You are on page 1of 1

REMOTE CONTROL SYSTEM (COMBINATOR) FAILURE

MAINE ENGINE AND CPP

ACTION BY BRIDGE ACTION BY MCR ACTION BY ENGINE ROOM


INFORM BRIDGE ABOUT
CONTROL FAILURE:
“CONTROL FAILURE IN ----
ENGINE, REQUEST HAND
OVER CONTROLS IN MCR”
HANDS OVER INFORMS BRIDGE:
CONTROLS TO MCR:
“HANDING OVER “CONTROLS IN MCR,
CONTROLS TO ENGINE NOT RESPONDING
MCR, NOW , IN MCR, CHANGING OVER
NOW,TAKE OVER” TO NFU MODE”

INFORMS MCR: INFORMS BRIDGE:


“OPERATE BOTH “NFU MODE NOT
ENGINES FROM RESPONDING, REQUEST
LOCAL” PERMISSION TO OPERATE
FROM LOCAL MODE”

ANNOUNCE: INFORMS ENGINE ROOM:


TAKE ALL PRECAUTIONS AND
“CONTROL
FAILURE, ALL “ STAND BY TO TAKE OVER BE READY TO TAKE OVER
ENGINE ROOM OFF CONTROLS IN ENGINE CONTROL TO ENGINE ROOM
WATCH KEEPERS ROOM AND INTIMATE
AND CONTROL EMP READINESS”
MCR”

BRIEFS AND NOMINATES


PERSONNEL TO OPERATE
FROM ENGINE ROOM
INFORM ENGINE ROOM: INTIMATES MCR:

“CONFIRM ALL PERSONNEL “ALL PERSONNEL CLOSED


CLOSED UP AT LOP AND UP AND BOTH ENGINES
READY TO OPERATE FROM AND CPP READY TO
LOCAL” OPERATE FROM ENGINE
ROOM”
INFORM ENGINE ROOM: INTIMATES MCR:
“TAKE OVER TO CONTROLS “CONTROLS IN LOCAL”
TO LOCAL”
INTIMATE BRIDGE:
“BOTH ENGINES READY TO
OBEY TELEGRAPH FROM
LOCAL AT ENGINE ROOM”

You might also like