1181 CFM
SG 250X300
Δp>=5 pa
1181 CFM
SG 250X300
Δp>=5 pa
1121 CFM
SG 400X350
Δp>=12.5 pa
104 CFM
SG 100X200
Δp>=12.5 pa
Application/PS No. Reviewing Engineer's Signature/Date
VCD VCD VCD VCD
Date :
SG 250X300 SG 250X300 SG 400X350 SG 100X200
Δp>=5 pa
VCD
Δp>=5 pa
VCD
Δp>=12.5 pa
VCD
Δp>=12.5 pa
VCD
N/2022/0003504
1181 CFM 1181 CFM 1121 CFM 104 CFM
SG 250X300 SG 250X300 SG 400X350 SG 100X200
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
I, ENGR. ROMEO BENID PLASENCIA AN MECHANICAL ENGINEER WITH UPDA/QCD REGISTRATION NO. 1239,
1181 CFM
VCD
1181 CFM
VCD
1121 CFM
VCD
104 CFM
VCD
BEING THE CONSULTANT, HEREBY CERTIFY THAT THE FIRE SAFETY WORKS SHOWN ON THIS AIR CONDITIONING
AND MECHANICAL VENTILATION (ACMV) ARE IN ACCORDANCE WITH THE QCD TECHNICAL REQUIREMENTS
SG 250X300 SG 250X300 SG 400X350 SG 100X200
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
FURTHER, I HEREBY CERTIFY THAT I AM FULLY AWARE ON THE APPROVAL OF FIRE SAFETY ENGINEERING
VCD VCD VCD VCD
1181 CFM
SG 250X300
1181 CFM
SG 250X300
1121 CFM
SG 400X350
104 CFM
SG 100X200
PLANS AND DO NOT RELIEVE MYSELF OF BEING THE CONSULTANT ON THE RESPONSIBILITY IN CONTINUED
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
COMPLIANCE TO THE QCD TECHNICAL REQUIREMENTS GUIDE 2022, APPLICABLE/ACCEPTABLE NFPA CODES,
1181 CFM
VCD
1181 CFM
VCD
1121 CFM
VCD
104 CFM
VCD
VCD VCD VCD VCD AFFIXED IS MY NAME AND COMPANY STAMP TO ATTEST WITH THE ABOVE UNDERTAKING.
1181 CFM 1181 CFM 1121 CFM 104 CFM
SG 250X300 SG 250X300 SG 400X350 SG 100X200
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
1181 CFM
SG 250X300
1181 CFM
SG 250X300
1121 CFM
SG 400X350
104 CFM
SG 100X200
(SIGNATURE OF CONSULTANT)
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
09/03/2025 23/07/2023
Δp>=5 pa Δp>=5 pa Δp>=12.5 pa Δp>=12.5 pa
DEVELOPMENTCONSULTINGENGINEERINGCO.
SG 250X300 SG 250X300 SG 400X350 Δp>=12.5 pa SG 100X200 Δp>=12.5 pa
Δp>=5 pa Δp>=5 pa
QATARIPRIVATESHAREHOLDINGCOMPANY
DESIGN-SUPERVISION-PROJECTMANAGEMENT
SCHEDULE OF SPLIT TYPE AC AT FIRST BASEMENT SCHEDULE OF AC'S AT 2nd,4th,7th & 8th FLOORS
COOLING CAPACITY POWER SUPPLY POWER CONSUMED COOLING CAPACITY POWER SUPPLY POWER CONSUMED
Reference Qty REMARKS Reference QTY REMARKS
NOMINAL (TR) V/PH/HZ (KW) NOMINAL (TR) V/PH/HZ (KW)
SPU-01 1.0 240/1/50 1.2 2.0 WALL MOUNTED SPLIT TYPE DSPU-01 1.0 240/1/50 1.2 3.0 DUCTED SPLIT TYPE
SPU-02 1.5 240/1/50 1.8 --- WALL MOUNTED SPLIT TYPE DSPU-02 1.5 240/1/50 1.8 11.0 DUCTED SPLIT TYPE
SPU-03 2.0 240/1/50 2.4 6.0 WALL MOUNTED SPLIT TYPE DSPU-03 2.0 240/1/50 2.4 --- DUCEDT SPLIT TYPE
SPU-04 2.5 240/1/50 3.0 --- WALL MOUNTED SPLIT TYPE DSPU-04 2.5 240/1/50 3.0 3.0 DUCTED SPLIT TYPE (Head Offices Signature)
