www.ijisrt.com
International Journal of Innovative Science and Research Technology
B. Methodology
This research is an experimental study which was
tested qualitatively. The research sample (lung CT-
Table1. Average Contouring Accuracy Score
Simulator images from lung cancer patients) applied
three types of segmentation (automatic segmentation, Otomatis Semi- Combinatio
semi-automatic segmentation and a combination of Otomatis n
automatic, semi-automatic, and manual segmentation). Tumor 72,22 73,33 97,78
The three types of segmentation were compared for their Target
accuracy values rated by radiation oncologists. Radiation Heart 73,33 66,67 93,33
oncologists rated of accuracy on a predetermined scale. Esophagus 34,44 96,67 97,78
After assessing the accuracy of contouring, the data is Spinal Cord 36,67 95,56 97,78
then processed with SPSS. Right Lung 97,5 66,25 98,75
The contouring accuracy data for the three types of Left Lung 98,82 72,94 98,82
segmentation are averaged. In addition, the data was
calculated using a non-parametric test. Kruskal-Wallis Table 2. Kruskal-Wallis Test Results
test followed by Tamhane's post hoc analysis.
Variable p-value
III. RESULT AND DISCUSSION Otomatis
In this study the experiment was conducted using Tumor Target Semi-Otomatis 0,000
MATLAB software on the image to be processed. Combination
Contouring is applying with three types of segmentation Otomatis
(automatic segmentation, semi-automatic segmentation Heart Semi-Otomatis 0,225
and a combination of automatic, semi-automatic, and Combination
manual segmentation). Automatic segmentation using the Otomatis
K-Nearest Neighbor method and thresholding. While the Esophagus Semi-Otomatis 0,000
semi-automatic segmentation uses the active contour Combination
method and the manual method of ROI in manual Otomatis
segmentation. The results of the study are shown in Spinal Cord Semi-Otomatis 0,000
figure 1. Combination
Otomatis
Right Lung Semi-Otomatis 0,000
Combination
Otomatis
Left Lung Semi-Otomatis 0,000
Combination
(a) (b)
Table 3. Mann-Whitney Test Results
Variable p-value
Tumor Target 0,673
Heart 0,700
Otomatis and Esophagus 0,000
Semi-Otomatis Spinal Cord 0,000
Right Lung 0,000
(c) (d) Left Lung 0,000
Figure 1. Original image (a), automatic segmentation (b), Tumor Target 0,001
semi-automatic segmentation (c), combination of Heart 0,400
automatic, semi-automatic and manual segmentation (d). Otomatis and Esophagus 0,000
Combination Spinal Cord 0,000
The contouring results obtained from the segmented Right Lung 0,780
image are then measured for accuracy by radiation Left Lung 1,000
oncologists on the tumor target and OAR which can be Semi-Otomatis Tumor Target 0,000
seen in table 1. While the results of the Kruskal-Wallis and Heart 0,100
test can be seen in table 2 and the results of Tamhane's Combination Esophagus 0,791
post hoc test can be seen in table 3.
Spinal Cord 0,584
www.ijisrt.com
International Journal of Innovative Science and Research Technology
Right Lung 0,000 and automation. With the balance between human
Left Lung 0,000 interaction and automation, it can minimize time, reduce
inter-observer variability, increase contour accuracy, and
can add or reduce contour areas according to the doctor's
From the results of the average grade of the accuracy wishes based on various considerations.
of the automatic segmentation contouring shows a low
grade in the esophagus and spinal cord. The tumor and
heart targets have not received a middle score. High REFERENCES
scores are only found in both right and left lungs. [1] A. Aselmaa, M. van Herk, Y. Song, R. H. M.
Goossens, and A. Laprie, “The influence of
In semi-automatic segmentation, the esophagus and
spinal cord high score. While the target values for tumor, automation on tumor contouring,” Cogn.
heart, right lung, and left lung still get middle scores. Technol. Work, vol. 19, no. 4, pp. 795–808, 2017,
doi: 10.1007/s10111-017-0436-0.
