Abstract: - One of the many ways of reducing the energy consumption for non-residential buildings is to adopt
the closer solution with double skin facade. The low energy consumption methods for buildings are:
- during cold weather times, the limitation of heat losses by increasing the thermal insulation of building
envelope and the increase of inside heating flux through positive thermal solar inputs;
- during hot weather times, reducing the energy consumption for cooling process through recovering the
renewable coldness during the nights (night cooling);
- during transition periods, the decrease of energy consumption for cooling process through extension of
time periods for natural ventilation;
- during the whole year, by extending of the natural lighting.
Key-Words: - double skin facade, thermal transmission factor, thermal solar input, energy
ISBN: 978-1-61804-165-4 93
Recent Advances in Engineering Mechanics, Structures and Urban Planning
2.3 The energy consumption for artificial 3.2 The warming, cooling and neutral
lighting periods of time
As it can be noticed from the next chart:
The energy consumption for the artificial
- 54% of the year represents the period when the
lighting has a small part of the total energy interior warming of the buildings is needed;
consumption of buildings from Romania. - 10% of the year represents the period when the
Nevertheless, in case of non-residential interior cooling of the buildings is needed;
buildings, in more situations an important - 36% of the year represents the neutral period
amount of energy is consumed even for from the exterior temperatures point of view, when
lighting. neither heating nor cooling is necessary.
ISBN: 978-1-61804-165-4 94
Recent Advances in Engineering Mechanics, Structures and Urban Planning
ISBN: 978-1-61804-165-4 95
Recent Advances in Engineering Mechanics, Structures and Urban Planning
4.2 The double skin façade behaviour In addition, this paper wants to draw attention of
during hot weather time Romanian specialists on the opportunity of adopting
The bellow chart shows the temperature fluctuation the cooling solution by using both the natural
regarding a common double facade for the exterior ventilation and night cooling as much as possible.
climate in Bucharest, during a period of 72 hours As it was already mentioned, this approach is
(20th -23th of July). During hot period, the solar assuming a new path in designing, which is quite
protection devices assembled in the double facade difficult task in Romania where these projects are
cavity work automatically, dependent on the sun realized in small workgroups.
positioning, reducing significantly the solar input. Also, it would be a great idea to implement the
They can so reduced up to 90%. The exterior air coaching of future specialists by using the
temperature is (between +22°C and+38°C) during simulation of building behaviour in dynamic
the analyzed period. thermal condition.
In the same idea, it should be mentioned that
even Romanian legislation is presuming the
reducing of the energy consumption for buildings,
the owners of non-residential buildings (of present
and future buildings) are not concerned of these
amendments.
References:
[1] Saelens, D., Carmeliet, J., Energy performance
assessment of multiple skin facades,
Fig.7. Temperature flow in south façade for hot International Journal of HVAC&R, USA, 2003.
days in summer in Bucharest. [6] [2] Arons, D., Properties and Applications of
Double-Skin Building Facades, Massachusetts
From the diagram it can be understood that even Institute of Technology (MIT), USA, 2004.
the temperature of exterior glass has much higher [3] Poirazis, H., Double Skin Façades for Office
values (between +22°C and +42°C), the Buildings, Lund University, Lund Institute of
temperature of interior glass has much lower values Technology, 2004, ISBN 91-85147-02-8.
(between +22 oC and +26 oC). [4] Vijaya, Y. A., Evaluation and Design of
In the same time, the chart shows higher values Double Skin Facades in Hot Climates, Thesis a
of the air behind the solar protection system. Texas A&M University, May 2004.
Therefore, to achieve the natural ventilation of [5] Pollet, I., Renson Ventilation for ventilation
the building through internal cavity of the facade, it and solar shading, RENSON VENTILATION
is necessary to extract the excess heat from this NV, Waregem- Belgium, 2009.
cavity. This can be achieved through an adequate [6] Winfried Heusler - Facade technology – theory
mechanical ventilation of the facade cavity. and specific project, PPT_Vorlage_01.pot -
SCHUECO Engineering, 2009.
5 Conclusions
The double skin facade solution is one of the most
recent closer solutions of the buildings, which can
provide a decrease up to 40-50% of energy
consumption during of exploitation and activity of
non residential buildings [2]. In the Romanian
climate features, the main disadvantage of this
solution is the overheating of the interior air of the
double skin facade during summer. Certainly, the
disposal of the heating assumes energy consumption
with the ventilation of the double skin facade cavity,
fact that decreases the global performances of this
solution from the energy consumption point of view.