Air Quality Monitor

5S & 2S Models
PRODUCT CATALOGUE

www.envirosuite.com
Table of contents
About Envirosuite..................................................................................................................... 4
Environmental intelligence solutions................................................................................ 6
Air Quality Monitor 5S............................................................................................................. 8
Air Quality Monitor 2S............................................................................................................. 10
Smart gas cartridges.............................................................................................................. 13
What we do different.............................................................................................................. 14
Evidences of accuracy........................................................................................................... 15
Pollutants
Carbon Monoxide................................................................................................................ 17
Carbon Dioxide..................................................................................................................... 18
Sulphur Dioxide..................................................................................................................... 19
Nitric Oxide............................................................................................................................ 20
Volatile Organic Compounds............................................................................................ 21
Ammonia................................................................................................................................ 22
Nitrogen Dioxide................................................................................................................... 23
Particulate Matter................................................................................................................ 24

Technical specs........................................................................................................................ 28
Power packs.............................................................................................................................. 30
Installation process................................................................................................................. 31

www.envirosuite.com 02 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 03 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Envirosuite is the world’s most Our Purpose Our Vision Our Mission

advanced environmental We believe


environmental
We harness the power
of environmental
To create world-leading,
science-based technology
intelligence technology provider intelligence is the
key to improving the
intelligence so
industries grow
to help our customers act
faster, perform better and
wellbeing of people sustainably and realise their full potential
and the planet. communities thrive. with environmental
intelligence.

OUR DIFFERENCE WHAT WE DO PRODUCTS VALUE

SCIENCE BUILT-IN
An advanced environmental
BUILT FOR TODAY WITH
intelligence portfolio that embeds
TOMORROW'S OUTCOMES
decades of science, innovation
through expertise and complex IN MIND
EVS Omnis
ABOR ATE
modelling, all made simple for users.
C O LL Optimise operational
Powerful software built outcomes, increase production,
COMMITMENT TO CUSTOMERS make tangible cost savings and
We put customers at the heart
for industrial facilities to build social licence to operate
of what we do to build long- Collaborating with act on emissions, plan with surrounding communities.
lasting, trusted relationships and industry, regulators for operational risks and
expand this to our partners and and communities RAPID RESPONSE AND
engage with stakeholders.

IN
IC

stakeholders. to solve complex ENGAGEMENT

NO
ST

environmental
Easy-to-use, location-specific
O

We are agnostic, challenges. We design, build

VAT
HUMAN INGENUITY,
AGN

ENVIRONMENTAL partnering with and provide secure, public portals to educate and
a variety of science-based EVS Water engage with communities

ION
TECHNOLOGY technologies to environmental and stakeholders, including
Our global team is made up of give our customers intelligence software observation submissions to
talented, passionate domain experts flexibility and choice. and IoT platforms. Digital twin technology for
foster transparent two-way
who are driven by a collective water treatment powered communication.
purpose and empowered to offer
by machine learning and
their unique contribution everyday. UNLOCK VALUE BEYOND
Domain Our customers deterministic modelling.
knowledge and are empowered to COMPLIANCE
ESG ENABLING, expertise across monitor, predict
SDG ADVANCING air, dust, odour, and mitigate their Harness predictive insights
Society demands measurable, noise, vibration operational impact. from the environmental
sustainable performance. Our and water. monitoring network to avoid
EX

technology supports ESG criteria EVS Aviation unwanted impacts and keep
RT
PE

production moving.
RE

and advances the SDG agenda, S A


serving the interests of all F TW World leading software ENVIRONMENTAL INTELLIGENCE
stakeholders and our shareholders. SO and hardware built for REIMAGINES RISK
LEADING ENVIRONMENTAL solving complex challenges Our technology empowers
INTELLIGENCE from airport noise, aircraft organisations to unleash
The world's most advanced innovation and continuous
tracking and community improvement, enhancing
environmental intelligence solutions
for Aviation, Waste, Wastewater, engagement. operational efficiencies while
Water Treatment, Mining & Industrial building community trust.

PRODUCT INSIGHTS CUSTOMER FEEDBACK

www.envirosuite.com 04 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 05 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Environmental
intelligence 24/7 Proactive air
solutions quality management
EVS Omnis is a cloud-based solution that enables
operators to integrate environmental intelligence
into day-to-day operations to mitigate risk, impro-
ve operational safety and keep production moving.
Powered by Kunak, our hyperlocal air quality mo-
nitors are designed to collect real-time information
across multiple parameters. Data feeds directly
into our EVS Omnis platform and is combined with
Envirosuite’s proprietary algorithms to provide
actionable insights for users to proactively manage
site-generated emissions at their operations.

One cloud-based platform, multiple toolsets

Act Plan Engage


Act on advanced insights to Plan operations around Engage transparently with
mitigate site emissions with emissions risk with hyperlo- stakeholders and shorten
real-time air quality moni- cal weather forecasts and air investigation time of comp-
toring, threshold alerts and quality impact modelling. laints with highly accurate air
powerful visualisation. quality modelling.

www.envirosuite.com 06 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 07 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Air Quality Monitor 5S Optical particle counter

Solar shield
Built-in sensors

An air quality monitoring IP65 protection


station for professionals Smart gas
cartridges

SENSOR BASED | BEST AVAILABLE ACCURACY

The Air Quality Monitor 5S offers an evolution to Temperature, hu-


sensor-based air quality monitoring stations. It midity, dew point
is designed to solve all the lifecycle challenges and pressure
sensors
of a sensor-based air quality monitoring product ON/OFF button
including operation and maintenance.
Its multipollutant cutting-edge design includes
environmental sensors as well as connectors for
external weather sensors or probes. Real-time LCD display
wireless data transmission enables proactive air Power supply
quality management for any environmental pro-
ject using the cloud based EVS Omnis platform.
Fixing bolts

Multiple connectors for


external sensors

Specifications
Easy & Fast Cartridges Proven Dimensions 257 x 270 x 225 mm Gas sensors CO, CO2, NO, NO2, O3, SO2, H2S, NH3 & VOCs
installation system accuracy
Weight <3.5 kg PM sensor PM1, PM2.5, PM4, PM10 TSP and TPC

Set up in less than 10 minutes Replace and combine pollutant Proven as the best-in-class Enclosure
PMMA & Polycarbonate &
Internal status
Temperature | Battery | Charging voltage &
with visual diagnosis in a built- sensors with a plug & play system by independent Stainless steel current | Signal
in display. system. organizations. Operating temp -20 ºC to 60ºC Temperature | Humidity | Atmospheric pres-
Built-in sensors
sure | Dew point
Operating RH 0 to 99 %RH
Sampling freq. 3Hz gases, 0.25Hz particles
IP rating IP65
Avg. periods From 10 seconds to a maximum of 24 hours
EVS Omnis Easy to use Multi Battery Lithium 2.9Ah or 26 Ah
Sending periods From 5 minutes to a maximum of 24 hours
platform software pollutant External supply
7 - 12 Vdc. charger or solar
panel Remote Bidirectional communications. Remote confi-
Visualise, analyse and manage management guration and calibration
EVS Omnis can be Measure up to 5 gases and Autonomy 24/7 with charger or solar panel
your data in the cloud. used by specialists and particulate matter at once. SIM Embedded eSIM and SIM holder
0.08 - 1.2W (depending on
non-specialists. Power consumption
configuration)

Communications Multi-Band 2G/3G/4G

GNSS GPS and GLONASS


Fully Real-time Add environmental
autonomous data sensors
Autonomous operation with Access to your data and alar- Connect wind, rain, noise, and
its built-in battery and solar ms in real-time. other sensors. Communications
panel.
GSM GPRS 2G 3G 4G Lte

www.envirosuite.com 08 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 09 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Air Quality Monitor 2S
Built-in sensors
Solar shield

IP65 protection
A compact air quality station Smart gas
for hyperlocal monitoring cartridges

INDUSTRY GRADE DESIGN | HIGH ACCURACY

The Air Quality Monitor 2S is based on the same princi-


ON/OFF button
ples as the Air Quality Monitor 5S and also incoproates
same smart gas cartridge technology. Temperature, humi-
dity, dew point and
Similar to the Air Quality Monitor 5S, it is designed for pressure sensors
harsh environments. Its cutting-edge design includes
two environmental sensors as well as connectors for
external weather sensors or probes. Real-time wireless
data transmission enables proactive air quality mana- OLED display
gement for any environmental project using the cloud Power supply
based EVS Omnis platform.

Main applications:

• Industrial fenceline monitoring


• Massive city deployments Connector for
• Leakage detection external sensors Fixing bolts

• Wastewater management
• Landfill monitoring

Specifications
Gas sensors CO, CO2, NO, NO2, O3, SO2, H2S, NH3 & VOCs
Dimensions 200 x 153 x 185 mm

Application ba- Built-in Best Weight <2.3 kg


Internal status
Temperature | Battery | Charging voltage &
current | Signal
sed design display accuracy Enclosure
PMMA & Polycarbonate &
Stainless steel Temperature | Humidity | Atmospheric pres-
Built-in sensors
sure | Dew point
Select your targeted pollutants Easy installation and on field Get the most reliable and accu- Operating temp -20 ºC to 60ºC
for industrial monitoring or diagnosis thanks to its embe- rate data without the need of Sampling freq. 3Hz gases, 1Hz particles
Operating RH 0 to 99 %RH
massive deployments in cities. dded display. additional external instruments. SIM Embedded eSIM and SIM holder
IP rating IP65
Battery Lithium 2.9Ah or 20 Ah
Cost Cartridges Easy data 7 - 12 Vdc. charger or 6 Vdc. solar
External supply
effective system integration panel
Autonomy 24/7 with charger or solar panel
Get the most accurate technolo- Replace and combine Local wired integration through
gy at a fair cost. pollutant sensors with a plug slave MODBUS RTU or via API Power consumption
0.08 - 0.55W (depending on
configuration)
& play system. through the cloud.
Communications Multi-Band 2G/3G/4G

Rugged & Targeted Fully GNSS GPS and GLONASS

Compact design pollutants autonomous


The smallest air quality solution
designed for harsh environ-
Measure up to 2 gases
and particulate matter at
Autonomous operation with its
built-in battery and solar panel.
Communications
ments (IP65 & IK08). once.
GSM GPRS 2G 3G 4G Lte

www.envirosuite.com 10 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 11 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Smart gas cartridges
Description
Both air quality monitors are sensor-based devices equipped with slots to insert smart gas cartridges.
Smart gas cartridges solve many of the known issues of sensor technology: sensor variability, factory and
field calibration, automatic data invalidation, sensor replacement, network operation and maintenance
work.
Smart gas cartridges ensure measurement control throughout the life cycle of each sensor, making both air
quality monitors more sustainable and our customers' lifes easier.

Traceable Endless Plug & More


QC & QA combinations Play sustainable

Each cartridge is cali- Combine the parameters Simply take the old one The electronic and me-
brated and validated in- freely. Reuse and scale out and replace easily chanical parts can be
dividually in lab against your basestations at with the new one, on reused, making it the
traceable reference your own pace. field. Be back online in most sustainable AQ
standards. 2'. sensor- based station in
the market.

GasPlug TM technology (patent pending)


All the cartridges have the same size and fit in any of the available sockets. Inside the cartridge, we install
the sensor into a PCB that stores its all information: type, age and factory calibration. When you insert the
new cartridge, the basestation reads the information, configures itself and starts working.

You cannot improve


what you cannot
measure

www.envirosuite.com 12 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 13 | Product Catalogue: Air Quality Monitor 5S & 2S Models
What we do different Evidence of Accuracy
We continuously conduct intercomparative studies with reference stations in different locations and labo-
Quality Control & Quality Assurance cycle ratories to guarantee the highest quality results.

Sensor 01. Sensors are factory assessed to ensure the R2 RL MAE U(exp) % R2 RL MAE U(exp) %
selection good operation of each sensor. CO 0.95 Y=1.01*X - 26.89 41.6 10.22
NO 0.95 Y=0.98*X - 0.25 2.16 7.28

02. Each cartridge with its individual elec-

STOCKHOLM, SWEDEN
MEXICO CITY, MEXICO
tronics are characterized under specific
environmental conditions

03. (laboratory) Kunak Calibration* against


reference standards.
Cartridges
replacement 04. Validation of the laboratory calibration

LABORATORY
against Kunak gold standards correctly
maintained with reference AQMS. Kunak
algorithm uses the reference data for vali-
FIELD

dation, not for calibration, to guarantee the


best available accuracy.

