200PRV Valve

Installation and Operation Instructions


Troubleshooting Guide
200PRV Fall-Off Characteristics
Reduced pressure fall-off is inherent to direct acting regulators and a key factor relating
valve characteristics to system requirements. Fall-off is the difference between the static and
dynamic pressures downstream of the regulator. It varies with flow and represents the pres-
sure change that occurs when the valve opens.

The following chart depicts the fall-off characteristics of the 200PRV. The zero point repre-
sents the valve when there is no flow (valve in lock-up condition) and can be any setting
within the outlet pressure adjustment range. As water flows through the open valve, fall-off is
the dynamic pressure reduction associated with a given flow.

Example: The regulator is set at 60 psi (4,2 bar) static outlet pressure. If a downstream con-
trol valve opens and water flows at 80 gpm (18,2 m3/h; 5,1 l/s), the fall-off will be approxi-
mately 10 psi (0,7 bar) making the dynamic outlet pressure approximately 50 psi (3,5 bar).

20 1.2
Fall-Off (Bar)

15 0.9
Fall-Off (PSI)

10 0.6

5 0.3
Rain Bird Corporation Rain Bird Corporation Rain Bird International, Inc.
0 0 Contractor Division Commercial Division 145 North Grand Avenue
0 20 40 60 80 100 120 0 5 10 15 20 25 970 West Sierra Madre Avenue 6991 East Southpoint Road Glendora, CA 91741 USA
Flow (GPM) Flow (m3/hr) Azusa, CA 91702 Tucson, AZ 85706 Phone: (626) 963-9311
Phone: (626) 963-9311 Phone: (520) 741-6100 Fax: (626) 963-4287
Fax: (626) 812-3411 Fax: (520) 741-6522
1.2 www.rainbird.com
Rain Bird Technical Services Specification Hotline
Fall-Off (Bar)

0.9 (800) 247-3782 (U.S. only) (800) 458-3005 (U.S. only)


0.6

0.3
® Registered trademark of Rain Bird Corporation
0 Rain Bird. Conserving more than water. ® 2002 Rain Bird Corporation 2/02 P/N 232153
0 2 4 6
Flow (l/s)
4
English 200PRV Valve Troubleshooting Guide lower the outlet pressure setting, and
verify that the inlet pressure is at least
Thank you for purchasing a Rain Bird • The PRV is a normally open valve. It is Difficulty adjusting valve to 15 psi (1 bar) above the desired out-
200PRV valve. When a pressure reduc- not a control valve. Rain Bird recom- desired outlet pressure. let pressure.
ing valve is desired for commercial irri- mends at least one on/off control • Verify that the inlet pressure is at least
gation purposes, Rain Bird’s PRV pres- valve before and/or after the PRV. 15 psi (1 bar) above the desired out- Water leaks from inlet or outlet 3
sure regulator provides quality, perfor- Install a shut-off valve upstream of the let pressure. threads.
mance and economy. This normally PRV so water can be conveniently • Attempting to adjust the outlet pres- • Valve is not properly tightened on D
open valve designed for point-of-con- turned off if the regulator needs ser- sure when the inlet pressure is too low mating pipe threads. Re-tighten valve E
nection applications is rugged and reli- vicing. can cause the valve spring to connections or re-connect valve to
able. By reducing high inlet pressures • This valve should only be used on irri- become fully compressed. This may line according to installation
to lower outlet pressures, the PRV gation systems and should be deform and permanently damage the instructions.
improves irrigation system performance installed downstream of the backflow bonnet, thereby causing external • Threads are damaged by cross-
and conserves water. prevention device (according to local leaks. C
threading or contaminated by debris.
code). Inspect threads and repair or clean as
NOTES • Proper operation requires inlet pres- With no downstream flow, the needed.
• The PRV is shipped in a globe config- sure to be a minimum of 15 psi (1 bar) outlet pressure increases to
uration and is designed for globe higher than desired outlet pressure. equal the inlet pressure. Low or inadequate flow
installation/operation only. • Lock-up pressure is not in effect. The condition.
valve seat cannot fully close against • System gate or master valve is not B 7
the valve body throat. fully open. Locate the gate or master
Installation Refer to F1. 4. Ensure inlet side is connected to • Check to see if there is debris lodged valve and open.
1. Flush main line thoroughly before main line. Note arrows on valve body between the seat and the body throat.
indicating direction of water flow. • Obstruction in the main pipeline.
installing the valve. • Check to see if the seat is damaged. 2
2. Use two wraps of Teflon tape along Schrader valve ● C should be on the Isolate obstruction and remove.
downstream side of the valve. • Water pressure is being used else-
the full length of the inlet and outlet Water leaks from the top of the
5. After installing the valve, slowly open where on the site. Too many down-
pipe threads. Do not apply pipe bonnet, near the handle.
the water supply at point-of-connec- stream control valves and sprinklers
thread or pipe dope compound. • Loose diaphragm lock nut. Remove A
tion. Remember this is a normally operating at one time. Do not exceed
3. Thread inlet pipe into the inlet port of the bonnet and tighten the nut to 25 maximum flow capabilities.
the valve ● A and hand tighten. open valve and water will continue to inch-pounds of torque. 5
Thread outlet pipe into the outlet port flow unless an on/off control valve is • Torn or damaged diaphragm. Replace
F1
Technical Questions:
of the valve ●B and hand tighten. in place downstream. the diaphragm.
6. For dirty water systems be sure to • Inside the U.S., please call Rain Bird
Tighten with wrench but do not
install a 100 mesh (or finer) WYE filter Technical Services at (800) 247-3782
exceed two turns beyond hand tight. Water leaks from between the
or screen filter before the PRV valve. or the Rain Bird Spec Hotline at (800)
body and the bonnet. 458-3005.
• Bonnet retaining screws are loose. • Outside the U.S., please refer to the
Re-tighten the screws. back page for contact information.
Operating Instructions When the outlet pressure is at the
• Valve spring is compressed to solid
desired setting, remove the pressure • Visit www.rainbird.com
The valve comes from the factory pre- gauge from the valve stem and tighten height by attempting to set the outlet
set at 60 psi (4,1 bar) static outlet pres- the screw on the valve handle to lock-in pressure too high. Turn the adjust-
sure. To change the outlet pressure set- the setting. ment handle counter-clockwise to
ting, loosen the screw on the top of the 1
valve handle ● D by turning one turn
counter-clockwise. Connect a pressure Replacement Parts Refer to F2.
Operating Range:
hose gauge to the Schrader valve stem 200PRV 200PRV
Pressure: up to 200 psi (13,8 bar)
●C located just above the outlet port of Regulation: 25 to 85 psi (1,7 bar to 5,9 bar) 1 Poppet/Seat/Plunger Assembly 232295 5 O-Ring, Body 232299
the valve ●B . Turn the handle ● E Accuracy: + 5 psi (0,3 bar) 2 Diaphragm 232296 6 O-Ring, Plug 232300
6
counter-clockwise to decrease the out- Flow: up to 120 GPM (27,3 m3/h; 7,6 l/s) 3 Bonnet Screws 232297 7 Locknut 204968 F2
let pressure setting, or clockwise to Water temperature: up to 110° F (43° C) 4 Handle Screw 232298
increase the outlet pressure setting.