BIGGEST POWER CABLE MANUFACTURER IN INDONESIA
NYFGbY 14 - 16
N2XY 17 - 20
NA2XY 21 - 24
NYCY 25 - 26
NYSY 27 - 28
NYBY 29 - 30
NYAF - NYMHY 31 - 32
NYYHY 33
N2XSEBY 51 - 52
N2XSEFGbY 53 - 54
NA2XSEBY 55 - 56
NA2XSEFGbY 57 - 58
Committed To Quality NFA2XSY-T 59
Committed To You
HIGH VOLTAGE POWER CABLES
N2XCK2Y 60
DRUM PACKING 61
OVERHEAD CONDUCTOR & CABLES
NFA2X NFA2X-T
Bundle conductor for overhead distribution Bundle conductor for overhead distribution
network without and with public lighting. network without and with public lighting.
(between pole to pole) (between pole to pole)
AAAC AAAC-S
Stranded All Aluminium Alloy Conductor Stranded All Aluminium Alloy Conductor
XLPE Insulated
ACSR - AS AAC
AAC
SPLN T3.001-1 : 2015 SPLN 41-6 : 1981
Specification
Stranded Aluminium Clad Steel Wire With Grease Stranded All Aluminium Conductor
SPLN 41-6 : 1981
Stranded All Aluminium Conductor
Classification
Bare Conductor
Medium, High Voltage / Bare Conductor Bare Conductor.
AAC
AAC
PHYSICAL PROPERTIES ELECTRICAL PROPERTIES
Cross Sec onal Area Number and Approx. Overall Approx. Net Calculated DC Current Standard
Diameter Wire Diameter Weight Breaking Force Resistance Caring Lenght
Normal Actual at 20oC Capacity
Size Size
mm2 mm2 pcs/mm mm Kg/km kg Ohm/km A m
AAC
16 16.84 7/1.75 5.25 45 310 1.700 110 500
25 27.83 7/2.25 6.75 76 490 1.029 145 500
35 34.36 7/2.50 7.50 94 590 0.833 180 500
50 49.48 7/3.00 9.00 135 810 0.579 225 500
50 45.70 79/1.75 8.75 126 835 0.630 225 500
55 58.07 7/3.25 9.75 160 935 0.493 235 500
70 75.55 19/2.25 11.25 208 1.040 0.381 270 1.000
95 93.27 19/250 12.50 257 1.560 0.308 340 1.000
100 99.30 7\4.25 12.75 272 1.540 0.288 350 1.000
120 112.85 19/2.75 13.75 310 1.890 0.255 930 1.000
150 157.62 19/3.25 16.25 434 2.530 0.183 455 1.000
150 147.12 37/2.25 15.75 406 2.575 0.196 455 1.000
185 111.63 37/2.50 17.50 501 3.110 0.159 520 1.000
200 189.85 19/3.75 18.75 557 3.290 0.137 565 1.000
240 242.54 61/2.25 20.25 670 4.020 0.119 625 1.000
240 238.76 19/4.000 20.00 657 3.700 0.121 625 1.000
300 299.44 61/2.50 22.50 827 4.850 0.097 710 1.000
400 431.18 61/3.00 27.00 1.191 6.675 0.067 855 1.000
500 506.04 61/3.25 29.25 1.398 7.700 0.057 990 1.000
630 643.24 91/3.00 33.00 1.782 9.960 0.045 1.140 1.000
800 754.92 91/3.25 35.75 2.091 11.480 0.038 1.340 1.000
1000 1.005.07 91/3.75 41.25 2.784 14/925 0.029 1.540 1.000
Grounding Wire
For building wire installed in conduit in dry location
and inter wiring in switchboard and control panel.
SNI 04-6629.4 : 2006 / SPLN 42-2 : 1992 SNI IEC 60502-1 : 2009 / SPLN D3.010-2 :2014
NYY ( CU/PVC/PVC )
NYY ( CU/PVC/PVC )
Power cable : Indoors, cable trunking, outdoors and burried Power cable : Indoors, cable trunking, outdoors and
in the ground, for power stations, industry and switchgear burried in the ground , for power stations, industry
as well as for urban supply networks, if mechanical damage and switchgear as well as for urban supply networks,
NYY
is unlikely. NYY if mechanical damage is unlikely.
SNI IEC 60502-1 : 2009 / SPLN D3.010-2 :2014 SNI IEC 60502-1 : 2009 / SPLN D3.010-3 :2014
NYFGbY ( CU/PVC/SFA/PVC )
NYFGbY ( CU/PVC/SFA/PVC )
SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994 SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994
Solid or Stranded Annealed Copper Conductor Solid or Stranded Annealed Copper Conductor
Coloured XLPE Insulated, Black PVC Sheathed Coloured XLPE Insulated, PVC Innersheath / Filler, Black PVC
Sheathed
SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994 SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994
Solid or Stranded Annealed Copper Conductor Solid or Stranded Annealed Copper Conductor
Coloured XLPE Insulated, PVC Innersheath / Filler, Black PVC Coloured XLPE Insulated, PVC Innersheath / Filler, Black PVC
Sheathed Sheathed
Power Cable : Indoors, cable trunking, outdoors and Power Cable : Indoors, cable trunking, outdoors and
burried in the ground, for power station, industry burried in the ground, for power station, industry
and switchgear as well as for urban supply networks, N2XY and switchgear as well as for urban supply networks, N2XY N2XY
if mechanichal damage is unlikely. if mechanichal damage is unlikely.
SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994 SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994
Round Stranded All Alumunium Conductor Round Stranded All Alumunium Conductor
XLPE Insulated, Black PVC Sheathed Colored XLPE Insulated, PVC Innershealth / Filter, Black PVC
Sheathed
SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994 SNI IEC 60502-1 : 2009 / IEC 60502-1 : 2004 / SPLN 43-6 : 1994
Round Stranded All Alumunium Conductor Round Stranded All Alumunium Conductor
( 10 mm² - 35 mm² Round Stranded; 50 mm² - 400 mm² Sector Stranded ) ( 10 mm² - 35 mm² Round Stranded; 50 mm² - 400 mm² Sector Stranded )
Coloured XLPE Insulated, PVC Innersheath / Filler, Black PVC Sheathed. Coloured XLPE Insulated, PVC Innersheath / Filler, Black PVC Sheathed.
Power Cable : Indoors, cable trunking, outdoors and Power Cable : Indoors, cable trunking, outdoors and
burried in the ground, for power station, industry burried in the ground, for power station, industry
and switchgear as well as for urban supply networks, and switchgear as well as for urban supply networks,
NA2XY NA2XY
if mechanichal damage is unlikely. NA2XY NA2XY if mechanichal damage is unlikely.
NYCY ( CU/PVC/CWS/PVC )
PHYSICAL PROPERTIES ELECTRICAL PROPERTIES
Nom Cross Approx. Approx. Conductor L X C Z Max. Max.
Sec on Area Overall Cable Current – Short
IEC 60502 - 1 Diameter Weight Carring Circuit
Capacity at Current
30oc * at 1
Max. DC Max. AC In In Second
Copper Conductor, PVC Insulated, Copper Wire
Resistance Resistance at air ground
Screen, PVC Sheathed at 20 oC 70 oC
mm2 mm kg/km ohm/km ohm/km mH/km Ohm/km uF/km mH/km A A kA
NYCY
1 x 1.5 12.16 177 12.100 14.478 0.416 0.130 0.197 14.478 33 42 0.21
Low Voltage 0.6/1 (1.2) kV
1 x 2.5 12.08 199 7.410 8.866 0.387 0.121 0.235 8.867 42 53 0.36