Operation & Cartridges


FIELD DEPLOYMENT
Maintenance calibration Air Quality Monitor 5S Air Quality Monitor 5S
Reference station Reference station
05. Sensors have a 2 year life. The Envirosuite
team and technology platform remotely
self-monitors all in-service instruments to R2 RL MAE U(exp) % R2 RL MAE U(exp) %
quickly identify outages and issues with NO2 O3
measurements in accordance with the 0.94 Y=0.85*X - 1.84 2.11 21.54 0.95 Y=1.02*X - 1.11 1.99 17.42
FIELD service level agreement.
DEPLOYMENT

BARCELONA, SPAIN
Cartridges 06. Once the sensor arrives to its end of life,

MANCHESTER, UK
validation cartridges are returned to Envirosuite
and the electronics are recycled for new
cartridges.

Onboard algorithm Benefits


Air Quality Monitor 5S & 2S models use onboard • Calibrate the cartridge for any condition.
sensors and Kunak embedded algorithm that cal-
Air Quality Monitor 5S Air Quality Monitor 5S
Reference station Reference station
culates the concentrations in ppb or μg/m3 locally • Real-time compensation of temperature effects.
and in real-time, not using or needing exter- R2 RL MAE U(exp) % R2 RL MAE U(exp) %
• Traceable QC&QA and option Modbus RTU local PM10 PM2.5
nal reference data to calculate gas or particle 0.77 Y=1.10*X - 2.00 3.53 38.51 0.9 Y=1.08*X - 1.17 1.97 22.19
output.
concentrations.

ANTWERP, BELGIUM

ANTWERP, BELGIUM
An algorithm corrects the interferences and ar- • Not dependant on nearby stations.
tifacts typically found in raw data, compensating
environmental effects like temperature, humidity
and pressure (depending on the cartridge), as well
as cross-sensitivities using onboard data.

Remote calibration of a linear response Air Quality Monitor 5S Air Quality Monitor 5S
Reference station Reference station

For most of the cartridges temperature, humidity and crosssensitivities effects have a nonlinear response
in the sensor raw data which are corrected by an algorithm converting the nonlinear response into a linear
response.
The most acurrate multi-pollutant sensor
Gas Particulate matter

Mass Factor
correction
Sp

Raw
data
Kunak PM correc- “It provides excellent quality for PM1, “Sensor nodes have very small form “The three sensors showed an absolute
Zero
value
correction ted data
very good quality for PM2.5, PM10, and factor and weight that are practical intra-model variability of 0.32 ppb, 0.33
O3, and good quality for NO2 and NO, for response field deployments.” ppb and 0.002 ppm for O3, NO2 and CO
being the best performing sensor for measurements, respectively.”
this latter pollutant.”

www.envirosuite.com 14 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 15 | Product Catalogue: Air Quality Monitor 5S & 2S Models
CO

Carbon
monoxide

Where is it found? How does EVS Omnis help?


CO is found in fumes produced any time fuel burns The EVS Omnis platform enables proactive mana-
in cars or trucks, small engines, stoves, lanterns, gement of Carbon Monoxide (CO) emissions. It is
grills, fireplaces, gas ranges, or furnaces. designed to be used by specialists and non-spe-
cialists alike to maintain compliance with actiona-
Improperly ventilated appliances and engines, par-
ble insights from powerful visualisation, analytics,
ticularly in a tightly sealed or enclosed space, may
prediction and reporting.
allow carbon monoxide to accumulate until dange-
rous levels. No other platforms offer the same level of scientific
and technological excellence in such a user-friend-
ly, practical form to benefit ambient air quality
monitoring programs at your operations.

CO cartridge
(A) K-CO-A-01 / (B) K-CO-B-01

The Carbon Monoxide Cartridge has a built-in electrochemical sensor with very
low noise electronics allowing the measurement from very low concentrations
(ppb) up to several ppm. To cover different applications, there are two measu-
rement ranges: Type A measuring most common concentrations range, and
Type B, a higher range version that can measure up to 500 ppm, decreasing
the accuracy at low concentrations.
This cartridge is very stable over time with a lifespan that can go beyond the
specification for several months under no extreme environments.

Reliable real-time Technical specifications


Type Electrochemical 10 ppb(A)

information on
Limit of Detection (LOD)(7)
0.02 ppm(B)
µg/m³, ppb(A)
Unit of measurement 20 ppb(A)
mg/m³, ppm(B) Repeatability(8)
0.05 ppm(B)
0 - 12,000 ppb(A)

emissions
Measurement range(1) < 30 sec(A)
0 - 500 ppm(B) Response time(9)
< 180 sec(B)
1 ppb(A)
Resolution(2) ± 80 ppb(A)
0.01 ppm(B) Typical accuracy (MAE)(10)
± 0.1 ppm(B)
Operating temperature range(3) -30 to 50 ºC
Typical precision R² (10) > 0.85
Operating RH range(4) 0 to 99 %RH
Typical slope(10) 0.78 - 1.29
Recommended RH range(4) 15 to 90 %RH
-50 ppb ≤ a ≤ +50 ppb(A)
Typical intercept (a)(10)
Operating life(5) > 24 months -0.1 ppm ≤ a ≤ +0.1 ppm(B)
Guarantee range(6) 1,000 ppm DQO - Typical U(exp)(11) < 20%
< 3 ppb(A)
Typical Intra-model variability(12)
< 0.05 ppm(B)

www.envirosuite.com 16 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 17 | Product Catalogue: Air Quality Monitor 5S & 2S Models
CO2 NO

Carbon Nitric
dioxide oxide

Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
CO2 is a result of normal cell function when it is It’s difficult to achieve situational awareness of Nitrogen oxide is emitted from automotive engines The EVS Omnis platform can be used by specialist
breathed out of the body. Besides, it is an essential Carbon Dioxide (CO2) levels and know when you and the burning of coal, oil, diesel fuel, and natural and non-specialists to proactively manage air quality
element in photosynthesis, the process by which are operating within thresholds with a traditional air gas, specially from electric power plants. It is also emissions such as Nitric Oxide (N0). Users are em-
plants make food and energy. Levels of atmospheric quality monitoring system. emitted by cigarettes, gas stoves, wood burning, powered with actionable insights to mitigate pro-
CO2 have increased since the Industrial Revolution. and silos that contain silage. blematic N0 emissions with powerful visualisation,
EVS Omnis empowers your operation with actiona-
The primary causes are deforestation and the bur- analytics, prediction and reporting.
ble insights to proactively manage CO2 emissions at
ning of fossil fuels such as coal, for electricity, heat
a site-level.
production and for transportation (cars, ships, pla-
nes, etc.). It could also be formed, as a secondary
pollutant, by CO oxidation.

