You are on page 1of 54

om

Westi nghouse Electric Corporation t log


Ca a
Measure men s t and Con trol Dv i
i si on 42-100C
Raleigh, Nor th Carolina,U.S.A. 27 611-9533
Page 1

.c
05 Switchboard
t ber 1,198 8
Oc o
Supersedes Ca a t log 42- 100,Pages 40- 52,

Watthour and
da et d May,1979
i
Ma led t : E,D C/ 42-00 4
o

Mechanical

ls

Demand Meters
.

ua
Selection Guide.................. ........ ...... ................ 2 Style Number Definitions:
Application Guide and Catalog Index................. .......... . 3 A. Catalog - No Special Accessories, Op tions,or Fea u t res and
Style Number Format and Coding.. ........................... 4,5 "Listed" in a publ shed
i ca talog.
Definitions and Ordering Instructions............................ 6 B . Standard -No SpecialAccessories, Op itons, or Fea u t res bu t
"Not Listed" n i a published ca at log.

an
Non-Demand Registers...................... ................... 7 C. Engineered-Wi ht one or more Special Accessor es, i Op itons,or
Switchboard Watthour Meters t res.
Fea u
Clock-Dial and Dru m- Cyclo me e t r Regis ters
1-Phase 3-Wire ............................ .. (D5B- F)......... 8 How to Use This Catalog.
1-Phase 2-Wire .. ......... ....... ....... ..... (D5B- F)........ 10 i answers to Six Basic Questionslis e
A. Ob ta n t d on page 2.
B. Use Application Guide and Catalog Indexon page 3 o t r­
t de e

tM
3-Phase 3-Wire or Ne w t ork................... (D5B-2 F)....... 12
3-Phase 4-Wire Del at ............ ............ (D5B-7 F)....... 1 4 mine required me e t log .
t r type and i ts loca tion in ca a
3-Phase 4-Wire Wye 2 t tor) ............... (D5B- 8 F). ...... 1 6
( - S a
3-Phase 4-Wire Wye (3- S a t ot r) ............... (D5B-3 F)....... 1 8 How to Enter Order

Mechanical Demand Registers........... ...................... 20 A. For Catalog Style -


ar
Switchboard Demand Meters 1 . De e i fro m Price List 42-020.
t r mine Lis tPr ce
Mark aI Regis etr 2. Selec tproper cus o t mer discoun tfro m discoun tschedule and
1-Phase 3-Wire .............................. (D5B- F M).. .... 21 calcula e i
t ne tpr ce.
1-Phase 2-Wire ..................... ......... (D 5B- F M)...... 22 3. En et r order per ins rt uc tions on page 6.
3-Phase 3-Wire or Ne twork................... (D5B-2 F M). .... 23
lP

3-Phase 4-Wire Del at ...................... .. (D5B-7 F M)..... 2 4 B. For Standard Style


3-Phase 4-Wire Wye (2- S at ot r) ............... (D5B- 8 F M)... .. 2 5 1. Cons truc t S tyle Nu mber fro m S tyle Nu mber For ma tand Cod­
3-Phase 4-Wire Wye (3- S at tor) ............... (D5B-3 F M)..... 2 6 i
ng on pages 4 and 5.
tr
Mark lila Regis e 2. De e i fro m Price List
t r mine Lis tPr ce 42-020.
1-Phase 3-Wire .............................. (D5B- F M)...... 27 3. Selec tproper cus o t mer discoun tfro m discoun tschedule and
ca

1-Phase 2-Wire ... ..................... ...... (D 5B- F M)...... 2 8 calcula e i


t ne tpr ce.
3-Phase 3-Wire or Ne wt ork........... ........ (D5B-2 F M)..... 29 t r order per ins rtuc tions on page
4. En e 6.
3-Phase 4-Wire Del ta ........................ (D5B-7 F M) ..... 30
3-Phase 4-Wire Wye (2- S at tor) ............... (D 5B- 8 F M)..... 31 C . For Engineered Style
3-Phase 4-Wire Wye (3- S at tor ... ............. (D5B-3 F M)..... 32 1. Use 10 digi tca talogued s tyle nu mber for the me e t r desired
and cons truc ta "Similar to"s a t te men tfro m ins truc itons on
tri

Reactive Metering... . ......... .... ...................... ...... 33 page 6.


2. De et r mine Lis tPrice fro m Price List 42-020.
Totalizing Switchboard Watthour Meters 3. Selec tproper cus o t mer discoun tfro m discoun tschedule and
Clock-Dial and Dru m- Cyclo me ter Regis e t rs calcula e i
t ne tpr ce.
lec

3- Circu its 1-Phase 2-Wire ................... . (D5B-31 F)...... 3 4 4. Order on "NC"per ins rt uc tions on page 6.
2- Circui s t 3-Phase 3-Wire .................... (D 5B-32F)...... 3 6
t 1-Phase 2-Wire .................... (D5B-32 F)...... 3 6
4- Circui s t in this publica tion are l si ted in Price List
Pricesfor all produc s
2- Circui ts 3-Phase 4-Wire Wye ............... (D5B-3 8 F)...... 3 8 42-020.
i
2- C rcui t 3-Phase 4-Wire Wye ............... (D5B-33 F)... ... 40
s
3- Circui st 3-Phase 3-Wire Del a t ............... (D5B-3 4 F)...... 42 Accessoriesare l si ted in Catalog 42-1 00E.
6- Circui ts 1-Phase 2-Wire ....... ............. (D5B-3 4 F)...... 42
.E

Mechanical De mand Regis ters t er Technical Data on D5 Me e


For fur h i ters
t rs and applicable reg s
Mark a I Regis ters on To talizing Me ters ................. 4 4 ot 4 8 refer ot Technical Manual 42-1 050A.
Mark lila Regis ters on To talizing Me et rs ................ 49 to 53
For Instruction Literature refer to:
Service Connection Diagrams....... .............. 9,11,13,1 5, 17,19 IL 42-1009A Swi c tr
t hboard Wa tthour Me e
33,3 5,37,39,41,43 L t r.
t lizing Wa tthour Me e
I 42-1010A Sw itchboard To a

For Renewal Parts Datarefer to:


w

RPD 42-1001A Swi c tr


t hboard Wa tthour Me e
RPD 42-1002A Sw itchboard To a t r.
t lizing Wa tthour Me e
ww
om
Catalog
42-100C

Page 2

.c
Meter Selection Guide
Six Basic Questions Available Selections
1. Type Mountingdesired. a. Switchboard

ls
2. Type Serviceto be metered. a. 1-phase,3-wire
b. 1-phase, 2-wire
c. 3-phase,3-wire Delta
d. 3-phase,3-wire Network

ua
e. 3-phase, 4-wire Delta
f. 3-phase, 4-wire Wye 2( -stator meter)
g. 3-phase, 4-wire Wye (3-stator meter)
h. Totalizing
1)( 3- Circuits of 1-Phase 2-Wire
2
( ) 4- Circuits of 1-Phase 2-Wire

an
(3) 6- Circuits of 1-Phase 2-Wire
( 4) 2- Circuits of 3-Phase 3-Wire Delta
( 5) 3- Circuits of 3-Phase 3-Wire Delta
(6) 2- Circuits of 3-Phase 4-Wire Wye

3. Type Flexitest Caserequired. a. F T-21 1


( 0-ter minal)

tM
b. F T-31 (10-ter minal)
c. F T-32 (20-ter mina )
l
d. F T-32 2
( 6-ter minal)
------ ------ ··----------

4. Meter Test Ampsor Classrequired. Meter Meter


Test Amps Class
Note: Meter Class is the maxi mu m contin- 2.5 20 p( olyphase)
ar
uous a mperage to meter coils. 2.5 10 s( ingle-phase)
5. Frequency and Voltage 60 Hertz 50 Hertz
a. 72 volts a. 110 volts
b. 120 volts b. 220 volts
lP

c. 2 40 volts c. 3 80 volts
d. 4 80 volts
6. Type Registerdesired. a. Non-Demand r( efer to page 7)
(1) Clock-Dial - Standard
Note: for Pri mary Rated registers the Cur­ 2( ) Dru m-type - Cyclo meter
ca

rent and Voltage transfor mer ratios must


be obtained and included in the order b. Nu mber of Dials, Drums
entry. (1) 4
(2) 5
tri

c. Mechanical Demand ( Refer to page 20)


(1) Type Desired
(a) Mark a I (Pointer-type)
b
( ) Mark Ilia ( Clock-Dial type)
2
( ) Reset Interval Desired
lec

(a) 1 5 Minutes
b
( ) 30 Minutes
3
( ) Nu mber of kWh Dia sl
Accessories- Refer to Catalog 42-1 00E.
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 3

.c
Application Guide and Catalog Index

ls
ua
an
Switchboard Mounting FT-21 Case "058" Switchboard Mounting FT-32 Case "058"

. andWes
tM
For Style Nu mbers and Descriptions see Catalog Pages as ndicated
I
Type Serv ice to be Metered I tin ghouse Regist e r Types

I 1.
Meter Type
Tes t Amps
Non- demand -----r Mechani cal Demand
Co
l ck- and Mark Ia Mark i lal
D ru m- t ype

---·· --��----
Pointer C lock- dial
ar
I
---- �-+--
1-Phase 3-Wire

E D5H 2.5A
I
I 058-F, 2.5A
08 ,,,,

I Page 10
Page 21 Page27
lP

I
Page 22 Page28
D58-31 F, 2.5A �· Page34

I
Page44 Page49
1 -Phase 2-Wire (Totalizing)
D583- 2F, 2.5A �· Page36 Page45 Page50

-+Page_42_
ca

(Totali z i ng)
D58-3 4F, 2.5A ----· -1 Page 48 -rP ag e53
(Totali zin g) _ __ _ __ _ __ _ _ __
_ _ _ __
__ __

3-Phase 1 -Phase D58-2F, 2.5A --- P�_ge


_ 12 1 Page 23 Page 29

I Page48
3-Wire 3-Wire
__

D58-3 2F, 2.5A Page36 Page45 Page50


tri

(Totali zi ng)
D58-3 4F, 2.5A Page42 Page 53
(Totalizin g)
lec

3-Phase
4-Wire D58-7 F, 2.5A Page14 Page24 Page30
Delta

Ope n Delta
.E

3-Phase Neutral D58-8F, 2.5A Page16 Page25 Page31


4-Wire Wye
(2-Stator Meter) D58-38F, 2.5A Page38 Page46 Page51
(Totalizing)
w
ww

3-Phase Neutral D58-3 F, 2.5A Page18 Page 26 Page32


4-Wire Wye
(3-Stator Meter) D58-33F, 2.5A Page40 Page 47 Page 52
(Total izin g)

October, 1 988
om
C at alog
42-100C

P age 4

.c
Smart Style Numbers
This meter numbering system uses the first 6fields to cl assify meters into f amily groups
b ased on predomin ant simil arities.

Fields 1 through 4 define the meter ch assis and cover.


# 1 defines the Seriesof meter plus the Covertype.

ls
#2 defines type of Serviceon which the meter is to be applied.
#3 defines the type Mounting and meter Test Amperes.
#4 defines the Frequency and Voltageto be metered.

ua
Fields 5 and 6define the princip al register desired .

The l ast 4 fields sub-div de


i these f amilies b ased on their differences.
#7 "A"denotes a c at alogued or st and ard configur ation.
#8 Uses anumeric al code to specify the number of kWH digits desired on the register.

an
#9"A"denotes a c at alogued or st and ard configur ation.
# 10 "A" denotes a c at alogued or st and ard configur ation with a register multiplier other
th an 10.
"1"denotes a c at alogued or st and ard configur ation with aregister multiplier of 10.
"X,Y,or Z"denotes a specific register r atio for Univers al mech anic al dem and
registers.

tM
ar
lP

Catalog and Standard Style Numbers for 05 Single-Phase and Polyphase Switchboard Watthour and Mechanical Demand Meter:.
Field # 1 Field #2 Field #3
Series and Cover Type Service Mounting and Test Amps
ca

E = D5 with Single - Phase Switchboard (2. 5 Amps)


Pl astic cover Non- Tot alizing
A 1-Ph ase 2-wire
F F T-2 1 C ase
c 1- Ph ase 3-wire H FT-3 1 C ase
tri

K FT-32 C ase
Polyphase
Tot alizing
2 = 3-Ph ase 3-wire Delt a 2
( - St ator) -
( 2)
L 3- Cir 1-Ph ase 2-Wire
lec

3 = 3-Ph ase 4-wire Wye 3


( - St ator) (-3) D5B-3 1 F 3- St ator

4 = 3-Ph ase 4-wire Wye 3 ( - St ator) -


( 3) M = 2- Cir 3-Ph ase 3-Wire
(s
I ol ated Potenti al Le ads) or 4- Cir 1-Ph ase 2-Wire
D 5B-32 F 4- St ator
7 = 3-Ph ase 4-w re
i Delt a 2
( - St ator) -
( 7)
P 2- Cir 3-Ph ase 4-Wire Wye
.E

8 = 3-Ph ase 4-wire Wye 2


( - St ator) -
( 8) D5B-3 8 F 4- St ator

I'
j___
' R = 2- Cir 3-Ph ase 4-Wire Wye
D5B-33 F 6- St ator

T = 3- C ri 3-Ph ase 3-Wire Delt a


or 6- Cir 1-Ph ase 2-Wire
w

D5B-3 4 F 6- St ator
ww

October, 1 988
om
8
Catalog
42-100C

Page 5

.c
Smart Style Numbers

Examples:

