Meter Identification
Instrument Type Q.Sonic plus
Serial Number
Meter Name SIMULATOR
Meter IP Address SimDevice=C:\ProgramData\Elster\Sonic
Explorer\Devices\Global\Configuration\Si
mulator\NGQ
SonicExplorer Version: 1.0.8.1006
DSP
Burst Start Frequency 223 Hz
Burst Stop Frequency 86 Hz
Burst Number SB Pulses 1
Burst Number Frequencies 12
Burst Number Transition Frequencies 0
Burst Number CMB Pulses 60
Burst Number Repetitions 1
Measurement Sample Rate 15
Measurement Cycle 3500
SNR Limit 10 dB
Transit Time Filter Mode MEDIAN FILTERING
Detection Settings
Path Zero Cross Inverted Detec. Threshold (%) Detec. Method Detec. Criteria (%)
B1CW Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
B1CCW Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
A1 Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
A2 Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
B2CW Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
B2CCW Detect Second ZC Positive Signal 150 Q-Sonic 4 Method 200
Spoolpiece Parameters
Diameter 0.370007 m
Path Length [m] Angle [°] Receive Delay
B1CW 0.558061 62.2 10000
B1CCW 0.175409 50 10000
A1 0.175409 50 10000
A2 0.24803 50 10000
B2CW 0.24803 50 10000
B2CCW 0.175409 50 10000
Velocity of Gas
VoGraw Low Limit -40 m/s
VoGraw High Limit 40 m/s
Minimum Performance 20 %
TransitTime Std. Deviation High Limit 3500
Profile Correction
Coefficient Axial Swirl Custom
P1 3792 3401 3401
P2 26 66 66
P3 0.7502 1.0037 1.0037
P4 0.98299 1.00192 1.0137
P5 0.0324 0.0204 0.0204
P6 -3.3193 -3.2056 -3.2056
Density/Viscosity
Density & Viscosity Mode Static
Static density 45 kg/m³
Static viscosity 0 Pa s
Pressure & Temperature Mode Static
Static temperature 20 °C
Static pressure 1.01315 bar-a
Linearization OFF
Combination Parameters
Combination Method FIXED
Geometry Correction
Geometry Correction ON
Geometry Correction Mode Operating Conditions