1 x 4 12.99 248 4.610 5.516 0.386 0.121 0.236 5.517 56 68 0.57
1 x 6 14.06 302 3.080 3.685 0.364 0.114 0.276 3.687 71 85 0.86
For installation in the ground, indoors, cable 1 x 10 15.44 401 1.830 2.190 0.341 0.107 0.340 2.192 96 112 1.43
2 x 1.5 15.42 290 12.100 14.478 0.330 0.104 0.197 14.478 26 31 0.21
trunking and outdoors if subsequent mechanical
2 x 2.5 15.76 338 7.410 8.866 0.307 0.096 0.235 8.867 34 40 0.36
damage is likely, for urban networks, household 2 x 4 17.58 441 4.610 5.516 0.307 0.096 0.236 5.517 45 51 0.57
feeder and street lighting. 2 x 6 19.22 541 3.080 3.685 0.289 0.091 0.276 3.686 57 64 0.86
2 x 10 21.50 722 1.830 2.190 0.270 0.085 0.340 2.191 78 84 1.43
3 x 1.5 15.93 318 12.100 14.478 0.330 0.104 0.197 14.478 22 25 0.21
3 x 2.5 16.33 376 7.410 8.866 0.307 0.096 0.235 8.867 28 33 0.36
• UV Resistance 3 x 3x4 18.29 498 4.610 5.516 0.307 0.096 0.236 5.517 38 42 0.57
• Flame Retardant Cat. A, B, C 3 x 3x6 20.02 618 3.080 3.658 0.289 0.091 0.276 3.686 48 52 0.86
• Flame Retardant Non Category 3 x 10 22.44 839 1.830 2.190 0.270 0.085 0.340 2.191 65 69 1.43
4 x 1.5 16.77 357 12.100 14.478 0.330 0.104 0.197 14.478 22 26 0.21
• Low Smoke Zero Halogen
4 x 2.5 17.28 427 7.410 8.866 0.307 0.096 0.235 8.867 29 33 0.36
4 x 4 19.48 573 4.610 5.516 0.307 0.096 0.236 5.517 39 43 0.57
4 x 6 21.36 716 3.080 3.685 0.289 0.091 0.276 3.686 49 53 0.86
4 x 10 24.01 982 1.830 2.190 0.270 0.085 0.340 2.191 67 70 1.43
• 1.5 - 10 sqmm supplied in solid (re) or non NYCY
5 x 1.5 18.11 386 12.100 14.478 0.330 0.104 0.197 14.478 20 23 0.21
compacted circular stranded (rm) conductor
5 x 2.5 19.24 468 7.410 8.866 0.307 0.096 0.235 8.867 26 29 0.36
shape 16 sqmm supplied in non compacted 7 x 1.5 19.08 452 12.100 14.478 0.330 0.104 0.197 14.478 17 19 0.21
circular stranded (rm) conductor shape 7 x 2.5 20.34 557 7.410 8.866 0.307 0.096 0.235 8.867 22 24 0.36
• 25 - 500 sqmm supplied in non compacted 9 x 1.5 21.08 537 12.100 14.478 0.330 0.104 0.197 14.478 15 16 0.21
9 x 2.5 22.60 668 7.410 8.866 0.307 0.096 0.235 8.867 20 21 0.36
circular stranded (rm) or compacted circular
11 x 1.5 22.49 612 12.100 14.478 0.330 0.104 0.197 14.478 14 15 0.21
stranded (cm) conductor shape 11 x 2.5 24.19 766 7.410 8.866 0.307 0.096 0.235 8.867 18 19 0.36
13 x 1.5 23.69 682 12.100 14.478 0.330 0.104 0.197 14.478 13 14 0.21
13 x 2.5 25.54 860 7.410 8.866 0.307 0.104 0.235 8.867 17 18 0.36
15 x 1.5 24.63 748 12.100 14.478 0.330 0.104 0.197 14.478 12 13 0.21
• 1.5 - 120 sqmm supplied in wooden drum
15 x 2.5 26.60 948 7.410 8.866 0.307 0.096 0.235 8.867 16 16 0.36
@ 1000 meters 20 x 1.5 26.59 904 12.100 14.478 0.330 0.104 0.197 14.478 11 11 0.21
• 150 - 400 sqmm supplied in wooden drum 20 x 2.5 28.82 1.161 7.410 8.866 0.307 0.096 0.235 8.867 14 14 0.36
on available length 27 x 1.5 29.37 1.124 12.100 14.478 0.330 0.104 0.197 14.478 10 10 0.21
NYBY ( CU/PVC/DSTA/PVC )
PHYSICAL PROPERTIES ELECTRICAL PROPERTIES
Nom Cross Approx. Approx. Conductor L X C Z Max. Current – Max.