Catalog Number

� E 2 F C LA 4 A A Standard Style Number

II
E3 F

I
1 3 3 A 5A A

ls
E = D5with Plastic Cover E � 05w;th ,,,.;, Co•oc
2 = 3-Phase 3- Wire ----- ·
3 = 3-Phase 4- Wire Wye, 3 Stator
F = Switchboard-type,2.5Amps F = Switchboard-type, 2.5Amps
1 = 60 Hertz, 120 volts -------' 1 = 60 Hertz, 120 volts -------'

ua
C = Clock- Dial Register--------' 3 = Mark lila Register --------'
L= Standard Register-------' 3 = 30 Minute Interval--------'
A= Catalog Number --------' A = Standard Style --------_.J
4 = 4 Digit k WH Register-------' 5 = 5 Digit k WH Register-------'
A= Catalog Number -------' A = Standard Style --------'
A= Catalog Number --------' A = Standard Style -------'

an
tM
ar
lP


Field #4 Fields #5 and #6 Field #7 Field #8 Field #9 Field # 1 0
Frequency Major Register Style Category Number of
g� e-
and Volta_ _.. ---------------+--------- c--- k_W_ H _ D · gits
ca

1
____
-+
60 Hertz Non-Demand A= Catalog or 4 = 4 Digit A = Catalog A = Catalog or
1 = 120V Standard Style 5 = 5 Digit or Standard Style
·

2 = 2 40V CL= Standard Clock Standard


4 = 4 80V CY= Drum- Cyclometer Note: Style Register Multiplier
7 = 72V Any code other of 10
tri

Standard Mark Demand than "A"in field D= Detent


50 Hertz #5= Type #6= Interval #7 is an engi­ Universal Mark
A= 1 10V neered styleand Demand
C = 220V 1 = Mark aI 1 = 15 Min coding shown for Registers Only
X = Register
lec

D = 3 80V 3 = Mark lila 3 = 30 Min Fields # 8, 9, & 10


will not apply Ratio of 4 1 2/3
Y = Register
Ratio of 83 1/3
Z= Register
Ratio of 1662/3
.E

Universal Mark Demand


#5= Type #6= Interval

6= Mark Ia 1= 15 Min
8= Mark Ilia 3 = 30 Min

fI used with an "A" in Field 7


must specify"X ,Y,or Z" in Field
w

10.
ww

October, 1988
om
Cata og
l
42-100C

Page 6

.c
Definitions and Ordering Instructions
I
Ta
Definitions Ordering Instructions for Catalogued and Ordering Instructions for meters with
Standard Styles ______ Primary Rated Registers .

I.
A. A Cataloguedor Standard meter Order Entry on Warehouse or 091. rder Entry on NC*
configuration consists of:

ls
I
I
1. Bas ci meter chassis and cover as When ordering, Specify: When ordering, Specify:

I.
defined by the f rst
i 4 d gits
i of style 1. Complete style number.
number format on page 4. 2. Type of meter ordered. ! A. " Similar to style" statement.

L -�

ua
2. A register as defined by the 5th,6th &
8th d gits
i of style number format on , Examples: E2 F 1 CLA 4AA D5B-2 F B. Ten d git
i style number. Use catalogued
pages 4 and 5. ______ E2 F161A 4AY D5B-2 F M style number for basic meter
conf guration
i desired.

I
I

B. A Special Engineered conf guration i

I
consists of: Ordering Instructions for meters with C. Meter to have Primary Ratedreg ster.
i

an
Special Features

I
1. A bas ci meter chassis,cover and
.
D. Current and Voltage transformer ratios

I
register as defined by the first 6digits

�·
of the style number format on page 4. must be included n i the order entry
2. One or more of the follow ng: i Order En ry on NC information.

·
a. Accessory, Option or Special

I
Feature listed in Catalog 42- 100 E When ordering, Specify: The Current transformer ratio must be

tM
or Price L sti 42-020 Table 9. 1. Complete style number. specif ed
i as "x"/ 5 amps.

I I
b. Reg ster
i Ratio other than those 2. Complete meter description
l sted
i for catalogued styles. consisting of: The Voltage transformer ratio must be
c. Primary Rated Register for use on a. Meter Type specified as "x"/ 1 volts.

I I
transformer rated meters.
·
b. Test Amps
c. Hertz Example:
ar
For Primary Rated registers the Current and d. Voltage

I
Voltage transformer ratios must be obtained e. Type Register and #of Digits Similar to E2 F1 CLA 4AA D5B-2 F meter

f
and ncluded
i in the order entry. f. If Mechanical Demand Register except to have primary rated register
( 1) Demand Interval used with instrument transformers rated:


Notes: 2
( ) Full Scale kW C T ratio = 100/ 5 amps
lP

g. Register Rat o i ratio = 70/ 1 volts


_
A. Registers h. Register Multiplier ___ _ _ _
_______
-- __
1. The register ratio for the chassis 3. A listing of Accessories, Options,or
specified by the first 4 digits must be Special Features des red,
i such as
the same as listed for catalogued
ca

detents,pulse initiators,or isolated


styles. potential terminals for react ve
i
2. For Mark Ia mechan cal i demand meter ng.i

I
registers the catalogued classes are:
a. Transformer-rated meters: Example: *Notes:
Class 2/6 (single-phase) When the order is processed at NC the

I
tri

Class 4/ 8 (polyphase) 1. Non-demand meterwith pulse initiator Engineering Dept will assign an Engineered
Style Numberwhich will be permanently

I
B. Voltage Indicator LEOS Sim lar
i to E2 F1 CLA 4AA D5B-2 F,2.5A, recorded for that specific meter
( Potent al
i Indicating Lights) 60 Hz, 120V, Clock 4-Dial,except with configurat on.
i
Switchboard meters are equ pped
i with CDI-228pulse init ator,
i Mp = 1/2,and
lec

L ED type voltage indicator lights as mechanical detent to prevent reverse Sh pment


i to the user will be made using
standard. registration. 1
the Eng neered
i Style Number.
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 7

.c
Non-Demand Registers for Single - Phase and Polyphase Switchboard Watthour Meters
Primary-Ratedregisters are available in both clock-dial and drum-cyclometer types.
Contact your Westinghouse representative for available ratios. These registers are available
in the following configurations for registering kWHr, O Hr,and kVA R Hr readings.

ls
Clock-Dial Type

®
Westinghouse

ua
KILOWATTHOURS

5-Dial 1 5-Dial 10

an
X X

® C\iC:I
Westinghouse l__j Westinghouse

(!)(!)(!)(!)
KILOWATTHOURS

4-0ial x 1
tM 4-Dial x 10
KILOWATTHOURS

4-Dial x Tr
ar
Drum-Cyclometer Type
lP

Westinghouse
_a
ca

---�--�-�

9 8 4 1 8 Rr 33113

0 - KILOWATTHOURS-
02

5-Drum x 1 5-Drum x 1
(with Lazy "0")
tri
lec

----- -

9 8 4
---� �-
1
0 - KILOWATTHOU

4-Drum x 1 4-Drum x 10 4-Drum x Tr


.E
w
ww

October, 1988
om
Catalog
42-100C

Page 8

058-F Single-Phase Switchboard Watthour Meters

.c
1-Stator for 1-Phase 3-Wire Product Code 4811
1-Phase

E
Service Input
Schematics 3 - Wire

ls
- ''
Effective CT Ratio xeffective VT Ratio


Tr
______
I
=

Class ' T: es t Re g is t er Re gis t er


Type Vol t s
__ _____ __________ _

I
_ _

;I Amps
Style Numbers

1 -
Kh
- Mul t i- Ra it o
',

#Terminals
1 _

Stand ard Clock D ial D rum -Type Cy c lome t e r


Case Si z e -� -� � �� p lier*�-I

I

ua
1 I
4 - Dial 5 - Dial 5 - Drum
'
_

--:-- --t-

LL I
_ _ __ _ _ - _ _ _ _ _ _ _ _ _ _ _____c_ ____
,

0 5 8 -F Sw itch board T yp e ' ___

. -�
I 166 2/3 E CF2 CLA4AA E CF2 CLA5AA E CF2 CYA5AA
Transformer - Rated 10 , 2.5 I 240 0.6 Tr
I
__l_
6-Terminal
FT -21 Case '
__ ___[_______ L'i
* For Primary Rated re g is ters see Ordering Instructions on p a g e 6, _
_ _____ L__ ____ _ _

an
__l_
Case Dimensions: For reference only ( Inches)

Shipping Dimensions ( Inches)


Type
D5 B--F-
!
ICar t on
Quant i t y �L
��-- -
L_
-
Wi� ----,--- Hei g ht
__j__ ,-7 -=L_11 112 _I 12 =
_
tM ,
.J
ar
L1 ____ __
lP
ca

Panel Cutout Dimensions (Front View ) : Term inal and Mounting Hardware:
For reference only ( Inches) For reference only ( Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting
. ·-·
tri

SpacerforThin Panel (Upto1i)


.190-32
Screw 1�-18 Screw
(For Thick
lec

Panel Use
�-18 Stud)

.190-32
4�4�
Screw
(For Thick
�2 j__..__---+-....J
.E

Panel Use

__t___-r----e-
.190-32
Stud)
�Diameter ( 4 ) Hol es
2lDiameter
!;!..--- Panel
w

�Radius
ww

October, 1988
om
Catalog
42-100C

Page 9

058-F Single-Phase Switchboard Watthour Meters


Service Connection Diagrams for 1-Phase 3-Wire Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-F
All diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
8A 6C r!1
(z) 0 (.!<_) D E MA N D M O T O R L EA D S
DE�AND CONTACTS O R I NT E R NAL P OWER
S U P PLYW H E N U S E D

an
... C I R C U I T CL O SI NG
D EV I C E

t C U R RE N T T ES T JA CK
tM EX T E R NAL J U M P E R S
5 3
-
ar
lP

...
COMMON z

0
ca

voltage trans former when used should be connected as shown below

LJI
tri


lec

----
-- C� � ON
----� ��� -----------
-�
-- -- ----

0
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 10

058-F Single-Phase Switchboard Watthour Meters

.c
1-Stator for 1-Phase 2-Wire Product Code 4811
Service Input 1-Phase
Schematics 2-Wire

ls
Tr = Effecti ve C T Ratio x V T Ratio
I I
I
Type Class Test Volts Kh Register Register Style Numbers
#Terminals Amps
I Multi- Ratio

ua
Standard Clock Dial Drum-Type Cyclometer
Case Size plier*
4-Dial 5-Dial 4-Drum 5-Drum

I
058-F Switchboard Type
Transformer-Rated 10 2.5 120 0.3 I Tr 333 1/3 EAF1CLA4AA EAF1CLA5AA EAF1CYA4AA EAF1CYA5AA
4-Terminal 10 2.5 240 0.6 Tr 166 2/3 EAF2CLA4AA EAF2CLA5AA EAF2CYA4AA EAF2CYA5AA
FT-21 Case

an
• For Primary Rated registers see Ordering lnstructtons on page 6.

Shipping Weights (Approximate in Pounds) Case Dimensions: For re ference only ( Inches)
Carton Domestic Export
Type
Front View
I I I
Quantity

tM
Net Shipping Net Legal Gross

D58-F 1 12
I 14 12 I 14 I 24

Shipping Dimensions ( n
I ches)
Type Carton Length Width Height
Quantity
ar
D58-F 1 17 11 1/2 12
lP
ca

Panel Cutout Dimensions (Front View): Terminal and Mounting Hardware:


For reference only ( Inches) For reference only ( Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting

Spacer forThin Panel (Upto1% )


tri

1%-18 Screw
.190-32
Screw
lec

''----(ForThick
fs-18 Stud)
Panel Use

40'4�
.190-32
Screw
32
j_
(ForThick
.E

Panel Use

_c_-r- '-
· . ----e
---'
--+-
k Diameter 4) Holes
(
.190-32
Stud)

�Diameter
Lol-.--- Panel
w

�Radius
ww

October, 1988
om
Catalog
42-100C

Page 1 1

058-F Single-Phase Switchboard Watthour Meters

.c
Service Connection Diagrams for 1-Phase 2-Wire Service
Watthour and Demand Meters
Switchboard-Type 058-F
Al l diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
.-----
BA 6C 78

\J> 0> (K)


DEJ.4:�o- _c�;:�-�� _ �
D E MA ND M O T O R L EADS
O R I N T E R NAL P OW E R
SU P PLYWH E N U S ED

'�l
an
I I


I I

L ___ "'
3
... C I R CUI T CL O S I NG

1+
4 2
DEV I C E

� CU R R E N T T E S T JA CK

tM -�
2
ar
lP

r--. A/
-
0 "'
.. vv z
0 -
.J .J
'
ca

voltage transformer when used should be connected as shown below


tri

�I
lec

e
0 "'
.. z
0
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 12

D5B-2F Polyphase Switchboard Watthour Meters

.c
2-Stator for 3-Phase 3-Wire or Network Service Product Code 48 24

E
Service Input 3-Phase 1-Phase Network
Schematics 3-Wire 3-Wire 3-Wire

ls
Tr Effective C T Ratio x effective V T Ratio
g t;r -�

ua
Type Class Test Volts
;
Kh
I Re is Register Style Numbers
#Terminals Amps Multi- Ratio
Standard Clock Dial Drum-Type Cyclometer
Case Size plier•
i 4-Dial 5-Dial 4-Drum 5-Drum
05B-2F Switchboard Type
I
20 2.5 72 0.72 Tr 138 8/9 E2F7CLA4AA E2F7CLA5AA E2F7CYA4AA E2F7CYA5AA

