A B C

10000
2000 4000 4000
SEE FENCING
DETAILS 2000 2000

C3-F3 C1-F1 FTB-1 C1-F1 FTB-1 C1-F1


1

CHASE
PIPE
LANDING

2500
WF-1
14

3333.33
WF-1
WF-1

13 15
4000

12 16
SLAB ON FILL T= 125mm THK.
11
SPACED @ 400mm ON CENTER WF-1
10 BOTHWAYS & 100mm THK.
9 LANDING GRAVEL BEDDING.

C3-F3 8
C2-F2 FTB-1 C2-F2 FTB-1 C2-F2

WF-1
2

7
1
6
2
5

4
WF-1 WF-1

FTB-1
3

3333.33
10000
WF-1

FTB-1

FTB-1

C3-F3 C2-F2 C2-F2 C2-F2


13500
3

6000

FTB-1 FTB-1
FENCING/ PROPERTY LINE

3333.33
FTB-1

FTB-1

FTB-1
WF-1

C3-F3 FTB-1 FTB-1


4

C1-F1 C1-F1 C1-F1


FTB-1

FTB-1

FTB-1
WF-1

3500
3500

C3-F3 WF-1 C3-F3 FTB-1 C3-F3 C3-F3 C3-F3


RAMP

FTB-1 SEE FENCING


DETAILS
4000 4000

FOUNDATION PLAN
SCALE: 1:100