You are on page 1of 3

Technician Intervention Report

Superstucture type: VIN:


DLK 52 CC 427751
Chassis type: S/No
Mercedes 12072
Mileage (km): Operating hours (PTO) License Plate No.: Job Order No.:
32300 1634 34 VY 7528
Intervention location: Report date: 05.12.20
Customer Adress:
Istanbul Itfaiye
Istanbul
Turkey
Detected failures, damages, defects, etc..
Ladder checkup and inspection carried out.

Test run of turntable ladder.


Ladder was already checked by Bioeksim.
Found additional problems.

Cener Mag has changed the levelling ring brake without original parts from
Magirus!
The work was carried out from untrained and not certified people.

The ladder is out of service and is not usable for the fire brigade!

The 10 years services are due.

The service need to carryout, include all oil, all hydraulic hoses, filter and the spring look cable.

One rung in the ladder set I. Need to replace.

-1-
Technician Intervention Report

Superstructure computer fan is defective. Need to replace.

Main control push buttons are worn out. 7x need to replace.

Ladder carrier, Heavy rust.

-2-
Technician Intervention Report

All outriggers are rusty. Fist one is heavy rusty, need to replace.

Some part at the lift/ springs and small ropes. Need to replace.

Larch Tobias

Larch Tobias
MVKF

-3-