Professional Documents
Culture Documents
Assets
Steam Turbine Generator
Double girder EOT - 2 trolleys wire rope hoists
Documentation
Repaired
Date Reported Dec 16, 2022
Technician Niko Andrian
Task Type Certified test load
Fault Code Acceptable
Risk No direct risk
Recommendation Adjustment Procedure
Comment:
. Load test 110 % 82 T
.
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
1/8
SERVICE REPORT
Dec 19, 2022 9:09 AM Chaerudin Chaerudin, Customer Dec 16, 2022 10:23 PM Niko Andrian, Technician
Workshop
Single girder EOT - 1 trolley wire rope hoist
Manufacturer KONECRANES
Serial number ML01SMC01
Site Location Solok - Sumatera Barat
Capacity/SWL 10
Model EKKE CXT50410100P55FDL0S
Service Products MAINMAN Planned Maintenance
Hoists
Asset Description Serial number Model Type Manufacturer Capacity
CXT50410100P55
Workshop 12242959 KONECRANES 10 t
FDLOS
Documentation
Repaired
Date Reported Dec 18, 2022
Technician Niko Andrian
Task Type Certified test load
Fault Code Acceptable
Risk No direct risk
Recommendation No Action
Comment:
. Test load OHC workshop
.
Dec 19, 2022 9:09 AM Chaerudin Chaerudin, Customer Dec 18, 2022 8:39 PM Niko Andrian, Technician
Manufacturer KONECRANES
Serial number ML01SMD312
Site Location Solok - Sumatera Barat
Capacity/SWL 20.000 kg
Model EL1-CXT60410200P64EEN0S
Service Products MAINMAN Planned Maintenance
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
2/8
SERVICE REPORT
Hoists
Asset Description Serial number Model Type Manufacturer Capacity
EL1-
Hot Well Pump 12240944 CXT60410200P64 KONECRANES 20 t
EEN0S
Documentation
Repaired
Date Reported Dec 17, 2022
Technician Niko Andrian
Task Type Certified test load
Fault Code Acceptable
Risk No direct risk
Recommendation Replace
Comment:
. Test load OHC Hot well pump
. test 110% swl 20 t
.
Dec 19, 2022 9:09 AM Chaerudin Chaerudin, Customer Dec 17, 2022 9:48 AM Niko Andrian, Technician
Cooling Tower
Pillar jib crane - electric chain hoist
Manufacturer KONECRANES Volt/Ph/Hz 400-3-50
Serial number ML01SMD21
Criticality Low
Site Location Solok - Sumatera Barat
Capacity/SWL 2500 kg
Jib Crane
Model
CLX2581250M52SP200N148405
Service Products MAINMAN Planned Maintenance
Hoists
Asset Description Serial number Model Type Manufacturer Capacity
CLX2581250M52
Cooling Tower Jib Crane 1801400007 KONECRANES 2.5 t
SP200N148405
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
3/8
SERVICE REPORT
Documentation
Repaired
Date Reported Dec 18, 2022
Technician Niko Andrian
Task Type Certified test load
Fault Code Acceptable
Risk No direct risk
Recommendation Monitor/Follow insp. interval
Comment:
. Test load OHC Jib crane
.
Dec 19, 2022 9:09 AM Chaerudin Chaerudin, Customer Dec 18, 2022 8:44 PM Niko Andrian, Technician
Chemical Building
Monorail system - 1 trolley electric chain hoist
Documentation
Repaired
Date Reported Dec 18, 2022
Technician Niko Andrian
Task Type Certified test load
Fault Code Acceptable
Risk No direct risk
Recommendation Monitor/Follow insp. interval
Comment:
. Test load OHC chemichal
.
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
4/8
SERVICE REPORT
Dec 19, 2022 9:09 AM Chaerudin Chaerudin, Customer Dec 18, 2022 8:50 PM Niko Andrian, Technician
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
5/8
SERVICE REPORT
Report Created: Dec 19, 2022 2:42 PM
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
6/8
SERVICE REPORT
muara labuh
Dec 18, 2022 Niko Andrian / Test load Chemical 1.5
OHC chemichal Building
PT.Supreme energy
muara labuh
Dec 18, 2022 Niko Andrian / Test load Chemical 1
OHC chemichal Building
PT.Supreme energy
muara labuh
Dec 18, 2022 Niko Andrian / Test load Workshop 4
workshop PT.Supreme
energy muara labuh
Dec 18, 2022 Niko Andrian / meal Workshop 1
adjustment
Dec 19, 2022 Niko Andrian / Reporting Steam Turbine 8
PT.Supreme energy Generator
muara labuh
Dec 19, 2022 Niko Andrian / meal Steam Turbine 1
adjustment Generator
0 54
Travelling Time, Expenses and any Overtime Premium incurred will be charged extra to the above hours.
Please note that this is not the final report version and some information may change. Your final report will be available later in yourKONECRANES.com
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
7/8
SERVICE REPORT
Component Condition
Acceptable (No issues detected)
! Need Attention
Production Risk
Indicates an inefficient condition. Failure to remedy such condition before continued operation of the identified asset may result in inefficient asset
performance or an interruption in production.
Undetermined Condition
Indicates that the condition could not be directly verified through visual inspection as a result of asset configuration and/or obstruction.
The condition of certain components cannot be directly verified through visual inspection without further disassembly and/or the use of other
inspection methods. These advanced services are generally excluded from the scope of typical compliance and preventive maintenance inspections.
Consultation Services may be added to a Service Program or offered on a stand-alone basis to assess the condition of these components. Inspection
frequency for these components should follow OEM recommendations and/or governing regulations. If no records are available, we recomm end
appropriate inspections be carried out to determine current condition and to establish a baseline for recurring inspections.
Improvement Opportunity
Indicates a potential opportunity to improve the safety, productivity, application or useful life of the asset.
A member of the Konecranes Group. © 2022 Konecranes. All rights reserved. All services are subject to and carried
out under Konecranes General Terms and Conditions for Services (v. 23.5.2021), which are attached hereto or made
available upon request.
8/8