I
Transformer-Rated 20 I 2.5 120 1.2 Tr 83 1/3 E2F1CLA4AA E2F1CLA5AA E2F1CYA4AA E2F1CYA5AA

an
10-Terminal 20 2.5 240 2.4 Tr 41 2/3 E2F2CLA4AA E2F2CLA5AA E2F2CYA4AA E2F2CYA5AA
FT-21 Case 20 I 2.5 480 4.8 Tr 20 5/6 E2F4CLA4AA E2F4CLA5AA E2F4CYA4AA E2F4CYA5AA

• For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights (Approximate in Pounds) Case Dimensions: For reference only ( Inches)

tM
Type Carton Domestic Export
Front View Side View
Quantity
Net I Shipping Net I Legal I Gross

D5B-2F 1 12
I 14 12 _L__1_4_ ___ I 24

Shipping Dimensions ( Inches)


ar
Type Carton Length Width Height

+---- --''--- ·-f.... --·-------··----


Quantity
----
D5B-2F 1 17 11 1/2 12
_____...L._____
.._ ___j______.L.___________ -----
lP
ca

Panel Cutout Dimensions (Front View) : Terminal and Mounting Hardware:


For reference only ( Inches) For reference only ( Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting
tri

Spacer for Thin Panel (Up to 1� )


190 3 2
-
lec

Screw 1�-18 Screw


(For ThiCk
Panel Use
1�-18 Stud )

.1 90-32
40'4�
.E

Screw
_C ,
(For Thick
_ f---
0---'
32L.._,_ Panel Use
. 190-32
Stud )
�Diameter (4) Holes
�Diameter
w

lA..---Panei

�Radius
ww

October, 1988
om
Catalog
42-100C

Page 13

D5B-2F Polyphase Switchboard Watthour Meters


Service Connection Diagrams for 3-Phase 3-Wire or Network Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-2F
All diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
U 6-
-C 78- -l
I (Z) �) @
- --

{'(
DE MA ND M O T O R L EADS
I DEMANO CQ!!T�L
,_

O R I N T E R NAL P OWE R
I �-·-·-�
I
�-� S U P PLYWH E N U S ED

an
I I 1
')1 I
l
I I
l
I I
·-

l
C I R C U I T CL O S I NG
DEV I C E

C U R R E N T T E S T JA CK
I
tM I

I
I
I
ar
J
EX T E R NAL J U M P E R S
L 10- 4, 9-3
lP

0
...
0
_J
"T
ca

voltage transformer when used should be connected as shown below


tri

! �...----.--1'
lec

�=============:
r:;;q; ===�=·=�=-===·:==============�
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 1 4

D5B-7F Polyphase Switchboard Watthour Meters

.c
2-Stator for 3-Phase 4-Wire Delta Service Product Code 48 2 4
Service Input 3-Phase
Schematics 4-Wire
Delta

ls
Tr = Effective C T ratio x e f fective V T ratio
Type Class Test Volts Kh Register Register Style Numbers
#Terminals Amps Multi- Ratio

ua
Standard Clock Dial Drum-Type Cyclometer
Case Size plier*
4-Dial 5-Dial 4-Drum 5-Drum

D5B-7F Switchboard Type


Transformer-Rated 20 2.5 240 2.4 Tr 41 2/3 E7F2CLA4AA E7F2CLA5AA E7F2CYA4AA E7F2CYA5AA
10-Terminal 20 2.5 480 4.8 Tr 20 5/6 E7F4CLA4AA E7F4CLA5AA E7F4CYA4AA E7F4CYA5AA
FT-21 Case

an
* For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights A
( pproximate in Pounds) Case Dimensions: For refe e
r nce only (Inches)
Type Carton Domestic Export
Front View Side View
Quantity
Net
I Net
I I

tM
Shipping Legal Gross

D58-7F 1 12 I 14 12 I 14
I 24

Shipping Dimensions (Inches)


Type Carton Length Width Height
Quantity
ar
D5B-7F 1 17 11 1/2 12
lP
ca

Panel Cutout Dimensions ( Front View ) : Terminal and Mounting Hardware:


Fo r e
r fe e
r nce only (Inches) For reference only (Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting
tri

Spacer for Thin Panel (Up to1�)


.190-32
Screw 1�-l8 Screw
(For Thick
lec

Panel Use
fs-18 Stud)

4�4�
.190-32
Screw
32
J.......! (For Thick

1__=_ ,"-
· . ----e-
f---
- -..1
Panel Use
.E

.190-32

�Diameter ( 4) Holes Stud )

�Diameter
£..l-or--- Panel
w

�Radius
ww

October, 1988
om
Catalog
42-100C

Page 1 5

D5B-7F Polyphase Switchboard Watthour Meters


Service Connection Diagrams for 3-Phase 4-Wire Delta Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-7F
All diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
I � � re I
r!; lV �) y D E MAND MO TO R L EADS
I __ ����N� �ON�Ac:!.S _..,, , �I O R IN T E RNAL POWE R
I ••• !
I
S U P PLyW H EN U S ED

I �: I

an
'-------.,
.-t----+----
I
I

iI
I _jl
I

I
tM
•- C I R C U I T CLO SING
D EV I C E

I I
1 C U R R EN T T E S T JA CK I I EX T E RNAL J U M P E R S
L
ar
9-7- 5
lP
ca

voltage trans former when used should be connected as shown below


tri


:-----------+--���r:--: ·---- -·----���lU_TR�AL� -�� 3 �
lec

��
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 16

058-SF Polyphase Switchboard Watthour Meters

.c
2-Stator for 3-Phase 4-Wire Wye Service Product Code 48 2 4
Service Input 3-Phase Notes:
4 - Wire 72 vo lt meters are for use o n69.2/120 V c ircuits.
Wye
Schematics
120 vo lt meters are for use o n 120/208 V circuits.
240 vo lt meters are for use o n 265/460 or 277/480 V circ uits.

ls
Tr

I
Effective C T ratio x effective V T ratio

I
Type Class Test Vo lt s I Kh I Reg1ster Reg1ster
---
;
Style Numbers
#Terminals Amps Multi- Ratio Standar d Clock D ial
-- -- --
Drum -Type Cyclometer
Case S i ze

ua
tf
4 - Dial 5 - D ial 4 - Drum 5 - D rum
20 2.5 72 1.08 92 16127 E8F7 CLA4AA E8F7 CLA5AA E8F7 CYA4AA E8F7 CYA5AA
--- ----- --

I
058-BF Switchboard Type

I J
Transformer - Rated 20 2.5 120 1.8 55 5/9 E8F1 CLA4AA E8F1 CLA5AA E8F1 CYA4AA E8F1 CYA5AA
10-Terminal 20 2.5 240 3.6 27 719 E8F2 CLA4AA E8F2 CLA5AA E8F2 CYA4AA E8F2 CYA5AA
FT -21 Case
* For Primary Rated registers see Ordering Instructions o n page 6.

an
Shipping Weights (Approximate in Pounds) Case Dimensions: For reference only ( Inches)
Type Carton _ Domestic __ Export _ _ _ _ __
-I - �t� -_Le gaI , 1 --G-ro ss
Front View Side View
_ _t_
ou_ an it _Y _ _l_I-_-�N�et- -_ , I-Sh- -ipp in- g -�-Ne
_ i -
I 12 -r 14
_
12 I 14 I 24
_______ _

tM
D5B -8F 1

I
Shipping Dimensions ( Inches)
Type Carto n Len gth Width Hei ght
Quantity
D5B-8F 17 11 1/2 I 12
ar
1
------ ·--- -
lP
ca

Panel Cutout Dimensions (Front View) : Terminal and Mounting Hardware:


For reference only (Inches) For reference only ( Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting

Spacer for Thin Panel (Up to 1tl


tri

1�-18 Screw
.190-32
Screw
(For Thick
lec

Panel Use
1�-18 Stud)

4�4�
.190-32
Screw

_
(For Th1ck
_1__
32
Panel Use
C_ r- '--- - -----
1---
---1 -' ---e-
.E

.190-32

� D1ameter (4) Holes


Stud)

�Diameter
[..}..---Panel
w

�Radius
ww

October, 1988
om
Catalog
42-100C

Page 17

D5B-8F Polyphase Switchboard Watthour Meters


Service Connection Diagrams for 3-Phase 4-Wire Wye Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-8F
All diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
I SA -6C 78 I
'.]; (!) y
- - - D E MA ND M O T O R L EADS
C!i
_!!III�IC>_�A�S _
O R I N T E R NAL P OW E R
I r ___ , • •

�III
SU P PLYWH E N U S ED

I :

an
,J N O T E D E MA ND M O T O R
< I
' v •

L EADS C O N N E C T ED
A C R O S S 1-3 F O R 72
I
<,
I V OL T S E RV I C E
I
I I

tM
•- C I R CU I T CL O S I NG r'
DEV I C E

l CU R R E N T T E S T JA CK
ar
EX T E R NAL JU M P E R S
L _j 9-7- 5, 10-2
lP
ca

voltage trans former when used should be connected as shown below


tri

�- J
t'
lec

�-
l ' "'
2 z
0 '-
0 ..J
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 1 8

05B-3F Polyphase Switchboard Watthour Meters

.c
3-Stator for 3-Phase 4-Wire Wye Service Product Code 48 24
Service Input 3-Phase Notes:
Schematic 4-Wire 72 volt meters are for use on 69.2/120V circuits.
Wye 120 volt meters are for use on 120/208V circuits.
240 volt meters are for use on 265/460 of 277/480V circuits.

ls
I
Tr = Effective C T ratio x e ff ective V T ratio
Type Class Test Volts Kh Register Register Style Numbers

I
#Terminals Amps Multi- Ratio

ua
Standard Clock Dial Drum-Type Cyclometer

I
I
Case Size plier*

I
4-Dial 5-Dial 4-Drum 5-Drum
�-

D5B-3F Switchboard Type

I
20 2.5 72 1.08 Tr 92 16/27 E3F7CLA4AA E3F7CLA5AA E3F7CYA4AA E3F7CYA5AA
Transformer-Rated 20 2.5 120 1.8 Tr 55 5/9 E3F1CLA4AA E3F1CLA5AA E3F1CYA4AA E3F1CYA5AA

I
I
1 0-Terminal 20 2.5 240 3.6 Tr 27 7/9 E3F2CLA4AA E3F2CLA5AA E3F2CYA4AA E3F2CYA5AA
FT-21 Case
I I I

an
* For Primary Rated registers see Ordering Instructions on page 6.

I
Shipping Weights (Approximate in Pounds) Case Dimensions: For reference only ( Inches)
Type Carton Domestic Export Front View Side View
Quantity
I I !

tM
Net Shipping Net Legal Gross

D5B-3F
I 1 12
I 14 12
I 14
I 24

Shipping Dimensions ( Inches)


Type Carton Length Width Height
Quantity
ar
D5B-3F 1 17 11 1/2 12
lP
ca

Panel Cutout Dimensions (Front View) : Terminal and Mounting Hardware:


For reference only ( Inches) For re ference only ( Inches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting
tri

Spacer forThin Panel (Upto 1� )


.190-32
Screw 1%-18 Screw
(For Thick
lec

Panel Use
1�- 18 Stud)

.190-32

4�4�
Screw

_C_r...__ 1---
____, 0-'
(For Thick
_L
32
Panel Use
.E

.190-32

kDiameter ( 4) Holes
Stud)

�Diameter
[,!-��- Panel
w

iDiameter Hole �RadiUS


ww

October, 1988
om
Catalog
42-100C

Page 19

D5B-3F Polyphase Switchboard Watthour Meters


Service Connection Diagrams for 3-Phase 4-Wire Wye Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-3F
All diagrams are rear view

Current Closing Switches are Operated by Test Switch Handle and Also by Removal of Chassis

ls
ua
6C 78
Cz) (y'\
8A
(K""'
-Cl: .. AN'i) CON'fi.C TS
D E MA ND MOTO R LEADS
O R I N T E R NAL POWE R
,------ -- --"'.,\."..,•,- - --- - -
SU P PLYWH E N U S ED

an
NO T E D E MA ND MO TO R
L EADS CO N N E C T ED
A C RO S S 2-3 FO R 72V.
S E RVI C E

._ .. C I R CU I T CLO S I NG
D EV I C E

tM EXT E R NAL JU M P E R S


ar
9-7- 5
CU R R E N T T E S T JA CK
lP

•----2---+�����-+_.-- w
o ------�-4����--_.- 3 -
z

R�A�L----��- O�
�N�E�UT�
ca

voltage transformer when used should be connected as shown below


tri

£t:;:J�I'
lec

OPE
'""

zz
0

"'

0 NEUTRAL 3 �
0
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 20

.c
Single-Phase and Polyphase Switchboard Watthour Mechanical Demand Registers
The "Watthour Mechanical Demand Meters"are identical to the watthour meters described on pages 8 through 19except for the deletion
of the non-demand register and the addition of the demand register and its necessary components; (two motor leads and demand cover
t )·
with rese_ �·
_ c__�����

ls
Mechanical Demand Registers for use on D-line Watthour Meters
Mark Ia Dual Range Indicating Demand The Mark aI register gives a combination of kilowatthour consumption and the maximum
kilowatt demand averaged over a definite time interval by means of a pointer moved over a
graduated demand scale.

ua
The Mark Ia is a dual class,dual range register and the class change is made by reversing
the scale plate which mechanically changes the gear ratios to correspond with the scale in
use.
The Mark Ia is available with 5 "in-line" kilowatthour dials. For 4-dial applications the 5th
dial is covered with a black blanking disc.

an
References: Technical Manual 42-1 050A
Renewal Parts Data RPD 42-302.A2

See Pages 21-26for Catalog Meter Styles


Mark lila Clock Dial Demand The Mark lila register gives a combination of kilowatthour consumption and the maximum

tM
kilowatt demand averaged over a definite time interval by means of 3-clock type dials at the
bottom of the dial plate. The Mark lila is available with 5 "in-line"kilowatthour dials. For
4-dial applications the 5th dial is covered with a black blanking disc.

