Professional Documents
Culture Documents
FDEP ..............................................................................................................................................................
2-way, direct-acting electro-proportional, pressure compensated flow control valve 1
with reverse flow check
FREP ..............................................................................................................................................................
FLeX Series 3-way, direct-acting, electro-proportional, bypass/restrictive, priority flow 2
control valve
FMDF ..............................................................................................................................................................
Electro-proportional 3-way flow control, valve meter in (740 3
Series)
FMDG ..............................................................................................................................................................
Electro-proportional 3-way flow control, valve meter in (740 4
Series)
FPBD ..............................................................................................................................................................
FLeX Series pilot-operated, normally closed, electro-proportional throttle - flow 2-1 - 5
3000 psi (210 bar)
FPBE ..............................................................................................................................................................
FLeX Series pilot-operated, normally closed, electro-proportional throttle with reverse 6
flow check - flow 2-1 - 3000 psi (210 bar)
FPBF ..............................................................................................................................................................
FLeX Series pilot-operated, normally closed, electro-proportional throttle - flow 2- 7
1
FPBG ..............................................................................................................................................................
FLeX Series pilot-operated, normally closed, electro-proportional throttle with reverse 8
flow check - flow 2-1
FPBI ..............................................................................................................................................................
FLeX Series pilot-operated, normally open, electro-proportional throttle - flow 2- 9
1
FPBJ ..............................................................................................................................................................
FLeX Series pilot-operated, normally open, electro-proportional throttle with reverse 10
flow check - flow 2-1
FPBM ..............................................................................................................................................................
FLeX Series pilot-operated, normally open, electro-proportional throttle - flow 2-1 - 11
3000 psi (210 bar)
FPBN ..............................................................................................................................................................
FLeX Series pilot-operated, normally open, electro-proportional throttle with reverse 12
flow check - flow 2-1 - 3000 psi (210 bar)
FPBU ..............................................................................................................................................................
FLeX Series electro-proportional, blocking poppet throttle - normally 13
closed
FQBA ..............................................................................................................................................................
Fixed orifice, flow fuse 14
valve
FQCA ..............................................................................................................................................................
Fixed orifice, flow fuse 15
valve
FQEA ..............................................................................................................................................................
Fixed orifice, flow fuse 16
valve
FQGA ..............................................................................................................................................................
Fixed orifice, flow fuse 17
valve
FQIA ..............................................................................................................................................................
Fixed orifice, flow fuse 18
valve
NFBC ..............................................................................................................................................................
Fully adjustable needle 19
valve
NFCC ..............................................................................................................................................................
Fully adjustable needle 20
valve
NFCD ..............................................................................................................................................................
Fully adjustable needle 21
valve
Table of Contents
NFDC ..............................................................................................................................................................
Fully adjustable needle 22
valve
NFDD ..............................................................................................................................................................
Fully adjustable needle 23
valve
NFEC ..............................................................................................................................................................
Fully adjustable needle 24
valve
NFED ..............................................................................................................................................................
Fully adjustable needle 25
valve
NFFC ..............................................................................................................................................................
Fully adjustable needle 26
valve
NFFD ..............................................................................................................................................................
Fully adjustable needle 27
valve
NCBB ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 28
check
NCCB ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 29
check
NCCC ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 30
check
NCCD ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 31
check
NCEB ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 32
check
NCEC ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 33
check
NCFB ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 34
check
NCFC ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 35
check
NCGB ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 36
check
NCGC ..............................................................................................................................................................
Fully adjustable needle valve with reverse flow 37
check
NFAB ..............................................................................................................................................................
Fully adjustable needle valve - pilot 38
capacity
CNAC ..............................................................................................................................................................
Fixed orifice, non-pressure compensated, flow control valve with reverse flow 39
check
CNCC ..............................................................................................................................................................
Fixed orifice, non-pressure compensated, flow control valve with reverse flow 40
check
CNEC ..............................................................................................................................................................
Fixed orifice, non-pressure compensated, flow control valve with reverse flow 41
check
CNGC ..............................................................................................................................................................
Fixed orifice, non-pressure compensated, flow control valve with reverse flow 42
check
Table of Contents
CNIC ..............................................................................................................................................................
Fixed orifice, non-pressure compensated, flow control valve with reverse flow 43
check
FXAA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 44
valve
FXAG ..............................................................................................................................................................
Flush mount, pressure compensated flow 45
control
FXAM ..............................................................................................................................................................
Insert style, pressure compensated flow 46
control
FXBA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 47
valve
FXCA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 48
valve
FXDA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 49
valve
FXEA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 50
valve
FXFA ..............................................................................................................................................................
Fixed orifice, pressure compensated flow control 51
valve
FCBB ..............................................................................................................................................................
Fixed orifice pressure compensated flow control valve with reverse flow 52
check
FCCB ..............................................................................................................................................................
Fixed orifice pressure compensated flow control valve with reverse flow 53
check
FCDB ..............................................................................................................................................................
