GENERAL NOTES:
1. The structural plans and specifications, to the best of our knowledge, comply
with the applicable requirements of the International Building Code 2018.
2. Contractor shall verify all dimensions and conditions at the job site prior to
beginning work and shall report any discrepancies to the engineer.
3. Contractor shall closely coordinate with the owner to verify the exact locations
of proposed equipment scheduled to be placed within the area of work.
4. Refer to plan drawings for location and details of work items not shown on the
structural drawings.

PRODUCED BY AN AUTODESK STUDENT VERSION


5. Omissions or conflicts between various elements of the drawing, notes and
PRODUCED BY AN AUTODESK STUDENT VERSION

details shall be brought to the attention of the engineer and resolved before
proceeding with the work.
6. Contractor shall verify all dimensions and conditions and coordinate with
architectural drawings, drawings from other consultants, project shop drawings
and field conditions.
7. Establish and verify the size and locations of all block outs, inserts, openings,
curbs, bases and pads for architectural, mechanical, electrical and plumbing
with appropriate trade drawings and subcontractors prior to construction.
8. All details shown apply whether specifically referenced or not.
9. Roof Design,
Load Analysis:
Dead Load, Gk (Including finishes) = 0.5 kN/m2
Variable Load, Qk = 0.75 kN/m2
10. Beam & Slab Design,
Beam size: UKB 610 x 305 x 149
Load Analysis:
Dead Load, Gk (Including finishes) = 4.5 kN/m2
Variable Load, Qk= 3.0 kN/m2
11. Column Design,
Column size: UKC 254 × 254 × 167
Assume fixed-fixed
12. Connection Design,
Type of connection used = Bolted
Grade = Grade 5.6