The combination of automatic, semi-automatic, and [2] K. J. Marcus, “Radiation therapy,” Encyclopædia
manual segmentation is an improvement from the Britannica. Encyclopædia Britannica, 2020,
mistakenness of automatic and semi-automatic [Online]. Available:
segmentation. This editing can enhanced provides high https://www.britannica.com/science/radiation-
value across contoured areas. While fully automated therapy.
tools still less efficiency, tools that balance human
[3] A. Sebaaly, C. Bassile, and T. Akl,
interaction and automation can be more effective[1].
“Radiotherapy Treatment Planning System
In this study, program development using fully Simulation Lung Cancer Application,” IEEE Int.
automatic and semi-automatic segmentation is still less Multidiscip. Conf. Eng. Technol. IMCET 2018,
effective because there are several factors such as gray pp. 1–6, 2019, doi:
level with parts that should not be contoured, causing the 10.1109/IMCET.2018.8603054.
program to detect organs that should be contoured. [4] A. T. Davis, A. L. Palmer, and A. Nisbet, “Can
However, the results of a contouring program that uses a CT scan protocols used for radiotherapy
combination of automatic, semi-automatic, and manual treatment planning be adjusted to optimize image
segmentation are very effective because of the balance quality and patient dose? A systematic review,”
between human interaction and automation. So users can
Br. J. Radiol., vol. 90, no. 1076, 2017, doi:
add and subtract contours based on other considerations,
10.1259/bjr.20160406.
not only based on the CT-Simulator image. The existence
of a process there makes the contour results accurate [5] F. Sterzing, R. Engenhart-Cabillic, M. Flentje,
according to the ICRU guidelines. and J. Debus, “Image-Guided Radiotherapy,”
Dtsch. Arztebl., vol. 108, no. 16, pp. 274–280,
From the results of the Kruskal-Wallis test were < 2011, doi: 10.3238/arztebl.2011.0274.
0.05 except for the heart, it was concluded that there was [6] J. Cacicedo, A. Navarro-Martin, S. Gonzalez-
at least a difference between the two groups. The next Larragan, B. De Bari, A. Salem, and M. Dahele,
test is post hoc using Mann-Whitney to find out between “Systematic review of educational interventions
groups that have differences[10]. The results of the to improve contouring in radiotherapy,”
Mann-Whitney test, it can be ascertained that there is no
Radiother. Oncol., vol. 144, pp. 86–92, 2019,
difference in the results according to contouring on
variables with p-vaue > 0.001. The variable with p-value doi: 10.1016/j.radonc.2019.11.004.
< 0.001 indicates a difference in the two groups. [7] B. A. . Silva, A. Fazenda, and F. Paixao,
“Femural Head Autosegmentation for 3D
IV. CONCLUTION Radiotherapy Planning: Preliminary Results,”
IEEE Trans. Med. Imaging, 2018.
Fully automatic segmentation with location [8] B. E. Nelms, W. A. Tomé, G. Robinson, and J.
classification methods and automatic gray level and fully
Wheeler, “Variations in the contouring of organs
semi-automatic segmentation with methods that use a
at risk: Test case from a patient with
closed curve model that widens or narrows at the same
degree of gray level in the CT-Simulator image of lung oropharyngeal cancer,” Int. J. Radiat. Oncol.
cancer cases has not obtained maximum results. The Biol. Phys., vol. 82, no. 1, pp. 368–378, 2012,
combination of automatic, semi-automatic, and manual doi: 10.1016/j.ijrobp.2010.10.019.
segmentation can increase the accuracy of contouring [9] K. Men, H. Geng, T. Biswas, Z. Liao, and Y.
because of the editing process to improve the contouring Xiao, “Automated Quality Assurance of OAR
results that are less than automatic or semi-automatic Contouring for Lung Cancer Based on
segmentation in lung cancer. Contouring programs are Segmentation With Deep Active Learning,”
more effective because they balance human interaction Front. Oncol., vol. 10, no. July, pp. 1–7, 2020,