You are on page 1of 4

License=Al Sharif Group & KEC Co.

Ltd/SA-881-t Not For Resale ,1/23/2023 8:24:17 PM Saudi Time


INSPECTION AND TEST PLAN (ITP) FOR LATTICE STEEL STRUCTURES

Type Sample

Contract No. / Project Title:


Manufacturer Name: ITP No. : ITP-TLSS-01
Plant Location: Review Cycle No :
Material / Equipment Description: Lattice Steel Structures Date:
Type of Material / Equipment
No. of days:

Equipment Technical data (To be filled by the manufacturer):


Rated Voltage (Ur [kV])
Highest Voltage (Um [kV])
Rated Current (A) (Not Applicable)
Rated Frequency (Hz) 60 (Not Applicable)
SEC/National Grid SA Specification No. 20-TMSS-01, Rev.01

Applicable Insp. Acceptance Tests Tentative Remarks Mfr’s


Item Tests Description Test Procedure Sample
standards Type Criteria Location Date Compliance
1 Main Inspection

Satisfactory
W
workmanship,
20-TMSS-01 and/or
1.1 Visual check and free from
RC
surface defects
As per Approved
W drawings within
1.2 Dimensional check 20-TMSS-01 Approved drawings
and/or specified
RC Tolerances
Mild Steel : ASTM A36M
JIS G 3101 SS400 Verification of mill
1.3 HT Steel : ASTM A572M W test certificates
Review mill test certificates 20-TMSS-01
GR50, JIS G3101 SS540 and/or
Plate:ASTM A572 GR50 or RC
equivalent
1.4 Mechanical Properties ASTM A36M
-:Yield Strength ASTM A572M ASTM A36M
-:Tensile Strength 20-TMSS-01 W ASTM A572M
-:Elongation
-:Bend test.
Chemical Properties ASTM A36M ASTM A36M
1.5 20-TMSS-01 W
-:Carbon ASTM A572M ASTM A572M
ITP-TLSS-01 Standards & Specifications Department PAGE 1 OF 3

License=Al Sharif Group & KEC Co. Ltd/SA-881-t Not For Resale ,1/23/2023 8:24:17 PM Saudi Time
INSPECTION AND TEST PLAN (ITP) FOR LATTICE STEEL STRUCTURES

-: Manganese
-: Sulfur
-: Phosphorous
-: Silicon
Fasteners Bolt/Nut : ASTM A394 (type ASTM A 394
Nuts/Bolts/Washers/ 0), ASTM A 563M, ASTM A 563 M
Paulnuts JIS B 1051/1052, CL508/5 W ASTM F 436 M
1.6 -:Visual 20-TMSS-01 Paul Nut:DIN 7967 and/or DIN 7967
-:Dimensional Washers : ASTM F 436M RC 01-TMSS-01
-:Zinc coating DIN 7989 20-TMSS-01
-:Tensile test
Proto Assembly
2
Inspection
Overall Dimension W
Approved Shop & Erection 20-TMSS-01
Configuration 20-TMSS-01 and/or
drawing Clause 4.3.7
Fitment RC
3 Galvanization Inspection
Free from Black Spots, Membrs 86/130
-:Coating thickness
Lumps, Spike um
-:Visual check W
ASTM A123; ASTM A780
-:Adhesion 20-TMSS-01 and/or
ASTM A90M. Nut, bolt &
-:Stripping test RC
ASTM A239, washers
-:Preece test
53 um
4 Dispatch Inspection
20-TMSS-01 &
20-TMSS-01
01-TMSS-01
4.1 Marking / Packing & NA
RC Packing List,
01-TMSS-01
Delivery Note
20-TMSS-01
20-TMSS-01 &
4.2 Documentation & NA RC
01-TMSS-01
01-TMSS-01

Legend: W = Witness [by SEC/National Grid SA Engineers. and/or SEC approved 3rd Party Independent Inspection Agency (IIA) Inspector]
RC = Review of Certificates [by SEC/National Grid SA Engineers. and/or approved 3rd Party Independent Inspection Agency (IIA) Inspector]

ITP-TLSS-01 Standards & Specifications Department PAGE 2 OF 3

License=Al Sharif Group & KEC Co. Ltd/SA-881-t Not For Resale ,1/23/2023 8:24:17 PM Saudi Time
INSPECTION AND TEST PLAN (ITP) FOR LATTICE STEEL STRUCTURES

General Instructions:
1- Manufacturer’s compliance shall be indicated in front of each test.
2- Approved Data Schedule & final drawings for the equipment / Material shall be attached.
3- Test Procedure & Day-to-day activity schedule shall be attached for approval.
4- The ITP must be duly signed and stamped by manufacturer's authorized personnel.
5- This document is valid for testing after S&SD approval.

Prepared by (Mfr's authorized QC test inspector) Approved by: (Mfr's authorized QA/QC personnel)

Date:

Date:
Manufacturer Stamp

S&SD Approval

ITP-TLSS-01 Standards & Specifications Department PAGE 3 OF 3

License=Al Sharif Group & KEC Co. Ltd/SA-881-t Not For Resale ,1/23/2023 8:24:17 PM Saudi Time