References: Technical Manual 42-1 050A


Renewal Parts Data RPD 42-303.A 1
ar
See Pages 27-32 for Catalog Meter Styles
lP
ca
tri
lec
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 21

058-FM Single-Phase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 3 3
1 -Stator for 1 -Phase 3-Wire

=
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Registers Class 2/6, Standard F SKW 333V3and 6662/3o f test kVA

See page 9 for Service Con nections

ls
- _ _ ____'i -

1
Tr = E f fective C T Ratio x e f fective V T Ratio
1 - -
Kh
- - -
- -
- -
, - _ _ - - - -
- -
- -
- -
- ,
- - -
- - -
- -
- -
- -
- -
- -
, -
- -
-
Style Numbers
-
Type Class Test v o l ts Full Scale kW Register
#Terminals ' Amps and Multiplier* Ratio
, 4-Dial 30 Minute

ua
'

I
Case Size I
Interval
15 Minute
i
--------�--�--- -- -----r--
Interval

05B-FM Switchboard Type

I
Transformer-Rated 10 2.5 0.6 2.0/4.0 x Tr 166 2/3 ECF261A4AZ ECF263A4AZ
6-Terminal
FT-21 Case

an
* For Primary Rated registers see Ordering Instructions on page 6.

r-
Shipping Weights (Approxima
_ _t,e in Pounds) Case Dimensions: For re ference only (Inches)

� ---,
1 }- l
Type Carton Domestic Export Front View Side View

tM
Quantity
Net Shipping Net Legal Gross 6·38--- 7 21 32

D5B-FM 12 14 12 14 24
. ·-· ---·-""'---�- 3 3-16 3-3-16 119 32 61 16
I

11 -�-
Shipping Dimensions ( Inches)
i

I
,
.J
Type Carton Length Width Height
- 7· 32
ar
Quantity

D5B-FM 1 17 11112 12 10-7i32


+- -


---

-7'32


lP

For Panel Cutout Dimensions and


ca

Terminal and Mounting Hardware,


see page 8.
tri
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C

Page 22

058-FM Single-Phase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 3 3
1 -Stator for 1 -Phase 2-Wire
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Reg isters Class 2/6, Standard F SKW = 333%and 666%of test kVA

ls
See page 1 1 for Service Connections
Tr = Effective CT Ratio x effective V T Ratio
__ _ - -----
Type Class -,-1 - T- e-st ----,1-vo lts------, Kh - -----�--Full-----Scale kW -----,- ----.--Style
Register --Numbers
-
# Terminals Amps and Multiplier* Ratio 4-Dia----
l

ua
-,

I
Case Size
15 Minute 30 Minute
Interval Interval
j
DSB-FM Switchboard Type --
Transformer-Rated 10 2.5 120 1.0/2.0 x T r 333 1/3 EAF111A4AA EAF113A4AA
4-Terminal 10 2.5 240 2.0/4.0 x Tr 166 2,3 EAF261A4AZ EAF263A4AZ

an
FT__ -_ 21_ C_ _a_se
________ l__ __j
___ __ ____�___ __l____j_________L___
* For Primary Rated registers see Ordering Instructions on page 6.

Case Dimensions: For reference only ( Inches)

" �
1 }- l
Front View Side View

1'
Shipping Dimensions (lnche�)
tM 6-3/8

3-3/1 6 -+--�>----t-- 3-3/1 6 1 - 1 9/32


721/32

6-1/16

1 11 1/2
,

-
Type Carton Length Width Height

--- - _1- ---


_J
ar
Quantity
'------+----
1 - 12
0���1'\11- �_ 7 _
- -----·
_ _ ____ __
lP
ca

For Panel Cutout Dimensions and


Terminal and Mounting Hardware,
see page 10.
tri
lec
.E
w
ww

October, 1988
om
Cl
Catalog
42-100C

Page 23

D5B-2FM Polyphase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 34
2-Stator for 3-Phase 3-Wire or Network
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Registers Class 4/8, Standard F SKW = 400 and 800%of test kVA

See page 13 for Service Connections

ls
Tr = Effective C T Ratio xeffective V T Ratio

I
.t.
I
Type Class Test Volts Kh Full Scale kW Style Numbers
#Terminals Amps and Multiplier* 0
4-Dial

ua
Case Size
15 Minute 30 Minute

j.
:�:"" r--
Interval Interval

I
D5B-2FM Switchboard Type
I
20 2.5 72 0.72 1.44/2.88 x Tr ! 138 8/9 E2F711A4AA I E2 F713A4AA
Transformer-Rated 20 2.5 120 1.2 2.4 /4.8 x Tr 83 1/3 E2F161A4AY i E2F163A4AY
10-Terminal 20 2.5 240 2.4 4.8 /9.6 x Tr 41 2/3 E2F261A4AX E2 F263A4AX
FT-21 Case 20 2.5 480 4.8 9.6 ! 19.2 x Tr 20 5/6 E2F411A4AA I E2F413A4AA

an
* For Primary Rated registers see Ordering Instructions on page 6.

Case Dimensions: For reference only ( Inches)

,,,-ff::: �
Front View Side View

Shipping
Type
� imensions ( Inches)
Carton Length TWic!i;:;···
I,,
tM
I Height
---r--�--+-3 -3/16

r- 1------..."
.J
ar
Quantity

D5B-2FM 17 1/2 12
lP

For Panel Cutout Dimensions and


ca

Terminal and Mounting Hardware,


see page 12.
tri
lec
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 2 4

05B-7FM Polyphase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 34
2-Stator for 3-Phase 4-Wire Delta
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Registers Class 4/8, Standard F SKW = 400 and 800%of test kVA

See page 15for Service Connections

ls
Tr = E f fective C T Ratio x effective V T Ratio
Type Class Test Volts Kh Full Scale kW Register Style Numbers

I �
#Terminals Amps and Multiplier* Ratio
4-Dial

ua
Case Size
15 Minute 30 Minute
I
Interval Interval

!
-------- ------- --

D5B-7FM Switchboard Type


Transformer-Rated 20 2.5 240 I 2.4 4.8/9.6 x Tr 41 2/3 E7F261A4AX E7F263A4AX
I
10-Terminal 20 2.5 480 4.8 9.6/19.2 x Tr 20 5/6 E7F411A4AA E7F413A4AA
FT-21 Case

an
* For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights (Approximate in Pounds) Case Dimensions: For reference only ( n


I ches)
Type Carton Domestic Export Front View Side View
I I I

tM
Quantity
Net Shipping Net Legal Gross 6-3/8 �721321
D5B-7FM 1 12 I 14 12
I 14
i 24
-t---r---1- 3-3116 1191321 J -6-1,16 1
Shipping Dimensions ( Inches)
,

Type Carton Length Width Height -'


ar
Quantity

D5B-7FM 1 17 11 1/2 12
lP

For Panel Cutout Dimensions and


ca

Terminal and Mounting Hardware,


see page 1 4.
tri
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C

Page 2 5

D5B-8FM Polyphase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 3 4
2-Stator for 3-Phase 4-Wire Wye
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Registers Class 4/8, Standard F SKW = 400 and 800%o f test kVA

72 volt meters are of r use on 69.2/ 120V circuits.

ls
120 volt meters are for use on 120/20 8V circuits.
2 40 volt meters are for use on 265/ 460V or 277/ 4 80V circuits.

- - f----

ua
See page 17 for Service Connections
Tr = E f fective C T Ratio x e f fective V T Ratio
Type : Class i Test I volts Kh I Full Scale kW Register Style Numbers
I
#Terminals Amps I and Multiplier* Ratio
4-Dial

I
Case Size - ------- -

15 Minute 30 Minute

I
Interval Interval

an
D5B-8FM Switchboard Type
!
20 2.5 72 1.08 2.16/4.32 x Tr 92 16127 E8F711A4AA E8F713A4AA
Transformer-Rated 20 2.5 120 1.8 '
3.6 /7.2 x Tr 55 5/9 E8F111A4AA E8F113A4AA
10-Terminal 20 2.5 240 3.6 7.2 .'14.4 x Tr 27 7/9 E8F211A4AA E8F213A4AA
FT-21 Case - ---
-

• For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights (Approximate in Pounds)


Type

D5B-8FM
Carton
Quantity

1
Domestic

Net

12
I
I
Shipping

14
Export

Net

12
I
I
Legal

14
I
I
tM
Gross

24
Case Dimensions: For re ference only ( Inches)
Front View

'" ,-ff:.·::
Side View
ar
Shipping Dimensions ( n
I ches) - 1------...,

I
.J
Type Carton Length Width Height
Quantity

I
J
lP

J �r-__,s�916
D5B-8FM 1 17 11 1/2 12
L J
ca

14

For Panel Cutout Dimensions and


Terminal and Mounting Hardware,
see page 16.
tri
lec
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 26

D5B-3FM Polyphase Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 483 4
3-Stator for 3-Phase 4-Wire Wye
Mark Ia Dual-Range Indicating Mechanical Demand Register
Transformer-Rated Registers Class 4/8, Standa d
r FSK W = 400 and 800%of test kVA

72 volt meters are fo ruse on 69.2/ 120V circuits.

ls
120 volt meters are for use on 120/20 8V circuits.
240 volt meters are for use on 265/ 460V or 277/ 4 80V circuits.
See page 19for Service Connections

ua
Tr = Effective C T Ratio x effective V T Ratio

!
I
I
Type Class Test Volts Kh Full Scale kW Register Style Numbers
#Terminals Amps and Mu ltiplier* Ratio
4-Dial 30 Minute
Case Size
I
I
15 Minute Interval
'
Interval

D5B-3FM Switchboard Type 20 2.5 72 1.08 2.16/4.32 x Tr 92 16/27 E3F711A4AA E3F713A4AA

an
i
Transformer-Rated 20 2.5 120 1.8 3.6/7.2 x Tr 55 5/9 E3F1 11A4AA E3F113A4AA

i !
1 0-Terminal 20 2.5 240 3.6 7.2/14.4 x Tr 27 7/9 E3F211A4AA E3F213A4AA
FT-21 Case

* For Pnmary Rated reg1sters see Ordenng Instructions on page 6.

tM
Shipping Weights (App o
r x mate
i in Pounds) Case Dimensions: For reference only ( Inches)

r-- 6·318- �7·21/32 1


3-3/16 1 191321 J- 6 1/16 1
Type Carton Domestic Export Front View Side View
I I I
3·3/16
Quantity Legal Gross
Net Shipping Net

D5B-3FM 1 12 I 14 12
I 14 I 24

I
ar
rt -·- -7132
Shipping Dimensions ( Inches) 1
..J
Type Carton Length Width Height

10-7/32 -t-
Quantity

D5B-3FM 1 17 11 1/2 12

-7132
-
lP

1± �
I
ca

For Panel Cutout Dimensions and


Terminal and Mounting Hardwa er ,
see page 1 8.
tri
lec
.E
w
ww

October, 1988
om
C at alog
42-100C

P age 27

058-FM Single-Phase Switchboard Watthour Demand Meters

.c
Mark l i l a Register Product Code 48 3 3
1 -Stator for 1 -Phase 3-Wire
Mark lila Clock-Dial Mec h anic al Dem and Register
Transformer-Rated Registers Class 6, St and ard F SKW = 666%%of test kVA

See p age 9for Service Connections

I AmT espst I Vol t s I and


Tr Effective

ls
I R e g is t er
= C T R atio x effective V T R atio
Ty pe - -----rG a
1 ss Fu ll Scal e kW
I I Kh Style Numbers
r--

i
#T erminals Mul t i plie r•

·� ""'"
4 -Dial 30 M inu t e

I
Case S i z e
1

I
15 Minu t e Int erval
I

ua
I nt erval
r I 4 .0 x T r
__

I
058-FM Switchboard Type
2 240 06 /
T ransform er - Rat ed
6- T erminal
10 1 5. _L3 E CF281A4AZ E CF283A4AZ
FT - 21 Case
For Primary Rated r e gis t ers see Ordering Instructions on pag e 6.
l

an

6-3/8 rr721/32 1
Shipping Weights (Approxim ate in Pounds) Case Dimensions: For reference on y
l (n
I ches)
Typ e Car ton Dom es t ic Expor t

3-3/16 3-3/16 1 19/321 }-- 6·1116 1


Front View Side View
Quanti t y N e t I Shippin g N e t I L e gal I Gross

tM
058-FM 1 1 2 I 14 1 2 I 14 I 24 -t--�>---'1-

Shipping Dimensions (Inches)


Typ e Car ton L en g th Wid t h H ei g h t
"
..J

Quan t i t y
058-F M 1 17 11 1 /2 12
ar
lP

For P anel Cutout Dimensions and


Termin al and Mounting H ardw are,
ca

see p age 8 .
tri
lec
.E
w
ww

October, 1988
Ca ta og
l

om
42-100C

Page 2 8

058-FM S i ngle-Phase Switchboard Watthour Demand Meters

.c
Mark l i l a Register Product Code 48 3 3
1 -Stator for 1 -Phase 2-Wire
Mark lila Clock-Dial Mechanical Demand Register
Transformer-Rated Registers Class 6, Standard FSKW = 666 2/3% of test kVA

-r1
See page 1 1 for Service Connections

ls
Tr = Effec it ve CT Ra tio x effec tive V T Ra tio
!Test
-_j_
- 30Int erMivnalut e -
Ty pe ! C l ass Volt s Kh Full Sc al e kW R egi st er Style Numbers
# Termin al s
- --

Amps and Mult i pli er* R atio

-
4-0i al
I
- ------
C ase S iz e --�15Minut e

ua
" 1
-Int erv---
L_ al
� --
_

058-FM Switchboard Type


Tran sfo rmer-R at ed 10 5- 120 0.3 2.0 x Tr 333 1/3 EAF 131A4AA EAF133A4AA
4- Termin al 10 2.5 240 0.6 4.0 x Tr 166 2/3 EAF281A4AZ EAF 283A4AZ
FT-21 C ase

an
* Fo r Primary Rated reg i st e rs see Ordering Instructions on pag e 6.

