You are on page 1of 6

Report Number : GUAT23003222

Intertek de Guatemala, S.A.


46 calle 21-53 zona 12, Expobodegas Petapa 46,
Ofibodega #10, Guatemala City 01012, Guatemala, PBX: +502 2303 5800
TEST REPORT

NUMBER : GUAT23003222
DATE : 13-Feb-2023

APPLICANT : Coval S.A. de C.V


Coval S.A. de C.V, Ilopango, San Salvador, El Salvador
ATTN : Osmin Valencia

Sample Description : FTAR3350/737BMFPOL14 FRENCH TERRY


Agent: Victor Montalvo
Vendor : Coval S.A. de C.V.
Fiber Content : 86% Polyester 14% Spandex
Color : White (APSWHI-10S)
Style No. : 6201
P.O. Number : 1192
Article No : Not Provided
Lot No. : Not Provided
Buyer : AVAUS GROUP/ Iron Joc
Manufacturer's Name : GAMA TEXTILES S.A.
Material : Fabric
End Use : Hoodies/ Men's and Women's Wear
Fabric Weight : 250 g/m2
Construction : French Terry

APPLICANT PROVIDED CARE INSTRUCTIONS :


Machine wash warm do not bleach tumble dry low do not iron do not use softener
Date Received/Date Test Started : 02 Feb 2023
Date Confirmation Received : -

TEST CONDUCTED : AS PER THE REQUEST OF THE APPLICANT. FOR FURTHER DETAILS PLEASE
REFER TO ENCLOSED PAGE(S)

AUTHORIZED BY
FOR Intertek de Guatemala, S.A. [Guatemala]

RUDY SEMRAU REPORTES GUATEMALA


GENERAL MANAGER
1. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. 2. Our report
includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from the date of issuance of this report to
notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise.
TEST REPORT
NUMBER : GUAT23003222
DATE : 13-Feb-2023

CONCLUSION :
xxxxxxxx
Fiber Content M
Dimensional Change After Laundering D
Skew Change After Laundering D
Fabric Weight M
Bursting Strength D
Pilling Resistance: Martindale Tester M
Stretch Properties of Knitted Fabrics M
Water Repellency: Spray Test F
Assessment of Antibacterial Finishes on Textile Materials M

NOTE: M = Meet Buyer's Requirement F = Below Buyer's Requirement


* = See Remark C = Conform Label
N/A = Not Applicable D = Data

1. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. 2. Our report
includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from the date of issuance of this report to
notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise.
A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents.
Our results are based in a Simple Acceptance Decision Rule according to Client’s requirements.

Intertek de Guatemala, S.A. Page 2 of 5


46 calle 21-53 zona 12, Expobodegas Petapa 46,
Ofibodega #10, Guatemala City 01012, Guatemala, PBX: +502 2303 5800
TEST REPORT
NUMBER : GUAT23003222
DATE : 13-Feb-2023

TEST CONDUCTED (AS REQUESTED BY THE APPLICANT)


1. Fiber Content
- AATCC TM20-2021 / AATCC TM20A-2021. Moisture regain based on ASTM D1909 - 13(2020)e1.
Requirement
Submitted Fiber Content: 86% Polyester 14% Spandex
Lab Analysis: 88.0% Polyester 12.0% Spandex +/-3%
Recommended Fiber Content: 86% Polyester 14% Spandex

2. Dimensional Change After Laundering


- AATCC TM135-2018t : Machine wash at 105°F normal cycle, 1993 AATCC powder detergent, followed by tumble dry
delicate cycle
Requirement
Length: -2.9 -
Width: -0.8 -

3. Skew Change After Laundering


- AATCC TM179-2019, Method 1, Option 1 : Machine wash at 105°F normal cycle, 1993 AATCC powder detergent,
followed by tumble dry delicate cycle
Requirement
Skew change (%): 0.8 -

4. Fabric Weight
- ASTM D3776/D3776M - 20
Requirement

g/m² oz/yd² Deviation from Claim (%) blank


Average: 262.5 7.74 +5 250 g/m2 (+/-5%)

5. Bursting Strength
- ASTM D3786/D3786M - 18
Requirement
Average (psi): **No burst -
at 32.0
REMARK:
**No burst due to the stretch of the fabric exceeds the dimensional limitations of the equipment.

1. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. 2. Our report
includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from the date of issuance of this report to
notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise.
A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents.
Our results are based in a Simple Acceptance Decision Rule according to Client’s requirements.

Intertek de Guatemala, S.A. Page 3 of 5


46 calle 21-53 zona 12, Expobodegas Petapa 46,
Ofibodega #10, Guatemala City 01012, Guatemala, PBX: +502 2303 5800
TEST REPORT
NUMBER : GUAT23003222
DATE : 13-Feb-2023

6. Pilling Resistance: Martindale Tester


- ASTM D4970/D4970M - 16 e3
Requirement
After 1,000 rubs Average: 5 5

7. Stretch Properties of Knitted Fabrics


- ASTM D2594/D2594M-21
Stretch:
Requirement
Wales direction: 76% -
Courses direction: 42% -
Growth - 1 min recovery period:
Requirement
Wales direction: 2% -
Courses direction: 6% -
Growth - 1 hr recovery period:
Requirement
Wales direction: 1% 5% max.
Courses direction: 3% 5% max.
Recovery - 1 min recovery period:
Requirement
Wales direction: 95% -
Courses direction: 90% -
Recovery - 1 hr recovery period:
Requirement
Wales direction: 97% 85% min.
Courses direction: 94% 85% min.

8. Water Repellency: Spray Test


- AATCC TM22-2017e
As Received:
Requirement
Specimen 1: 80 100
Specimen 2: 80 100
Specimen 3: 80 100

1. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. 2. Our report
includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from the date of issuance of this report to
notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise.
A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents.
Our results are based in a Simple Acceptance Decision Rule according to Client’s requirements.

Intertek de Guatemala, S.A. Page 4 of 5


46 calle 21-53 zona 12, Expobodegas Petapa 46,
Ofibodega #10, Guatemala City 01012, Guatemala, PBX: +502 2303 5800
TEST REPORT
NUMBER : GUAT23003222
DATE : 13-Feb-2023

9. Assessment of Antibacterial Finishes on Textile Materials


- AATCC TM100-2019. -
Test Organism: - Staphylococcus aureus (ATCC 6538)
- Klebsiella pneumoniae (ATCC 4352)
Tested Specimen: Five/Six test specimens of 4.8 cm diameter per trial
Sterilization Of Sample Before Test: No
Inoculum Carrier: Tryptic soy broth 5%
Contact Time: 24 hours
Neutralizing Solution: Dey/Engley Broth
Solid Medium for Enumeration: Tryptic soy agar
Incubation Time: 24 hours
Incubation Temperature: 37°C
Staphylococcus aureus Klebsiella pneumoniae Requirement

- Inoculum initial count: 1.4E+05 CFU/mL 2.5E+05 CFU/mL


- Number of bacteria recovered 1.0E+05 CFU/ Sample 2.5E+05 CFU/ Sample 99.6%
from treated sample
immediately after inoculation
(C):
- Number of bacteria recovered 1.0E+02 CFU/ Sample 1.0E+02 CFU/ Sample
from treated sample after 24
hours contact time (A):
- Number of bacteria recovered 2.3E+07 CFU/ Sample 3.7E+07 CFU/ Sample
from viability control after 24
hours incubation time:
- Reduction of bacteria in >99.9% >99.9%
percentage (R) (R= 100*(C-
A)/C):

## END OF THE TEST REPORT ##


This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any
particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Addressee in respect of this report and only
accepts liability to the Addressee insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no
warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the
Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute.

http://www.intertek.com/terms.

1. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. 2. Our report
includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from the date of issuance of this report to
notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise.
A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents.
Our results are based in a Simple Acceptance Decision Rule according to Client’s requirements.

Intertek de Guatemala, S.A. Page 5 of 5


46 calle 21-53 zona 12, Expobodegas Petapa 46,
Ofibodega #10, Guatemala City 01012, Guatemala, PBX: +502 2303 5800

You might also like