Fixed orifice pressure compensated flow control valve with reverse flow 54
check
FCEB ..............................................................................................................................................................
Fixed orifice pressure compensated flow control valve with reverse flow 55
check
FCFB ..............................................................................................................................................................
Fixed orifice pressure compensated flow control valve with reverse flow 56
check
FDBA ..............................................................................................................................................................
Fully adjustable pressure compensated flow control valve with reverse flow 57
check
FDCB ..............................................................................................................................................................
Fully adjustable pressure compensated flow control valve with reverse flow 58
check
FDEA ..............................................................................................................................................................
Fully adjustable pressure compensated flow control valve with reverse flow 59
check
FDFA ..............................................................................................................................................................
Fully adjustable pressure compensated flow control valve with reverse flow 60
check
FXDA8 ..............................................................................................................................................................
Ventable fixed orifice, pressure compensated flow control valve with integral T-8A 61
control cavity
FRBA ..............................................................................................................................................................
Fixed orifice, bypass/restrictive, priority, flow control 62
valve
FRCA ..............................................................................................................................................................
Fixed orifice, bypass/restrictive, priority, flow control 63
valve
Table of Contents
FRDA ..............................................................................................................................................................
Fixed orifice, bypass/restrictive, priority, flow control 64
valve
FREA ..............................................................................................................................................................
Fixed orifice, bypass/restrictive, priority, flow control 65
valve
FRFA ..............................................................................................................................................................
Fixed orifice, bypass/restrictive, priority, flow control 66
valve
FVCA ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control 67
valve
FVDA ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control 68
valve
FVEA ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control 69
valve
FVFA ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control 70
valve
FVCA8 ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve with integral T-8A 71
control cavity
FVDA8 ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve with integral T-8A 72
control cavity
FVEA8 ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve with integral T-8A 73
control cavity
FVFA8 ..............................................................................................................................................................
Ventable, fixed orifice, bypass/restrictive, priority, flow control valve with integral T-8A 74
control cavity
FPCC ..............................................................................................................................................................
Electro-proportional flow control valve - normally 76
closed
FPCH ..............................................................................................................................................................
Electro-proportional flow control valve - normally 78
open
FPFK ..............................................................................................................................................................
Pilot-operated, normally closed, electro-proportional throttle with reverse flow 79
check
FPHK ..............................................................................................................................................................
Pilot-operated, normally closed, electro-proportional throttle with reverse flow 80
check
FMDA ..............................................................................................................................................................
Electro-proportional 3-way flow control valve, meter 81
in
FMDB ..............................................................................................................................................................
Electro-proportional 3-way flow control valve, meter 82
in
FTCA ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional 83
throttle
FTDA ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional 84
throttle
FTEA ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional 85
throttle
FTFA ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional 86
throttle
Table of Contents
FTCAZ ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional throttle with position 87
switch
FTDAZ ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional throttle with position 88
switch
FTEAZ ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional throttle with position 89
switch
FTFAZ ..............................................................................................................................................................
2-way, pilot-shifted, dual path, proportional throttle with position 90
switch
FKBA ..............................................................................................................................................................
2-way, pilot-shifted, proportional 91
throttle
FKCA ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle, high 92
capacity
FKDA ..............................................................................................................................................................
2-way, pilot-shifted, proportional 93
throttle
FKEA ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle, high 94
capacity
FKFA ..............................................................................................................................................................
2-way, pilot-shifted, proportional 95
throttle
FKGA ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle, high 96
capacity
FKHA ..............................................................................................................................................................
2-way, pilot-shifted, proportional 97
throttle
FKIA ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle, high 98
capacity
FKBB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed 99
down
FKCB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed down, high 100
capacity
FKDB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed 101
down
FKEB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed down, high 102
capacity
FKFB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed 103
down
FKGB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed down, high 104
capacity
FKHB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed 105
down
FKIB ..............................................................................................................................................................
2-way, pilot-shifted, proportional throttle with bleed down, high 106
capacity
FSCD ..............................................................................................................................................................
Flow divider 107
valve
Table of Contents
FSDD ..............................................................................................................................................................
Flow divider 108
valve
FSED ..............................................................................................................................................................
Flow divider 109
valve
FSFD ..............................................................................................................................................................
Flow divider 110
valve
FSBD ..............................................................................................................................................................
High accuracy flow divider 111
valve
FSDC ..............................................................................................................................................................
High accuracy flow divider 112
valve
FSEC ..............................................................................................................................................................
High accuracy flow divider 113
valve
FSFC ..............................................................................................................................................................
High accuracy flow divider 114
valve
FSCA ..............................................................................................................................................................
Closed center, flow divider-combiner 115
valve
FSDA ..............................................................................................................................................................
Closed center, flow divider-combiner 116
valve
FSEA ..............................................................................................................................................................
Closed center, flow divider-combiner 117
valve
FSFA ..............................................................................................................................................................
Closed center, flow divider-combiner 118
valve
FSAA ..............................................................................................................................................................
