You are on page 1of 3

Vibration Analysis Report V.

00 Engineering Department
DRI- Utility WTTP Diagnosis Section
Asset: Product Pump P428 B Issue Date: 21 February 2023

Equipment Overall (mm/sec) Equipment speed Status Diagnosis Recommendations


-The motor peakvue spectrum shows significant 1- Change motor bearings as highly
change dominant non-synchronous peak with suspect in bad lubricant and
multiples at 6.3 TS (158.4 Hz) which matched BPFI bearing defect.
inner race frequency of bearing defect specially at 2- Check and record axial play of
drive side and time waveform has relatively high G’s motor shaft before any action.
Max Vibration
PK-Pk value. 3- Check pump internal
reading 1.5 mm/s
Motor-Pump 1480 rpm - The motor TWF has impacts with high crest factor components and suction line.
(Motor Drive side
CF=4.8.
-Axial)
- Random peaks may be transmitted from pump.
- pump does not have point of measures as it is direct
coupled with motor without roller bearings.

1 Emergency Situation 2 Work to be done ASAP 3 Problem developing, Following up 4 Normal

Abbreviated Last Measurement Summary


************************************

Database: Ezz DRP-2022.rbm


Area: DRP W.TREATMENT & Clarifier AREA
Report Date: 01-Mar-23 13:27

MEASUREMENT POINT OVERALL LEVEL


----------------- -------------

P-428B - Product pump P-428B (21-Feb-23)


OVERALL LEVEL
M1H - Motor Outboard Horizontal 1.104 mm/Sec
M1P - Motor Outboard Horz Peakvue .379 G-s
M1V - Motor Outboard Vertical 1.192 mm/Sec
M1A - Motor Outboard Axial .985 mm/Sec
M2H - Motor Inboard Horizontal .964 mm/Sec
M2P - Motor Inboard Horz Peakvue .707 G-s
M2V - Motor Inboard Vertical 1.173 mm/Sec
M2A - Motor Inboard Axial 1.557 mm/Sec

-------------------------------------------------------------------------------
Clarification Of Vibration Units:
Acc --> G-s Vel --> mm/Sec RMS