-- ---- --
Case Dimensions: For reference only I( nches)

Do m estic ---- - �;rt -


Shipping Weights (Approx i ma te n
- i Pounds )
-
c;;rto �
r---;- 1
I 1 J-6 1 / 1 6 1
Ty pe Front View Side View
� - Qu antit � N �t Shi pping · � � - _ Leg a i _TG ro ;;; 7 21 32
058- FM . - _1__ _ __j 12
- _ _ __l___1_
4 __:___ 24_

tM
- 14 12 3·3/1 6 -+--.,...�-+- 3 -3�� 1 6 32
_ ___ __ _
- _
1 19

Shipping Dimensions ( Inches) ,

Ty pe C ar ton .J

Qu antity
ar
058- FM
lP

For Panel Cu tou t D mensions


i and
Term nal
i and Moun ting Hardware,
ca

see page 10.


tri
lec
.E
w
ww

October, 1988
Cl

om
Catalog
42-100C

Page 29

D5B-2FM Polyphase Switchboard Watthour Demand Meters

.c
Mark li l a Register Product Code 48 3 4
2-Stator for 3-Phase 3-Wire or Network
Mark lila Clock-Dial Mechanical Demand Register
Transformer-Rated Reg isters Class 8, Standard FSKW = 800% of test kVA

.1
See page 1 3for Service Connections

ls
Tr = Effective C T Rat o
i x effective V T Ratio
Type Cl ass Test Volts Kh Full Sc ale kW ----R---r- eg i�te r Style Numbers
# Te rmin als Amps and Multiplie r• R atio 4-Di al
Case Si ze

ua
15 Minute 30 Minute
Inte rv al Inte rv al
05B-2FM Switchboard Type 20 2.5 72 0.72 2.88 x T r 138 819 E2F731A4AA E2F733A4AA
Transfo rme r-R ated 20 2.5 120 1.2 4.8 x Tr 83 113 E2F181A4AY E2F183A4AY
10-Te rmin al 20 2.5 240 2.4 9.6 x Tr 41 2:3 E2F281A4AX E2F283A4AX
FT-21 Case 20 2.5 480 4.8 19 .2 x T r 20 516 E2F431A4AA E2F433A4AA

an
• Fo r Primary- -----
Rated registe rs see Ordering Instructions on p----�--�- -age 6.

Shipping Weights (Approxi mate in Pounds) Case Dimensions: For reference only ( nches)
I

Type Carton Domestic Expo rt Front View Side View


_ _ it_ Y_ ____N_et_ _+l_ _S_ hi_.p_._p_in_.g'---+-_ N_e_t
O_u_ ant

-ff: �:1
Leg a I , Gross

tM
___
·----

D5B-2FM 12 14 12 14 24

L=
-�----- -- - ----

r- 1------.... ,
Shipping Dimensions ( nches)
I , ,, ,

I _:
Typ-;;-- -�Cart��- ---- Length W idt h .J

- Ou ant t1y
ar
D5B-2FM 1 17 11 1/2 _
lP

For Panel Cutout Di mensions and


ca

Ter minal and Mounting Hard ware,


see page 12.
tri
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C
Page 32

D5B-3FM Polyphase Switchboard Watthour Demand Meters

.c
Mark l i la Register Product Code 483 4
3-Stator for 3-Phase 4-Wire Wye
Mark lila Clock-Dial Mechanical Demand Register
Transformer-Rated Registers Class 8, Standard FSKW = 800% of test kVA

72 volt meters are for use on 69.2 / 120V circ ui s


t.

ls
120 vo tl meters are for use on 120 20
/ 8V circuits.
2 40 volt meters are for use on 2 65 /4 60V or 277/4 80V c rcu
i ts.
i
See page 19for Service Connections

-----,---
Tr = Effective C T Ratio xeffect ve
i V T Ratio

ua
· ·,---------­

·
--�-

Type Class Test Volts Kh F u l l Scale kW Register Style Numbers

h:
�� �---�-----
# Term i n a ls Amps a n d M u lti p l i e r • Ratio
4-D i a l
Case Size
1 5 M i n ute 30 M i n ute
Interval I nterval

D5B-3FM Switchboard Type


1
2.5 72 1 .08 4.32 x Tr 92 1 6/27 E3F731 A4AA E3F733A4AA

an
Transformer-Rated 2.5 1 20 1 .8 7.2 X Tr 55 5/9 E 3 F 1 3 1 A4AA E 3 F 1 33A4AA
1 0-Term i n a l 2.5 240 3.6 1 4.4 x Tr 27 7/9 E3F231 A4AA E3F233A4AA
FT-21 Case
i ------- " .. �
· ------ ·-
• For Primary Rated registers see Ordering Instructions o n page 6.

tM
Shipping Weights (Appro xi mate in Po unds) Case Dimensions: For reference only ( Inches)
Type Export Front View Side View
Shipping Net Gross 6-318 �7 21•32 1
D5B-3FM
--------�--J_
14 12 24 -+--�--+- 3·3 16 1 19321 J-6 1/16 1
ar
Shipping Dimensions ( Inches)

��------
,
..J
Type Carton Length Width Height
, Qua ntity

D5B-3FM
�r-· 1 17 1 1 1 /2 12
lP
---- --------
ca

For Panel C uto ut Dimensions and


Ter minal and Mo unting Hardware,
see page 1 8.
tri
lec
.E
w
ww

October, 1 988
om
Reactive Meteri n g Catalog
42-100C
Page 33

.c
D5B-2F, 058-SF, D5B-3F Polyphase Switchboard Watthour Meters for Varhour Metering
Polyphase switc h bo a rd meters ca n be s u p p l i e d fo r v a r h o u r m ete r i n g . See Ordering Instructions for m eters with Special
Features on pa g e 6. O rd e r as "Si m i l a r to" style n u m be r meter except fo r va r h o u r mete r i n g .

Service Connection Diagrams

ls
All d i a g ra m s a re rear view

Cu rrent C l o s i n g Switches a re Operated by Test Switch H a n d l e and Also by Removal of Chassis

ua
Switchboard-Type D5B-2F Switchboard-Type D5B-3F
Diagram of 3 Phase r------ Demand Motor Leads
3 Wire Auto Trans­ When Used on 72V.
former Connected to Supply only. Connect
System H a v i n g 1 ·2·3 to Terminals 15 & 1 6
Phase Sequence 141·
151 Lag 1 ·2 o r 90"

an
161·171 Lags 3·2 by
90

tM iJ
I
I
Connections are Shown for
Forward Rotation of Meter
or Lag g i n g Power Factor When
Phase Sequence is 1, 2, 3
ar
Front
View
lP

Switchboard-Type D5B-8F
ca

-. --t=¥J==::=t=f===-----J�f_-H- ' L
Diagram of 3 Phase

'
- 8A- - 7a-
_
4 Wire Auto Transformers r
Demand Motor When L
(�'; :��-; (�J �
- -6c -

Demand Contacts .... ... ... /., ;


Connected to System , - - -

Having 1 ·2·3 Phase 1 Used or Internal 0 ' I


Power Supply A , N

�i
Sequence 141·151 Lags ..-- - - o Neutral
1 ·0 o r 90" 181·191 Lags 0 E
3·0 by 90" Voltage Trans. Conn. �
tri

t:v:J W W
{ Current Test Jack
. .�� 1, L
0
lec

A
D
Circuit Closing
Rear View ... Device

Note
For D5B-3F switchboard meters for reactive mete ring a n FT-32 case
is s u p p l ied at an a d d i t i o n a l cost.
.E

For price adder - See Price List 42-020.

L
0 2
'=t==t==�=j����tt===' --- 2 1
L

A ' ' N
D o o E
w

Rear View
ww

October, 1 988
om
Catalog
42-100C
Page 34

058-3 1 F Single-Phase Totalizing Switchboard Watthour Meters

.c
3-Stator for Totalizing 3-Circuits 1-Phase 2-Wire Product Code 48 2 4

CCC
Service Input Schematics 1 -Phase
2-Wire

ls
[
Tr Effective CT ratio x effective VT ratio

I I
I
I
=

I
---�-Pet
I Style Numbers

I
Ty pe Class Test Volts Kh Register Reg i ster

I
I

ua
# Te r m i n a l s Amps M u lti- Ratio
I I t---------1
I
Standard Clock D i a l Drum-Type Cyclometer

lI
Ca se Size plier*

'I
,

!
I
4-Dial 5-Dial 4-Drum 5-Drum

! I
I
- --

I
05 B-31 F Switchboard Type
Tra nsformer-Rated 20
I 2.5
I
1 20

I
1.8 Tr

I
55 5/9 EAL 1 CLA4AA EAL1 CLA5AA EAL1 CYA4AA
I EAL1 CYA5AA

I I i
20 -Te r m i n a l 20 2.5 240 3.6 Tr 27 7/9 EAL2CLA4AA EAL2CLA5AA EAL2CYA4AA EAL2CYA5AA
FT-32 Case
I I I _______l

an
___l_ ____ '----
-- -

* For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights (Approximate in Pou nds) Case Dimensions: F o r reference o n ly ( I nches)


I Front View Side View
I
Type Carton

tM
Quantity

I
, Net

D5B-3 1 F 1 I 19

j_
'
I 1I
Shipping Carton Dimensions ( I nches)
Type
�C
arton Length Width _ H e i g ht
ar
u a ntity _

D5B- 3 1 F____L____________L____
_
1 2 __
2 1 ______�____ __ �1 ____
1 2 1 12
____
lP
ca

Panel Cutout Dimensions ( F ront View ) : Terminal and Mounting Hardware:


F o r reference o n l y ( I nches)
tri

For reference o n l y ( I nches )


Semi-Flush Projection Semi-Flush Mounting Projection Mounting

7n
lec

Spacer forThi n Panel (Up to 1�)

r
78 7 � .190 -32
Screw 1�-lB Screw

t
- (For Thick
Panel Use
1�-lB Stud)

�1
7

Jj_
.E

i .190-32
Screw
---e-- - ---e- (For Thick
Panel Use
.190-32
Stud)
w

�Diameter
Note 1 :
Special cutout req u i red for FT-32 case with isolated term i n a l s for L<l-o<----- Panel
D5B-31 F or D5B-31 FM when used for reactive metering or tota l izing
ww

sing le-ph ase circuits. ( O n e to fou r cutouts m a y be req u i red depend­


i n g on the a p p l i cati o n . )

October, 1988
om
Cl
Catalog
42-100C
Page 35

D5B-3 1 F Single-Phase Totalizing Switchboard Watthour Meters


Service Connection Diagrams for Totalizing 3-Circuits of 1-Phase 2-Wire Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-3 1 F
A l l d i a g ra m s a r e rear view

Cu rrent Closing Switches are Operated by Test Switch H a n d l e and Also by Removal of Ch assis

ls
voltage tra n sformers when used shou l d be co n n ected as shown below

::::;

ua
0 w
<t z
0

.
-'

L f• t
• II
w
z

an
::::;

r 1

I" '7 "1"1 "1 m� I


J
1
I
I
tM 14
14 • •� ••• • II
l
�19 • 2D
--a._
I

I
K , Y , Z DEMAND
CONTACTS WHEN
REQUIRED

r�rf
CURRENT TEST
ar
JACKS INTERNAL POWER
SUPPLY O R DEMAN D

I
MOW' we" " '"

M
•---,. CIRCUIT CLOSING
DEVICE

�.u J.
lP

:L•.n
o
.n .
ca
tri

� _.__
==7=:-J
.• .J
� ==-::::jF"
t:====3
"l �==-=:::tE =�== �
lec

voltage tra n sformers w h e n used s h o u l d be con nected as shown above


.E
w
ww

October, 1988
om
Catalog
42-100C
Page 36

D5B-32F Polyphase Totalizing Switchboard Watthour Meters


4-Stator for Totalizing 2-Circuits of 3-Phase 3-Wire or 4 -Circuits of 1 -Phase 2-Wire

.c

Product Code 48 2 4

ecce
Service Input 3-Phase 1 -Phase
Schematics 3-Wire 2-Wire

ls
I
Tr Effective CT ratio x effective VT ratio
-------- -- ------------
I I

:
[ Reg i;ter Style �u m be___

I
sr

· r·
Type Class Test Volts Kh Reg ister
___ ___________ ___________ ___

I
I
# Te r m i n a l s ' Amps M u lti- Ratio

ua
- -
�I
Standard Clock D i a l Drum-Type Cyclomet er___ _
Case Size pl ier* __
- - 5-D i a l 4-Drur!l :
5 Dru m

1 I
_
o5s-32i= switchboard Type

I
Transformer-Rated 20 2.5 41 2/3 E2M 1 CLA4AA E 2 M 1 CLA5AA E 2 M 1 CYA4AA E 2 M 1 CYA5AA

i I I
20-Ter m i n a l 20 2.5 20 5/6 E2M2CLA4AA E2M2CLA5AA E2M2CYA4AA E2M 2CY 5AA

-FT-21
------· - --- -- -
Case � �

an
* For Primary Rated registers see Ordering Instructions on page 6.

