You are on page 1of 27

STRUCTURAL CALCULATION REPORT

SS RAILING POST WITH PATCHED GLAZING

INORBIT MALL - HYDERABAD

FOR

WIND PRESSURE 1.2 kPa


Live Load : 2.25 kN/m
01 Contents

Sr No Content   Page No.

1 Contents

2 Drawing Reference

3 GLASS REPORT

4 SS Railing Staad

5 Base Plate & Anchor Report


Key Plan

S.S HAND RAIL AS


PER SPEC.

GENERAL NOTES:-
- Information within the drawing is copyright of Envelopetechnik at all time and shall not
to be used for purposes other than design co-ordination of this particular project.

- All dimensions are in millimetres unless noted otherwise. All dimensions shall be verified
on site and approved. Do not scale from drawings.

- This drawing is read in conjunction with other relevant architectural, structural , MEP
drawings as well as technical specifications, BOQ and conditions of contract.

- Performance shall meet the requirements of the technical specifications at all the time.

- This drawing is for design intent only, not for Construction. Although it suggests some
materials, minimum thickness, techniques and methods, the Contractor must provide the
solution for the work. Should the Contractor adopt the details or arrangements indicated on
this drawings, it shall be deemed that he has checked the materials, their thickness, their
buildability and performance in terms of all relevant regulations and codes of practice, and
manufacturers' recommendations for any products referred to.

- Where this drawing identifies preferred systems and materials, the Contractor is to
confirm them as being for their specified and intended purpose with the Bidding return. If no
such specific confirmation is received, then the submission of the Bidding return itself shall
constitute such a confirmation. In absence of any such proposals, comments or observations,
the contractor shall be deemed to have accepted and approved such requirements,
stipulations or preferences which shall then form part of this building and contract.

INSIDE
OUTSIDE LAMINATED GLASS AS
PER SPEC.

1050 mm
S.S LUMINIUM MEMBER AS
PER SPEC.

1200 mm
NON-STANING WEATHER SEALANT
WITH CLOSE CELL BACKER ROD

CSK ANCHOR BOLT


NON-STANING WEATHER SEALANT AS PER STRC REQ.
WITH CLOSE CELL BACKER ROD
200 mm

POWDER COATED ALUMINIUM SHEET


CLADDING AS PER APPROVAL
50 mm

300 mm
18 mm
SLOPE
SS BASE PLATE
50 mm

00 08-11-22 FZ TENDER
Rev Date By Description
DSGN AT
50 mm

DRWN AT
50 mm CHKD MK
APPD MS
NAME SIGN DATE
Client:
15 mm INORBIT MALL
25 mm 40 mm 120 mm 50 mm 150 mm Mindspace, Madhapur-Telangana.

Architect:

P.G Patki Architects


FF
L
Facade Consultant:
50 mm

Project Name:

INORBIT MALL
225 mm 300 mm HYDERABAD

250 mm
Drawing Title:
GLASS RAILING WITH MOTIF PANEL
JAMB SECTION DETAIL
01 GLASS RAILING WITH MOTIF PANEL JAMB SECTION DETAIL
Drawing No: 2021230-TD-DT-619
DT- 619 SCALE - 1:2 INORBIT MALL INDICATIVE 3D VIEW Released for: Scale: Size: Rev.No.
TENDER AS SHOWN A1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date07-Feb-19 Chd

Client File glass.std Date/Time 12-Feb-2023 18:40

Job Information
Engineer Checked Approved

Name:
Date: 07-Feb-19

Project ID
Project Name

Structure Type SPACE FRAME

Number of Nodes 154 Highest Node 156


Number of Plates 130 Highest Plate 130

Number of Basic Load Cases 3


Number of Combination Load Cases 2

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DL
Primary 2 WL
Primary 4 LL
Combination 3 DL+WL
Combination 5 DL+LL

Plate Thickness
Prop Node A Node B Node C Node D Material
(cm) (cm) (cm) (cm)
1 1.200 1.200 1.200 1.200 GLASS

Materials
Mat Name E ν Density α
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 GLASS 70.000 0.220 2.55E+3 0.000
3 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
4 ALUMINUM 68.948 0.330 2.71E+3 23E -6
5 CONCRETE 21.718 0.170 2.4E+3 10E -6

Primary Load Cases


Number Name Type

1 DL Dead
2 WL Wind

Print Time/Date: 14/02/2023 00:17 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 1 of 5
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date07-Feb-19 Chd

Client File glass.std Date/Time 12-Feb-2023 18:40

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

3 DL+WL 1 DL 1.00
2 WL 1.00
5 DL+LL 1 DL 1.00
4 LL 1.00

1.330m

0.500m

1.000m

Y
X
Z Load 1

Whole Structure

-0.001 N/mm2
-0.001 N/mm2
-0.001 N/mm2
1.330m -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 0.500m
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
1.000m -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2 -0.001 N/mm2
Y -0.001 N/mm2 -0.001 N/mm2
X
Z -0.001 N/mm2
-0.001 N/mm2 Load 2
-0.001 N/mm2

WIND 1.2 KPA

Print Time/Date: 14/02/2023 00:17 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 2 of 5
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date07-Feb-19 Chd

Client File glass.std Date/Time 12-Feb-2023 18:40

0.800 kN

1.330m

0.500m

1.000m

Y
X
Z Load 4

LIVE LOAD IMPACT LOAD 0.8 KN

Max Absolute
N/mm2
<= 0.754
2.63
4.51
6.38
8.26
10.1
12
13.9
15.8
17.6
19.5
21.4
23.3
25.1
27
28.9
>= 30.8

Y
X
Z Load 5

MAX STRESS < 36 MPA ,AS PER ASTM 1300,SAFE

Print Time/Date: 14/02/2023 00:17 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 3 of 5
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date07-Feb-19 Chd

Client File glass.std Date/Time 12-Feb-2023 18:40

Node Displacement Summary


Node L/C X Y Z Resultant rX rY rZ
(mm) (mm) (mm) (mm) (rad) (rad) (rad)
Max X 147 1:DL 0.000 -0.000 0.000 0.000 0.000 0.000 0.000
Min X 1 1:DL -0.000 -0.000 0.000 0.000 0.000 0.000 -0.000
Max Y 5 1:DL 0.000 0.000 0.000 0.000 0.000 0.000 -0.000
Min Y 87 1:DL -0.000 -0.001 0.000 0.001 0.000 0.000 0.000
Max Z 156 4:LL 0.000 0.000 9.630 9.630 0.029 -0.010 0.000
Min Z 90 2:WL 0.000 0.000 -6.967 6.967 -0.006 -0.001 0.000
Max rX 156 4:LL 0.000 0.000 9.630 9.630 0.029 -0.010 0.000
Min rX 155 2:WL 0.000 0.000 -1.722 1.722 -0.006 -0.011 0.000
Max rY 16 2:WL 0.000 0.000 0.000 0.000 -0.003 0.015 0.000
Min rY 152 2:WL 0.000 0.000 0.000 0.000 -0.003 -0.015 0.000
Max rZ 152 1:DL 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Min rZ 16 1:DL 0.000 0.000 0.000 0.000 0.000 0.000 -0.000
Max Rst 156 4:LL 0.000 0.000 9.630 9.630 0.029 -0.010 0.000

0.800 kN

X = 0.013 kN
Y = 0.122 kN
Z = -1.257 kN
MX = FREE
MY = FREE
MZ = FREE

X = -0.013 kN
Y = 0.122 kN
Z = -0.183 kN
MX = FREE
X = -0.047 kN
MY = FREE
Y = 0.077 kN
MZ = FREE
Z = 0.457 kN
MX = FREE
MY = FREE
MZ = FREE

Y
X
Z X = 0.047 kN
Y = 0.077 kN Load 5
Z = 0.183 kN
MX = FREE
MY = FREE
MZ = FREE

Whole Structure Loads 4.45033kN:1m 5 DL+LL

Print Time/Date: 14/02/2023 00:17 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 4 of 5
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date07-Feb-19 Chd

