAT CONFORM TO ADA REQUIREMENTS.
3. PROVIDE ALL FLOOR DRAINS WITH TRAP PRIMERS. THE CONSTRUCTION DOCUMENTS CONSIST OF BOTH
NOTE:
4. PROVIDE SINK AND LAVATORIES WITH THERMOSTATIC MIXING THE INFORMATION ON THIS DRAWING AND THE
BEV VALVES.
1. CIRCUIT AND COMMON VENTING ARE USED IN LIEU OF INDIVIDUAL FIXTURE VENTING. SPECIFICATION MANUAL. IF THE DOCUMENTS HAVE
10 -7 5. WATER HAMMER ARRESTORS:
2. PROVIDE ALL FLOOR DRAINS WITH TRAP PRIMERS. TRAP PRIMERS SHALL HAVE AN HB-1 CONFLICTING INFORMATION CONTRACTOR SHALL
-HORIZONTAL LESS THAN 20' LONG, PROVIDE ONE WHA AT END
ASSE 1013 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER; OR AN ASSE OF LINE. NOTIFY THE ARCHITECT IMMEDIATELY FOR
F4
1020 PRESSURE BREAKER; AN ASSE 1056 SPILL PROOF VACUUM BREAKER WITH NO -IF BRANCH MORE THAN 20' LONG, PROVIDE ANOTHER WHA IN CLARIFICATION.
SHUT-OFF VALVE DOWNSTREAM. TRAP PRIMERS WITH INTREGRAL BACKFLOW 01
COFFEE THE MIDDLE SIZED FOR HALF THE FIXTURE UNITS.
PREVENTION ARE ONLY WHEN EQUIPPED WITH ONE OF THE ABOVE LISTED F .5
BACKFLOW PREVENTERS. L)PI1 WSFU TOTAL FIXTURE UNITS NO. DATE BY DESCRIPTION
X I WATER LINE SIZE
FIXTURE UNITS
D1 WASTE UNE SIZE

A _

A _

A _

WASTE AND VENT PIPING ISOMETRIC DOMESTIC COLD AND HOT WATER ISOMETIC A
1I / NTS 2 / NTS
_

A _

A _

A _

PLUMBING FIXTURE ROUGH-IN SCHEDULE


A _

ROUGH-IN LA MACCHIA GROUP PROJECT NUMBER:

MN-HRT-1901
TAG FIXTURE
COLD HOT WASTE VENT
L-1 LAVATORY 1/2" 1/2" 1-1/2 1-1/2
DATE:

2/21/2020
WC-1 WATER CLOSET 1/2" - 3 2
WC-1A WATER CLOSET 1/2" - 3 2
UR-1 URINAL 1-1/4" - 2 1-1/2 SHEET TITLE:

S-1 BREAK ROOM SINK-1 1/2" 1/2" 1-1/2 1-1/2 ISOMETRICS


MB-1 MOP SINK 3/4 3/4 3 1-1/2
FD-1 FLOOR DRAIN - - 3 1-1/2

SHEET NUMBER: COPYRIGHT ©


LA MACCHIA GROUP, LLC.

P-200
All information contained on this drawing
including, but not limited to design concepts
and details is the property of La Macchia
Group, LLC. All ideas documented herein were
created for this specific project and shall not be
reused in any form without the written permission
of La Macchia Group, LLC.