High accuracy, closed center, flow divider-combiner 119
valve
FSBA ..............................................................................................................................................................
High accuracy, closed center, flow divider-combiner 120
valve
FSDG ..............................................................................................................................................................
High accuracy, closed center, flow divider-combiner 121
valve
FSEG ..............................................................................................................................................................
High accuracy, closed center, flow divider-combiner 122
valve
FSFG ..............................................................................................................................................................
High accuracy, closed center, flow divider-combiner 123
valve
FSCH ..............................................................................................................................................................
High capacity, closed center, flow divider-combiner 124
valve
FSDH ..............................................................................................................................................................
High capacity, closed center, flow divider-combiner 125
valve
FSEH ..............................................................................................................................................................
High capacity, closed center, flow divider-combiner 126
valve
FSFH ..............................................................................................................................................................
High capacity, closed center, flow divider-combiner 127
valve
FSCS ..............................................................................................................................................................
Synchronizing, flow divider-combiner 128
valve
Table of Contents
FSDS ..............................................................................................................................................................
Synchronizing, flow divider-combiner 129
valve
FSES ..............................................................................................................................................................
Synchronizing, flow divider-combiner 130
valve
FSFS ..............................................................................................................................................................
Synchronizing, flow divider-combiner 131
valve
FSAS ..............................................................................................................................................................
High accuracy synchronizing, flow divider-combiner 132
valve
FSBS ..............................................................................................................................................................
High accuracy synchronizing, flow divider-combiner 133
valve
FSDR ..............................................................................................................................................................
High accuracy synchronizing, flow divider-combiner 134
valve
FSER ..............................................................................................................................................................
High accuracy synchronizing, flow divider-combiner 135
valve
FSFR ..............................................................................................................................................................
High accuracy synchronizing, flow divider-combiner 136
valve
LRBC ..............................................................................................................................................................
Normally closed, modulating 137
element
LRDC ..............................................................................................................................................................
Normally closed, modulating 138
element
LRFC ..............................................................................................................................................................
Normally closed, modulating 139
element
LRHC ..............................................................................................................................................................
Normally closed, modulating 140
element
LRJC ..............................................................................................................................................................
Normally closed, modulating 141
element
LRBA ..............................................................................................................................................................
Normally closed, modulating element with pilot source from port 142
1
LRDA ..............................................................................................................................................................
Normally closed, modulating element with pilot source from port 143
1
LRFA ..............................................................................................................................................................
Normally closed, modulating element with pilot source from port 144
1
LRHA ..............................................................................................................................................................
Normally closed, modulating element with pilot source from port 145
1
LRJA ..............................................................................................................................................................
Normally closed, modulating element with pilot source from port 146
1
LRDS ..............................................................................................................................................................
Normally closed modulating element with 147
shuttle
LPBC ..............................................................................................................................................................
Normally open, modulating 148
element
LPDC ..............................................................................................................................................................
Normally open, modulating 149
element
Table of Contents
LPFC ..............................................................................................................................................................
Normally open, modulating 150
element
LPFCL ..............................................................................................................................................................
Tuneable, normally open modulating 151
element
LPHC ..............................................................................................................................................................
Normally open, modulating 152
element
LPJC ..............................................................................................................................................................
Normally open, modulating 153
element
LPBA ..............................................................................................................................................................
Normally open, modulating element with pilot source from port 154
1
LPDA ..............................................................................................................................................................
Normally open, modulating element with pilot source from port 155
1
LPFA ..............................................................................................................................................................
Normally open, modulating element with pilot source from port 156
1
LPHA ..............................................................................................................................................................
Normally open, modulating element with pilot source from port 157
1
LPJA ..............................................................................................................................................................
Normally open, modulating element with pilot source from port 158
1
LPJA8 ..............................................................................................................................................................
Normally open, modulating element with integral T-8A control cavity and pilot source 159
from port 1
LPDS ..............................................................................................................................................................
Normally open modulating element with 160
shuttle
LHDT ..............................................................................................................................................................
Normally open, bi-directional, modulating 161
element
LHFT ..............................................................................................................................................................
Normally open, bi-directional, modulating 162
element
LHHT ..............................................................................................................................................................
Normally open, bi-directional, modulating 163
element
LHDA ..............................................................................................................................................................
Bypass/restrictive, priority modulating 164
element
LHFA ..............................................................................................................................................................
Bypass/restrictive, priority modulating 165
element
LHHA ..............................................................................................................................................................
Bypass/restrictive, priority modulating 166
element
LHJA ..............................................................................................................................................................
Bypass/restrictive, priority modulating 167
element
RVBB ..............................................................................................................................................................
Normally closed modulating element valve with relief 168
function
RVCB ..............................................................................................................................................................
Normally closed modulating element valve with relief 169
function
RVEB ..............................................................................................................................................................
Normally closed modulating element valve with relief 170
function
Table of Contents
RVGB ..............................................................................................................................................................
Normally closed modulating element valve with relief 171
function
RVIB ..............................................................................................................................................................
