TABLE OF CONTENTS TRANSPORTATION AND COMMUNICATION

OFFICE OF THE BUILDING OFFICIAL


1. PERSPECTIVES
2. LONGITUDINAL SECTION
A-1 3. GROUND FLOOR PLAN
4 SECOND FLOOR PLAN

1 2
1. GROUND FLOORPLAN
A-2 2. SECOND FLOORPLAN
5.50
CITY / DISTRICT / MUNICIPALITY
2.35 3.34 2.16 2.15
1. GENERAL NOTES
LAND USE AND ZONING
1.08 1.11 600x600 MM CEMENT TILES
W/ CEMENT GROUT S-1
A

1.05
300x300 MM CERAMIC FLOOR TILES
S-2

3.05
4.00
MAINTENANCE OFFICE PUMP ROOM

150 MM THK CHB WALL


W/ 20MM THK PLASTER ON BOTH SIDES
UP

1.09
600x600 MM HOMOGENOUS TILES
WITH PEBBLE WASHOUT

B
LINE AND GRADE
CANOPY

2.15
TO SWIMMING POOL

PERSPECTIVE GROUND FLOOR PLAN ARCHITECTURAL

SCALE: 1 : 50MTS
SCALE: 1 : 75MTS

STRUCTURAL

1 2

1 2

RAILINGS
7.81
4.20 m
2.20
2ND FLR FLOOR
1.00 1.00 5.50
LINE
3.20 m
GROUND FLOOR A
CEILING LINE
3.00 m SANITARY
600x600 MM HOMOGENOUS TILES

2.70
WITH PEBBLE WASHOUT

4.00
VIEWING DECK

GROUND FLOOR DN

0.20 m

1.32
NGL
0.00 m
B

ELECTRICAL

LONGITUDINAL SECTION SECOND FLOOR PLAN


SCALE: 1 : 50MTS
SCALE: 1 : 50MTS

MECHANICAL

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. PERSPECTIVES
BERSOLTO, IRA DENISSE TRIOS TEAM

A-1
they are made is executed or not. It shall be unlawful for DRAWN BY:
any person to duplicate or to make copies of said
2. LONGITUDINAL SECTION
3. GROUND FLOOR PLAN
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in 4 SECOND FLOOR PLAN
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued:
LOCATION:
DATE:
1 2

B-2 B-2
A

B-1
B-2

B-2
S-2 S-1

UP

FLOOR FRAMING PLAN


SCALE: 1 : 25MTS

1 2

7.88

3.37 4.79 3.09 3.08


CF-1 CF-1
1.55 1.59 600x600 MM CEMENT TILES
W/ CEMENT GROUT WF-1

A
1.50

300x300 MM CERAMIC FLOOR TILES


4.37

WF-1 WF-1
5.73

MAINTENANCE OFFICE PUMP ROOM

150 MM THK CHB WALL


W/ 20MM THK PLASTER ON BOTH SIDES
UP
1.56

600x600 MM HOMOGENOUS TILES


WF-1 WITH PEBBLE WASHOUT

B
FOOTING DETAIL WITH COLUMN
CF-1 CANOPY CF-1
SCALE: 1 : 25MTS
3.08

TO SWIMMING POOL

FOUNDATION PLAN
SCALE: 1 : 50MTS

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. FLOOR FRAMING PLAN
BERSOLTO, IRA DENISSE TRIOS TEAM

A-2
they are made is executed or not. It shall be unlawful for DRAWN BY:
any person to duplicate or to make copies of said 2. FOUNDATION PLAN
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in
3. FOOTING DETAIL WITH COLUMN
4 SCHEDULE OF BEAMS
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued:
LOCATION:
DATE:
CONCRETE BEAM 2-20mmØ BOTTOM
3-20mmØ TOP
2-20mmØ BOTTOM
3-20mmØ TOP
2-20mmØ EX. TOP 2-20mmØ EX. TOP
10mmØ @ 8"c/c STIRRUPS 10mmØ @ 8"c/c STIRRUPS
SECTION @ SECTION @
MIDSPAN SECTION @
LEFT SUPPORT RIGHT SUPPORT
B B B 3-20mmØ BOTTOM 3-20mmØ BOTTOM
2-20mmØ EX. BOTTOM 2-20mmØ EX. BOTTOM
M T
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS
T
E I T

