You are on page 1of 1

NON-DESTRUCTIVE TESTING FACILITY

Solid Propellant Space Booster Plant


Satish Dhawan Space Centre - SHAR
DYE PENETRANT INSPECTION REPORT
Date: 19-07-2021

1. Job reference: Critical weld joints related to compressed air SS pipelines (of size 1/2
inch,1 inch, 1 1/2 inch & 2 inch) at VM-8 facility and interconnecting VM-4 to VM-8 facilities
(2 inch GI make), SPROB. (I\St4f)

2. Date of inspection: 15-07-2021 to 16-07-2021

3. Stage of inspection: After fabrication

4. DP Type: Solvent Removable

5. DP Procedure: As per ASTM-E-165

Observations:

No significant indications are noticed.

DP witnessed by
A. Nagoor Reddy

(Y. DEVA SUDHARSHAN) (B. KARTHIKEYAN)


Engineer, NDT-SPROB Dy. Manager, NDT-SPROB