Sec on Overall Cable Carring Short
IEC 60502 - 1 Area Diameter Weight Capacity at Circuit
30oc * Current
Max. DC Max. AC In air In at 1
Resistance Resistance ground Second
Copper Conductor, PVC Insulated, Double Steel Tape at 20 oC at 70 oC
Armor, PVC Sheathed mm2 mm kg/km ohm/km ohm/km mH/km Ohm/km uF/km mH/km A A kA
NYBY
2 x 6 18.23 600 3.080 3.685 0.293 0.092 0.266 3.686 56 63 0.86
2 x 10 20.03 755 1.830 2.190 0.274 0.086 0.326 2.191 76 83 1.43
Low Voltage 0.6/1 (1.2) kV 2 x 16 22.13 963 1.150 1.376 0.259 0.081 0.397 1.379 100 107 2.29
2 x 25 25.45 1.308 0.727 0.870 0.256 0.080 0.414 0.874 134 138 3.58
2 x 35 27.73 1.612 0.524 0.627 0.247 0.077 0.478 0.632 164 165 5.01
2 x 50 31.21 2.047 0.387 0.464 0.246 0.077 0.485 0.470 202 195 7.15
For installation indoors, cable channels and in 2 x 70 34.91 2.657 0.268 0.321 0.237 0.075 0.569 0.330 253 238 10.01
ground, for industry installations, switchgear, 2 x 95 39.81 3.493 0.193 0232 0.236 0.074 0.586 0.243 314 285 13.59
and power station, if there is a risk that low 2 x 120 43.17 4.184 0.153 0.184 0.231 0.073 0.653 0.198 363 323 17.16
2 x 150 47.25 5.038 0.124 0.150 0.232 0.073 0.648 0.167 418 362 21.45
mechanical damage may occur. 2 x 185 51.89 6.126 0.099 0.121 0.231 0.073 0.653 0.141 485 410 26.46
2 x 240 58.79 7.895 0.075 0.093 0.229 0.072 0.681 0.118 581 475 34.32
2 x 300 64.67 9.634 0.060 0.075 0.228 0.072 0.697 0.104 670 534 42.90
2 x 400 71.83 11.998 0.047 0.060 0.227 0.071 0.725 0.093 776 604 57.20
• UV Resistance
3 x 6 19.03 685 3.080 3.685 0.293 0.092 0.266 3.686 47 52 0.86
• Flame Retardant Cat. A, B, C 3 x 10 20.97 880 1.830 2.190 0.274 0.086 0.326 2.191 63 69 1.43
• Flame Retardant Non Category 3 x 16 23.23 1.147 1.150 1.376 0.259 0.081 0.397 1.379 84 88 2.29
• Low Smoke Zero Halogen 3 x 25 26.81 1.584 0.727 0.870 0.256 0.080 0.414 0.874 112 114 3.58
3 x 35 29.27 1.982 0.524 0.627 0.247 0.077 0.478 0.632 137 136 5.01
3 x 50 33.22 2.552 0.387 0.464 0.246 0.077 0.485 0.470 168 161 7.15
3 x 70 37.19 3.354 0.268 0.321 0.237 0.075 0.569 0.330 212 196 10.01
• 1.5 - 10 sqmm supplied in solid (re) or non 3 x 95 42.44 4.442 0.193 0.232 0.236 0.074 0.586 0.243 262 234 13.59
compacted circular stranded (rm) conductor 3 x 120 46.04 5.354 0.153 0.184 0.231 0.073 0.653 0.198 304 266 17.16
3 x 150 50.42 6.472 0.124 0.150 0.232 0.073 0.648 0.167 350 298 21.45
shape 16 sqmm supplied in non compacted
NYBY 3 x 185 55.61 7.930 0.099 0.121 0.231 0.073 0.653 0.141 406 337 26.46
circular stranded (rm) conductor shape 3 x 240 62.97 10.244 0.075 0.093 0.229 0.072 0.681 0.118 486 391 34.32
• 25 - 630 sqmm supplied in non compacted 3 x 300 69.08 12.509 0.060 0.075 0.225 0.071 0.753 0.103 562 440 42.90
circular stranded (rm) or compacted circular 3 x 400 76.74 15.635 0.047 0.060 0.227 0.071 0.725 0.093 652 498 57.20
4 x 6 20.37 795 3.080 3.685 0.293 0.092 0.266 3.686 48 53 0.86
stranded (cm) conductor shape
4 x 10 22.54 1.037 1.830 2.190 0.274 0.086 0.326 2.191 65 70 1.43
4 x 16 25.07 1.370 1.150 1.376 0.259 0.081 0.397 1.379 87 89 2.29
4 x 25 29.08 1.915 0.727 0.870 0.256 0.080 0.141 0.874 116 115 3.58
• 1.5 - 120 sqmm supplied in wooden drum 4 x 35 31.83 2.417 0.524 0.627 0.247 0.077 0.478 0.632 143 138 5.01
4 x 50 36.43 3.144 0.387 0.464 0.246 0.077 0.485 0.470 175 163 7.15
@ 1000 meters
4 x 70 40.86 4.161 0.268 0.321 0.237 0.075 0.569 0.330 220 198 10.01
• 150 - 400 sqmm supplied in wooden 4 x 95 46.69 5.533 0.193 0.232 0.236 0.074 0.586 0.243 273 238 13.59
drum on available length 4 x 120 50.70 6.690 0.153 0.184 0.231 0.073 0.653 0.198 317 269 17.16
4 x 150 55.79 8.132 0.124 0.150 0.232 0.073 0.648 0.167 364 302 21.45
4 x 185 61.35 9.951 0.099 0.121 0.231 0.073 0.653 0.141 423 342 26.46
4 x 240 69.69 12.906 0.075 0.093 0.229 0.072 0.681 0.118 506 396 34.32
4 x 300 76.70 15.828 0.060 0.075 0.228 0.072 0.697 0.104 584 446 42.90
4 x 400 85.22 19.811 0.047 0.060 0.227 0.071 0.725 0.093 678 505 57.20
IEC 60502-1 and IEC 60331 IEC 60502-1 and IEC 60331
Copper Conductor, Mica Glass Tape, XLPE Insulated, Copper Conductor, Mica Glass Tape, XLPE Insulated,
LSZH (Low Smoke Zero Halogen) / PVC-FR Sheathed Cable LSZH (Low Smoke Zero Halogen) / PVC-FR Sheathed Cable
system, emergency lighting and power, public address and alarm system, emergency lighting and power, public
emergency voice communications systems in highrise building, address and emergency voice communications systems in
control, and instrumentation services in industrial, commercial highrise building, control, and instrumentation services in
and residential complexes. industrial, commercial and residential complexes.