CO2 cartridge NO cartridge


K-CO2-B-01 K-NO-A-01

The Carbon Dioxide Cartridge has a built-in non-dispersive infrared sensor The Nitric Oxide Cartridge has a built-in electrochemical sensor ideal to mea-
(NDIR) ideal to measure from low to high concentrations that can be found in sure from very low ppb concentrations up to several ppm than can be found in
the atmosphere. Besides, it includes an automatic baseline calibration to main- the atmosphere close to pollution sources (vehicles, industries…). This cartrid-
tain the long-term stability with no effect of humidity, temperature and pressu- ge is very accurate and stable with very good temperature correction algorithm
re, which are corrected in the algorithm. and can work beyond two years easily under no extreme environments. The
cartridge can suffer from a small zero drift (some ppbs) over time thatcan be
easily corrected with a remote calibration tool.

Technical specifications Technical specifications

Type NDIR Response time(9) < 30 sec Type Electrochemical Limit of Detection (LOD)(7) 2 ppb
Unit of measurement mg/m³, ppm Typical accuracy (MAE) (10)
± 30 ppm Unit of measurement µg/m³, ppb Repeatability (8)
4 ppb
Measurement range (1)
0 - 5,000 ppm Measurement range (1)
0 - 5,000 ppb Response time (9)
< 30 sec
Resolution (2)
1 ppm Resolution(2)
1 ppb Typical accuracy (MAE) (10)
± 4 ppb
Operating temperature range (3)
-20 to 50 ºC Operating temperature range (3)
-30 to 40 ºC Typical precision R² (10)
> 0.9
Operating RH range (4)
0 to 99 %RH Operating RH range (4)
0 to 99 %RH Typical slope (10)
0.9 - 1.12
Recommended RH range (4)
15 to 95 %RH Recommended RH range (4)
15 to 85 %RH Typical intercept (a) (10)
-2 ppb ≤ a ≤ +2 ppb
Operating life (5)
> 7 years Operating life (5)
> 24 months DQO - Typical U(exp) (11)
< 20%
Guarantee range (6)
20 ppm Typical Intra-model variability (12)
< 1 ppb

www.envirosuite.com 18 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 19 | Product Catalogue: Air Quality Monitor 5S & 2S Models
NO2 O3

Nitrogen Ozone
dioxide

Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
The major source of NO2 is combustion of fossil Managing Nitric Dioxide (NO2) emissions requires a Ozone (O3) is found in the troposphere and it is the The EVS Omnis platform offers a proactive air
fuels: coal, oil and gas. Most of the NO2 in cities is bird's eye view of real-time monitoring data, local result of the atmospheric reaction of a number of quality management solution for parameters such
derived from motor vehicle’s exhausts. Other sour- weather conditions and accurate insights on what's precursor pollutants, which come from both natural as Ozone (O3) emissions. The cloud-based sof-
ces of NO2 are petrol and metal refining, electricity next. The EVS Omnis platform empowers your ope- and man-made sources. Precursor pollutants are tware is designed to empower your operation with
generation from coal-fired power stations, other ration with actionable insights through data capture originated by human activities and include hy- actionable insights through powerful visualisation,
manufacturing industries and food processing. from air quality monitoring devices, visualisation, drocarbons and nitrogen oxides. They are largely analytics, prediction and reporting.
analytics, prediction and reporting. emitted by cars and other vehicles, fossil fuel power
No other platforms offer the same level of scientific
plants, oil refineries, the agriculture sector and a
and technological excellence in such a user-friend-
number of other industries.
ly, practical form to benefit ambient air quality
monitoring programs.

NO2 cartridge O3 cartridge


K-NO2-A-01 K-O3-A-01

The Nitrogen Dioxide Cartridge has a built-in electrochemical sensor which has The Ozone cartridge has a built-in electrochemical sensor that detects NO2
no interference with Ozone thanks to its embedded O3 filter, making the cartri- and O3 concentration. Then, to measure accurately the O3 concentration, it is
dge ideal to measure the concentrations found in the atmosphere, from very low required to have installed in the same device the NO2 Cartridge. Thus, thanks
levels in clean environments to high concentrations in polluted areas of cities or to an algorithm, it is possible to deliver accurate measurements of Ozone, with
industries. However, the cartridge can be affected by fast humidity transients no NO2 influence, even at high temperature which are related to higher O3 con-
reducing its accuracy during these events. centration due to the sun radiation.

Technical specifications Technical specifications


Type Electrochemical Limit of Detection (LOD)(7) 2 ppb Type Electrochemical Limit of Detection (LOD)(7) 3 ppb
Unit of measurement µg/m³, ppb Repeatability(8) 4 ppb Unit of measurement µg/m³, ppb Repeatability(8) 4 ppb
Measurement range(1) 0 - 5,000 ppb Response time(9) < 60 sec Measurement range(1) 0 - 2,000 ppb Response time(9) < 70 sec
Resolution(2) 1 ppb Typical accuracy (MAE)(10) ± 5 ppb Resolution(2) 1 ppb Typical accuracy (MAE)(10) ± 8 ppb
Operating temperature range(3) -30 to 40 ºC Typical precision R² (10) > 0.85 Operating temperature range(3) -30 to 40 ºC Typical precision R² (10) > 0.9
Operating RH range(4) 0 to 99 %RH Typical slope(10) 0.78 - 1.29 Operating RH range(4) 10 to 99 %RH Typical slope(10) 0.85 - 1.18
Recommended RH range(4) 15 to 85 %RH Typical intercept (a)(10) -4 ppb ≤ a ≤ +4 ppb Recommended RH range(4) 15 to 85 %RH Typical intercept (a)(10) -3 ppb ≤ a ≤ +3 ppb
Operating life(5) > 24 months DQO - Typical U(exp)(11) < 25% Operating life(5) > 24 months DQO - Typical U(exp)(11) < 20%
Guarantee range(6) 20 ppm Typical Intra-model variability(12) < 1 ppb Guarantee range(6) 20 ppm Typical Intra-model variability(12) < 1 ppb

www.envirosuite.com 20 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 21 | Product Catalogue: Air Quality Monitor 5S & 2S Models
H2S SO2

