You are on page 1of 1

CONCRETE BEAM 2-20mmØ BOTTOM

3-20mmØ TOP
2-20mmØ BOTTOM
3-20mmØ TOP
2-20mmØ EX. TOP 2-20mmØ EX. TOP
10mmØ @ 8"c/c STIRRUPS 10mmØ @ 8"c/c STIRRUPS
SECTION @ SECTION @
MIDSPAN SECTION @
LEFT SUPPORT RIGHT SUPPORT
B B B 3-20mmØ BOTTOM 3-20mmØ BOTTOM
2-20mmØ EX. BOTTOM 2-20mmØ EX. BOTTOM
M T
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS
T
E I T

MID BARS
MID BARS
TOP BARS TOP BARS
LONGITUDINAL SECTION
2A 2B 2A 2B
SCALE: NTS

STIRRUPS 2-20mmØ BOTTOM


2A 2B 2A 2B 3-20mmØ TOP
L/4 L/4 L/4 L/4 2-20mmØ EX. TOP
10mmØ @ 8"c/c STIRRUPS
BOTTOM BARS BOTTOM BARS
L = LENGTH
CONTINUOUS L = LENGTH
CONTINUOUS 3-20mmØ BOTTOM
2-20mmØ EX. BOTTOM
2-20mmØ TOP
10mmØ @ 11"c/c STIRRUPS

CONCRETE BEAM DETAIL


SCALE: NTS
MIDSPAN OF BEAM
SCALE: NTS

A. UNLESS OTHERWISE NOTED IN PLANS, CAMBER ALL BEAMS AND GIRDERS AT TENSION BARS
LEAST 6mmØ FOR EVERY 4.50M OF SPAN, EXCEPT CANTILEVERS FOR WHICH EMBEDMENT LENGTHS AND LAPPED
THE CAMBER SHALL BE AS NOTED IN PLANS OR AS ORDERED BY THE SPLICED IN MILLIMETERS
ENGINEER BUT IN NO CASE LESS THAN 20mm FOR EVERY 3.0M OF FREE SPAN. BAR SIZE fc' = 20.7 MPa (3000 psi) fc' = 27.6 MPa (4000 psi)
B. IF THE BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED
THE BAR TO THE FARTHER FACE OF THE WALL NOT BE LESS THAN 25mm. 10 MM Ø 300 300 300 300
EMBEDMENT LENGTH SHALL BE AS SHOWN IN A TABLE "A" FOR TENSION BARS 12 MM Ø 300 300 300 300
AND TABLE "B" FOR COMPRESSION BARS UNLESS SPECIFIED IN PLAN. TOP 16 MM Ø 300 400 300 400
BAR SHALL NOT BE SPLICED WITHIN THE COLUMN OR WITHIN A DISTANCE 20 MM Ø 400 550 350 500

TWICE THE MEMBER DEPTH FROM THE FACE OF THE COLUMN. AT LEAST TWO 25 MM Ø 600 800 550 750

STIRRUPS SHALL BE PROVIDED AT ALL SPLICES. 28 MM Ø 750 1000 650 850


32 MM Ø 950 1300 850 1100

C. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mmØ


BAR SEPARATORS SPACED AT 1.0M ON CENTERS. IN NO CASE SHALL THERE
BE LESS THAN TWO (2) SEPARATORS BETWEEN TWO LAYERS OF BARS.
COMPRESSION BARS
D. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL
SHAPES SHALL BE AS SHOWN IN FIG. B-2 UNLESS SPECIFIED ELSEWHERE. EMBEDMENT LENGTHS AND LAPPED
E. WHEN A BEAM CROSSES A GIRDER, REST BEAM ON TOP OF GIRDER BARS, SPLICED IN MILLIMETERS
BEAM REINFORCING BAR SHALL BE SYMMETRICAL ABOUT CENTER LINE BAR SIZE fc' = 20.7 MPa (3000 psi) fc' = 27.6 MPa (4000 psi)
WHENEVER POSSIBLE. (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED STIRRUPS STIRRUPS

F. GENERALLY NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL 10 MM Ø 225 300 200 300
BENDING STRESSES OCCUR, SPLICES WHERE SO PERMITTED SHALL BE 12 MM Ø 275 300 250 300

INDICATED IN THE TABLE 'A' AND 'B'. WELDED SPLICES SHALL DEVELOP IN 16 MM Ø 350 400 325 400

TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. 20 MM Ø 450 500 475 500

NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION IS ALLOWED TO BE 25 MM Ø
28 MM Ø
550
625
625
675
550
625
625
675
TYPICAL BEAM DETAIL
SPLICED THEREIN
32 MM Ø 700 775 700 775 SCALE: 1 : 75MTS

GROUP TEAM: ARCHITECT RA 9266 Sec. 33. Drawings and specifications and other PROJECT TITLE OWNER SHEET CONTENT DESIGNED BY: SHEET NO.
contract documents duly signed, stamped or sealed, as
instruments of service, are the intellectual property and
documents of the architect, whether the object for which 1. CONCRETE BEAM DETAIL
BERSOLTO, IRA DENISSE TRIOS TEAM

S-1
they are made is executed or not. It shall be unlawful for 2. LONGITUDINAL SECTION DRAWN BY:
any person to duplicate or to make copies of said
3.TYPICAL BEAM DETAIL
GAYANILO, MARY JOYCE ANNE FULL NAME
documents for use in the repetition of and for other
projects or buildings, whether executed partly or in 4 TENSION BARS
MABAIT, RIA MARIZ PRC No.: TIN:
whole, without the written consent of architect or author
of said documents.
COMPRESSION BARS CHECKED BY:
PABITON, JANINE CARLA IAPOA No.: Date Issued: Valid Until:
VILLAMOR, CHRISTELLE ANNE PTR No.: Date Issued: