You are on page 1of 6

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
RENR5445-01
June 2020

330C Excavator
Hydraulic System - Attachment
CYA1-UP
JAB1-UP
KDD1-UP
DKY1-UP

System 3: One Way / Two Pump Flow / Foot Switch

© 2020 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION

Schematic Machine
Component
Location Location
Valve Gp Solenoid (Pilot Control) E-7 1
Valve Gp Line Relief (Work Tool) E-5 2
Valve Gp Auxiliary C-6 3
Valve Gp Proportional Reducing Solenoid (Negative Flow Control) B-1 4
7 6 5 4 3 2 1
TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT)
(2) VALVE GP
LINE RELIEF (WORK TOOL)
177-2653
X X
(1) VALVE GP
SOLENOID (PILOT CONTROL) SINGLE SINGLE
T2 T2
121-6303
T1 T1
SWING MOTOR
E E

PR
D

BUCKET BOOM BOOM


STICK CYLINDER CYLINDER CYLINDER CYLINDER

TRAVEL(L) TRAVEL(R)

A B B A

AB

SWIVEL

D D

BP2 BPi
APi AP2
ADr BDr
BP3
AP3
BR5
DR3 aR2 AR2
AP1 AT aL3 BL2 AL2 BL1 aL1 PP3 PST aR1 BR1 AR1 BR2 aR3 BR3 AR3 aR4 Pi1 AR4 BT AR5 aR5 R3
BP1
(3) VALVE GP T AL4 aL4 BL3 R2 AL3 AL1 (CLOSE) (LOWER) BR4 R1
aL2
AUXILIARY (RAISE) (IN)
(REV)
(REV)
(L)
121-6303
FA FB Pa

(IN)

C C

BOOM(2) STICK (1) SWING


ATCH BUCKET BOOM(1) STICK(2) (4) VALVE GP
TRAVEL(L) TRAVEL(R)
F2 (OUT) (R) (FWD) PL PR (FWD) (OPEN) (RAISE) (OUT) HR PROPORTIONAL REDUCING SOLENOID
HL Pb bL4 Di2 Pi2 bL3 Pi3Di3 bL2 bL1 DST bR1 bR2 bR3 bR4 Di1 bR5 (NEGATIVE FLOW CONTROL)
177-2653
(Dimensions: 34 inches x 24 inches)

A1
A2

B1
RENR5445-01

B2

P
B B
T

A4
S4

PB1
LINE PATTERNS
PB2 PB6
R1 R1
A2 B1 A1 A3 Pressure Line
DB2 DB6 DB1 P1 P2 Pi1 Pi2 PSA1 PSA2 DR
PAC FR
M4 Pilot / Load Sensing Pressure
A8 B8 NO1 (SW NO3
BUCKET (TRAVEL) PARKING) (LOCK) U
STICK SWING BOOM Drain / Return Lines
A7 B7 B2
RR Air Line
X2
P2 P1
A6 B6 Component Group

A5 B5 M2 CALLOUTS
OUT R CLOSE DOWN
16 Page,

IN L OPEN UP YY Taps (Pressure, Sampling, Sensor - by letter)


C A2
J2 Do not operate or work on this product unless you have
A4 B4 read and understood the instruction and warnings in the DL DL D Connectors (By letter)
S
relevant Operation and Maintenance Manuals and
DR1 DR2 DR3 DR4 DR5 DR6 TOUT1 TOUT2 PIN relevant service literature. Failure to follow the instruc- Callout Number Component

A3 B3 tions or heed the warnings could result in injury or


(Machine Location from (52) VALVE GP - CONTROL Name
Component LocationsTable)
M1 138-1234
A death. Proper care is your responsibility.
A
Part Number

A2 B2 A1
J1
C
OUT IN M3
A1 B1
B G THIS SCHEMATIC IS FOR THE 330C EXCAVATOR HYDRAULIC SYSTEM
A T
ATTACHMENT: SYSTEM 3: ONE WAY / TWO PUMP FLOW / FOOT SWITCH
D E F X1
MEDIA NUMBER: RENR5445-01
R2
SCHEMATIC PART NUMBER: 190-7789, CHANGE: 00, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

7 6 5 4 3 2 1
MACHINE COMPONENT LOCATIONS
VIEW ALL CALLOUTS

4