Hydrogen Sulphur
sulfide dioxide

Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
Most of this gas present in the atmosphere has EVS Omnis software gives you the tools to mana- Sulfur Dioxide (SO2) is invisible and has a nas- Knowing when you are operating within Suphur
natural origin by the organic matter decomposi- ge Hydrogen Sulfide (H2S) quickly and efficiently: ty smell. It is produced by the combustion of any Dioxide (S02) thresholds limits can be the difference
tion. Anthropically, it occurs in processes in which real-time monitoring, advanced analytics emissions substance that contains sulfur. The main source between staying operational and shutting down.
sulphur compounds and organic matter are invol- modelling, and effective community complaints ma- of SO2 in the atmosphere comes from combus-
EVS Omnis can visualise real-time S02 emission
ved at high temperatures. Some industrial activities nagement are all easily accessible on our intuitive tion of coal or fossil fuels while small sources are
levels, when you run the risk of exceedance and
that emit this gas are paper pulp manufacturing, platforms. in metallurgy and naturally by volcanic eruptions.
exactly where you should focus mitigation efforts.
oil refining, water treatment plants and the viscose Locomotives, ships and other vehicles that burn
Smart alerting from your environmental monitoring
manufacturing textile industry. fuel with a high sulfur content are other emission
network to know when to boost production during
source. Besides, it can react with other compounds
safe times and when to schedule other activities.
in the atmosphere contributing to particulate matter
pollution.
H2S cartridge
(A) K-H2S-A-01 / (B) K-H2S-B-01

The Hydrogen Sulfide cartridge has a built-in electrochemical sensor very SO2 cartridge
sensitive to its specific pollutant allowing the sensor to detect any change in K-SO2-A-01
H2S concentrations. This cartridge responds and detects Methyl Mercaptan
(CH4S). To cover different applications, there are 2 measurement ranges: Type The Sulfur Dioxide Cartridge has a built-in electrochemical sensor which
A: detect low ppb concentrations in real environments. Although an algorithm presents high cross-sensitivities with O3 and NO2. When used together with
corrects well the temperature variations, it is not recommended to use this the NO2 and O3 cartridges, an algorithm is capable of correcting from these
cartridge to detect levels below 10 ppb. cross-sensitivities improving the accuracy of the measurements. However, it
is not recommended for outdoors application requiring accurate SO2 measure-
Type B: a higher range version that can measure up to 20 ppm, decreasing the ments at very low concentrations (<20 ppb).
accuracy at low concentrations.

Technical specifications Technical specifications


Type Electrochemical 2 ppb(A) Type Electrochemical Limit of Detection (LOD)(7) 3 ppb
Limit of Detection (LOD)(7)
0.01 ppm(B)
µg/m³, ppb(A) Unit of measurement µg/m³, ppb Repeatability(8) 5 ppb
Unit of measurement
mg/m³, ppm(B) 4 ppb(A)
Repeatability(8) Measurement range (1)
0 - 10,000 ppb Response time(9) < 60 sec
0.01 ppm(B)
0 - 2,000 ppb(A)
Measurement range(1) Resolution (2)
1 ppb Typical accuracy (MAE)(10) ± 15 ppb
0 - 20 ppm(B) Response time(9) < 60 sec
1 ppb(A) ± 10 ppb(A)
Operating temperature range (3)
-30 to 40 ºC Typical precision R² (10) > 0.7
Resolution(2) Typical accuracy (MAE)(10)
0.01 ppm(B) ± 0.05 ppm(B) Operating RH range (4)
0 to 99 %RH Typical slope(10) 0.78 - 1.29
Operating temperature range(3) -30 to 50 ºC Typical precision R² (10) > 0.8 Recommended RH range (4)
15 to 90 %RH Typical intercept (a)(10) -5 ppb ≤ a ≤ +5 ppb
Operating RH range(4) 0 to 99 %RH Typical slope(10) 0.78 - 1.29 Operating life (5)
> 24 months DQO - Typical U(exp)(11) < 25%
Recommended RH range(4) 15 to 90 %RH -2 ppb ≤ a ≤ +2 ppb(A) Guarantee range (6)
100 ppm Typical Intra-model variability(12) < 3 ppb
Typical intercept (a)(10)
-0.02 ppm ≤ a ≤ +0.02 ppm(B)
Operating life(5) > 24 months
Typical Intra-model < 2 ppb(A)
Guarantee range(6) 100 ppm variability(12) < 0.02 ppm(B)

www.envirosuite.com 22 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 23 | Product Catalogue: Air Quality Monitor 5S & 2S Models
NH3 VOCs

Ammonia Volatile Organic


Compounds

Where is it found? How does EVS Omnis help? Where is it found? How does EVS Omnis help?
Ammonia (NH3) is a colourless gas with a pungent The EVS Omnis platform can be used by specia- Volatile Organic Compounds (VOCs) can be produ- EVS Omnis can visualise real-time VOC emission
odour that can be detected by humans at 0.4-1 list and non-specialists to proactively manage air ced by fuel combustion (wood, coal, gasoline etc.) levels and alert of you of when you run the risk of
ppm, being the exposure limit 50 ppm. NH3 is origi- quality emissions such as Ammonia (NH3). Users are such as mobile sources and industries. They can be exceedance. Predictive modelling combined with
nated from both natural and anthropogenic sources, empowered with actionable insights to mitigate pro- released to the atmosphere due to gasoline, paint, hyperlocal weather forecasts can let you know
being the main source agriculture (fertiliser applica- blematic NH3 emissions with powerful visualisation, and solvents evaporation from above ground stora- exactly where you should focus mitigation efforts
tion and fabrication) and live- analytics, prediction and reporting. ge tanks. Another of the most important emission while enabling you to plan for periods of high risk.
stock (manure management), followed by the waste sources is biogenic, by vegetation natural release.
and water management (slurries, composting and
landfills). Other sources are household and indus-
trial cleaners, that can affect directly to humans
exposed to them. VOCs cartridge
(A) K-VOCs-A-01 / (B) K-VOCs-B-01

The Volatile Organic Compounds Cartridge has a built-in photoionization detec-


NH3 cartridge tor (PID) sensor provided with a 10.6 eV light energy source to measure accu-
K-NH3-A-01 rately hundreds of VOCs commonly found in indoor and outdoor environments.
Its cutting-edge design avoids any undesirable humidity effect, giving 10,000
The Ammonia cartridge has a built-in electrochemical sensor capable of mea-
hours of continuous operation.
suring from low to high concentrations with a typical noise below 0.1 ppm when
the ambient temperature is under 25ºC. The Cartridge presents cross-sensi- To cover different applications, there are 2 measurement ranges: Type A: de-
tivities with NO2, O3, Cl2 and SO2 that can be negligible in most applications. tect low ppb concentrations in real environments. Kunak algorithm corrects the
However, it also presents cross-sensitivity to H2S, which is quite relevant be- temperature, humidity and pressure variations allowing accurate measurements
cause they can co-exist and both measurements can be essential for the same from very low concentrations (<5 ppb) up to >3 ppm, with very low variability
purpose. That's why, it is recommended to use it together with the H2S cartrid­ between sensors. Type B: a higher range version that can measure up to 40
ge, which allows an algorithm to correct from this cross- sensitivity. ppm, decreasing the accuracy at low concentrations (<1 ppm).