Client File glass.std Date/Time 12-Feb-2023 18:40

-0.001 N/mm2
-0.001 N/mm2
-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2 X = 0.013 kN
-0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2 Y = 0.122 kN
-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 Z = 0.638 kN
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 MX = FREE
-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 MY = FREE
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 -0.001
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 N/mm2 -0.001 N/mm2 MZ = FREE
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2 -0.001
N/mm2-0.001 N/mm2-0.001 N/mm2 N/mm2
-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2-0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2
X = -0.013 kN -0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 -0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2-0.001 N/mm2
Y = 0.122 kN -0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2
Z = 0.638 kN -0.001 N/mm2-0.001 N/mm2 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2-0.001 N/mm2
MX = FREE -0.001 N/mm2-0.001 N/mm2-0.001 N/mm2 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 -0.001 N/mm2 X = -0.047 kN
MY = FREE -0.001 N/mm2-0.001 N/mm2 N/mm2-0.001 N/mm2
-0.001 N/mm2-0.001 N/mm2-0.001 -0.001 N/mm2 Y = 0.077 kN
Y MZ = FREE N/mm2
X -0.001 N/mm2-0.001 N/mm2 Z = 0.160 kN
-0.001 N/mm2-0.001 N/mm2
Z -0.001 N/mm2-0.001 N/mm2 MXLoad
= FREE
3
-0.001 N/mm2 MY = FREE
-0.001 N/mm2
-0.001 N/mm2 MZ = FREE

X = 0.047 kN
Y = 0.077 kN
Z = 0.160 kN
MX = FREE
MY = FREE
MZ = FREE

Whole Structure Loads 4.45033kN:1m 3 DL+WL

Print Time/Date: 14/02/2023 00:17 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 5 of 5
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date14-Feb-23 Chd

Client File MS RAILING.std Date/Time 14-Feb-2023 00:58

Job Information
Engineer Checked Approved

Name:
Date: 14-Feb-23

Project ID
Project Name

Structure Type SPACE FRAME

Number of Nodes 21 Highest Node 21


Number of Elements 20 Highest Beam 24

Number of Basic Load Cases 3


Number of Combination Load Cases 4

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DL
Primary 3 LL -LINE
Primary 4 WL
Combination 6 DL+LL LINE
Combination 7 DL+WL
Combination 9 1.5DL+1.5LL LINE
Combination 10 1.5DL+1.5WL

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 TUB100504 10.900 44.900 134.000 109.865 STAINLESSSTEEL
2 PIP483M 4.530 11.600 11.600 23.171 STAINLESSSTEEL

Materials
Mat Name E ν Density α
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6

Primary Load Cases


Number Name Type

1 DL Dead
Print Time/Date:
3 14/02/2023 01:01
LL -LINE STAAD.Pro V8i (SELECTseries
Live 6) 20.07.11.90 Print Run 1 of 5

4 WL Wind
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date14-Feb-23 Chd

Client File MS RAILING.std Date/Time 14-Feb-2023 00:58

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

6 DL+LL LINE 1 DL 1.00


3 LL -LINE 1.00
7 DL+WL 1 DL 1.00
4 WL 1.00
9 1.5DL+1.5LL LINE 1 DL 1.50
3 LL -LINE 1.50
10 1.5DL+1.5WL 1 DL 1.50
4 WL 1.50

1.330m

1.330m

1.050m

Y
X
Z Load 9

Whole Structure

Print Time/Date: 14/02/2023 01:01 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 2 of 5
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date14-Feb-23 Chd

Client File MS RAILING.std Date/Time 14-Feb-2023 00:58

Entity Color Legend


TUB100504
PIP483M

1.330m
48 DIA ,3mm thk pipe

1.330m
1.050m

Y
X
100X50X4 SS TUBE
Z
Load 9

Whole Structure

1.330m

2.250 kN/m

1.330m
1.050m

2.250 kN/m

Y
X
Z
Load 3

Whole Structure Loads 0.1kN:1m 3 LL -LINE

Print Time/Date: 14/02/2023 01:01 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 3 of 5
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date14-Feb-23 Chd

Client File MS RAILING.std Date/Time 14-Feb-2023 00:58

-0.240 kN
1.330m
-1.200 kN

-0.150 kN
-0.320 kN

-0.240 kN
1.330m
1.050m -1.200 kN

-0.150 kN
-0.320 kN

-0.240 kN

-1.200 kN

-0.150 kN
Y
X -0.320 kN
Z
Load 4

Whole Structure Loads 4.0024kN:1m 4 WL

7.7e-005
0.384
0.488

0.191
0.701

0.408
7.7e-005
0.222
0.242

0.351 0.514
0.701

0.779
7.7e-005
0.384
0.488

0.191 0.989

0.408

Y
X
Z 0.514 Load 4

ss utilization <1 ,safe

Print Time/Date: 14/02/2023 01:01 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 4 of 5
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date14-Feb-23 Chd

Client File MS RAILING.std Date/Time 14-Feb-2023 00:58

Max: 1.884 mm
Max: 1.650 mm
Max: 1.502 mm

Max: 3.922 mm Max: 0.771 mm

Max: 3.818 mm
Max: 3.373 mm
Max:
Max:3.067 mm
3.054 mm
Max: 0.104 mm

Max: 3.922 mm

Max: 1.581 mm

Max: 1.884 mm
Max: 1.650 mm
Max: 1.502 mm
Max: 0.214 mm

Max: 0.771 mm

Y Max: 0.104 mm
X Load 6 : Displacement
Z
Displacement - mm

Whole Structure Displacements 20mm:1m 6 DL+LL LINE, DEFLECTION < L/150,SAFE

3.375 kN/m

3.375 kN/m

X = -0.162 kN
Y = 0.090 kN
Z = -2.138 kN
MX = -2.074 kN-m
MY = -0.320 kN-m
MZ = 0.132 kN-m

X = -0.000 kN
Y = 0.109 kN
Z = -4.702 kN
MX = -4.366 kN-m
MY = -0.000 kN-m
Y
X MZ = 0.000 kN-m
Z
Load 9

X = 0.162 kN
Y = 0.090 kN
Z = -2.138 kN
MX = -2.074 kN-m
MY = 0.320 kN-m
Whole Structure Loads 4.0024kN:1m 9 1.5DL+1.5LL LINE

Print Time/Date: 14/02/2023 01:01 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 5 of 5
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R V3 + HIT-V-R M12
Return period (service life in years): 50
Item number: not available (element) / 2262134 HIT-HY 200-R V3
(adhesive)
Effective embedment depth: hef,act = 120.0 mm (hef,limit = - mm)
Material: A4
Evaluation Service Report: ETA 19/0601
Issued I Valid: 02/12/2021 | -
Proof: Design Method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 16.0 mm

Anchor plate :
R lx x ly x t = 330.0 mm x 180.0 mm x 16.0 mm; (Recommended plate thickness: 16.0 mm)

Profile: Rectangular Hollow Sections India, 100x50x4; (L x W x T) = 100.0 mm x 50.0 mm x 4.0 mm


Base material: 2
uncracked concrete, M 30, fc,cube = 30.00 N/mm ; h = 300.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to EOTA TR 029, 5.2.2.6 present.

Application also possible with HVU2 + HAS(-E)R M12_hef1 under the selected boundary conditions.
More information in section Alternative fastening data of this report.