IEC 60502-2 / SNI IEC 60502-2 IEC 60502-2 / SNI IEC 60502-2
Copper / Aluminium Conductor, XLPE Insulated, Copper / Aluminium Conductor, XLPE Insulated,
Copper Tape Screened, PVC Sheathed Cable Copper Tape Screened, PVC Sheathed Cable
Suitable for distribution indoor and outdoor installa- Suitable for distribution indoor and outdoor installa-
tion, Direct Buried (underground) or on Cable tray. tion, Direct Buried (underground) or on Cable tray.
N2XSY NA2XSY
IEC 60502-2 / SNI IEC 60502-2 IEC 60502-2 / SNI IEC 60502-2
Copper / Aluminium Conductor, XLPE Insulated, Copper / Aluminium Conductor, XLPE Insulated,
Copper Tape Screened, PVC Sheathed Cable Copper Tape Screened, PVC Sheathed Cable
Suitable for distribution indoor and outdoor installa- Suitable for distribution indoor and outdoor installa-
tion, Direct Buried (underground) or on Cable tray. tion, Direct Buried (underground) or on Cable tray.
N2XSY NA2XSY
IEC 60502-2 / SNI IEC 60502-2 IEC 60502-2 / SNI IEC 60502-2
Copper / Aluminium Conductor, XLPE Insulated, Copper / Aluminium Conductor, XLPE Insulated,
Copper Tape Screened, PVC Sheathed Cable Copper Tape Screened, PVC Sheathed Cable
Suitable for distribution indoor and outdoor installa- Suitable for distribution indoor and outdoor installa-
tion, Direct Buried (underground) or on Cable tray. tion, Direct Buried (underground) or on Cable tray.
N2XSY NA2XSY
IEC 60502-2 / SNI IEC 60502-2 IEC 60502-2 / SNI IEC 60502-2
Copper / Aluminium Conductor, XLPE Insulated, Copper / Aluminium Conductor, XLPE Insulated,
Copper Tape Screened, PVC Sheathed Cable Copper Tape Screened, PVC Sheathed Cable
Suitable for distribution indoor and outdoor installa- Suitable for distribution indoor and outdoor installa-
tion, Direct Buried (underground) or on Cable tray. tion, Direct Buried (underground) or on Cable tray.
N2XSY NA2XSY
IEC 60502-2 / SNI IEC 60502-2 IEC 60502-2 / SNI IEC 60502-2
Copper / Aluminium Conductor, XLPE Insulated, Copper / Aluminium Conductor, XLPE Insulated,
Copper Tape Screened, PVC Sheathed Cable Copper Tape Screened, PVC Sheathed Cable
Suitable for distribution indoor and outdoor installa- Suitable for distribution indoor and outdoor installa-
tion, Direct Buried (underground) or on Cable tray. tion, Direct Buried (underground) or on Cable tray.
N2XSY NA2XSY
N2XSEBY ( CU/XLPE/CTS/DSTA/PVC )
PHYSICAL PROPERTIES ELECTRICAL PROPERTIES
Nom Cross Approx. Approx. Conductor L X C Z Max. Current Max.