Normally closed modulating element valve with relief 172
function
LRFCL ..............................................................................................................................................................
Tuneable, normally closed, modulating 173
element
Cavity Information
3-Port T-382A
Series Z Cartridges
3/8-24 UNF Cartridge Thread
5 mm Valve Hex Size
11 - 14 Nm Valve Installation Torque
2-Port T-8A
Series P Cartridges
2-Port (Deep) T-8DP
M16 Cartridge Thread
3-Port T-9A
22,2 mm Valve Hex Size
27 - 33 Nm Valve Installation Torque
2-Port T-162A
Series 0 Cartridges
2-Port (Deep) T-162DP
M16 Cartridge Thread
3-Port T-150A
19,1 mm Valve Hex Size
3-Port T-163A
25,4 mm Valve Hex Size
4-Port T-30A
27 - 33 Nm Valve Installation Torque
2-Port T-10A
Series 1 Cartridges
2-Port T-13A
M20 Cartridge Thread
3-Port T-11A
22,2 mm Valve Hex Size
4-Port T-21A
41 - 47 Nm Valve Installation Torque
4-Port T-31A
6-Port T-61A
2-Port T-3A
Series 2 Cartridges 2-Port T-5A
1"-14 UNS Cartridge Thread
3-Port T-2A
28,6 mm Valve Hex Size
4-Port T-22A
61 - 68 Nm Valve Installation Torque
4-Port T-32A
4-Port (Dual path) T-52AD
6-Port T-52A
6-Port T-62A
2-Port T-16A
Series 3 Cartridges 3-Port T-17A
M36 Cartridge Thread
4-Port T-23A
31,8 mm Valve Hex Size
4-Port T-33A
203 - 217 Nm Valve Installation Torque
4-Port (Dual path) T-53AD
6-Port T-53A
6-Port T-63A
2-Port T-18A
Series 4 Cartridges 2-Port (Undercut) T-18AU
M48 Cartridge Thread
3-Port T-19A
41,3 mm Valve Hex Size
3-Port (Undercut) T-19AU
474 - 508 Nm Valve Installation Torque
4-Port T-24A
4-Port (Undercut) T-24AU
4-Port T-34A
4-Port (Dual path) T-54AD
6-Port T-54A
6-Port T-64A
6-Port T-54A
6-Port T-64A
MODEL 2-way, direct-acting electro-proportional, pressure compensated flow control
FDEP valve with reverse flow check
SERIES 3 / CAPACITY: 30 gpm / CAVITY: T-16A
sunhydraulics.com/model/FDEP
Normally closed, electro-proportional pressure-compensated flow control with reverse-flow check valves provide
precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. They
are proportional from nearly closed up to the maximum flow. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a normally closed, electro-proportional, bypass/restrictive, priority flow control valve. The valve takes
an input flow at port 1 and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority
requirement, the excess is bypassed out port 2.
The valve pressure compensates the priority flow for precise flow regulation for applications where there may be
wide pressure fluctuations. Port 2 may also be completely blocked so that the valve can be used as a 2-way,
electro-proportional pressure compensated flow control from 1 to 3.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FMDF
D-Control
X-Control
L-Control M-Control
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at
port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a
metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates
in the 1-to-2 direction and with the addition of an external compensator will provide pressure compensated flow
control.
Flow in the 2-to-3 direction is not proportional and is limited in the interest of increased resolution and capacity.
T-Control Flow capacity in the 2-to-3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has
a separate passage to tank such as a cushion lock circuit. Two FMDFs in conjunction with a cushion lock circuit
create a meter-in/meter-out 3-position 4-way.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
sunhydraulics.com/model/FMDG
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at
port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a
metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates
in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow
control. Flow in the 2 to 3 direction is not proportional.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally,
allowing flow from port 2 to 1. In the open condition, flow from 1 to 2 will cause the valve to auto-close and only pilot
flow will pass from 1 to 2.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally,
allowing flow from port 2 to 1. The check will allow flow from 1 to 2 in either the open or closed condition.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally,
allowing flow from port 2 to 1. In the open condition, flow from 1 to 2 will cause the valve to auto-close and only pilot
flow will pass from 1 to 2.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally,
allowing flow from port 2 to 1. The check will allow flow from 1 to 2 in either the open or closed condition.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
sunhydraulics.com/model/FPBI
This valve is a pilot-operated, normally open, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates a closing force on the pilot stage which pushes the main stage poppet against the seat,
proportionally blocking flow from port 2 to 1. In the open condition, flow from 1 to 2 will cause the valve to auto-
close and only pilot flow will pass from 1 to 2.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally open, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates a closing force on the pilot stage which pushes the main stage poppet against the seat,
proportionally blocking flow from port 2 to 1. The check will allow flow from 1 to 2 in either the open or closed
condition.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally open, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates a closing force on the pilot stage which pushes the main stage poppet against the seat,
proportionally blocking flow from port 2 to 1. In the open condition, flow from 1 to 2 will cause the valve to auto-
close and only pilot flow will pass from 1 to 2.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
This valve is a pilot-operated, normally open, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates a closing force on the pilot stage which pushes the main stage poppet against the seat,
proportionally blocking flow from port 2 to 1. The check will allow flow from 1 to 2 in either the open or closed
condition.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
sunhydraulics.com/model/FPBU
This valve is a normally closed, electro-proportional, blocking poppet throttle that is spring-biased closed.
