NOTES

C
CANOPY STRUCTURE
CW-07 G-01 CW-07
PT-08O
4,100
100 1,900 100 1,900 100
BOH

125

34 34 34 34

100 100
UG #32 UG #31

66 66
WOF WOF

66

100
CH + 9.00

SILVER
UG #20-28
METALLIC
UG #33 UG #30
WOF

100
WOF WOF

C C

UG #34

1,820 UG #29

WOF

WOF

CH + 9.00

HANGING
LIGHT BULB 30
170 30 CH + 9.00

CANOPY STRUCTURE 150


All drawings to be reviewed by
MEP & Structural Consultant
CH + 9.00 CW

PT-08O
CH + 9.00

PROJECT

KEYPLAN
150

34 166 166 166 34 158


LENMARC MALL SURABAYA

200 200 200 175


100 100 100 CANOPY EDGE PROFILE Jl. Mayjen Yono Suwoyo No.9,
STEEL PLATE 2mm Pradahkalikendal, Kec. Dukuhpakis,
100 100
POWDER COATED DARK GREY Kota SBY, Jawa Timur 60226

34 34
PT-08O 50
CW-07 66 66
33 66 66 66 34
G-01
34 34 34 34 34 TRIMDECK ROOF GALVALUME OWNER
G-01
MD-01 GUTTER
BUKIT DARMO PROPERTY
Jalan Tanah Abang III No.6,
2,225

RT.1/RW.8, Petojo Sel., Kecamatan


Gambir, Kota Jakarta Pusat, Daerah
+10.30 Khusus Ibukota Jakarta 10160
COMPOSITE WOOD SLAT
w/ STEEL HOLLOW INSIDE

460
CW-07 CONSTRUCTION MANAGEMENT

+10.30 STEEL HOLLOW 100X100 mm


DRAIN PIPE
Refer to MEP Consultant PT-08O

CANOPY STEEL STRUCTURE


100

STEEL HOLLOW 100X100 mm PT-08O


PT-08O (refer to Engineer)

HOLLOW FRAME ARCHITECTURE CONSULTANT


COMPOSITE WOOD SLAT
w/ STEEL HOLLOW INSIDE 40x40 mm
C

CW-07 (refer to Engineer)

TYPICAL UG OUTDOOR ALFRESCO CEILING PLAN DETAIL D-01 DETAIL D-02 MCKINGLEY + TEAM ARCHITECTS
SCALE 1:20 SCALE 1:5 SCALE 1:5 PT. MITRA TENAGA ANDALAN

INTERIOR CONSULTANT

MCKINGLEY + TEAM ARCHITECTS


PT. MITRA TENAGA ANDALAN

COMPOSITE WOOD SLAT STRUCTURE CONSULTANT


w/ STEEL ROD INSIDE
CW-07
D-01 D-02
Detail Detail

+10.50
1st Floor +10.40
MECHANICAL & ELECTRICAL CONSULTANT
+10.30
CANOPY STEEL STRUCTURE
PT-08O
+10.00
COMPOSITE WOOD SLAT
STEEL PLATE EDGE
w/ STEEL HOLLOW INSIDE
PT-08O
CW-07 QUANTITY SURVEYOR
1,000

STEEL HOLLOW 100X100 mm


PT-08O

G-01

DRAWING TITLE
HANGING LIGHT BULB

ALFRESCO UG CANOPY DETAIL

UG OUTDOOR ALFRESCO - SECTION C UG OUTDOOR ALFRESCO - 3D VIEW DRAWING SCALE


1:20, 1:5

SCALE 1:20 NTS DRAWN CHECKED APPROVED

DRAWING
DATE DWG. NO. REVISION

FOR CONSTRUCTION 8/5/2022 FC.G.54


GSPublisherVersion 0.0.100.17

You might also like