Sec on Overall Cable – Carring Short
IEC 60502-2 Area Diameter Weight Capacity at Circuit
30oc * Current
Max. DC Max. AC In In at 1
Resistance Resistance at air ground Second
at 20 oC 70 oC
Copper Conductor, XLPE Insulated, Copper Wire / mm2 mm kg/km ohm/km ohm/km mH/km Ohm/km uF/km mH/km A A kA
Tape Screened, PVC Inner Sheathed, Double Steel N2XSEBY
3.6/6 (7.2) kV
Tape Armor, PVC Sheathed 3 x 35 42.48 3.218 0.524 0.668 0.338 0.106 0.214 0.677 191 176 501
3 x 50 45.03 3.777 0.387 0.494 0.326 0.102 0.234 0.504 225 205 7.15
3 x 70 49.42 4.724 0.268 0.342 0.306 0.096 0.275 0.355 278 250 10.01
3 x 95 53.19 5.765 0.193 0.247 0.293 0.092 0.312 0.263 335 297 13.59
Medium Voltage 3 x 120 56.81 6.790 0.153 0.196 0.284 0.089 0.343 0.215 382 335 17.16
3 x 150 59.93 7.849 0124 0.160 0.276 0.087 0.372 0.181 431 375 21.45
3.6/6 (7.2) kV 3 x 185 63.41 9.164 0.099 0.128 0.269 0.085 0.406 0.153 490 421 26.46
6/10 (12) kV 3 x 240 69.49 11.109 0.075 0.099 0.262 0.082 0.447 0.128 575 487 34.32
3 x 300 75.69 13.759 0.060 0.080 0.258 0.081 0.467 0.113 653 547 42.90
8.7/15 (17.2) kV 3 x 400 85.23 17.776 0.047 0.064 0.257 0.081 0.470 0.102 757 622 57.20
12/20 (24) kV 6/10 (12) kV
3 x 35 47.17 3.705 0.54 0.668 0.361 0.113 0.179 0.678 196 177 5.01
18/30 (36) kV
3 x 50 49.32 4.233 0.387 0.494 0.348 0.109 0.195 0.506 231 208 7.15
3 x 70 53.51 5.189 0.268 0.342 0.326 0.102 0.228 0.357 286 252 10.01
3 x 95 57.68 6.321 0.193 0.247 0.311 0.098 0.256 0.265 343 299 13.59
3 x 120 60.90 7.311 0.153 0.196 0.301 0.094 0.281 0.217 391 339 17.16
For installation indoor, in ground direct burried, 3 x 150 64.02 8.392 0.124 0.160 0.292 0.092 0.304 0.184 441 378 21.45
for power station and switchgear, if there is a 3 x 185 67.50 9.733 0.099 0.128 0.284 0.089 0.330 0.156 500 425 26.46
3 x 240 73.55 11.737 0.075 0.099 0.274 0.086 0.372 0.130 583 490 34.32
risk that low mechanical damage may occur. 3 x 300 48.48 14.208 0.060 0.080 0.266 0.084 0.408 0.155 661 550 42.90
N2XSEBY 3 x 400 86.96 18.094 0.047 0.064 0.262 0.082 0.432 0.104 762 625 57.20
8.7/15 (17.5) kv
3 x 35 52.32 4.276 0.524 0.668 0.386 0.121 0.153 0.679 203 180 5.01
• UV Resistance 3 x 50 54.47 4.823 0.387 0.494 0.371 0.117 0.165 0.507 239 210 7.15
3 x 70 59.06 5.884 0.268 0.342 0.347 0.109 0.191 0.359 293 255 10.01
• Flame Retardant Cat. A, B, C 3 x 95 68.83 6.992 0.193 0.247 0.331 0.104 0.214 0.268 352 303 13.59
• Flame Retardant Non Category 3 x 120 66.05 8.011 0.153 0.196 0.319 0.100 0.234 0.220 401 342 17.16
3 x 150 69.17 9.122 0.124 0.160 0.310 0.097 0.252 0.186 451 382 21.45
3 x 185 73.05 10.575 0.099 0.128 0.301 0.094 0.273 0.159 510 429 26.46
3 x 240 78.70 12.557 0.075 0.099 0.289 0.091 0.306 0.133 594 494 34.32
3 x 300 84.85 15.906 0.060 0.080 0.281 0.088 0.334 0.118 676 556 42.90
• 35 - 300 sqmm supplied in compacted 3 x 400 92.11 19.080 0.047 0.064 0.274 0.086 0.357 0.107 775 630 57.20
circular stranded (cm) conductor shape 12/20 (24) kV
3 x 35 57.24 4.878 0.524 0.668 0.406 0.128 0.136 0.680 208 182 5.01
3 x 50 59.39 5.445 0.387 0.494 0.391 0.123 0.147 0.509 244 212 7.15
3 x 70 63.58 6.479 0.268 0.342 0.365 0.115 0.169 0.361 300 258 10.01
3 x 95 67.35 7.617 0.193 0.247 0.347 0.109 0.189 0.270 360 306 13.59
• 35 - 70 sqmm supplied in wooden drum
3 x 120 70.57 8.663 0.153 0.196 0.335 0.105 0.205 0.222 409 346 17.16
@ 1000 meters 3 x 150 74.29 9.915 0.124 0.160 0.325 0.102 0.221 0.189 458 385 21.45
• 95 - 300 sqmm supplied in wooden 3 x 185 77.77 11.322 0.099 0.128 0.315 0.099 0.238 0.161 519 432 26.46
3 x 240 84.63 14.180 0.075 0.099 0.302 0.095 0.266 0.136 607 499 34.32
drum on available length 3 x 300 89.37 16.748 0.060 0.080 0.293 0.092 0.290 0.121 687 561 42.90
3 x 400 97.23 20.135 0.047 0.064 0.286 0.090 0.311 0.109 784 634 57.20
18/30 (36) kV
3 x 35 68.84 6.445 0.524 0.668 0.450 0.141 0.111 0.683 220 186 5.01
3 x 50 70.99 7.058 0.387 0.494 0.432 0.136 0.119 0.512 258 218 7.15
3 x 70 75.58 8.262 0.268 0.342 0.404 0.127 0.136 0.365 314 265 10.01
3 x 95 79.35 9.483 0.193 0.247 0.383 0.120 0.150 0.274 376 312 13.59
3 x 120 83.98 11.459 0.153 0.196 0.369 0.116 0.162 0.227 428 352 17.16
3 x 150 87.10 12.696 0.124 0.160 0.358 0.112 0.173 0.195 480 393 21.45
3 x 185 90.58 14.211 0.099 0.128 0.346 0.109 0.186 0.167 542 441 26.46
3 x 240 96.23 16.418 0.075 0.099 0.331 0.104 0.206 0.143 629 509 34.32
3 x 300 101.37 19.197 0.060 0.080 0.320 0.101 0.224 0.128 709 570 42.90
3 x 400 108.63 22.590 0.047 0.064 0.311 0.098 0.241 0.116 811 646 57.20
N2XSEFGbY ( CU/XLPE/CWS/SFA/PVC )
PHYSICAL PROPERTIES ELECTRICAL PROPERTIES
Nom Cross Approx. Approx. Conductor L X C Z Max. Current Max.
Sec on Overall Cable – Carring Short
Area Diameter Weight Capacity at Circuit
IEC 60502-2
30oc * Current
Max. DC Max. AC In In at 1
Resistance Resistance at air ground Second
at 20 oC 70 oC
Copper Conductor, XLPE Insulated, Copper Wire / mm2 mm kg/km ohm/km ohm/km mH/km Ohm/km uF/km mH/km A A kA
Tape Screened, PVC Inner Sheathed, Galvanized Steel N2XSEFGbY
3.6/6 (7.2) kV
Flat Armor, PVC Sheathed 3 x 35 42.65 2.922 0.524 0.668 0.334 0.105 0.219 0.677 190 175 50.1
3 x 50 45.19 3.465 0.387 0.494 0.322 0.101 0.240 0.504 224 205 7.15
3 x 70 49.39 4.368 0.268 0.342 0.303 0.095 0.282 0.355 277 249 10.01
3 x 95 53.15 5.390 0.193 0.247 0.290 0.091 0.320 0.263 335 295 13.59
Medium Voltage 3 x 120 56.77 6.397 0.153 0.196 0.281 0.088 0.352 0.215 381 334 17.16
3 x 150 59.89 7.446 0.124 0.160 0.274 0.086 0.382 0.181 430 373 21.45
3.6/6 (7.2) kV 3 x 185 63.37 8.751 0.099 0.128 0.267 0.084 0.417 0.153 488 420 26.46
6/10 (12) kV 3 x 240 69.45 10.673 0.075 0.099 0.260 0.081 0.459 0.128 572 484 34.32
3 x 300 75.65 13.312 0.060 0.080 0.256 0.080 0.473 0.113 650 543 42.90
8.7/15 (17.2) kV
3 x 400 83.99 16.472 0.047 0.064 0.255 0.080 0.480 0.102 748 615 57.20
12/20 (24) kV 6/10 (12) kV
3 x 35 47.13 3.350 0.524 0.668 0.358 0.122 0.182 0.678 196 177 5.01
18/30 (36) kV
3 x 50 49.28 3.865 0.387 0.494 0.344 0.108 0.199 0.505 231 207 7.15
3 x 70 53.47 4.795 0.268 0.342 0.323 0.101 0.232 0.357 285 252 10.01
3 x 95 57.64 5.908 0.193 0.247 0.308 0.094 0.261 0.265 342 299 13.59
3 x 120 60.86 6.884 0.153 0.196 0.298 0.094 0.286 0.217 390 338 17.16