1
Shipping Weights (Approxi mate in Pou nds) Case Dimensions: For reference o n l y ( I nches)
I .
- I Front View Side View

I

Type Carton Domestic Export
0 u ant i t ]

tM
-- Net S h i PP i n g i N et G ro ss

] I
- -- +___ ._.__--_--- ___ _I--__...__--+____
t
D5B-32F 1 19 21 ·- 19 35
. -�--�---

li
Shi !' ping Carton Dimensions ( I nches)
Type Carton Length Width -·r-- Height
Quantity
ar
_L

D5B-32F 1 21 12 1 2 1 /2
____L______ __ _ ___L____
16

IT
__
lP

l1
_

'---::_-,.-T-_-_J
ca

Panel Cutout Dimensions (Front View) : Terminal and Mounting Hardware:


tri

For reference o n l y ( I nches) For reference only ( I nches)


Semi-Flush Projection Semi-Flush Mounting Projection Mounting

7T
lec

Spacer for Thin Panel (Up to 1�)

r
78 � .190-32
7 Screw �-l8 Screw

l
(For ThiCk
Panel Use
�-1 8 Stud)

1
.E

7
� i .190-32
Screw
(For Thick
Panel Use
.190-32
Stud)
w

�Diameter
Note 1 :
Special cutout req u i red for FT-32 case with isolated term i n a l s for
!.-l-or--- Panel
ww

D5B-32F or D5B-32FM when used for reactive metering or tota l izing


s i n g l e-phase ci rcuits. ( O n e to fou r cutouts m a y be req u i red depend­
ing on the a p p l i cati o n . )

October, 1988
om
Catalog
42-100C

Page 37

05B-32F Polyphase Totalizing Switchboard Watthour Meters


Service Connection Diagrams for Totalizing 2-Circuits of 3-Phase 3-Wire or 4-Circuits of

.c
1-Phase 2-Wire Watthour and Demand Meters
Switchboard-Type 05B-32F
All d i a g ra m s are rea r view

Cu rrent Closing Switches a re Ope rated by Test Switch H a n d l e a n d Also by Removal of Chassis

ls
Totalizing 2-Circuits of 3-Phase 3-Wire Totalizing 4-Circuits of 1 -Phase 2-Wire

ua
LJ LJ
====:=u=:;=::J=== :
0 w O

-' -'
UJ

-'
0 4: z 4: z

-'
4: 0 - 0 �
0

� -n--; II
---!"" ' ' 17
•• 20

c��. �
�20

an
voltage transformers when used s h o u l d be voltage transformers w h e n u s e d s h o u l d b e
con nected as shown a bove con nected as shown a bove

K, Y, Z DEMAND CONTACTS
8-A, 7-B, 6-C PHOTOELECTRIC
SENSING DEVICE CONTACTS
tM K, Y, Z DEMAND CONTACTS
ar
8-A,?-8,6-C PHOTOELECTRIC
SENSING DEVICE CONTACTS

.... CIRCUIT CLOSING


DEVICE

'1
lP

-' CURRENT TEST


JACKS

� CURRENT TEST
JACKS

INTERNAL POWER
ca

SUPPLY O R
DEMAND MOTOR 3-9,4- 1 0, 1 3- 1 9 , 1 4-20
WHEN USED ARE EXTERNAL
JUMPERS

�O���
±:l=t==f:==:j POS. K FOR
CT
POS. Y FOR 3-WIRE
tri

CONTACT
lec

voltage transformers when used s h o u l d be


con nected as shown below
voltage transformers when used s h o u l d be
con nected as shown below
.E

10
4

-T_j__j -T_j__j
0

g
4: ------
--

�1\c&
-+ ....--- · z
::J
UJ
0

-'
4:
0 E?
w O

-' g
z <>:
E?
UJ
z

w
ww

October, 1988
om
Catalog
42-100C

Page 38

D5B-38F Polyphase Totalizing Switchboard Watthour Meters

.c
4-Stator for Totaliz ing 2-Circuits of 3-Phase 4-Wire Wye Product Code 48 24
Service Input 3-Phase Notes:
Schematic 4-Wire 72 volt meters a re for use on 69.2/1 20V circuits.
Wye 1 20 volt meters a re for use on 1 20/208V circu its.
Neutral Neutral
240 volt meters are for u se o n 265/460 o r 277/480V c i rcu its.

ls
ua
Tr = Effective CT ratio x effective VT ratio
Type Class Test Volts Kh Register Register Style Numbers
# Te r m i n a l s Amps M u lti- Ratio
Standard Clock D i a l D r u m -Type Cyclometer
Case Size plier*
4-Dial 5-Di a l 4-Drum 5-Drum

D5B-38F Switchboard Type

an
20 2.5 72 2.16 Tr 46 8/27 E8P7CLA4AA E8P7CLA5AA E8P7CYA4AA E8P7CYA5AA
Transformer-Rated 20 2.5 120 3.6 Tr 27 7/9 E8P 1 C LA4AA E8P 1 C LA5AA E8P1 CYA4AA E8P1 CYA5AA
20-Te r m i n a l 20 2.5 240 7.2 Tr 13 8/9 E8P2CLA4AA E8P2CLA5AA E8P2CYA4AA E8P2CYA5AA
FT-32 Case

• For Primary Rated registers see Ordering Instructions on page 6.

tM
Shipping Weights (Approximate i n Po un ds ) Case Dimensions: For reference o n l y ( I nches)
Type Carton Domestic Export Front View Side View
I I I
Quantity N et
Net Shipping Legal Gross

D5B-38F 1 19
I 21 19
l 21
1 35
ar
1r
Shipping Carton Dimensions ( I nches)
Type Carton Length Width Height
Quantity

16�
D5B-38F 1 21 12 1 2 1 /2
lP

!T r---
11
ca

....-
- ---
. -
-_
..._ __ -
tri

Panel Cutout Dimensions (Front View): Terminal and Mounting Hardware:


For reference only ( I nches) For reference only ( I nches)
Semi-Flush Projection Semi-Flush Mounting Projection Mounting
lec

7 -r Spacer for Thin Panel (Up to 1f;)

r
7s
7 :;! .190-32
Screw
1%-lS Screw

t
.E

- (For Thick
Panel Use
1i-18 Stud)

1
7

i .190-32
Screw
(For Thick
Panel Use
w

.190-32
Stud )
ww

�Diameter
Note 1 :
Specia l cutout req u i red for FT-32 case with isolated ter m i n a l s for IL}oo--- Panel
D5B-38F or D5B-38FM when u sed for reactive mete r i n g . (One to
fo u r cutouts m ay be req u i red depen d i n g o n the a ppl ication . )

October, 1988
om
Catalog
42-100C

Page 39

D5B-38F Polyphase Totalizing Switchboard Watthour Meters


Service Connection Diagrams for Totalizing 2-Circuits of 3-Phase 4-Wire Wye Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-38F
Al l d i a g ra m s a re rear v i ew

Cu rrent Closing Switches a re Operated by Test Switch H a n d l e a n d Also by Removal of Chassis

I2 -Z

ls
NEUTRAL
0 ...

2J2J
0

""
0

ua
�1J20
...J 3 ...J

voltage transformers when used s h o u l d be con nected as shown a bove

an
0 -� ...f--------+N:.::E::U�TR:,:::AL::;_ O ..,

K, Y, Z DEMAND CONTACTS
A-8, B-6, & C-7 PHOTOELECTRIC
PULSE I NITIATOR WITH
EXTERNAL POWER SU PPLY

tM
r---'=t==F���---, 20
ar
. ... CIRCUIT CLOSING
DEVICE

t
lP

CURRENT TEST
JACK

INTERNAL POWER
SUPPLY OR
ca

DEMAND MOTOR
WHEN USED

NOTE - DEMAND MOTOR


CONNECT ACROSS
1 1 & 13 FOR 72 VOLT
SERVICE ,,
tri

'

END OF
INTERVAL TIME
PULSE R E G I STER
NOT USED FOR 2-WIRE
WHEN USED
CONTACTS ___
lec

"" ------+-r-���-+_,---- ;2 z
.E

0 ------����-4---- 3 -

r
voltage transformers when used s h o u l d be con nected as shown below
lO H I t

� �Et�tts �
2:s -Z
w

J W

0 -'
ww

October, 1988
om
Catalog
42-100C
Page 40

D5B-33F Polyphase Totalizing Switchboard Watthour Meters

.c
6-Stator for Totalizing 2-Circuits of 3-Phase 4-Wire Wye Product Code 48 24
Service Input 3-Phase Notes:
Schematics 4 -Wire
WY E
72 volt meters are for use on 69.2/1 20V ci rcuits.
Neutral Neutral 1 20 volt meters are for use on 1 20/208V ci rcuits.
240 volt meters a re for u se on 265/460 o r 277/480V ci rcuits.

ls
Reg is t � g is e

ua
Tr Effective CT ratio x effective VT ratio

I r�-�
i �
=

ti -Volt s
Ty pe - -- (�siTe;:
I Am ps
. . Ratiot r
# Terminals
I I _L- iter* ul ti-
--

Case Size l meter ____ _


Drum - T y pe Cy c o
.
.

D5B-33F Switchboard Typ� 20- 12.5 --+-J�


-
� 2 .16 -�- T r
J. -46 8/ 27- �.2:_[l_i_'l I
E 3R7 CLA5AA
_____
4 - D �UrTl__ �-D rurTl__ _
E 3R7 CYA4AA ' E 3 R7 CYA5AA
T ransformer- Rated 20 2.5 I 1 ;0 3.6 Tr I 27 7/9 E 3R 1 CLA5AA E 3R1 CYA4AA E 3R1 CYA5AA
___

,I E 3R 2C LA5AA

an
____j____ _
20 -Terminal , 20 I 2 5. I 240 : 7 .2 Tr ' 1 3 8/9 E 3R 2CYA4AA E 3R 2CYA5AA
FT -32 Case ___ _j ____L__jL__ ___ ___L_
1

_ _ _ _ __ _ ___ _

' For Primary Rated reg is e


t rs see Ordering Instructions on page6.
_ _
__

TExp�

tM
Shipping Weights (Approx i m ate in Pounds) Case Dimensions: For reference o n l y ( I nches)
Ty pe � Car t a�----, -�es�
__ � �
Front View Side View
-- -- -- -

egal �- Gro-s�
-

_.J o uan t
i t y 1 - Net ppin g ---f--N

-
-
D5B :33-� 1 ---- -t 2-1 - - 23 -- ���3-=r�37
- --

1=
ar
Shipping Carton Dimensions ( I nches)
h -- jw� IHei gh t
_ ____j__
Ty pe -T �t -�-- Leng t-
_ Ouan�
D5B- 33F-- ___L_ 1 ___ _ _
-_ __ 21--- ---t ··
12 I 1 2 1/ 2
lP
ca

Panel Cutout Dimensions (Front View): Terminal and Mounting Hardware:


tri

For reference o n l y ( I nches) For reference only ( I nches)


Semi-Flush Projection Semi-Flush Mounting Projection Mounting

7n
lec

Spacer for Thin Panel ( Up to 1�)

r -
78 � .190-32
7 Screw �-18 Screw

t
( For Thtck
Panel Use
1�·18 Stud )

1
.E

7
� i .190-32
Screw
( For T hiCk
Panel Use
.190-32
Stud )
w

Note 1 :
�Dtameter
Spec i a l cutout req u i red for FT-32 case with isolated term i n a l s for
!,"---- Panel
ww

D5B-33F o r D5B-33FM when used for reactive mete r i n g . (One to


fo u r cutouts may be req u i red depend i n g on the a p p l i cati o n . )

October, 1988
om
Catalog
42-100C
Page 41

D5B-33F Polyphase Totalizing Switchboard Watthour Meters


Service Connecti on Di agrams for Tota l i z i ng 2-Circuits of 3-Phase 4-Wire Wye Service

.c
Watthour and Demand Meters
Switchboard-Type D5B-33F
All d i a g rams a re rea r v i ew

Cu rrent Closing Switches a re Operated by Test Switch H a n d l e a n d Also by Removal of Chassis

ls
ua
voltage transfo r m e rs when used s h o u l d be con nected as shown above

an
NEUTRAL O ..,

tM
ar
lP
ca

D E M A N D MOTOR
L_.:....:..____:::::�:;::i::f" I OR INTERNAL
POWER SUPPLY
L - - - - - - - - ..r-,/\1'.,/'v-- - - - _I W H E N USED

NOTE: D E M A N D MOTOR
NOT U S E D FOR 2-WIRE LEADS CONNECTED
tri

CONTACTS ________.. ACROSS 1 -3 FOR 72V.


SERVICE

... CIRCUIT CLO S I N G


DEVICE
lec

I CURRENT TEST JACK


EXTERNAL J U M P E R S
9-7-5 AND 1 9-1 7-1 5
.E

c:rml
voltage tran sformers when used s h o u l d be connected as shown below

lO
;:LJ
F
w

p��=-
0 I L.J

.. 2 z
ww

0 3 -

0 -'

October, 1 988
Cl

om
Catalog
42-100C

Page 42

D5B-34F Polyphase Totalizing Switchboard Watthour Meters

[2: [2: [2:


6-Stator for Totalizing 3-Circuits of 3-Phase 3-Wire De lta or for Totalizing 6-Circuits of

.c
1-Phase 2-Wire Product Code 48 2 4
3-Pha se 1-Pha se

[ [ [ [[[
Service Input
Schematic 3-W ire 2-Wire
Delta

ls
Tr Effective CT ratio x effective VT ratio

I
I Regi ster
=

I I I
-- ---··-- -·---

Type Cla ss Te st Volt s Kh Regi ste r Style Numbers


# T e rm inal s Multi -

ua
Amp s Ratio Drum -Type Cyclomete r
II
Ca se Size
·

p lie r* Standa rd Clo ck Dia l

i
I I I
4-Dia l I 5-Dial 4-Drum 5-Drum
058-34F Switchboard Type 1.