MID BARS
MID BARS
TOP BARS TOP BARS
LONGITUDINAL SECTION
2A 2B 2A 2B
SCALE: NTS

STIRRUPS 2-20mmØ BOTTOM


2A 2B 2A 2B 3-20mmØ TOP
L/4 L/4 L/4 L/4 2-20mmØ EX. TOP
10mmØ @ 8"c/c STIRRUPS
BOTTOM BARS BOTTOM BARS
L = LENGTH
CONTINUOUS L = LENGTH
CONTINUOUS 3-20mmØ BOTTOM
2-20mmØ EX. BOTTOM
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS

CONCRETE BEAM DETAIL


SCALE: NTS
MIDSPAN OF BEAM
SCALE: NTS

A. UNLESS OTHERWISE NOTED IN PLANS, CAMBER ALL BEAMS AND GIRDERS AT TENSION BARS
LEAST 6mmØ FOR EVERY 4.50M OF SPAN, EXCEPT CANTILEVERS FOR WHICH EMBEDMENT LENGTHS AND LAPPED
THE CAMBER SHALL BE AS NOTED IN PLANS OR AS ORDERED BY THE SPLICED IN MILLIMETERS
ENGINEER BUT IN NO CASE LESS THAN 20mm FOR EVERY 3.0M OF FREE SPAN. BAR SIZE fc' = 20.7 MPa (3000 psi) fc' = 27.6 MPa (4000 psi)
B. IF THE BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED
THE BAR TO THE FARTHER FACE OF THE WALL NOT BE LESS THAN 25mm. 10 MM Ø 300 300 300 300
EMBEDMENT LENGTH SHALL BE AS SHOWN IN A TABLE "A" FOR TENSION BARS 12 MM Ø 300 300 300 300
AND TABLE "B" FOR COMPRESSION BARS UNLESS SPECIFIED IN PLAN. TOP 16 MM Ø 300 400 300 400
BAR SHALL NOT BE SPLICED WITHIN THE COLUMN OR WITHIN A DISTANCE 20 MM Ø 400 550 350 500

TWICE THE MEMBER DEPTH FROM THE FACE OF THE COLUMN. AT LEAST TWO 25 MM Ø 600 800 550 750

STIRRUPS SHALL BE PROVIDED AT ALL SPLICES. 28 MM Ø 750 1000 650 850


32 MM Ø 950 1300 850 1100

C. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mmØ


BAR SEPARATORS SPACED AT 1.0M ON CENTERS. IN NO CASE SHALL THERE
BE LESS THAN TWO (2) SEPARATORS BETWEEN TWO LAYERS OF BARS.
COMPRESSION BARS
D. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL
SHAPES SHALL BE AS SHOWN IN FIG. B-2 UNLESS SPECIFIED ELSEWHERE. EMBEDMENT LENGTHS AND LAPPED
E. WHEN A BEAM CROSSES A GIRDER, REST BEAM ON TOP OF GIRDER BARS, SPLICED IN MILLIMETERS
BEAM REINFORCING BAR SHALL BE SYMMETRICAL ABOUT CENTER LINE BAR SIZE fc' = 20.7 MPa (3000 psi) fc' = 27.6 MPa (4000 psi)
WHENEVER POSSIBLE. (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED STIRRUPS STIRRUPS

F. GENERALLY NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL 10 MM Ø 225 300 200 300
BENDING STRESSES OCCUR, SPLICES WHERE SO PERMITTED SHALL BE 12 MM Ø 275 300 250 300

INDICATED IN THE TABLE 'A' AND 'B'. WELDED SPLICES SHALL DEVELOP IN 16 MM Ø 350 400 325 400

TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. 20 MM Ø 450 500 475 500

NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION IS ALLOWED TO BE 25 MM Ø
28 MM Ø
550
625
625
675
550
625
625
675
TYPICAL BEAM DETAIL
SPLICED THEREIN
32 MM Ø 700 775 700 775 SCALE: 1 : 75MTS

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. CONCRETE BEAM DETAIL
BERSOLTO, IRA DENISSE TRIOS TEAM

S-1
they are made is executed or not. It shall be unlawful for 2. LONGITUDINAL SECTION DRAWN BY:
any person to duplicate or to make copies of said
3.TYPICAL BEAM DETAIL
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in 4 TENSION BARS
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
COMPRESSION BARS CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued:
LOCATION:
DATE:
BEAM COMPUTATION:
BEAM = 225 x 300
THICKNESS = 0.15 m
f’c = 20.7 MPa
fy = 270 MPa
Dead load = 60 KN-m
Live load = 80 KN-m
Width = 225 mm
Depth = 300 mm

Using 2001 NSCP: ⌀ = 0.90


B1 = 0.85 since f’c < 30 MPa

Pb = 0.0382
Pmax = 0.75 Pb = 0.021

Assume:

As = (p) (b) (d)

= (0.04779) (225) (300)

P = 0.0478 / 0.04779
.225 m
.225 m

3-20mmØ TOP
2-20mmØ TOP
.3 m 10mmØ @ 11"c/c STIRRUPS .3 m 10mmØ @ 8"c/c STIRRUPS
2-20mmØ BOTTOM
3-20mmØ BOTTOM

SECTION 2B SECTION 2A

CONCRETE HOLLOW BLOCKS REINFORCEMENT


CONCRETE BEAM CROSS SECTION BLOCK REINFORCEMENT NOTES
SCALE: NTS THK. HORIZONTAL VERTICAL

SLAB DETAIL

WALL REINFORCEMENT VERT.


REMARKS
THK. HORIZONTAL VERTICAL SEC.

SLAB CONST. JOINT OVERHANGING SLAB DETAIL

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. CONCRETE BEAM CROSS SECTION
BERSOLTO, IRA DENISSE TRIOS TEAM 2. SLAB CONST JOINT

S-2
they are made is executed or not. It shall be unlawful for DRAWN BY:
any person to duplicate or to make copies of said
3. OVERHANGING SLAB DETAIL
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in 4 CONCRETE HOLLOW BLOCKS REINFORCEMENT
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued:
LOCATION:
DATE:
SLAB COMPUTATION:

1. Basic Formula:
⌀ = 0.90
f’c = 21 MPa
Where;
b = 1000
M = design moment
d (slab thickness) = 125 mm
C = coefficient from table ACI
Pmin = 0.005
W = Ultimate load (dead load
and live load)
L = c/c span of slab (panel in
consideration)

M = ⌀ f’c b d2 w (1 - 0.59W)
14.4 x 106 = 0.90 (21)(1000)
(125) W (1 – 0.59W)
W = 0.05

Analysis:
At midspan M = (0.036)(25)(4) 2
M = 14.14 kN/m
∴ Mmid = 14.4 At support Midspan and Midsupport
M = (0.048)(25)(4) Area of Steel
M = 19.2 kN/m As = 0.005 (1000) (125)
∴ Msupport = 19.20
SLAB COMPUTATION:
COLUMN DESIGN