Technical specifications
Technical specifications Limit of Detection (LOD)(7)
1 ppb (A)
Type Photoionization detector 0.01 ppm (B)
Type Electrochemical Limit of Detection (LOD)(7) 0.1 ppm µg/m³, ppb (A) 5 ppb (A)
Unit of measurement Repeatability(8)
mg/m³, ppm (B) 0.02 ppm (B)
Unit of measurement mg/m³, ppm Response time(9) < 45 sec
0 - 3,000 ppb (A) < 12 sec (A)
Measurement range(1) 0 - 50 ppm Typical accuracy (MAE)(10) ± 0.3 ppm Measurement range(1) Response time(9)
0 - 40 ppm (B) < 10 sec (B)
Resolution(2) 0.01 ppm Typical Intra-model variability(12) < 0.1 ppm
1 ppb (A) ± 10 ppb (A)
Resolution(2) Typical accuracy (MAE)(10)
Operating temperature range(3) -10 to 50 ºC 0.01 ppm (B) ± 0.1 ppm (B)
Operating RH range(4) 0 to 99 %RH Operating temperature range(3) -40 to 60 ºC Typical precision R² (10) > 0.99
Recommended RH range(4) 15 to 90 %RH Operating RH range(4) 0 to 99 %RH Typical slope (10)
0.99 - 1.002
Operating life(5) > 24 months Recommended RH range(4) 0 to 99 %RH -9 ppb ≤ a ≤ +9 ppb (A)
Typical intercept (a)(10)
Operating life(5) 10,000 hours -0.08 ppm ≤ a ≤ +0.08 ppm(B)
Guarantee range(6) 100 ppm
Typical Intra-model < 3 ppb (A)
50 ppm (A)
Guarantee range(6) variability(12) < 0.1 ppm (B)
60 ppm (B)

www.envirosuite.com 24 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 25 | Product Catalogue: Air Quality Monitor 5S & 2S Models
PM1
PM2.5
PM4
Particulate PM10
TSP
Matter TPC

Where is it found? Technical specifications


Particles are emitted from a wide range of man-made sources. The most significant are road transport,
non-combustion processes, industrial combustion plants and processes, commercial and residential com- Type A
bustion and power plants. Natural sources are less important and include volcanoes and dust storms. (only for Air Quality Monitor 5S)

Type Optical particle counter 0.5 µg/m³ (PM1)


0.5 µg/m³ (PM2.5)
Unit of measurement µg/m³ Limit of Detection (LOD)
How does EVS Omnis help? 0 - 1,000 µg/m³ (PM1)
(7) 0.5 µg/m³ (PM4)
1 µg/m³ (PM10)
0 - 2,000 µg/m³ (PM2.5) 1 µg/m³ (TSP)
Even problematic levels of particles can be invisible. Mitigating particulate matter (PM) issues requires 0 - 2,000 µg/m³ (PM4)
Measurement range(1) ± 2 µg/m³ (PM1)
information: not just enough to know that there is an issue, but enough to know how to focus the action 0 - 10,000 µg/m³ (PM10)
± 3 µg/m³ (PM2.5)
efficiently on the cause of the problem. 0 - 15,000 µg/m³ (TSP) Typical accuracy (MAE)
(10) ± 3 µg/m³ (PM4)
0 - 8,000 counts/cm³ (TPC)
± 4 µg/m³ (PM10)
EVS Omnis provides situational awareness to support effective mitigation of PM emissions. Advanced insi-
1 µg/m³ ± 6 µg/m³ (TSP)
ghts help you act on unfolding PM events in real-time, plan for periods high risk using air quality modelling Resolution(2)
1 count/cm³ (TPC)
powered by hyperlocal weather forecasts and diagnose problematic sources of emissions. > 0.9 (PM1)
Operating temperature range (3)
-10 to 50 ºC > 0.8 (PM2.5)
> 0.8 (PM4)
Operating RH range (4)
0 to 99 %RH Typical precision R² (10)
> 0.7 (PM10)

PM sensor Recommended RH range(4) 0 to 95 %RH > 0.7 (TSP)


> 0.8 (TPC)
Operating life (5)
> 24 months
Typical slope(10) 0.85 - 1.18
2 µg/m³ (PM1)
The Particulate Matter sensor consists on an Optical Particle Counter (OPC). To cover different applica- -1.8 µg/m³ ≤ a ≤ +1.8 µg/m³ (PM1)
3 µg/m³ (PM2.5)
tions, a particle sensor is available: Repeatability(8) 3 µg/m³ (PM4) -2 µg/m³ ≤ a ≤ +2 µg/m³ (PM2.5)
5 µg/m³ (PM10) Typical intercept (a)(10) -2 µg/m³ ≤ a ≤ +2 µg/m³ (PM4)
• Type A (specific for Air Quality Monitor 5S): an OPC capable of measuring particles from 0.3 µm up to 40 -3 µg/m³ ≤ a ≤ +3 µg/m³ (PM10)
6 µg/m³ (TSP)
µm. Then, the PM1, PM2.5, PM4, PM10, Total Suspended Particles (TSP) and Total Particle Counter (TPC) -4 µg/m³ ≤ a ≤ +4 µg/m³ (TSP)
are calculated assuming a particle density profile. Field co-location studies have shown that the expec- Response time(9) < 10 sec
DQO - Typical U(exp)(11) < 50%
ted field performance is comparable to Palas Fidas 200 equivalent instrument.
Typical intra-model
The effect of humidity is perfectly corrected with the embedded algorithm achiving high accuracy at any < 2 µg/m³
variability(12)
environmental conditions except under foggy days or condensation, where the data is automatically inva-
lidated by EVS Omnis. Further calibrations can be applied at a specific site to match the mass concentra-
tions. The particle size distributions are available on the EVS Omnis platform.