Energizing the coil generates an opening force on the poppet proportional to the command current, and this force
is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is
proportional to the current. The valve exhibits a large degree of self-compensation in the 2-to-1 direction and will
provide proportional flow control in the 1-to-2 direction with the addition of an external compensator. Full reverse
flow (1-to-2) with 100% command in the 1-to-2 direction is possible without a compensator under all conditions.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
sunhydraulics.com/model/FQBA
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FQCA
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FQEA
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FQGA
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FQIA
Flow fuse cartridges are used to maintain the position of a hydraulic actuator in the event of a hose or line break.
The valve allows flow to and from the actuator but closes instantly if flow from the actuator exceeds the setting of
the valve. NOTE: Because the valve responds so rapidly, it is sensitive to any transient flow above the valve
setting.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFBC
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFCC
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NFCD
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NFDC
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NFDD
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NFEC
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFED
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFFC
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFFD
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to
the maximum orifice diameter. They are not pressure compensated and may be used as flow controls or as shutoff
valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NCBB
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NCCB
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NCCC
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NCCD
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NCEB
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NCEC
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/NCFB
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NCFC
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NCGB
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NCGC
Needle valves with reverse-flow check are fully adjustable orifices used to regulate flow. They are infinitely
adjustable from fully closed up to the maximum orifice diameter. An integral high-capacity check valve provides
unrestricted flow from port 2 to port 1. They are not pressure compensated.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/NFAB
Two-port, pilot-stage needle valves are fully adjustable devices used to regulate pilot flow in a main-stage valve or
to meter in/out flow in low flow applications. These cartridges are designed for pilot flow applications and utilize
Sun's T-8A cavity so they can be used in conjunction with Sun's pilot-operated, main-stage valves.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is
specified by the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is
specified by the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is
specified by the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is
specified by the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, non-pressure-compensated flow control with a reverse flow check. The flow setting is
specified by the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXAA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. A variety of flow rates are available.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXAG
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. A variety of flow rates are available.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXAM
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. A variety of flow rates are available. The THRU port at
the top of the valve can be used as the outlet with port 2 blocked. See cavity drawing for details.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXBA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at
the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXCA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at
the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXDA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at
the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXEA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at
the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FXFA
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out
applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at
the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FCBB
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FCCB
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FCDB
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FCEB
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FCFB
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check
valve provides unrestricted flow from port 2 to port 1. The flow setting is specified by the user and is set at the
factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable
from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from
port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable
from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from
port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable
from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from
port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable
from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from
port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a fixed-orifice, pressure-compensated flow control valve with an integral pilot control cavity. The pilot
control cavity will accept any T-8A pilot control cartridge. This type of valve provides precise flow regulation for
meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by
the user and is set at the factory.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
sunhydraulics.com/model/FRBA
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FRCA
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FRDA
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
sunhydraulics.com/model/FREA
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FRFA
Bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow
at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow
may be used in a secondary circuit.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FVCA
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FVDA
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FVEA
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FVFA
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the
priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The
bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a ventable, bypass/restrictive, fixed-orifice, priority flow control with an integral pilot control cavity. The
pilot control cavity will accept any T-8A pilot pressure or directional control cartridge. It takes an input flow at port 1
and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess
flow is bypassed out of port 2. Bypass flow may be used for a secondary circuit. Depending on which pilot control
valve is installed in the T-8A cavity, priority flow can be selected electrically, manually, hydraulically or
pneumatically.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
This valve is a ventable, bypass/restrictive, fixed-orifice, priority flow control with an integral pilot control cavity. The
pilot control cavity will accept any T-8A pilot pressure or directional control cartridge. It takes an input flow at port 1
and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess
flow is bypassed out of port 2. Bypass flow may be used for a secondary circuit. Depending on which pilot control
valve is installed in the T-8A cavity, priority flow can be selected electrically, manually, hydraulically or
pneumatically.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
This valve is a ventable, bypass/restrictive, fixed-orifice, priority flow control with an integral pilot control cavity. The
pilot control cavity will accept any T-8A pilot pressure or directional control cartridge. It takes an input flow at port 1
and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess
flow is bypassed out of port 2. Bypass flow may be used for a secondary circuit. Depending on which pilot control
valve is installed in the T-8A cavity, priority flow can be selected electrically, manually, hydraulically or
pneumatically.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
This valve is a ventable, bypass/restrictive, fixed-orifice, priority flow control with an integral pilot control cavity. The
pilot control cavity will accept any T-8A pilot pressure or directional control cartridge. It takes an input flow at port 1
and uses it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess
flow is bypassed out of port 2. Bypass flow may be used for a secondary circuit. Depending on which pilot control
valve is installed in the T-8A cavity, priority flow can be selected electrically, manually, hydraulically or
pneumatically.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
sunhydraulics.com/model/FPCC
This valve is a normally closed, electro-proportional throttle that is spring-biased closed. Energizing the coil
generates an opening force on the spool proportional to the command current, and this force is countered by the
spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the
current. The valve exhibits a large degree of self-compensation in the 1-to-2 direction and will provide proportional
flow control in the 2-to-1 direction with the addition of an external compensator. Full reverse flow (2-to-1) with 100%
command in the 2-to-1 direction is possible without a compensator under all conditions.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
sunhydraulics.com/model/FPCH
This valve is a normally open electro-proportional throttle that is spring-biased open. Energizing the coil generates
an closing force on the spool proportional to the command current, and this force is countered by the spring and
flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The
valve exhibits a large degree of self-compensation in the 1-to-2 direction and will provide proportional flow control in
the 2-to-1 direction with the addition of an external compensator. Full reverse flow (2-to-1) with no command in the
2-to-1 direction is possible without a compensator under all conditions.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
X-Control
E-Control
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally.
Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
X-Control
This valve is a pilot-operated, normally closed, electro-proportional throttle with reverse free-flow check. Energizing
E-Control the coil generates an opening force on the pilot stage which vents the main stage poppet to open proportionally.
Metered flow is from port 1 to port 2 with reverse free flow from port 2 to port 1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FMDA
D-Control
X-Control
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at
port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a
metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates
in the 1-to-2 direction and with the addition of an external compensator will provide pressure compensated flow
control.
E-Control L-Control Flow in the 2-to-3 direction is not proportional and is limited in the interest of increased resolution and capacity.
Flow capacity in the 2-to-3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has
a separate passage to tank such as a cushion lock circuit. Two FMDAs in conjunction with a cushion lock circuit
create a meter-in/meter-out 3-position 4-way.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
sunhydraulics.com/model/FMDB
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at
port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a
metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates
in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow
control. Flow in the 2 to 3 direction is not proportional.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
sunhydraulics.com/model/FTCA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
opposes the spring and creates a variable metering orifice between port 2 and 3 that is proportional to the pressure
at 1. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self-compensation
as the load pressure changes.
The valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi
Pilot Volume Displacement .05 in³
Adjustment - No. of CCW Turns from Fully Closed to Fully Open 5
Hysteresis 35 %
Locknut Hex Size 9/16 in.
Locknut Torque 80 - 90 lbf in.
Seal kit - Cartridge Buna: 990152007
Seal kit - Cartridge Viton: 990152006
NOTES When installed in Sun's standard T-52A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTDA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
opposes the spring and creates a variable metering orifice between port 2 and 3 that is proportional to the pressure
at 1. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self-compensation
as the load pressure changes.
The valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi
Pilot Volume Displacement .05 in³
Hysteresis 35 %
Seal kit - Cartridge Buna: 990152007
Seal kit - Cartridge Viton: 990152006
NOTES When installed in Sun's standard T-52A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTEA
This valve is a 2-way, 2-position proportional throttle. Pilot pressure at port 1 opposes the spring and creates a
variable metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the flow
forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
The valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 10 in³/min.@1000 psi
Pilot Volume Displacement .10 in³
Adjustment - No. of CCW Turns from Fully Closed to Fully Open 5
Hysteresis 35 %
Locknut Hex Size 9/16 in.
Locknut Torque 80 - 90 lbf in.
Seal kit - Cartridge Buna: 990053007
Seal kit - Cartridge Viton: 990053006
NOTES When installed in Sun's standard T-53A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTFA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
opposes the spring and creates a variable metering orifice between port 2 and 3 that is proportional to the pressure
at 1. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self-compensation
as the load pressure changes.
The valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 10 in³/min.@1000 psi
Pilot Volume Displacement .10 in³
Adjustment - No. of CCW Turns from Fully Closed to Fully Open 5
Hysteresis 35 %
Locknut Hex Size 9/16 in.
Locknut Torque 80 - 90 lbf in.
Seal kit - Cartridge Buna: 990053007
Seal kit - Cartridge Viton: 990053006
NOTES When installed in Sun's standard T-53A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTCAZ
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The metering passage is
self-compensating.
This valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
This valve incorporates a position switch to provide confirmation that the valve is closed.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi
Pilot Volume Displacement .05 in³
Seal kit - Cartridge Buna: 990152007
Seal kit - Cartridge Viton: 990152006
NOTES When installed in Sun's standard T-52A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTDAZ
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The metering passage is
self-compensating.
This valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
This valve incorporates a position switch to provide confirmation that the valve is closed.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 5 in³/min.@1000 psi
Pilot Volume Displacement .05 in³
Seal kit - Cartridge Buna: 990152007
Seal kit - Cartridge Viton: 990152006
NOTES When installed in Sun's standard T-52A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTEAZ
This valve is a 2-way, 2-position proportional throttle. Pilot pressure at port 1 creates a metering orifice between port
2 and 3 that is proportional to the pressure at 1. The metering passage is self-compensating.
