Professional Documents
Culture Documents
AIR
CLEANERS
Proper engine combustion requires a consistent source of clean, non-toxic air, commonly
provided through an inlet louver/ventilation system. Airflow is directed into the engine’s air
inlet through Clarke’s standard air cleaner designed to filter out air impurities to ensure
your Clarke fire pump driver will receive a clean source of air.
In areas with greater air impurities, the optional single and two stage air cleaners may
be a better alternative.
Single stage air cleaners filter impurities through a primary filter element (rated
at 85%) without the use of a pre-cleaner. Two Stage air cleaners, use the same
primary filter element as the single stage air cleaner, but incorporates the use of
a pre-cleaner used to remove 98% of containments in the air before being sent
to the primary filter.
100 Progress Place, Cincinnati, OH 45246 Grange Works, Lomand Rd, Coatbridge, ML5-2NN
United States of America United Kingdom
Tel +1-513-475-3473 Fax +1-513-771-8930 Tel +44-1236-429946 Fax +44-1236-427274
www.clarkefire.com
R
The standard air cleaner does not include an option for an air differential indicator, gauge or an
alarm signal.
The air cleaner filter is disposable and should be replaced on an annual basis. In order for
proper usage, the air cleaner filter must be completely enclosed in the steel housing mounted
on the engine. An air differential indicator is included standard with the single stage air cleaner.
An optional remote mounted air differential gauge and alarm signal is available.
The air cleaner filter is disposable and should be replaced annually. In order for proper usage,
the air cleaner filter must be completely enclosed in the plastic housing mounted on the engine.
An air differential indicator is included standard with the dual stage air cleaner. A remote
mounted air differential gauge and alarm is available.
STANDARD OPTIONAL
FEATURES
AIR CLEANER SINGLE STAGE TWO STAGE
Type • Indoor service only, with shield • Enclosed • Enclosed
Recommended • Indoor applications with minimal air • Light dust environments • Medium to heavy dust
Application impurities • Applications located in tropical and environments
other environments with light air • Applications located in desert,
impurities tropical and other environments
with heavy air impurities
Cleaning Method • Disposable • Disposable • Disposable
Filter Housing Material • Steel drip shield • Steel housing • Plastic Housing
Air Differential Gauge and • Optional Gauge/Alarm Panel • Standard Indicator • Standard Indicator
Alarm • Optional Gauge/Alarm Panel • Optional Gauge/Alarm Panel
Guarding • Drip Shields • Raincap • Raincap
100 Progress Place, Cincinnati, OH 45246 Grange Works, Lomand Rd, Coatbridge, ML5-2NN
United States of America United Kingdom
Tel +1-513-475-3473 Fax +1-513-771-8930 Tel +44-1236-429946 Fax +44-1236-427274