For installation in the ground, indoors, cable 3 x 150 64.18 7.986 0.124 0.160 0.290 0.091 0.310 0.183 439 377 21.45
trunking and outdoors if increased mechanical 3 x 185 67.66 9.319 0.099 0.128 0.282 0.088 0.337 0.155 498 423 26.46
3 x 240 73.51 11.264 0.075 0.099 0.272 0.085 0.379 0.130 580 487 34.32
protection is required or where high-pulling 3 x 300 78.45 13.736 0.060 0.080 0.264 0.083 0.416 0.115 657 546 42.90
stresses may occur during installation or 3 x 400 85.71 16.755 0.047 0.064 0.260 0.082 0.441 0.103 753 618 57.20
8.7/15 (17.5) kV
operation. 3 x 35 52.29 3.877 0.524 0.668 0.383 0.120 0.154 0.679 202 180 5.01
N2XSEFGbY 3 x 50 54.43 4.413 0.387 0.494 0.368 0.116 0.168 0.507 238 210 7.15
3 x 70 59.03 5.446 0.268 0.342 0.344 0.108 0.194 0.359 292 254 10.01
3 x 95 62.79 6.534 0.193 0.247 0.328 0.103 0.217 0.267 351 302 13.59
• UV Resistance 3 x 120 66.01 7.540 0.153 0.196 0.317 0.099 0.237 0.220 400 341 17.16
• Flame Retardant Cat. A, B, C 3 x 150 69.13 8.641 0.124 0.160 0.308 0.097 0.256 0.186 450 381 21.45
3 x 185 73.01 10.080 0.099 0.128 0.299 0.094 0.277 0.158 508 427 26.46
• Flame Retardant Non Category 3 x 240 78.66 12.044 0.075 0.099 0.287 0.090 0.311 0.133 591 492 34.32
3 x 300 83.6 14.559 0.060 0.080 0.279 0.088 0.340 0.118 669 551 42.90
3 x 400 90.87 17.647 0.047 0.064 0.273 0.086 0.363 0.106 766 623 57.20
12/20 (24) kV
• 35 - 400 sqmm supplied in compacted 3 x 35 57.21 4.436 0.524 0.668 0.404 0.127 0.138 0.680 207 182 5.01
3 x 50 59.35 4.991 0.387 0.494 0.388 0.122 0.149 0.508 244 212 7.15
circular stranded (cm) conductor shape 3 x 70 63.55 5.998 0.268 0.342 0.362 0.114 0.171 0.361 299 257 10.01
3 x 95 67.51 7.153 0.193 0.247 0.345 0.108 0.191 0.269 358 305 13.59
3 x 120 70.73 8.187 0.153 0.196 0.333 0.104 0.207 0.222 408 344 17.16
3 x 150 74.25 9.391 0.124 0.160 0.323 0.101 0.223 0.189 457 383 21.45
• 35 - 50 sqmm supplied in wooden drum 3 x 185 77.73 10.788 0.099 0.128 0.313 0.098 0.241 0.161 517 430 26.46
3 x 240 83.38 12.797 0.075 0.099 0.300 0.094 0.270 0.136 601 495 34.32
@ 1000 meters 3 x 300 88.12 15.317 0.060 0.080 0.291 0.091 0.294 0.121 680 556 42.90
• 70 - 400 sqmm supplied in wooden 3 x 400 95.79 18.561 0.047 0.064 0.284 0.089 0.315 0.109 776 627 57.20
18/30 (36) kV
drum on available length 3 x 35 68.81 5.904 0.524 0.668 0.447 0.140 0.112 0.683 219 186 501
3 x 50 70.95 6.505 0.387 0.494 0.430 0.135 0.120 0.512 257 217 7.15
3 x 70 75.55 7.681 0.268 0.342 0.401 0.126 0.137 0.365 314 263 10.01
3 x 95 79.31 8.883 0.193 0.247 0.381 0.120 0.151 0.274 375 311 13.59
3 x 120 82.53 9.986 0.153 0.196 0.367 0.115 0.163 0.227 425 351 17.16
3 x 150 85.85 11.222 0.124 0.160 0.356 0.112 0.175 0.194 476 391 21.45
3 x 185 89.33 12.692 0.099 0.128 0.345 0.108 0.187 0.167 537 438 26.46
3 x 240 94.78 14.776 0.075 0.099 0.329 0.103 0.208 0.142 624 505 34.32
3 x 300 100.12 17.542 0.060 0.080 0.319 0.100 0.225 0.127 702 564 42.90
3 x 400 107.39 20.848 0.047 0.064 0.309 0.097 0.243 0.115 801 638 57.20
N2XCK2Y
N2XCK2Y
Cm : Compacted Stranded
rs : Miliken Segmental