* See notes on page 28


www.envirosuite.com 26 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 27 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Technical specs
CO CO2 NO NO2 O3 H2S SO2 NH3 VOCs PM1 PM2 5 PM4 PM10 TSP TPC
.

Non-dispersive
Photo-ionization
Type Electro-chemical infrared Electro-chemical Electro-chemical Electro-chemical Electro-chemical Electro-chemical Electro-chemical
detector Optical particle Optical particle Optical particle Optical particle Optical particle Optical particle
(NDIR) Type
counter counter counter counter counter counter
Unit of µg/m³, ppb (A) µg/m³, ppb (A) µg/m³, ppb (A)
mg/m³, ppm µg/m³, ppb µg/m³, ppb µg/m³, ppb µg/m³, ppb mg/m³, ppm
measurement Unit of
mg/m³, ppm (B) mg/m³, ppm (B) mg/m³, ppm (B) µg/m³ µg/m³ µg/m³ (A) µg/m³ (A) µg/m³ (A) counts/cm³ (A)
measurement
0 - 12,000
Measurement 0 - 2,000 ppb (A) 0 - 3,000 ppb (A)
ppb (A) 0-5,000 ppm 0-5,000 ppb 0-5,000 ppb 0-2,000 ppb 0-10,000 ppb 0-50 ppm
range (1) Measurement 0 - 10,000
0 - 20 ppm (B) 0 - 40 ppm (B) 0 - 1,000 µg/m³ 0 - 1,500 µg/m³ (A) 0 - 1,500 µg/m³ (A) 0 - 2,500 µg/m³ (A) 0 - 3,000 µg/m³ (A)
0 - 500 ppm (B) range (1) counts/cm³ (A)
1 ppb (A) 1 ppb (A) 1 ppb (A)
Resolution (2) 1 ppm 1 ppb 1 ppb 1 ppb 1 ppb 0.01 ppm
0.01 ppm (B) 0.01 ppm (B) 0.01 ppm (B) Resolution (2) 1 µg/m³ 1 µg/m³ 1 µg/m³ (A) 1 µg/m³ 1 µg/m³ (A) 1 counts /cm³ (A)

Operating temp.
-30 to 50 ºC -20 to 50 ºC -30 to 40 ºC -30 to 40 ºC -30 to 40 ºC -30 to 50 ºC -30 to 40 ºC -10 to 50 ºC -40 to 60 ºC Operating
range (3)
-10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A) -10 to 50 ºC (A)
temp. range (3)

Operating RH
0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99 %RH 0 to 99% RH Operating
range (4)
0 to 99 %RH 0 to 99 %RH 0 to 99 %RH (A) 0 to 99 %RH 0 to 99 %RH (A) 0 to 99 %RH (A)
RH range (4)

Recommended
15 to 90 %RH 15 to 95 %RH 15 to 85 %RH 15 to 85 %RH 15 to 85 %RH 15 to 90 %RH 15 to 90 %RH 15 to 90 %RH 0 to 99% RH Recommended
RH range (4)
0 to 95 %RH(A) 0 to 95 %RH (A) 0 to 95 %RH (A) 0 to 95 %RH 0 to 95 %RH (A) 0 to 95 %RH (A)
RH range (4)

Operating life (5) > 24 months > 7 years > 24 months > 24 months > 24 months > 24 months > 24 months > 24 months 10,000 hours Operating
> 24 months > 24 months > 24 months (A) > 24 months > 24 months (A) > 24 months (A)
life (5)

Guarantee 50 ppm (A)


1,000 ppm - 20 ppm 20 ppm 20 ppm 100 ppm 100 ppm 100 ppm LOD - Limit of
range (6)
60 ppm (B) 0.5 µg/m³ (A) 0.5 µg/m³ (A) 0.5 µg/m³ (A) 1 µg/m³ (A) 1 µg/m³ (A) -
Detection (7)

LOD - Limit of 10 ppb (A)


2 ppb (A)
1 ppb (A)

- 2 ppb 2 ppb 3 ppb 3 ppb 0.1 ppm


Detection (7)
0.02 ppm (B) 0.01 ppm (B) 0.01 ppm (B) Repeatability (8) 2 µg/m³ (A) 3 µg/m³ (A) 3 µg/m³ (A) 5 µg/m³ (A) 6 µg/m³ (A) -

20 ppb (A)
4 ppb (A)
5 ppb (A)

Repeatability (8) - 4 ppb 4 ppb 4 ppb 5 ppb - Response


0.05 ppm (B) 0.01 ppm (B) 0.02 ppm (B) < 10 sec < 10 sec < 10 sec (A) < 10 sec (A) < 10 sec (A) < 10 sec (A)
Time (9)
< 30 sec (A) < 12 sec (A)
Response Time (9) < 30 sec < 30 sec < 60 sec < 70 sec < 60 sec < 60 sec < 45 sec Typical Accuracy -
< 180 sec (B)
< 10 sec (B) ±2 µg/m³ (A) ±3 µg/m³ (A) ±3 µg/m³ (A) ±4 µg/m³ (A) ±6 µg/m³ (A) -
MAE (10)

Typical Accuracy ± 80 ppb (A) ± 10 ppb (A) ± 10 ppb (A)


±30 ppm ±4 ppb ±5 ppb ±8 ppb ±15 ppb ±0.3 ppm Typical
- MAE (10)
± 0.1 ppm (B) ± 0.05 ppm (B) ± 0.1 ppm (B) > 0.9 (A) > 0.8 (A) > 0.8 (A) > 0.7 (A) > 0.7 (A) > 0.8 (A)
precision - R² (10)

Typical precision
> 0.85 - > 0.9 > 0.85 > 0.9 > 0.8 > 0.7 - > 0.99 Typical
- R² (10)
0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) 0.85 - 1.18 (A) -
Slope (10)

Typical Slope (10) 0.78 - 1.29 - 0.9 - 1.12 0.78 - 1.29 0.85 - 1.18 0.78 - 1.29 0.78 - 1.29 - 0.99 - 1.002 Typical -1.8 µg/m³ ≤ a -2 µg/m³ ≤ a ≤ -2 µg/m³ ≤ a ≤ -3 µg/m³ ≤ a ≤ -4 µg/m³ ≤ a ≤
-
Intercept (a) (10) ≤ +1.8 µg/m³ (A) +2 µg/m³ (A) +2 µg/m³ (A) +3 µg/m³ (A) +4 µg/m³ (A)
-50 ppb ≤ a -2 ppb ≤ a -9 ppb ≤ a