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = -0.150; Vx = 0.000; Vy = -4.700; no no 85
Mx = 4.360; My = 0.000; Mz = 0.000;

2 Load case/Resulting anchor forces

Anchor reactions [kN] y


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 26.255 2.350 0.000 -2.350
2 26.255 2.350 0.000 -2.350 2 x 1
Tension
max. concrete compressive strain: 0.49 [‰]
max. concrete compressive stress: 14.77 [N/mm ]
2

resulting tension force in (x/y)=(0.0/0.0): 52.510 [kN]


resulting compression force in (x/y)=(0.0/-82.8): 52.660 [kN] Compression

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 26.255 31.551 84 OK
Combined pullout-concrete cone failure** 52.510 70.515 75 OK
Concrete Breakout Failure** 52.510 61.834 85 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel Strength

N
NSd £ NRd,s = Rk,s EOTA TR 029, Table 5.2.2.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


59.000 1.870 31.551 26.255

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

3.2 Combined pullout-concrete cone failure

N
NSd £ NRd,p = Rk,p EOTA TR 029, Table 5.2.2.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y s,Np · y g,Np · y ec1,Np · y ec2,Np · y re,Np EOTA TR 029, Eq. (5.2)
Ap,N
0
NRk,p = p · d · hef · t Rk EOTA TR 029, Eq. (5.2a)
0
Ap,N = scr, Np · scr,Np EOTA TR 029, Eq. (5.2b)
0.5
t Rk,ucr
scr,Np = 20 · d · (
7.5 )
£ 3 · hef EOTA TR 029, Eq. (5.2c)
s
ccr,Np = cr,Np EOTA TR 029, Eq. (5.2d)
2
c
y s,Np = 0.7 + 0.3 · 1.00 EOTA TR 029, Eq. (5.2e)
ccr,Np £
0,5
y g,Np
0
= y g,Np - (s s )
cr,Np
· (y g,Np - 1) ³ 1.00
0
EOTA TR 029, Eq. (5.2f)
1,5
0
y g,Np = √n - (√n - 1) · (k · √dh · t· f ef
Rk

ck,cube
) ³ 1.00 EOTA TR 029, Eq. (5.2g)
1
y ec1,Np = 1.00 EOTA TR 029, Eq. (5.2h)
2 · ec1,N £
1+
scr,Np
1
y ec2,Np = 1.00 EOTA TR 029, Eq. (5.2h)
2 · ec2,N £
1+
scr,Np
h
y re,Np = 0.5 + ef £ 1.00 EOTA TR 029, Eq. (5.2i)
200

2 0 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
174,000 129,600 18.00 360.0 180.0 150.0
0
yc t Rk,ucr [N/mm ]
2
k y g,Np y g,Np
1.018 18.33 3.200 1.000 1.000

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.0 1.000 0.0 1.000 0.950 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
82.928 105.772 1.500 70.515 52.510

Group anchor ID
1, 2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

3.3 Concrete Breakout Failure

N
NSd £ NRd,c = Rk,c EOTA TR 029, Table 5.2.2.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N EOTA TR 029, Eq. (5.3)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef EOTA TR 029, Eq. (5.3a)
0
Ac,N = scr,N · scr,N EOTA TR 029, Eq. (5.3b)
c
y s,N = 0.7 + 0.3 · 1.00 EOTA TR 029, Eq. (5.3c)
ccr,N £
hef
y re,N = 0.5 + 1.00 EOTA TR 029, Eq. (5.3d)
200 £
1
y ec1,N = 1.00 EOTA TR 029, Eq. (5.3e)
2 · ec1,N £
1+
scr,N
1
y ec2,N = 1.00 EOTA TR 029, Eq. (5.3e)
2 · ec2,N £
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
174,000 129,600 180.0 360.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 0.950 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
10.100 72.720 1.500 61.834 52.510

Group anchor ID
1, 2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 2.350 18.910 13 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 4.700 123.669 4 OK
Concrete edge failure in direction y-** 4.700 39.964 12 OK

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)

V
VSd £ VRd,s = Rk,s EOTA TR 029, Table 5.2.3.1
gM,s

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


29.500 1.560 18.910 2.350

4.2 Pryout Strength (Concrete Breakout Strength controls)

V
VSd £ VRd,cp = Rk,cp EOTA TR 029, Table 5.2.3.1
gM,c,p
VRk,cp = k · min (NRk,p; NRk,c) EOTA TR 029, Eq. (5.7), (5.7a)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N EOTA TR 029, Eq. (5.3)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef EOTA TR 029, Eq. (5.3a)
0
Ac,N = scr,N · scr,N EOTA TR 029, Eq. (5.3b)
c
y s,N = 0.7 + 0.3 · £ 1.00 EOTA TR 029, Eq. (5.3c)
ccr,N
hef
y re,N = 0.5 + 1.00 EOTA TR 029, Eq. (5.3d)
200 £
1
y ec1,N = 1.00 EOTA TR 029, Eq. (5.3e)
2 · ec1,V £
1+
scr,N
1
y ec2,N = 1.00 EOTA TR 029, Eq. (5.3e)
2 · ec2,V £
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k-factor k1
174,000 129,600 180.0 360.0 2.000 10.100

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 0.950 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
72.720 1.500 123.669 4.700

Group anchor ID
1, 2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

4.3 Concrete edge failure in direction y-

V
VSd £ VRd,c = Rk,c EOTA TR 029, Table 5.2.3.1
gM,c
0 Ac,V
VRk,c = VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EOTA TR 029, Eq. (5.8)
Ac,V
0 a b 1,5
VRk,c = k1 · dnom · hef · √fck,cube · c1 EOTA TR 029, Eq. (5.8a)
0,5
a = 0.1 · ( ) hef
c1
EOTA TR 029, Eq. (5.8b)
0,2

= 0.1 · (
c )
d nom
b EOTA TR 029, Eq. (5.8c)
1
0 2
Ac,V = 4.5 · c1 EOTA TR 029, Eq. (5.8d)
c2
y s,V = 0.7 + 0.3 · 1.00 EOTA TR 029, Eq. (5.8e)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EOTA TR 029, Eq. (5.8f)


1
2
y a,V =
(cos aV) +
2
(sin2.5a )
V ³ 1.00 EOTA TR 029, Eq. (5.8g)

1
y ec,V = 1.00 EOTA TR 029, Eq. (5.8h)
2 · ec,V £
1+
3 · c1

hef [mm] dnom [mm] k1 a b


120.0 12.00 2.400 0.089 0.060
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
150.0 150,750 101,250

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V


1.000 1.000 1.000 0.0 1.000 1.000
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
40.262 1.500 39.964 4.700

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

5 Combined tension and shear loads (EOTA TR 029, Section 5.2.4)


Steel failure

bN bV a Utilization bN,V [%] Status


0.849 0.124 1.000 82 OK

(bN + bV) / 1.2 £ 1.0

6 Displacements (highest loaded anchor)


Short term loading:

NSk = 19.448 [kN] dN = 0.1290 [mm]


VSk = 1.741 [kN] dV = 0.0870 [mm]
dNV = 0.1556 [mm]
Long term loading:

NSk = 19.448 [kN] dN = 0.2579 [mm]


VSk = 1.741 [kN] dV = 0.1393 [mm]
dNV = 0.2931 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Bore hole cleaning must be performed according to instructions for use (blow 4 times with the hand pump, brush 4 times, blow again 4 times
with the hand pump).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• Edge reinforcement is not required to avoid splitting failure
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

8 Anchor plate stress check


Scope: For the loads / load combinations applied on the anchor plate, an anchor plate stress check is performed (based on the results of a FE
calculation). This stress check contains normal stresses resulting from bending moments in two directions. The user is responsible to select
an anchor plate thickness that meets the requirement per guideline for a rigid anchor plate (to ensure that the assumed load distribution is
(1)
correct). A detailed description can be found in Mallée.

