SINGLE / THREE PHASE OVER / UNDER VOLTAGE MONITORING DEVICES

GKR / DGR / GKRC / DGRC SERIES


General Utilization with Single-Phase and Two-Phase Systems
GKR ve DGR series ‘‘over and under voltage’’ monitoring devices
are adjustable ‘‘delay OFF’’ protection devices.They are mainly used for (For only GKR-01/02, GKRC-01/02, DGR-01, DGRC-01)
protection of 3-phase and single-phase systems - such as electronic See following connection diagrams for both cases:
command and control systems,capacitors of power compensation,
switch-boards,air-condition systems, motors etc. N L1 L2 L3 N L1 L2 L3
L1 L1
Utilization and Operation Principles L2 N
For all relays N
Two Phase Connection Diagram Single Phase Connection Diagram
“On” is the supply led
“Out” is normal led
“U>” is over voltage error led Connection Diagram
a)
“U<” is under voltage error led b)
1-When the device is energized for the first time , “On” led is ON and if the
monitored voltages are within the adjusted range “Out” led is ON and
3 2 1 3 2 1
output relay switches ON. GKR GKR
2-When any of the phase/phases fall(s) below the adjusted interval, ‘‘U<’’
1.25 1.30 1.25 1.30
3 3
1.20 2 On 1.20 2 On
xUn 1 xUn 1

error led turns ON, after 0.1-10 sec, output relay switches OFF and “Out”
1.15 Out 1.15 Out
1.10 1.05 1.10 1.05
U> U>

led turns OFF.


0.90 0.95 8 10 U< 0.90 0.95 8 10 U<
0.85 0.85
xUn 4 t (sn.) xUn 4 t (sn.)

3-When any of the phase/phases exceed(s) the adjusted interval, ‘‘U>”


0.80 0.80
2 0.1
0.75 0.70 0.75 0.70 2 0.1

error led turns ON, after 0.1-10 sec output relay switches OFF and “Out” N L1 L2 L3 N L1
led turns OFF. N
L1
N
L1
Look at table 1
L2 N System

* For under voltage monitoring, device switches OFF its output relay L3
instantaneously when the measured voltage(s) fall(s) below %50 of its System
N
nominal value.
For over voltage monitoring, device switches OFF its output relay immediately c) d) e)
when the measured voltage(s) exceeds %50 of its nominal value. 1 2 3 1 2 3 1 2 3

GKR-02F / GKRC-02F / GKRC-02FA / GKR-03F / GKRC-03F / switches 1.20


1.25 1.30 GKRC
3 1.20
1.25 1.30 GKRC
3
1.20
1.25 1.30

xUn
GKRC
2
3

off output relay instantaneously in case of incorrect phase sequence then


xUn 2 xUn 2 1
1 1 1.15
1.15 1.15
1.10 1.05
1.10 1.05 1.10 1.05
U> On Out
U> U< On Out U> U< On Out

all leds turn off except “ON” led. 0.85

0.80
0.90 0.95

xUn 4
8 10

t (sn.)
0.85

0.80
0.90 0.95

xUn 4
8 10

t (sn.)
4
8 10

t (sn.)

2 0.1

*Please notice the right side for connection diagram and dimensions.
2 0.1 2 0.1
0.75 0.70 0.75 0.70

Technical Data N L1 L2 L3 L1 L2 L3 N L1 L2 L3
N N N
L1 L1 L1

Rated Voltage (Vin) : Look at the label of the device L2 L2 L2

Rated Frequency : 50/60 Hz L3


System
L3
System
L3
System
Auxiliary Supply Voltage :190-260 V AC (for only GKRC-02FA) N N

Voltage Adjustment (L-L) : Umax : 400 - 500 V AC (for only GKRC-02FA) h)


g)
Umin : 300 - 400 V AC (for only GKRC-02FA) f)
1 2 3 1 2 3 A1 1 2 3
Umax: (1,05 - 1,30) x Vin (for others) GKRC-02FA
Umin : (0,70 - 0,95) x Vin (for others) 1.25 1.30 DGRC
GKRC 460
480 500
2

Delay Time : 0.1 - 10sn. min.(adjustable)


1.20 3 1.25 1.30 (V)
xUn 2
1 1.20 440 1 3
1.15 3
xUn 2 420 400
1.10 1.05
1.15 1 ON OUT

Output Contact : 1C/O, 8A, 2000 VA,cosj=1


U< On Out
1.10 1.05 U> U<

10 U> U< On Out 380 8


8 400 10
360 6

Set Point Hysteresis : %3


4 t (sn.) (V) t(s)
0.90 0.95 8 10
340 4
2 0.1 0.85
xUn 4 t (sn.) 320 300 2 0.1

Ambient Temperature : - 5°C ; + 50°C


0.80
2 0.1
0.75 0.70

Installation :Surface mounted or rail-mounted N L1 L2 L3 A2 L1 L2 L3

Dimensions : Type PK10 / PK21 / PK25 L1


N
N L
Un
A1
A2
Protection Class : IP 20 L2
L
N
N

Weight : 0,3 kg (Type PK21 / PK25) L3


System N L1
N System Vin (L-L)
L2
PRECAUTIONS FOR INSTALLATION AND SAFE USE L3 System

Failure to follow those instructions will result in death or serious injury. Function Table Table-2
Disconnect all power before working on equipment. Protection Function
When the device is connected to the network, do not remove the front panel. TYPE High voltage Low voltage
3 phases
4 wires
star
3 phases
3 wires
delta
1 phases
2 wires
Dimension Connection

Do not try to clean the device with solvent or the like. Only clean the device
DGR-01 PK-21 a
with a dried cloth.
DGR-M1 PK-21 b
Verify correct terminal connections when wiring.
GKR-01 PK-21 a
Electrical equipment should be serviced only by your compedent seller.
GKR-M1 PK-21 b
No responsibility is assured by the manufacturer or any of its subsidiaries for
GKR-02 PK-21 a
any consequences arising out of the use of this material.
GKR-02F PK-21 a
Only for rack panel mounting.
GKR-M2 PK-21 b
Condition of leds GKRC-02 PK-25 c
GKRC-02F PK-25 c
On Out U> U< GKRC-02FA PK-25 h

Voltage(s) is/are within adjusted limits GKRC-03 PK-25 d


GKRC-03F PK-25 d
Both low and high voltage GKRC-01 PK-25 e
Temporary low voltage DGRC-01 PK-25 f
GKRC-M2 PK-25 g
Continuous low voltage
Temporary high voltage Dimensions 58 mm

Continuous high voltage


14

Table-1
:LED is ON :LED is OFF
90 mm

TiP PK25
35 mm

45 mm
62 mm

TiP PK21
80

Auxiliary Supply Connection Diagram (For only GKRC-02FA)

A1 A2 L1 L2 L3
44 35
A1 32 mm
A2 80 35 mm

L1 48 mm
L2
L3

A2897 / Rev.4