Typical Intercept ≤ +50 ppb (A) -2 ppb ≤ a -4 ppb ≤ a -3 ppb ≤ a ≤ +2 ppb (A) -5 ppb ≤ a ≤ +9 ppb (A) DQO - Typical
- - < 50% (A) < 50% (A) < 50% (A) < 50% (A) < 50% (A) -
(a) (10) U(exp) (11)
-0.1 ppm ≤ a ≤ +2 ppb ≤ +4 ppb ≤ +3 ppb -0.02 ppm ≤ a ≤ +5 ppb -0.08 ppm ≤ a

≤ +0.1 ppm (B) ≤ +0.02 ppm (B) ≤ +0.08 ppm (B) Typical intra-model
< 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) < 2 µg/m³ (A) -
variability (12)
DQO - Typical
< 20% - < 20% < 25% < 20% NA < 25% NA NA
U(exp) (11)

Typical intra- < 3 ppb (A) < 2 ppb (A) < 3 ppb (A)
model variability - < 1 ppb < 1 ppb < 1 ppb < 3 ppb < 0.1 ppm
(12)
< 0.05 ppm (B)
< 0.02 ppm (B)
< 0.1 ppm (B)

1. Measurement range: concentration range measured by the sensor. 8. Repeatability (measured at laboratory conditions at 20ºC and 50% RH): closeness of
the agreement between the results of successive measurements of the same measu-
2. Resolution: smallest unit of measurement that can be indicated by the sensor. re carried out under the same conditions of measurement, based on the metric from
the Technical Specification UNE CEN/TS 17660-1:2022.
3. Operating temperature range: temperature interval at which the sensor is rated to
operate safely and provide measurements. 9. Response time: time needed by the sensor to reach 90% of the final stable value.
4. Operating RH range (Recommended RH range): humidity interval at which the sensor 10. Statistical metric: statistics obtained between hourly measurements of the device
is rated to operate safely and provide measurements. and the reference instruments for 1 to 8 months field test between -10 to +30 ºC in
Recommended RH range of the sensor for continuous exposure. different countries.
5. Operating life: lifetime of the sensor at normal conditions. 11. DQO-Typical U(exp): Data Quality Objetive expressed as the Expanded Uncertainity in
the Limit Value obtained between hourly measurements of the device and the referen-
6. Guarantee range: limit covered by the guarantee. ce instruments for 1 to 8 months field test between -10 to +30ºC in different countries,
based on the metric from the European Air Quality Directive 2008/50/EC and from the
7. LOD (Limit Of Detection): measured at laboratory conditions at 20ºC and 50% RH.
Technical Specification UNE CEN/TS 17660-1:2022.
The limit of detection is the minimum concentration that can be detected as signi-
ficantly different at zero gas concentration, based on the metric from the Technical 12. Typical intra-model variability: calculated as the standard deviation of the three sen-
Specification UNE CEN/TS 17660-1:2022. sor means in 1 to 8 months field test between -10 to +30ºC in different countries.

www.envirosuite.com 28 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 29 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Power packs Installation process
Air Quality Monitor 5S and 2S models are equipped with a rechargeable lithium Easy & Fast
battery which prevents the equipment from shutting down due to a power cut.
In this way, they can continue working for long periods of time until the power The installation of the Air Quality Monitor 5S and 2S models is quick and easy, and the device can start to
is restored. operate in less than 20 min.
First of all, it's needed to fix the metal support on a mast or a wall. After it, the device can be held on its
support.
Once the device is mounted in its final position, turn it on and check the confirmation on the display. If you
need to replace a cartridge, just release the metal grid, unplug the cartridge and plug the new one.
Solar packs
The 6.3-volt high-efficiency monocrystalline solar panel is robust, waterproof
(IP67) and has been designed for prolonged outdoor use in any environ-
ment. The photovoltaic panel makes the device totally autonomous from the Air Quality Monitor 5S
power grid, allowing the installation anywhere without civil works or in remote
locations.
Installation Cartridge replacement

1 2 3 4
RELEASE THE
METAL GRID
K-PW-SP12W-9C-02
DEVICE SOLAR PANEL BATTERY AVG. DURATION
K-PW-SP6W-9C-02
Air Quality Monitor 5S 12 W 93 Wh (9 cell) 9 - 30 days
K-PW-SP12W-7C-01
Air Quality Monitor 2S 6W 72 Wh (7 cell) 9 - 20 days
K-PW-SP6W-7C-01

The table above shows the minimum and maximum battery life (without solar radiation) for different device configurations.

NEW
CARTRIDGE

Outdoor charger packs


An outdoor charger must be used when the Air Quality Monitor is going to be Air Quality Monitor 2S
installed outdoors. It is small (222 x 300 x 200 mm), lightweight (220 g),
waterproof (IP67) and has been designed for prolonged outdoor use in any
environment. Input voltage 100-240V AC 50-60 Hz, Output voltage 12V DC (AC Installation Cartridge replacement
cable not included).
1 2 3 4
K-PW-12VIP65-1C-01 RELEASE THE
METAL GRID
BATTERY
DEVICE K-PW-12VIP65-9C-01
93 Wh (9 cell) 72 Wh (7 cell) 10 Wh (1 cell)
K-PW-12VIP65-7C-01

Air Quality Monitor 5S 3 - 30 days - 8 - 70 hours


Air Quality Monitor 2S - 4 - 20 days 14 - 70 hours
NEW
CARTRIDGE
The table above shows the minimum and maximum battery duration (when is not charging).

www.envirosuite.com 30 | Product Catalogue: Air Quality Monitor 5S & 2S Models www.envirosuite.com 31 | Product Catalogue: Air Quality Monitor 5S & 2S Models
Envirosuite (ASX:EVS) is a global leader in environmental intelligence,
using proprietary technology and real-time localised data to help
industries and communities thrive.

We believe that environmental intelligence has the power to


transform your operations and help your site reach its full potential.

Through a unique combination of science and technology, Envirosuite


delivers flexible solutions to address challenges of air and water
quality, noise, and vibration, making the world a better place through
improved environmental performance.

Harness the power of environmental intelligence.

Global, yet local

Melbourne, Belo Horizonte, Montréal, Las Condes,


Australia Brazil Canada Chile

Bogotá D. C., Søborg, Madrid, Folsom,


Colombia Denmark Spain USA

www.envirosuite.com

You might also like