This valve uses a dual-path design, Ports 2 and 3 incorporate a double-port area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 10 in³/min.@1000 psi
Pilot Volume Displacement .10 in³
Seal kit - Cartridge Buna: 990053007
Seal kit - Cartridge Viton: 990053006
NOTES When installed in Sun's standard T-53A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FTFAZ
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The metering passage is
self-compensating.
This valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
This valve incorporates a position switch to provide confirmation that the valve is closed.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
Pilot Pressure Required for Full Shift at Rated Flow 290 - 340 psi
Maximum Operating Pressure 5000 psi
Maximum Valve Leakage at 110 SUS (24 cSt) 10 in³/min.@1000 psi
Pilot Volume Displacement .10 in³
Seal kit - Cartridge Buna: 990053007
Seal kit - Cartridge Viton: 990053006
NOTES When installed in Sun's standard T-53A line mount manifold, plug unused ports and expect higher pressure drops.
sunhydraulics.com/model/FKBA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKCA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKDA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKEA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKFA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKGA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKHA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKIA
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKBB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKCB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKDB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKEB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKFB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKGB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKHB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FKIB
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1
creates a metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the
flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes.
This valve includes a bleed-down feature which connects ports 3 to 4 in the spring-biased position. The bleed-down
feature is useful when the valve is used as a meter-in flow control in circuits which include counterbalance valves
downstream of port 3. The bleed-down connection is closed as the valve is piloted with increasing pressure at port
1.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSCD
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDD
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSED
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFD
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSBD
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDC
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSEC
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFC
Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a
circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional
hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that
are serviced from one pump supply.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSCA
Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. These valves may be used to accurately control two or more
cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDA
Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. These valves may be used to accurately control two or more
cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSEA
Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. These valves may be used to accurately control two or more
cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFA
Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. These valves may be used to accurately control two or more
cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSAA
High accuracy, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves may be used to accurately control
two or more cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSBA
Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. These valves may be used to accurately control two or more
cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDG
High accuracy, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves may be used to accurately control
two or more cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSEG
High accuracy, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves may be used to accurately control
two or more cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFG
High accuracy, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves may be used to accurately control
two or more cylinders or hydraulic motors where bidirectional operation is required.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSCH
High-capacity, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves have approximate 15% greater
capacity than standard closed-center divider/combiners and are designed for use in tractive drive systems. Note:
Accuracy on these cartridges is not equivalent to the accuracy of standard closed-center divider/combiners.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDH
High-capacity, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves have approximate 15% greater
capacity than standard closed-center divider/combiners and are designed for use in tractive drive systems. Note:
Accuracy on these cartridges is not equivalent to the accuracy of standard closed-center divider/combiners.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSEH
High-capacity, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves have approximate 15% greater
capacity than standard closed-center divider/combiners and are designed for use in tractive drive systems. Note:
Accuracy on these cartridges is not equivalent to the accuracy of standard closed-center divider/combiners.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFH
High-capacity, closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. These valves have approximate 15% greater
capacity than standard closed-center divider/combiners and are designed for use in tractive drive systems. Note:
Accuracy on these cartridges is not equivalent to the accuracy of standard closed-center divider/combiners.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSCS
Synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be used to allow
two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first cylinder has reached
the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second cylinder until it also
reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDS
Synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be used to allow
two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first cylinder has reached
the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second cylinder until it also
reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSES
Synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be used to allow
two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first cylinder has reached
the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second cylinder until it also
reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFS
Synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be used to allow
two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first cylinder has reached
the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second cylinder until it also
reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSAS
High accuracy, synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be
used to allow two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first
cylinder has reached the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second
cylinder until it also reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSBS
Synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one
direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be used to allow
two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first cylinder has reached
the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second cylinder until it also
reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSDR
High accuracy, synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be
used to allow two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first
cylinder has reached the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second
cylinder until it also reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSER
High accuracy, synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be
used to allow two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first
cylinder has reached the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second
cylinder until it also reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/FSFR
High accuracy, synchronizing flow divider/combiners are sliding-spool, pressure-compensated devices used to split
flow in one direction and combine flow in the opposite direction. With a sychronizing feature, these valves can be
used to allow two hydraulic cylinders to fully stroke and synchronize at the end of the stroke. When the first
cylinder has reached the end of its stroke, a pressure-compensated, reduced flow is metered to or from the second
cylinder until it also reaches the end of its stroke.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRBC
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRDC
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRFC
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRHC
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRJC
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRBA
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRDA
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRFA
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRHA
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRJA
Normally closed modulating elements with an internal orifice between port 1 and port 3 can be used as a main-
stage relief valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRDS
A normally closed modulating element, used as a bypass compensator, ensures a constant pressure drop across
an external orifice to create a pressure compensated flow control. The resulting flow remains constant regardless of
variations in upstream or downstream pressure.
