You are on page 1of 5

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/276145716

Double Skin Facade -a Solution for Reducing Energy Consumption of Residential


Buildings in Romania

Conference Paper · February 2013


DOI: 10.13140/RG.2.1.1454.2245

CITATIONS READS
0 225

5 authors, including:

Mircea Horneł Dorin Cristian Năstac


Universitatea Transilvania Brasov Universitatea Transilvania Brasov
16 PUBLICATIONS   11 CITATIONS    14 PUBLICATIONS   14 CITATIONS   

SEE PROFILE SEE PROFILE

Ungureanu Valentin-Vasile Adam Dosa

23 PUBLICATIONS   16 CITATIONS   
Universitatea Transilvania Brasov
17 PUBLICATIONS   6 CITATIONS   
SEE PROFILE
SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Mechanical Engineering View project

Stability of Structures View project

All content following this page was uploaded by Ungureanu Valentin-Vasile on 12 May 2015.

The user has requested enhancement of the downloaded file.


Recent Advances in Engineering Mechanics, Structures and Urban Planning

Double Skin Facade - a Solution for Reducing Energy Consumption of


Residential Buildings in Romania
MIRCEA HORNEŢ1), IOAN LUCIAN CÎRSTOLOVEAN1), DORIN CRISTIAN NĂSTAC1)
VALENTIN-VASILE UNGUREANU2), ADAM DÓSA2)
1)
Buildings Services Department
Transilvania University of Braşov
5th Turnului Street, Brasov
ROMANIA
mircea.hornet@unitbv.ro, luceoe@yahoo.com, nastaccristi@unitbv.ro
http://www.unitbv.ro/constructii/en
2)
Civil Engineering Department
Transilvania University of Braşov
5th Turnului Street, Brasov
ROMANIA
vvungureanu@unitbv.ro, adamdosa@yahoo.com http://www.unitbv.ro/constructii/en

Abstract: - One of the many ways of reducing the energy consumption for non-residential buildings is to adopt
the closer solution with double skin facade. The low energy consumption methods for buildings are:
- during cold weather times, the limitation of heat losses by increasing the thermal insulation of building
envelope and the increase of inside heating flux through positive thermal solar inputs;
- during hot weather times, reducing the energy consumption for cooling process through recovering the
renewable coldness during the nights (night cooling);
- during transition periods, the decrease of energy consumption for cooling process through extension of
time periods for natural ventilation;
- during the whole year, by extending of the natural lighting.

Key-Words: - double skin facade, thermal transmission factor, thermal solar input, energy

1 Introduction groups involved: architects, structural


In addition of measures regarding the decrease of engineers, plumbing engineers, there are also a
primary energy consumption necessary for thermal lot of simulation activity in dynamic thermal
energy production are required also the solutions conditions of building and then the cycle is
that provide low energy consumption for heating reengaged till the best solutions are adopted [5].
and cooling interior building spaces. The decrease Unfortunately, in Romania the things are not
of energy consumption for all types of buildings is a going in the same direction. Usually, the
challenge present all over the world. plumbing engineers receive the final solutions
Generally, the adopted cooling solutions in of architecture and building resistance, which
Romania are using the artificial cooling, which makes practically impossible to adopt an
implies important energy consumption. In the optimal solution regarding the natural
last 20 years, especially in Western Europe, ventilation and night cooling process. This
there are implemented more and more cooling article presents the following issues:
solutions based on natural ventilation and night - The main energy consumption methods of
cooling [3]. To succeed such a deployment, a building;
there is necessary an adequate architectural - The Romanian climate features;
approach, in order to allow this actions. In this - The double skin facade behaviour during
regard, the project management is preceded by both cold and hot weather.
an important and necessary period of ”planning”
operation, during which the proposals are made,
there is a certain analyzing activity by all the

ISBN: 978-1-61804-165-4 93
Recent Advances in Engineering Mechanics, Structures and Urban Planning

2 The energy consumption forms of a 3 The Romanian climate features


building
3.1 Average outdoor temperature and
2.1 The energy consumption needed for rainfall
heating during cold weather The Romanian climate is European moderate
The conduction and convection heating transfer climate, with gentle summers and cold winters. In
represent the forms of the thermal transfer through the below charts is presented the average outdoor
which the buildings lose the most of the heat temperature and rainfall, and the outdoor
quantity towards exterior environment during the temperature and heating days per year for Bucharest
cold weather time. As it is well known, this thermal city. In summary, the important meteorological data
transfer takes place because of the difference of are as follows:
temperature between the interior and exterior - mean annual temperature: +11.2°C;
environment and it is measured with the thermal - decennial temperature minimum: -14.3°C;
transmittance factor (U value), which indicates the - decennial temperature maximum: +34.9°C.
heat flux unit (W/m2) through the building envelope
for one degree difference of temperature between
the interior and exterior [4].
For the Romanian climate features, the
conduction and convection heating transfer bring
significant increase to the building energy
consumption during the whole year, but especially
during cold weather time. The decrease of heating
loss of a building is obtained by optimizing the
envelope thermal insulation.

Fig.1 Average outdoor temperature and rainfall


2.2 The energy consumption for cooling
in Bucharest. [6]
during hot weather
The direct and indirect solar radiation is the one
which favours the heat penetration inside
buildings through the buildings envelope, and
especially through the window pane surfaces,
during the hot weather times [1]. Obviously, it
is necessary to consume a considerable amount
of energy for interior space cooling to insure the
optimal comfort parameters inside the building.
In Romania, the solar flux input through a
triple glazing window over the summer period
is about 6.5 MJ/m², per day for south/west Fig.2. Outdoor temperature and heating days
orientation, respectively 5.5 MJ/m², per day for per year in Bucharest. [6] (Heating days in
east orientation. dependence to heating start temperature)

2.3 The energy consumption for artificial 3.2 The warming, cooling and neutral
lighting periods of time
As it can be noticed from the next chart:
The energy consumption for the artificial
- 54% of the year represents the period when the
lighting has a small part of the total energy interior warming of the buildings is needed;
consumption of buildings from Romania. - 10% of the year represents the period when the
Nevertheless, in case of non-residential interior cooling of the buildings is needed;
buildings, in more situations an important - 36% of the year represents the neutral period
amount of energy is consumed even for from the exterior temperatures point of view, when
lighting. neither heating nor cooling is necessary.

ISBN: 978-1-61804-165-4 94
Recent Advances in Engineering Mechanics, Structures and Urban Planning

From the above chart results a high potential for


an automated night cooling. Especially the peak
cooling month July and August are ideal for the
night ventilation.

4 The double skin façade behaviour


4.1 The double skin façade behaviour
Fig.3. The warming, cooling and neutral during cold weather time
periods of time in Bucharest. [6] The bellow chart shows the temperature variation
associated with a double skin facade, for the exterior
Because of the extension of colder weather period, climate of Bucharest city, during a period of 72
the energy consumption for interior building heating hours, when the minimum annual temperature is
represents an average of 70% of the annual energy recorded. During this period of year, the cavity of
consumption of a building. double skin facade is working, most of the time, on
the „closed” position, which makes the air from
interior to have an important thermal insulation
3.3 The potential of climate regarding the
function. The solar protection devices installed in
natural ventilation and night cooling the double skin facade cavity are functioning during
process cold weather time on "open" position, speeding up
the heat penetration from solar radiation.

