523-0806716-001000
This is revision 58 of Service Information Letter (SIL) MDT-3110-1-04 for the MDT-3110
Maintenance Diagnostic Tables.
This revision adds status Rockwell Collins Part Number (CPN) 810-0042-274 and updates
Sections A. and M., Table 2.
DUE TO THE US GOVERNMENT’S IMPLEMENTATION OF EXPORT CONTROL REFORM (ECR), ALL EXPORT DATA PROVIDED
IN THIS PUBLICATION IS CURRENT AS OF THE LAST REVISION DATE AND MAY BE SUBJECT TO CHANGE BY ROCKWELL
COLLINS. THEREFORE, PLEASE BE ADVISED THAT YOU ARE ENCOURAGED TO VALIDATE THE ACCURACY OF THE DATA
PRIOR TO ANY FUTURE EXPORT ACTIVITY RELATING TO THESE PUBLICATIONS.
For each software license procured, the Software License for Equipment Specific Software, reproduced below, shall apply.
Software delivered hereunder, either embedded in equipment described herein or specifically designed for use in or with such
equipment, is copyrighted by the seller and shall remain the sole and exclusive property of seller. Seller grants the buyer a perpetual,
worldwide, non-exclusive license to use the software only in or with the equipment. The buyer shall not copy, modify, or disassemble
the software, or permit others to do so. Buyer shall not transfer the license granted hereby or possession of the software except as part
of or with the equipment, such transfer being subject to the restrictions contained herein. Seller may terminate this license upon written
notice for violation of any of the terms of the foregoing license.
Should the customer have any questions concerning the scope of permitted use, please contact your Rockwell Customer Service Engineer.
Rockwell Collins' General Conditions of Sale 074-8431-866 (Rev 04/15) are incorporated herein by reference.
A. Effectivity
The information in this SIL is applicable to the MDT-3110 Maintenance Diagnostic Tables
listed in the following table.
ROCKWELL COLLINS
UNIT NOMENCLATURE
PART NUMBER
ROCKWELL COLLINS
UNIT NOMENCLATURE
PART NUMBER
ROCKWELL COLLINS
UNIT NOMENCLATURE
PART NUMBER
B. General Information
The Maintenance Diagnostic System (MDS) aids in detecting and troubleshooting aircraft
component problems by monitoring Line Replaceable Units (LRUs) to determine failures,
identifying LRUs requiring replacement and logging information to permit diagnosis of
faults. Along with the system’s ability to provide avionics maintenance diagnostics, the MDS
also provides for electronic checklist functionality. The MDS is made up of two components:
• MDC-3110/4110 – This provides the base hardware functionality for communicating with
other LRUs in the system, controlling data to the display and processing diagnosed faults.
• MDT-3110 – This provides aircraft unique diagnostic data for the base functionality to
operate on to diagnose faults unique to the aircraft type.
NOTE: This service information letter reflects the part number matrix of the MDT and
its corresponding aircraft type. Installation of MDT modified in accordance
with this service information letter requires a change to the aircraft Type
Certificate/Supplemental Type Certificate (TC/STC) data unless the new
equipment part number is already included in the data.
D. Product Identification
F. References
G. Compliance
Optional
(2) Refer to Section M. Compatibility, of this SIL for the specific combinations of software
products that are available.
I. Ordering Information
(1) Approved software products are available for the Rockwell Collins MDT-3110
Maintenance Diagnostic Tables. The MDT-3110 application disks are certified, and
are made from original computer master data files to ensure the highest integrity as
required for these applications.
NOTE: Refer to the compatibility section to determine the software products that
can be installed in the system, and which may not. All currently available
software products are listed.
(3) Orders must include quantity, Rockwell Collins part number, and reference Software
Product Type number.
J. Estimated Effort
The effort required to install the MDT-3110 is estimated to be 30 minutes using the
approved Rockwell Collins data load equipment and procedure.
(2) Data Load rental equipment may be obtained from Rockwell Collins contact:
Rental Exchange Pool, M/S 133-100
Rockwell Collins
400 Collins Road NE
Cedar Rapids, IA 52498
TELEPHONE: 319.295.4361
FAX NO: 319.295.6646
L. Installation Procedure
(1) The MDT-3110 can only be loaded by a certified maintenance mechanic.
(2) Refer to the referenced Field Loadable Software Installation Manual for installation
specifics.
NOTE: If previous red label deliveries of the MDT-3110 occurred during development,
it will be necessary to remove the red Installed Software Label from the target
T/L hardware (MDC-3110 or MDC-4110) following the installation of the TSO
approved MDT-3110 per this SIL.
Verify the data load by using the MDC VERSION INFORMATION pages 2/3 and 3/3.
Compare the data on the pages to the following table and to the label information on the
media containing the data that was loaded.
M. Compatibility
(1) The following Compatibility Matrices should be used to determine the versions of
software that can be installed in the equipment. All currently available loadable
top-level, Field Loadable Software Products for the MDC-3110/4110 are listed. Refer
to Section I.
NOTE: Installation of MDT modified in accordance with this service information letter
requires a change to the aircraft TC/STC data unless the new equipment part
number is already included in the data.
CJ1/CJ2 Bundle
810-0042-072 C292F6FF 06-12-2019 • • • •
Upgrade
CL650/
810-0042-086 D001CF50 03-16-2017 • • • •
CL605 Flex
Hawker 987
810-0042-094 990C177A 08-01-2013 • • • • •
(CD/SVS)
FAA KingAir
810-0042-172 E1CAD680 01-25-2017 • • • •
ACSS TDR
CL350/CL300R HGS
810-0042-274 69CF604E 12-18-2019 •
Update