You are on page 1of 1

TECHNICAL REPORT Mod. E2296.

00001
Ver. 10.003
GERDP: TOWER CRANE EQUIPMENT Pag. 1 di 1

DATE Time Type operation ID &Name


5/9/2019 2:00pm Electronic

Select section making A cross

RIGHT LEFT SADDLE CENTRAL DAM

Select equipment making a cross

TEREX 721 TEREX 321 POTAIN M610 POTAIN M365 ALPHA Overhead crane

Equipment : Object with problem (identification code ):


Terex 721 number :14
Description of action: no start and slewing ,hook ,trolley no work
Called from ,for : Hector Cuello
Situation found :
 The crane nothing work
 The crane no start
 Due to AC/DC power supply failure
 And also the master PLC module was broken
Actions :
 Then we changed new AC/DC converter
 And also we changed master PLC module
Suggestion to avoid the problem in the future :

Type of intervention: Mechanical Electrica Electronic


l
Signature of caller :