Operating
Operate the safety valve by unscrewing the cap one or two turns and retightening it.
Testing
Before removing the valve, depressurize the compressor. See section Problem solving.
Valve (SV) can be tested on a separate air line. If the valve does not open at the set pressure specified on the
valve, consult Atlas Copco.
Warning
No adjustments are allowed. Never run the compressor without safety valve.
2920 1634 04 97
Instruction book
10 Problem solving
Warning
Before carrying out any maintenance, repair work or adjustment, press the stop button and
wait until the compressor has stopped.
Close the air outlet valve and press the test button on top of the electronic water drain(s)
until the air system between air receiver and outlet valve is fully depressurized.
Press the emergency stop button and switch off the voltage.
Depressurise the compressor by opening the oil filler plug one turn.
For location of components, see sections:
• Introduction
• Condensate system
• Initial start-up
Open and lock the isolating switch.
The air outlet valve can be locked during maintenance or repair as follows:
• Close the valve.
• Remove the screw fixing the handle with the wrench delivered with the
compressor.
• Lift the handle and turn it until the slot of the handle fits over the blocking edge
on the valve body.
• Fit the screw.
The operator must apply all relevant Safety precautions.
Press the test button on top of the electronic water drain(s) until the air system between
air receiver and outlet valve is fully depressurized.
For location of components, see section Condensate system
Wait for at least 6 minutes before starting any electrical repairs as hazardous high voltage
remains on the condensers of the start and speed regulation unit for 6 minutes after
switching off the voltage.
98 2920 1634 04
Instruction book
2920 1634 04 99
Instruction book
11 Technical data
Elektronikon II regulator
Important
The readings mentioned below are valid under the reference conditions (see section
Reference conditions and limitations).
Reference Reading
Air outlet pressure Depends on the setpoint (desired net pressure).
Compressor element Approx. 60 ˚C (108 ˚F) above ambient temperature.
outlet temperature
Dewpoint temperature Approx. 4 ˚C (39 ˚F).
Cooling water outlet Approx. 50 ˚C (122 ˚F).
temperature (on water-
cooled compressors)
Attention
Local regulations remain applicable if they are stricter than the values proposed below.
The voltage drop must not exceed 5% of the nominal voltage. It may be necessary to use
cables of a larger size than those stated to comply with this requirement.
Use the original cable entry. See section Dimension drawings.
The voltage on the compressor terminals must not deviate more than 10% of the nominal
voltage.