A ball shuttle connects the after orifice signal from the higher of port 3 or 4 to the pilot area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPBC
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPDC
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPFC
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPFCL
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPHC
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPJC
Normally open modulating elements without an internal orifice act as a restrictive compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPBA
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPDA
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPFA
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPHA
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LPJA
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
These normally open modulating elements with an internal orifice between port 1 and port 3 can be used as a
main-stage reducing valve. The valve can be controlled remotely using a pilot relief or pilot solenoid valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
NOTES Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
sunhydraulics.com/model/LPDS
A normally open modulating element, used as a restrictive compensator, ensures a constant pressure drop across
an external orifice to create a pressure compensated flow control. The resulting flow remains constant regardless of
variations in upstream or downstream pressure.
A ball shuttle connects the after orifice signal from the higher of port 3 or 4 to the pilot area.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHDT
These bi-directional, normally open, modulating elements used with an external orifice, create a bi-directional,
pressure compensated flow control.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHFT
These bi-directional, normally open, modulating elements used with an external orifice, create a bi-directional,
pressure compensated flow control.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHHT
These bi-directional, normally open, modulating elements used with an external orifice, create a bi-directional,
pressure compensated flow control.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHDA
Bypass/restrictive modulating elements, when combined with an external orifice, create a bypass/restrictive flow
control. Input flow (port 3) is directed to the priority or control flow at port 2. Once the priority requirements are met,
excess flow is bypassed out port 4. The after-orifice signal is connected to port 1. The before-orifice design allows
both pressure and flow to be controlled on the priority side of the circuit regardless of pressure in the bypass circuit.
These valves work equally well in either closed or open center systems. Their main use is to allow after-market
accessories to be driven off the host machine's hydraulic system without adding an additional pump.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHFA
Bypass/restrictive modulating elements, when combined with an external orifice, create a bypass/restrictive flow
control. Input flow (port 3) is directed to the priority or control flow at port 2. Once the priority requirements are met,
excess flow is bypassed out port 4. The after-orifice signal is connected to port 1. The before-orifice design allows
both pressure and flow to be controlled on the priority side of the circuit regardless of pressure in the bypass circuit.
These valves work equally well in either closed or open center systems. Their main use is to allow after-market
accessories to be driven off the host machine's hydraulic system without adding an additional pump.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHHA
Bypass/restrictive modulating elements, when combined with an external orifice, create a bypass/restrictive flow
control. Input flow (port 3) is directed to the priority or control flow at port 2. Once the priority requirements are met,
excess flow is bypassed out port 4. The after-orifice signal is connected to port 1. The before-orifice design allows
both pressure and flow to be controlled on the priority side of the circuit regardless of pressure in the bypass circuit.
These valves work equally well in either closed or open center systems. Their main use is to allow after-market
accessories to be driven off the host machine's hydraulic system without adding an additional pump.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LHJA
Bypass/restrictive modulating elements, when combined with an external orifice, create a bypass/restrictive flow
control. Input flow (port 3) is directed to the priority or control flow at port 2. Once the priority requirements are met,
excess flow is bypassed out port 4. The after-orifice signal is connected to port 1. The before-orifice design allows
both pressure and flow to be controlled on the priority side of the circuit regardless of pressure in the bypass circuit.
These valves work equally well in either closed or open center systems. Their main use is to allow after-market
accessories to be driven off the host machine's hydraulic system without adding an additional pump.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/RVBB
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/RVCB
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/RVEB
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/RVGB
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/RVIB
Three-port normally closed modulating elements with relief provide two functions when combined with an external
orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the
external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure
rises to the valve setting, the valve operates as a normal relief valve.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
sunhydraulics.com/model/LRFCL
Normally closed modulating elements without an internal orifice act as a bypass compensator to maintain a
constant pressure drop across an orifice, regardless of variations in upstream or downstream pressure.
TECHNICAL DATA NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
www.sunhydraulics.com
Sun Hydraulics Headquarters Sun Hydraulics Limited Sun Hydraulik GmbH Sun Hydraulics Corp. (India)
Sarasota, Florida USA Coventry, England Erkelenz, Germany Bangalore, India
+1 941 362 1200 +44 2476 217 400 +49 2431 80910 +91 8028 456325
sales@sunuk.com sales@sunhydraulik.de sunindiainfo@sunhydraulics.com
Custom Fluidpower Pty Ltd
(A Sun Hydraulics Company) Sun Hydraulics Korea Corp. Sun Hydraulics China Co. Ltd. Sun Hydraulics Corp. (S.America)
Newcastle, Australia Incheon, Korea Shanghai, P.R. China Rosario, Argentina
+61 02 4953 5777 +82 3281 31350 +86 2162 375885 +54 9 341 584 3075
sales@custom.com.au sales@sunhydraulics.co.kr sunchinainfo@sunhydraulics.com ventas@sunhydraulics.com