DSPU-05 3.0 240/1/50 3.6 9.0 DUCTED SPLIT TYPE
SCHEDULE OF SPLIT TYPE AC AT SECOND BASEMENT DSPU-06 4.0 240/1/50 4.8 --- DUCTED SPLIT TYPE
COOLING CAPACITY POWER SUPPLY POWER CONSUMED SPU-01 1.0 240/1/50 1.2 3.0 WALL MOUNTED SPLIT TYPE
UPDA Reg. No./Grade : 285/A Qatar ID No : 25782802368
Reference Qty REMARKS
NOMINAL (TR) SPU-02 1.5 240/1/50 1.8 --- WALL MOUNTED SPLIT TYPE
V/PH/HZ (KW)
SPU-03 2.0 240/1/50 --- WALL MOUNTED SPLIT TYPE SPU-05 3.0 240/1/50 3.6 --- WALL MOUNTED SPLIT TYPE
2.4
DSPU-02 1.5 240/1/50 1.8 4.0 DUCTED SPLIT TYPE SCHEDULE OF AC'S AT 5th & 6th FLOORS
DSPU-03 2.0 240/1/50 2.4 1.0 DUCEDT SPLIT TYPE
COOLING CAPACITY POWER SUPPLY POWER CONSUMED
DSPU-04 2.5 240/1/50 3.0 1.0 DUCTED SPLIT TYPE Reference QTY REMARKS
NOMINAL (TR) V/PH/HZ (KW)
DSPU-05 3.0 240/1/50 3.6 3.0 DUCTED SPLIT TYPE
DSPU-01 1.0 240/1/50 1.2 3.0 DUCTED SPLIT TYPE
DSPU-06 4.0 240/1/50 4.8 1.0 DUCTED SPLIT TYPE
DSPU-02 1.5 240/1/50 1.8 11.0 DUCTED SPLIT TYPE
SPU-01 1.0 240/1/50 1.2 6.0 WALL MOUNTED SPLIT TYPE
DSPU-03 2.0 240/1/50 2.4 --- DUCEDT SPLIT TYPE PROJECT TITLE
SPU-02 1.5 240/1/50 1.8 --- WALL MOUNTED SPLIT TYPE
DSPU-04 2.5 240/1/50 3.0 3.0 DUCTED SPLIT TYPE
SPU-03 2.0 240/1/50 2.4 --- WALL MOUNTED SPLIT TYPE
DSPU-05 3.0 240/1/50 3.6 9.0 DUCTED SPLIT TYPE
SPU-04 2.5 240/1/50 3.0 --- WALL MOUNTED SPLIT TYPE
DSPU-06 4.0 240/1/50 4.8 --- DUCTED SPLIT TYPE
SPU-05 3.0 240/1/50 3.6 --- WALL MOUNTED SPLIT TYPE
SPU-01 1.0 240/1/50 1.2 2.0 WALL MOUNTED SPLIT TYPE
SCHEDULE OF AC'S AT FIRST FLOOR SPU-03 2.0 240/1/50 2.4 --- WALL MOUNTED SPLIT TYPE
COOLING CAPACITY SPU-04 2.5 240/1/50 3.0 --- WALL MOUNTED SPLIT TYPE
POWER SUPPLY POWER CONSUMED
Reference QTY REMARKS 240/1/50
NOMINAL (TR) SPU-05 3.0 3.6 --- WALL MOUNTED SPLIT TYPE
V/PH/HZ (KW)
PROPOSED(3B+G+10) RESIDENTIAL
DSPU-01 1.0 240/1/50 1.2 3.0 DUCTED SPLIT TYPE
DSPU-02 1.5 240/1/50 1.8 11.0 DUCTED SPLIT TYPE SCHEDULE OF SPLIT TYPE AC AT ROOF FLOOR
DSPU-03
DSPU-04
2.0
2.5
240/1/50
240/1/50
2.4 ---
3.0
DUCEDT SPLIT TYPE
DSPU-05 3.0 240/1/50 3.6 9.0 DUCTED SPLIT TYPE SPU-01 1.0 240/1/50 1.2 2.0 WALL MOUNTED SPLIT TYPE
DSPU-06 4.0 240/1/50 4.8 --- DUCTED SPLIT TYPE SPU-02 240/1/50 1.8 1.0
1.5 WALL MOUNTED SPLIT TYPE
SPU-01 1.0 240/1/50 1.2 3.0 WALL MOUNTED SPLIT TYPE SPU-03 2.0 240/1/50 2.4 --- WALL MOUNTED SPLIT TYPE
SPU-02 1.5 240/1/50 1.8 --- WALL MOUNTED SPLIT TYPE SPU-04 2.5 240/1/50 ---
3.0 WALL MOUNTED SPLIT TYPE
SPU-03 2.0 240/1/50 2.4 --- WALL MOUNTED SPLIT TYPE
DSPU-01 1.0 240/1/50 1.2 3.0 DUCTED SPLIT TYPE Total Area : Street : Plot No. :
DSPU-02 1.5 240/1/50 1.8 11.0 DUCTED SPLIT TYPE