I I I
I

I 240 I 7.2 Tr
Tran sfo rme r-Rated 20 2.5 120 3.6 T r 27 7/9 E4T1C LA4AA E4T1C L A5AA E4T1C YA4AA E4T1C YA5AA
� I I
26-Te rm inal 20 13 8/9 E4T2C L A4AA E4T2C LA5AA E4T2C YA4AA E4T2C YA5AA
FT -32Ca se I I i

an
' Fo r Primary Rated regi ster s see Ordering Instructions o n page 6.

Shipping Weights (Appro x i m ate in Pounds) Case D i m ensions : For reference o n l y ( I nches)
Type Ca rtonI I Front View Side View
_ ___l �ity

tM
- -
Gro ss
D5B-� l__1___ 37

b 1f
__- ---- - -- -
Ty�
Shipping Carton Dimensions ( l n c h es )
__ ___c
Ca rton . � Lengt h , W idt h- , -Heig ht
- --�1 �t it_L__ ' -+
ar
I--

l6h
---- ---- ----

D5B-3� __ 1_____ _ 2_1____j_ 1_2____j___ 12 1/2 _

r-- -
_

IT
lP
ca

Panel Cutout Dimensions (Front View): Terminal and Mounting Hardware:


tri

For refe rence only ( I nches) For refe rence o n l y ( I nches)


Semi-Flush Semi-Flush Mounting Projection Mounting

7n
lec

Spacer for Thin Panel (Upto 1�)

r
78 7 ';1 .190-32
Screw 1�-18 Screw

t
- ( For Thick
Panel Use
�-18 Stud)

�1
7
.E

�·--e-- · i-e-
.190-32
Screw
(For Thick
Panel Use
.190-32
Stud)
w

�Diameter
Note 1 :
Speci a l cutout req u i red for FT-32 case with isolated te r m i n a l s for I.-l-or--- Panel
ww

D5B-34F o r D5B-34FM when used for reactive metering . (One to


fou r cutouts may be req u i red depending on the a p p l icati o n . )

October, 1 988
om
Catalog
42-100C

Page 43

DSB-34F Polyphase Totalizing Switchboard Watthour Meters


Service Connection Diagrams for Totalizing 3-Circuits of 3-Phase 3-Wire De l ta or for

.c
Total izing 6-Circuits of 1-Phase 2-Wire Service Watthour and Demand Meters
Switchboard-Type D5B-34F
All diagrams a re rea r view

Cu rrent Closing Switches a re Operated by Test Switch H a n d l e a n d Also by Removal of Chassis

ls
Totalizing 3-Circuits of 3-Phase 3-Wire Delta Totalizing 6-Circu its of 1 -Phase 2-Wire

�: :i LJ
I

ua
:J i g �
I " "

an
voltage transformers when used s h o u l d be voltage transformers wh en used s h o u l d be

:i ----.���­
con nected as shown above con nected as shown a bove

tM
ar '3 -t.,..,.,.,_..,

DEMAND MOTOR OR
INTERNAL POWER SUPPLY
WHEN USED

I
DEMAND MOTOR O R
INTERNAL POWER SU PPLY
WHEN USED

I
lP

NOT U S E D FOR /
2·WIRE CONTACTS
ca

CIRCUIT CLOSING
DEVICE
. ....
CURRENT TEST
JACK
EXTERNAL J U MPERS
7-9,5- 1 9, 1 5- 1 7, 2 1 -22,23-26,
JACK �
C U R R E N T TEST
TER M I NALS N O . 10 & 20
ARE SPARE.
tri

24-25

w
lec

z
::J

voltage transformers when used s h o u l d be voltage transformers when used s h o u l d be

2�
con nected as shown below con nected as shown below
.E


I

� ---+r;E
---+-- - ; � : ""'" I)
w : o =-r= wZ
:J
.....

_J ---------- 3 _J
:J i g
z I <(
w

-
ww

October, 1988
om
Catalog
42-100C
Page 44

058-3 1 FM Single-Phase Totalizing Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 3 3
3-Stator for Totalizing 3 Circu its of 1 -Phase 2-Wire
M a r k Ia D u a l - R a n g e I n d i cating Mech a n i ca l D e m a n d Register
Transformer-Rated Registers C l ass 4/8, Sta n d a rd FSKW = 400 & 800% of test kVA

See page 35 for Service Connections

ls
Tr = Effective CT Ratio x effective VT Ratio
Type 1 Cl ass T e st - � Fu ll S cale kW -� Regi;t-;;- -
Volt s Kh
__
_:
-�S t y_
___ __
be r s --- -�- _--
le_N u m _
1 and Mult ipl ier* 1--- - _-'0--'ia-l�-
I,
# Ter min al s Amp s R at io - __ __
4 �� -
C ase S ize
I I I _L30 Minute

ua
15 M inute
�-r--=-� - t----
I I Interv al Interv al
-----t- ---+------ - _----
DSB-31 FM Switchboard Type
I 20 1 2.5 . 120 11 1.8
- - --

I 27 7 / 9 EA L 2 1 1 A4AA LAL2 �A4AA


T r an sformer-R ated 2.5 3.6/7.2 T r 55 5/9 EAL111A4AA EAL113A4AA
3.6 I 7.2/14 .4 xx T r
20-Termin al
FT -32C ase I
20 240
I ___l___ __ ____ __ _c__-___.L___________ _ _
_

an
* For Primary Rated regi ster s see Ordering Instructions on p age 6. -

Shipping Weights (Appro x i m ate in Pou nds) Case Dimensions: For reference o n l y
--- ·--· ·-- ---- --- -- -- ( I nches)
Front View Side View

tM
� 6-3·8-
3-3/1 6
C arton - �� Le ngth__ _ _Wi� -�--Heig ht
Shipping Carton Dimensions ( I nches)
_ __
Type - -- �--
-
- -

21 __1_, _1_2 __ ] _ 1 2_1 12_

IT -·� -
_
�� __QLJantity _ _ �
ar
___ _ _ __ ___ - -
----- �-- -

05 8-3 1 FM- - ____l___ _1__ ____ 1 _


_
_
I
lP

6- 0. 2 -r- 1-

'

8-1 4
ca
tri

For Panel Cutout Di mensions a n d


Te r m i n a l a n d M o u nting H a rdware,
see page 34.
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C

Page 45

D5B-32FM Polyphase Totalizing Switchboard \1\/atthour Demand Meters

.c
Mark Ia Register Product Code 48 34
4-Stator for Totalizing 2-Circuits of 3-Phase 3-Wire or 4-Circuits of 1 -Phase 2-Wire
Mark Ia D u a l - R a n g e I nd i cating M ec h a n i c a l Demand Register
Transformer-Rated Reg isters C l ass 4/8, Sta n d a rd FSKW = 400 & 800% of test kVA

_
_ T _

ls
See page 37 for Service Connections
Tr = Effective CT Ratio x effective VT Ratio _

I
Type Class Test Volts Kh Full Scale kW Register Style Numbers
I
I
# Terminals , Amps and Multiplier* Ratio 4-Dial

ua
Case S ize
1
-
15 Mi nute 30 M-1nute

1__4.82 .4!_j_ 4.819.611 9.69. 2 x TrTr


-_, _
- t-
I nterva l I nterval
------+ - T- -t-
'

D5B-i2FI\II S;,itch-board Type-�

�$:�;��;:�__ _____ _ _ , 'I


20 ___j_ __ I
2 .5___L 240 1
-

Transformer-Rated 20 2.5 1 20 41 213 E2M 1 6 1 A4AX E2M1 63A4AX

L
X 20 5;6 E2M2 1 1 A4AA E2M213A4AA
_

an
---
* For Primary Rated
registers see Ordering Instructions on page 6.

- ____j_Export
Case Dimensions: For reference only
r
Shipping Weights (Approximate in Pou nds)

+ 1 �
� -- -- ------ - - -
( I n ches)
Type 1 Carton Domest 1 c Front View
-
�Net I Side View

19 I

tM
Quant ity Leg�l
--, -- -
N et S h1pp1n G ross
__
'

1--- 6 -3 8 --
_
D5B-32FM 1 19 21 21 35
- -

- 3-3/16
Ty pe__ Ca r ton -- ---r-l� n-9th"! -
Shipping Carton Dimensions ( I nches)
-
-

_
Width H eight

I
IT ��--
__
ar
QuantitY
1 -- ___1_ 2 1
-
D5B-32FM � �1 __
2 ------,--;, l/2
- - 1
lP

6-1/2 -f-- f.-

'
ca

8-1/4

I
tri

For Panel Cutout Di mensions a n d


Term i n a l a n d M o u nting H a rdware,
see page 36.
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C
Page 46

D5B-38FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 34
4-Stator f o r Totalizing 2-Circuits o f 3-Phase 4-Wire Wye
M a r k Ia D u a l- R a n g e I n dicating M echanical D e m a n d Register
Transformer-Rated Registers Cl ass 4/8, Sta n d a rd FSKW = 400 & 800% of test kVA

ls
72 volt meters are for use on 69.2/1 20V circu its.
1 20 volt meters are for use on 1 20/208V ci rcuits.
240 volt meters a re for use on 265/460V or 277/480V circuits.
See page 39 for Service Connections

p
-
-- ---- � C-la-ss � --T-

ua
� _K
Tr = Effective CT Ratio x effective VT Ratio
1 �
1, Register
' Amps 'J
- -- -
Ty e � e-st Vol t Fu ll Scale � --
___ __

Style Numbers
- h

# Termina l s
- _ --

'I
I I I
and M u ltiplier* Ratio
J 4-Dial
,

J
Case Size 1 , 1 5 Mi nute 30 Minute
Interva l Interval
r- E8P7 1 JA4AA
-
--+--- W _J_ ·2:5 ·
j -+ 2.16 -t-4.32/8. 64 � T-r ·�
_L_
D5B-38FM S�
I 20 J 2.5
itchboard Type 72 - 46 8127 E8P7 1 1 A4AA

an
I 3.6
I _:�/28.8 x Tr
-- -- -

Transformer-Rated ' 1 20 7.211 4.4 Tr , 27 7/9 E8P1 1 1 A4AA E8P1 1 3A4AA


� ---�_2 ._5 J
x
r � 240 7.2 13 8/9 E8P2 1 1 A4AA E8P21 3A4AA
i_
�� �� ���: _
:
__ ___ -��- _
_ _ L_ _ _
_
__

* For Primary Rated registers see Ordering Instructions on page 6.

-

tM
Shipping Weights (Approx i m ate in Pounds) Case Dimensions: For reference o n l y
-- Do
-- ]Exp;-;t ----
� r.J;!Tsh• P P• il
-- ( I nches)
Type Carton mesti c
__ l ouant1 ty Net---r-ie� I Gross_
Front View Side View


j_ 1 9 L -�
_

D5B-_38FM t___2_ __ ' 21 19 IJ_i


_
--6-3/8--
_ _�
_ _
_
ar
3-3/16

�u antity -==±_ _
Shipping Carton Dimensions ( I nches)

±:
Type
__j
- r- Carton Leng-;_;;-- � Widt�----ight
--;:J;

IT ��--
�--12
---

_
D5B-38FM 21 -
1 2 1fZ
-
lP
__
I

6-1 '2 t--- ----


ca

'

8- 1 14
tri

For Panel Cutout Di mensions a n d


lec

Te r m i n a l a n d M o u nting H a rdware,
see page 38.
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 47

D5B-33FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 3 4
6-Stator for Totalizing 2-Circuits o f 3-Phase 4-Wire Wye
M a r k Ia D u a l -Range I nd i cating M echan ical D e m a n d Register
Transformer-Rated Registers Class 4/8, Sta n d a rd FSKW = 400 & 800% of test kVA

72 volt meters a re for use on 69.2/120V c i rcu its.

ls
1 20 volt meters a re for use o n 1 20/208V c i rcu its.
240 volt meters a re for use on 265/460V o r 277/480V circuits.
See page 41 for Service Connections
Tr = Effective CT Ratio x effective VT Ratio

ua
Type Class Test Volts Kh Full Scale kW Register Style Numbers
# Terminals Amps and Multiplier* Ratio 4-Dial
Case Size
1 5 M inute 30 Minute
Interval Interval
D5B-33FM Switchboard Type 20 2.5 72 2. 1 6 4.32/8.64 x Tr 46 8/27 E3R7 1 1 A4AA E3R71 3A4AA

an
Transformer-Rated 20 2.5 1 20 3.6 7.2/14.4 x Tr 27 7/9 E3R1 1 1A4AA E3R 1 1 3A4AA
20-Terminal 20 2.5 240 7.2 1 4.4/28. 8 x Tr 13 8/9 E3R2 1 1 A4AA E3R21 3A4AA
FT-32 Case
* For Primary Rated registers see Ordering I nstructions on page 6.

tM
Shipping Weights (Approx i m ate i n Pounds) Case Dimensions: For refe rence o n l y

�---6�318-- JL721 132j


Type Carton Domestic Export ( I nches)
Quantity Net I Shipping Net I
Legal Gross I
Front View Side View

3-3/16 3-3/16
D58-33FM 1 21 l 23 21 l 23 1 37

, ,, I f"'" I
ar
Shipping Carton Dimensions ( I nches)
Type Carton Length Width Height

IT ��--
Quantity
D58-33FM 1 21 12 12 1 /2
lP

6�1/2 -cr- I-

8-1/4
ca

'

1/4
tri

For Panel Cutout Di mensions a n d


lec

Term i n a l a n d M o u nting Ha rdware,


see page 40.
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 48

D5B-34FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark Ia Register Product Code 48 34
6-Stator for Totalizing 3-Circuits of 3-Phase 3-Wire Delta
or for Totalizing 6-Circuits of 1 -Phase 2-Wire
M a rk Ia D u a l - R a n g e I n d icating Mechanical Demand Register
Transformer-Rated Reg isters C l a ss 4/8, Sta n d a rd FSKW = 400 & 800% of test kVA

ls
See page 43 for Service Connections
Tr = Effective CT Ratio x effective VT Ratio
---r- Kh
------,
------,
I ClassI - � Style Numbers

j
Type Te Volts F u l l Scale kW Register
# Te r m i n a ls Amps a n d M u lt i p l i e r * Ratio

ua
4-Dial
Case Size
I _(_
15 M i nute 30 Mi nute
i
�-

t-
- Interval I nterval
-1 - _

D5B-34FM Switchboard Type -


1-
!
Transformer-Rated 20 2.5 1 20 3.6 7 . 2 / 1 4.4 x Tr 27 7;9 E4T1 1 1 A4AA E4T1 1 3A4AA
26-Te r m i n a l 20 2.5 240 7.2 - 1 4.4128.8 X Tr 13 8'9 E4T2 1 1 A4AA E4T21 3A4AA

_j_ j _ --

an
FT-32 Case
j__ _ ____l_ - ___]__ - -- - __

* For Primary Rated registers see Ordering Instructions on page 6. -

Shipping Weig hts (Appro x i m ate in Pounds) Case Dimensions: For refe rence o n l y
-- -- - ·-· ---r- -
Type ;- -
Carton --I_ --
Domestic
-
Expor t
- -1- -- -
_ ( I nches)
! ! D I
_ _ _

tM
__ __
__ _
Front View Side View
�g a l
Quant i ty 1 __ _

Net

tv1__j
Net hipping , G ross

D5B-3 F 4 1 -=- � .
21 _j_ 23
_
_L:i 1 _
l...3_ = j
3 37 � 1+---- 6 -3 8 -to

Shipping Carton Dimensions ( I---


--- - -,--- --- -----r n ches)
3-3; 1 6 3-3 ' 1 6

1.
- --------,--- · -· -
- -,----

j-
I
Type Carton Length Width . Height
I
ar
IT �� -
_j_
_l_
Qua nt1ty
-- _
D5 i34F M__r---- ---=-
-
1 -__j__ 21 _
12 =� � i/2
- - 1
lP

6-1;2 -r- 1-
ca

8- 1 , 4
tri

For P a n e l C u t o u t D i m ensions a n d
Ter m i n a l a n d M o u nt i n g H a rdware,
see page 42.
lec
.E
w
ww

October, 1988
om
Catalog
42-100C

Page 49

DSB-3 1 FM Single-Phase Totalizing Switchboard Watthour Demand Meters

.c
Mark l i la Register Product Code 48 3 3
3-Stator for Tota lizing 3-Circuits of 1 -Phase 2-Wire
M a r k l i l a Clock-Dial Mechanical Demand Register
Transformer-Rated Registers Class 8, Sta n d a rd FSKW = 800% of test kVA

See page 35 for Service Connections

ls
I I I
Tr = Effective CT Ratio x effective VT Ratio
Type Class Test Volts Kh F u l l Scale kW Register Style Numbers
# Te r m i n a ls Amps and M u ltipl ier* Ratio
4-Dial
Case Size

ua
i
i 15 M i n ute 30 M i n ute
-
---- - I nterval Interval

05B-31FM Switchboard Type

i
Transformer-Rated 20 2.5 1 20 1 .8 7 . 2 x Tr 55 5/9 EAL1 3 1 A4AA EAL1 33A4AA
20-Te r m i n a l 20 2.5 240 3.6 1 4.4 x Tr 27 719 EAL231 A4AA EAL233A4AA
FT-32 Case

an
* For Primary Rated registers see Ordering Instructions on page 6.

Shipping Weights (Approxim ate i n Pounds) Case Dimensions: For refe rence o n l y

I Domesti c ______--1-----'--,--- -------


-------,- ( I nches)
---- L ��
Type Carton
__ Front View Side View
Quantity

_____j_____1JJ_ .LI--

tM
S h r p pmg Gross

D5B-21_�ty1 1 2 1----- -- -- 3 5 --
f.--- 6-318 ----.
�--
_ --j___ ___j--
_
_1_____
3-3/1 6

IT ��--
ar
'
lP

6-1/2 -r-- -

'

8- 1 14
ca
tri

For Panel Cutout D i m e nsions a n d


Term i n a l a n d M o u n t i n g Ha rdware,
see page 34.
lec
.E
w
ww

October, 1 988
om
Catalog
42-100C

Page 50

D5B-32FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark l ila Regi ster Product Code 4834
4-Stator for Totalizing 2-Circuits of 3-Phase 4-Wire or 4-Circuits of 1 -Phase 2-Wire
M a r k I l i a Clock- D i a l Mechanical Demand Register
Transformer-Rated Registers Cl ass 8, Sta n d a rd FSKW = 800% of test kVA

See page 37 for Service Connections

ls
I
Tr = Effective CT Ratio x effective VT Ratio

I
Type Class Test Volts Kh Full Scale kW Reg i ster Style Numbers

--- --
# Term i n a ls Amps and M u ltiplier* Ratio

I
4-D i a l

ua
Case Size
1 5 M i n ute
Interval
I
r----
30 M i n ute
Interval

I
---

D5B-32FM Switchboard Type


Transformer-Rated
20-Term i n a l
20
20
2.5
2.5
1 20
240
2.4
4.8
9.6 x Tr
1 9. 2 x Tr
41 2/3
20 5/6
E 2 M 1 8 1 A4AX
E 2 M 2 3 1 A4AA
I E 2 M 1 8 3A4AX
E 2 M 233A4AA
FT-32 Case
I

an
* For Primary Rated registers see Ordering Instructions on page 6.

Case Dimensions: For reference o n l y


( I nches)
Type Domestic
Front View Side View

+---------�----�--����----���-+------

tM
S h i pp i n g Net Gross

1 9__....__
.L_ __
- -------
-6·318--
D5B-32FM 21 --�- 35

3-3/16
Shipping Carton Dimensions ( I nches)

i :
I
Type Carton Length Width Height
Qua ntity
ar
D5B-32FM
I 1 21 12
I 1 2 1/2

��-I -
8 - 1 /4
lP

6-1/2 - i- -

8 - 1 /4
ca

- r-

I
tri

For Panel Cutout D i m ensions a n d


Term i n a l a n d M o u nting H a rdware,
see page 36.
lec
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 5 1

D5B-38FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark lila Register Product Code 48 34
4-Stator for Totalizing 2-Circu its o f 3-Phase 4-Wire Wye
Mark l i l a Clock- D i a l Mech a n i ca l D e m a n d Register
Transformer-Rated Reg isters Cl ass 8, Sta n d a rd FSKW = 800% of test kVA

72 volt meters a re for use on 69.2/1 20V c i rcu its.

ls
1 20 volt meters are for u se on 1 20/208V ci rcuits.
240 volt meters a re for use on 2 65/460V o r 277/480V c i rcu its.
See page 39 for Service Connections

I !
Tr = Effective CT Ratio x effective VT Ratio

ua
I I
Type Class Test Volts Kh l Full Scale kW Register Style Numbers
# Terminals Amps and Mu ltiplier• Ratio 4-Dial
Case Size

I I
30 Min u te
I
15 Minute

I T I
I nterval I nterval

I
D5B-38FM Switchboard Type 20 2.5 72 2. 1 6 8. 64 x Tr 46 8/27 E8P731A4AA E8P733A4AA

I I

an
Transformer-Rated 20 2.5 120 3.6 1 4.4 X Tr 27 7/9 E8P 1 3 1 A4AA E8P1 33A4AA

I
I

I
20-Terminal 20 2. 5 240 7.2 28.8 x Tr 1 3 8/9 E8P231 A4AA E8P233A4AA
FT-32 Case I
* For Primary Rated registers see Ordering I nstructions on page 6.

tM
Case Dimensions: For reference o n l y
( I nches)
Front View Side View

f4---"- 6·3/8 -
3-3/16 3-3/16
ar
_j
Shipping Carton Dimensions ( I nches)
Type Length Width Height
I, g���t�ty
--+

IT �-� --
-c 1 �----· �--2_1
.

-
D5B-3s FM ---- �
'-- 13__ _ 1 2 1 /2
lP

6-1/2 l-- r-
ca

'

8-1/4
tri

For Panel Cutout D i mensions a n d


lec

Term i n a l a n d M o u n t i n g H a rdware,
see page 38.
.E
w
ww

October, 1988
om
Catalog
42-100C
Page 52

D5B-33FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark lila Register Product Code 48 34
6-Stator for Totalizing 2-Circuits o f 3-Phase 4-Wire Wye
M a rk l i l a Clock- D i a l M e c h a n i c a l D e m a n d Register
Transformer-Rated Registers Cl ass 8, Sta n d a rd FSKW = 800% of test kVA

72 volt meters a re for use on 69.2/1 20V circuits.

ls
1 20 volt meters a re for use on 1 20/208V c i rcu its.
240 volt meters are for use on 265/460V or 277/480V c i rcuits.
See page 41 for Service Connections
Tr = Effective CT Ratio x effective VT Ratio

ua
Style Numbers

I
Type Class Test Volts Kh F u l l Scale kW Regi ster
# Te r m i n a ls Amps a n d M u lt i p l ier* Ratio
4-Dial
Case Size
1 5 M i nute 30 M i n ute
I nterval Interval

I I I I I
05B-33FM Switchboard Type 20 2.5 72 2.16 8.64 X Tr 46 8/27 E3R731 A4AA E3R733A4AA

an
Transformer-Rated 20 2.5 1 20 3.6 1 4.4 x Tr 27 7/9 E3R 1 3 1 A4AA E 3 R 1 33A4AA
20-Te r m i n a l 20 2.5 240 7.2 28.8 x Tr 13 8/9 E3R231 A4AA E3R233A4AA
FT-32 Case

* For Primary Rated reg i sters see Ordering Instructions on page 6.

tM
Shipping Weights (Approximate i n Pounds) Case Dimensions: For reference o n l y

JL721/32j
( I nches)
Front View Side View

D5B·33FM 37 -6-3/8--

.. , I t··.. I
ar
3-3/16 3-3; 1 6
Shipping Carton Dimensions ( I nches)
Type C a rton Length Height

IT �-� --
.
Quantity

D5B-33FM 21 12 1 /2
lP

6-1/2 -r- f-

/
ca

'

8-1 4
tri

For Panel Cutout Di mensions a n d


lec

Ter m i n a l a n d M o u nting Ha rdware,


see page 40.
.E
w
ww

October, 1 988
om
Catalog
42-100C

Page 53

DSB-34FM Polyphase Totalizing Switchboard Watthour Demand Meters

.c
Mark lila Register Product Code 48 34
6-Stator for Totalizing 3-Circu its o f 3-Phase 3-Wire Delta
or for Totalizing 6-Circuits of 1 -Phase 2-Wire
M a rk l i la Clock- D i a l Mech a n ical D e m a n d Register
Transformer-Rated Registers C l ass 8, Sta n d a rd FSKW = 800% of test kVA

ls
See page 43 for Service Connections
Tr = Effective CT Ratio x effective VT Ratio
- -, - -Class ��-T� �V� ---,- �-!Full S cale kW
I
Ty pe Reg ister
---- ----- --- - --
Style Numbers
#Terminals Amps . . and Mult iplier* Ratio

I� --------t
4 - D ial
-- -------------

ua
Case Size I1 I

, I 15 M inute
Interval
30 M inute
Interval
---+-
D5B-34FM S�itchboard Typ ;;-1 I --+
I

I I
-- ----

Transformer - Rated 20 2.5 120 3.6 14.4 x Tr 27 7/9 E4T131A4AA E4 T133A4AA


26- Terminal 20 2.5 240 72 'I 28.8 x Tr 13 8 /9 E4T231A4AA E4 T233A4AA

an
F"::_32 Case___ __
_ re g isters see Ordering
* For Primary Rated InstructionsonL_
page 6. ____1 __________
---- --- ---
_____t_ ____ ____

Shipping Weights (Approxi m ate in Pounds) Case Dimensions: For reference o n l y

6-3/8 JL721 1321


Type
1------1--
( I nches)

tM
---'-,---,- Side View
Gross Front View

3-3/16 3-3116
37 1---- _____.,

Shipping Carton Dimensions ( I n ches)


Type
I Carton -,! _
1
--,
Le_n_gt- h------- i d-
W--� th�- - �
_
---H-e-i g_ht
. .., I ['"" I
ar
__

Quantity
o58-34FM ·=t

IT �-�--
-- _
1 21-
-'-----+----- I
12 - 12 1 12
I

6-1/2 -
lP

1-- -

8-1/4
.
ca

1/4
tri

For P a n e l Cutout D i men si o n s a n d


Term i n a l a n d M o u nt i n g H a rdware,
lec

see page 42.


.E
w
ww

October, 1988
Catalog

Page 54
42-100C
ww
w
.E
lec
tri
ca
lP
ar
tM
an
ua
ls
.c
om
ww
w
.E
lec
tri
ca
lP
ar
tM
an
ua
ls
.c
Catalog
42-100C

Page 55

om
om
Catalog
42-100C

Page 56

.c
ls
ua
an
tM
ar
lP
ca
tri
lec
.E
w

West i n g ho u se E lectric Corporation


Measu re m e nts and Control Division
Raleigh, North Caro l i na, U . S .A. 2761 1 -9533
ww

Printed in U.S.A.

October, 1 988

You might also like