0.40

3.88

3 @ 50mm,
rest @ 250mm,
3 @ 50mm,

C1

3.88
NGL
9-16mm dia.
@ .15m SPACING

9-16mm dia.
PLAN @ .15m SPACING
1.30

9-16mm dia.
@ .15m SPACING
0.18 1.07

9-16mm dia. @ .15m SPACING

SECTION

CF-1 1 2

5.50

2.35 3.34 2.16 2.15


CF-1 CF-1
1.08 1.11 600x600 MM CEMENT TILES
W/ CEMENT GROUT WF-1

1.05
300x300 MM CERAMIC FLOOR TILES

3.05
WF-1 WF-1

4.00
MAINTENANCE OFFICE PUMP ROOM

150 MM THK CHB WALL


W/ 20MM THK PLASTER ON BOTH SIDES
UP
1.09

600x600 MM HOMOGENOUS TILES


WF-1 WITH PEBBLE WASHOUT

CF-1 CANOPY CF-1


2.15

TO SWIMMING POOL

SCHEDULE OF COLUMN:
Ø10MM
SIZE DESIGNATION
REMARK WIDTH LENGTH
(M) (M)
C-1 TIES
FOUNDATION PLAN
0.15 0.15 VERT. BAR SCALE: 1 : 50MTS
FOOTING
TO
9 - 16mmØ
TIES BAR
2@50MM, 5@100MM,
5@150MM, REST @ 200MM
FOOTING DETAIL WITH COLUMN
2ND FLOOR
Ø10MM
SCALE: 1 : 75MTS

SCHEDULE OF BEAMS
SECTION REINFORCEMENT STIRRUPS
MARK LEFT SUPPORT MIDSPAN RIGHT SUPPORT CANT STIRRUP NOTES
T B STIRR
TOP BARS BOT. BARS TOP BARS BOT. BARS TOP BARS BOT. BARS SUPPORT STIRRUP A. 10mm Ø;
5 @ 0.05,
B-2 0.45 0.20 9-16mmØ 2-16mmØ 2-16mmØ 9-16mmØ 9-16mmØ 2-16mmØ - A 5 @ 0.10, 5 @ 0.15
REST @ 0.20 TO CL
B-1 0.45 0.20 9-16mmØ 2-16mmØ 2-16mmØ 9-16mmØ 9-16mmØ 2-16mmØ - A

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. FLOOR FRAMING PLAN
BERSOLTO, IRA DENISSE TRIOS TEAM

S-3
they are made is executed or not. It shall be unlawful for DRAWN BY:
any person to duplicate or to make copies of said 2. FOUNDATION PLAN
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in
3. FOOTING DETAIL WITH COLUMN
4 SCHEDULE OF BEAMS
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued:
LOCATION:
DATE:
COMPUTATION
COLUMN COMPUTATION:

Design Requirements:
f’c = 21MPa(3000 psi)
fy = 400 MPa
⌀c = 0.70 (Rectangular) DESIGN PROCEDURES
RebarCross-Section Area: Solve for P0 & PU
⌀20 = 314 mm2 P0 = 0.85 f’c An + fy AST
⌀16 = 201 mm2
⌀12 = 113 mm2 An = Anet
Anet = Agross – AST
DEAD LOAD An = (250) (300) – 4 (201)
WR = (5.5) (4) (1) = 22 An = 74,196 mm2
WC = (5.5) (4) (1) (0.50)(24) = 264
WF = (5.5) (4) (1) (3) = 66
DL = 22 + 264 + 66
DL = 352 KN

LIVE LOAD
LL = (5.5)(4) (2) 4 - ⌀16 VERTICAL BARS
LL = 44 KN

ULS ULTIMATE LIMIT STATE P0 = 0.85 (21) (71,196) + 400 (4 x


Factored Load = 1.4 DL + 1.7 LL 201)
FLOAD = 1.4(352) + 1.7 (44) P0 = 1,645 KN axial resistance
FLOAD = 567.60KN
Pu = ⌀c 0.85 (P0)
LOAD CARRIED BY C1 ⌀c = 0.70 Tied Column
PR = WT x 25% Pu = 0.70 (0.85) (1645)
PR = 567.60 x 0.25 Pu = 978.78 KN
PR = 141.9 KN -Pu > PR
CHECK SLENDERNESS CHECK

Lu = Unsupported Length INCREASE NUMBER OF


r = 0.30 x Dimension in VERTICAL BARS
Consideration
Lu/ r < 34

Lu = 4.20 – 0.40 = 3.80 COLUMN DETAILING:

DIMENSIONS: 300X300
INTRODUCE GRADE BEAM / R/W = 6 - ⌀16 VERTICALBARS
TIE BEAM 10mm ⌀O.C. spaced @ 3-50 mm,
REST @ 250mm

Lu = 3.0 – 0.40