Fig.4.Window ventilation in dependence of


outdoor temperature and relative humidity in
Bucharest.[6]
Fig.6. Temperature flow in south façade, cold
By analyzing of the chart, it is obvious that the days in winter in Bucharest. [6]
natural ventilation could be over:
- 930 [h] per year (11%) - in good comfort zone; The chart clearly shows the measure of contribution
- 2100 [h] per year (24%) - in moderate comfort from the double skin facade to the decrease of
zone. building heating losses. The exterior air
temperature, during the analysis period, fluctuates
between -15°C and +3°C. From the chart analysis it
can be observed that even the temperature of
exterior glass of double skin facade has low values
(between -15°C and +12 °C), the temperature of
interior glass of double skin facade has much higher
and constant values (between +17°C and +24 °C).
Hereby, the conduction and convection heating
transfer is significantly reduced, which leads to an
important decrease of heating losses through the
Fig.5. Cooling potentials of a free night building envelope. In addition, through the window
ventilation in Bucharest. [6] (Approximated pane of double skin facade it can be obtained an
night ventilation hours per month due to important solar radiation flux input.
outdoor temperature)

ISBN: 978-1-61804-165-4 95
Recent Advances in Engineering Mechanics, Structures and Urban Planning

4.2 The double skin façade behaviour In addition, this paper wants to draw attention of
during hot weather time Romanian specialists on the opportunity of adopting
The bellow chart shows the temperature fluctuation the cooling solution by using both the natural
regarding a common double facade for the exterior ventilation and night cooling as much as possible.
climate in Bucharest, during a period of 72 hours As it was already mentioned, this approach is
(20th -23th of July). During hot period, the solar assuming a new path in designing, which is quite
protection devices assembled in the double facade difficult task in Romania where these projects are
cavity work automatically, dependent on the sun realized in small workgroups.
positioning, reducing significantly the solar input. Also, it would be a great idea to implement the
They can so reduced up to 90%. The exterior air coaching of future specialists by using the
temperature is (between +22°C and+38°C) during simulation of building behaviour in dynamic
the analyzed period. thermal condition.
In the same idea, it should be mentioned that
even Romanian legislation is presuming the
reducing of the energy consumption for buildings,
the owners of non-residential buildings (of present
and future buildings) are not concerned of these
amendments.

References:
[1] Saelens, D., Carmeliet, J., Energy performance
assessment of multiple skin facades,
Fig.7. Temperature flow in south façade for hot International Journal of HVAC&R, USA, 2003.
days in summer in Bucharest. [6] [2] Arons, D., Properties and Applications of
Double-Skin Building Facades, Massachusetts
From the diagram it can be understood that even Institute of Technology (MIT), USA, 2004.
the temperature of exterior glass has much higher [3] Poirazis, H., Double Skin Façades for Office
values (between +22°C and +42°C), the Buildings, Lund University, Lund Institute of
temperature of interior glass has much lower values Technology, 2004, ISBN 91-85147-02-8.
(between +22 oC and +26 oC). [4] Vijaya, Y. A., Evaluation and Design of
In the same time, the chart shows higher values Double Skin Facades in Hot Climates, Thesis a
of the air behind the solar protection system. Texas A&M University, May 2004.
Therefore, to achieve the natural ventilation of [5] Pollet, I., Renson Ventilation for ventilation
the building through internal cavity of the facade, it and solar shading, RENSON VENTILATION
is necessary to extract the excess heat from this NV, Waregem- Belgium, 2009.
cavity. This can be achieved through an adequate [6] Winfried Heusler - Facade technology – theory
mechanical ventilation of the facade cavity. and specific project, PPT_Vorlage_01.pot -
SCHUECO Engineering, 2009.

5 Conclusions
The double skin facade solution is one of the most
recent closer solutions of the buildings, which can
provide a decrease up to 40-50% of energy
consumption during of exploitation and activity of
non residential buildings [2]. In the Romanian
climate features, the main disadvantage of this
solution is the overheating of the interior air of the
double skin facade during summer. Certainly, the
disposal of the heating assumes energy consumption
with the ventilation of the double skin facade cavity,
fact that decreases the global performances of this
solution from the energy consumption point of view.

ISBN: 978-1-61804-165-4 96

View publication stats