Professional Documents
Culture Documents
TRIAL MIX FOR 300MM DIAMETER MICROPILE GROUT G35 GROUT MIX
The proportions of grout and the minimum strength of work cubes shall comply with the
following requirements:
GROUT MIX
The quantities of cement in the mix shall be measured by weight. The grout shall be free from
segregation, slumping and bleeding. Grout shall be mixed on site and shall be pumped into its
final position as soon as possible. Non-shrink admixture (SIKA Intraplast-Z ) shall be added at
approximately 1% by weight.
Example
G35 with
Water: cement ratio = 0.45
Cement =23 bags*50 = 1150kg
Water = 0.45*1150 = 517.5kg
Sika- Intraplast-z = 0.01*1150 = 11.5kg
Total Weight = 1155+517.5+11.5 = 1679kg
Volume = 1679kg/1700kg/cu.m
= 0.99 cu.m
Yours falthfully,
for BORNEO GEOTECHNICAL ENINEERING SDN BHD