(1)
Mallée, R.; Riemann, H. (1990): Ankerplattenbefestigungen mit Hinterschnittdübeln,
Bauingenieur 65 (1990), S. 49 - 57, Springer VDI-Verlag, 1990
Mallée, R.; Burkhardt, F. (1999): Befestigungen von Ankerplatten mit Dübeln, Beton und
Stahlbetonbau 94, Heft 12, S. 502 - 511, Ernst & Sohn Verlag, 1999

8.1 Base material properties

Steel type: E 250 (Fe 410 W) A


2
Yield stress: fy = 250.00 [N/mm ]
Partial safety factor: gm,s = 1.100
2
Ultimate strength: fu = 410.00 [N/mm ]
2
Young's modulus: Es = 200,000.00 [N/mm ]
Poisson ratio: n = 0.3

8.2 Results

Relevant load combination: LC 01

Stress distribution s 11

2
227.27 [N/mm ]

2
-108.50 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

Stress distribution s 22

2
122.69 [N/mm ]

2
-208.60 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

Deformations (z-direction)
0.5 [mm]

-0.2 [mm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

9 Installation data
Anchor plate, steel: E 250 (Fe 410 W) A; E = 200,000.00 N/mm ; fyk = 250.00
2 Anchor type and diameter: HIT-HY 200-R V3 + HIT-V-R
N/mm
2 M12
Profile: Rectangular Hollow Sections India, 100x50x4; (L x W x T) = 100.0 mm Item number: not available (element) / 2262134 HIT-HY
x 50.0 mm x 4.0 mm 200-R V3 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 40 Nm
Plate thickness (input): 16.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: 16.0 mm Hole depth in the base material: 120.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 150.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HAS-U threaded rod with HIT-HY 200-R V3 injection mortar with 120 mm embedment h_ef, M12, Stainless steel, Hammer drilled
installation per ETA 19/0601

9.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Dispenser including cassette and mixer
• Properly sized drill bit • Proper diameter wire brush • Torque wrench

y
165.0 165.0

90.0

90.0

2 1
x
90.0

90.0

55.0 220.0 55.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 110.0 0.0 - - 150.0 150.0
2 -110.0 0.0 - - 150.0 150.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

10 Alternative fastening
10.1 Alternative fastening data

Anchor type and diameter: HVU2 + HAS(-E)R M12_hef1


Return period (service life in years): 50
Item number: 333126 HAS-E-R M12x110/28 (element) / 2164507
HVU2 M12x110 (capsule)
Effective embedment depth: hef,act = 110.0 mm, hnom = 110.0 mm
Material: A4
Evaluation Service Report: ETA-16/0515
Issued I Valid: 23/08/2022 | -
Proof: Design Method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 16.0 mm

Anchor plate :
R lx x ly x t = 330.0 mm x 180.0 mm x 16.0 mm; (Recommended plate thickness: not calculated)

Profile: Rectangular Hollow Sections India, 100x50x4; (L x W x T) = 100.0 mm x 50.0 mm x 4.0 mm


Base material: 2
uncracked concrete, M 30, fc,cube = 30.00 N/mm ; h = 300.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to EOTA TR 029, 5.2.2.6 present.

Max. Utilization with HVU2 + HAS(-E)R M12_hef1: 84 %


Fastening meets the design criteria!

10.2 Installation data


2
Anchor plate, steel: E 250 (Fe 410 W) A; E = 200,000.00 N/mm ; fyk = 250.00 Anchor type and diameter: HVU2 + HAS(-E)R M12_hef1
2
N/mm
Profile: Rectangular Hollow Sections India, 100x50x4; (L x W x T) = 100.0 mm Item number: 333126 HAS-E-R M12x110/28 (element) /
x 50.0 mm x 4.0 mm 2164507 HVU2 M12x110 (capsule)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 40 Nm
Plate thickness (input): 16.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 110.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 140.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HAS-U threaded rod with HVU2 capsule mortar with 110 mm embedment h_ef, M12_hef1, Stainless steel, Hammer drilled installation per
ETA-16/0515

10.2.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • HVA square drive shafts
• Properly sized drill bit • Proper diameter wire brush • Torque wrench

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.83

www.hilti.in
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Feb 14, 2023 Date: 13/02/2023
Fastening point:

11 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan