You are on page 1of 1

M.O.

M
Date: 3-1-2022
Subject: Commissioning Report Joint note.
Customer Name: Inox CVA India pvt ltd

Work Done:
1. Installation of H-beam, rail and gantry doen.
2. All electrical connection done.
3. Trials taken.
4. Resolve A-40 error on drive.
5. Cutting trials done on ss 4mm, 8mm, 16mm thickness plate.

Note:

1. currently machine under observation.


2. Customer will connect UPS and let us know feedback regarding random vibration at random
time and place.

Darshil Shah

Fine cut engineering Services.