Product Lineup RZF series RZA series

Cooling only
50 60 71 100 125 140
CEILING MOUNTED
CASSETTE TYPE Page
Round Flow 17
Indoor unit FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM
COMPACT MULTI FLOW
CEILING MOUNTED Page
CASSETTE TYPE
Indoor unit FFF50BV1 FFF60BV1 31
Outdoor unit RZF50CV2V RZF60CV2V
DUCT CONNECTION
MIDDLE STATIC Page
PRESSURE TYPE
Indoor unit FBA50BVMA(9) FBA60BVMA (9) FBA71BVMA(9) FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9) 33
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM
CEILING MOUNTED
SLIM DUCT TYPE Page
Indoor unit FDF50BV1 FDF60BV1 35
Outdoor unit RZF50CV2V RZF60CV2V
FLOOR STANDING TYPE
Page
Indoor unit FVA50AMVM FVA60AMVM FVA71AMVM FVA100AMVM FVA125AMVM FVA140AMVM 41
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM
CEILING SUSPENDED TYPE
Page
Indoor unit FHA50BVMV FHA60BVMV FHA71BVMV FHA100BVMV FHA125BVMA FHA140BVMA 43
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM

OUTDOOR UNIT

Page
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF71CYM RZF100CVM RZF100CYM RZF125CVM RZF125CYM RZF140CVM RZF140CYM
45
1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase,
Power supply 1 phase, 220V, 50Hz 1 phase, 220V, 50Hz 380-415 / 380V, 220-240 / 220-230V, 380-415 / 380V, 220-240 / 220-230V, 380-415 / 380V, 220-240 / 220-230V, 380-415 / 380V,
220V, 50Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz

Heat Pump
50 60 71 100 125 140
CEILING MOUNTED
CASSETTE TYPE Page
Round Flow 17
Indoor unit FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM
Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA100DY1 RZA125DV1 RZA125DY1 RZA140DV1 RZA140DY1
DUCT CONNECTION
MIDDLE STATIC Page
PRESSURE TYPE
Indoor unit FBA50BVMA(9) FBA60BVMA(9) FBA71BVMA(9) FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9) 33
Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA100DY1 RZA125DV1 RZA125DY1 RZA140DV1 RZA140DY1
FLOOR STANDING TYPE
Page
Indoor unit FVA50AMVM FVA60AMVM FVA71AMVM FVA100AMVM FVA125AMVM FVA140AMVM 41
Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA100DY1 RZA125DV1 RZA125DY1 RZA140DV1 RZA140DY1
CEILING SUSPENDED TYPE
Page
Indoor unit FHA50BVMV FHA60BVMV FHA71BVMV FHA100BVMV FHA125BVMA FHA140BVMA 43
Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA100DY1 RZA125DV1 RZA125DY1 RZA140DV1 RZA140DY1

OUTDOOR UNIT
NEW Page
Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA100DY1 RZA125DV1 RZA125DY1 RZA140DV1 RZA140DY1 45
Power supply 1 phase, 220V, 50Hz 1 phase, 220V, 50Hz 1 phase, 220-240V, 50Hz 1 phase, 220-240V, 50Hz 3 phase, 380-415V, 50Hz 1 phase, 220-240V, 50Hz 3 phase, 380-415V, 50Hz 1 phase, 220-240V, 50Hz 3 phase, 380-415V, 50Hz

5 6
Product Lineup RZFC series

Cooling only
40 50 60 71 85 100 125 140
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Page
17

Indoor unit FCFC40DVM FCFC50DVM FCFC60DVM FCFC71DVM FCFC85DVM FCFC100DVM FCFC125DVM FCFC140DVM
Outdoor unit RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC71DY1 RZFC85DVM RZFC85DY1 RZFC100DVM RZFC100DY1 RZFC125DY1 RZFC140DY1

DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
Page
33

Indoor unit FBFC40DVM(9) FBFC50DVM(9) FBFC60DVM(9) FBFC71DVM(9) FBFC85DVM(9) FBFC100DVM(9) FBFC125DVM(9) FBFC140DVM(9)
Outdoor unit RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC71DY1 RZFC85DVM RZFC85DY1 RZFC100DVM RZFC100DY1 RZFC125DY1 RZFC140DY1

DUCT CONNECTION
LOW STATIC PRESSURE
WIDTH COMPACT TYPE
Page
37

Indoor unit FDBF40DV1 FDBF50DV1 FDBF60DV1 FDBF71DV1 FDBF85DV1


Outdoor unit RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC71DY1 RZFC85DVM RZFC85DY1

DUCT CONNECTION
LOW STATIC PRESSURE
HEIGHT COMPACT TYPE
Page
39

Indoor unit FDLF40DV1 FDLF50DV1 FDLF60DV1 FDLF71DV1 FDLF85DV1


Outdoor unit RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC71DY1 RZFC85DVM RZFC85DY1

OUTDOOR UNIT

Page
45
Outdoor unit RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC71DY1 RZFC85DVM RZFC85DY1 RZFC100DVM RZFC100DY1 RZFC125DY1 RZFC140DY1

1 phase, 1 phase, 1 phase, 1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase,


220-240 / 3 phase, 3 phase,
Power supply 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 380-415V, 220-240 / 380-415V, 380-415V,
50 / 60Hz 50 / 60Hz 50 / 60Hz 220-230V, 220-230V, 220-230V, 380-415V, 50Hz 380-415V, 50Hz
50 / 60Hz 50Hz 50 / 60Hz 50Hz 50 / 60Hz 50Hz

7 8
OUTDOOR UNIT

Compact Outdoor Unit


Reuse of Existing Piping: Refrigerant Pipe Size Table RZF series
RZA series
Existing pipe size (Liquid / Gas) 6.4 / 6.4 / 9.5 / 9.5 / 9.5 / 12.7 / 12.7 / Level Design pressure
19.1 15.9 19.1 difference (High pressure)
RZF Outdoor Unit 12.7 15.9 12.7 15.9

series RZF50CV2V RZF


Condition
9.5 / 15.9 Max. piping length 10m 10m 50m 50m ------- 25m -------
RZF60CV2V RZF71CYM RZF125CVM / YM 50-71CV2V
Cooling Chargeless pipng length 10m 10m 30m 30m ------- 15m ------- Max.
only RZF71CV2V RZF100CVM / YM RZF140CVM / YM 4.15MPa
Condition 30m
RZF
71CYM 9.5 / 15.9 Max. piping length 10m 10m 50m 50m 50m 25m 25m
100-140C Chargeless pipng length 10m 10m 30m 30m 30m 15m 15m The allowable minimum piping length
is 5 m.
Existing pipe size (Liquid / Gas) 6.4 / 6.4 / 9.5 / 9.5 / 9.5 / 12.7 / 12.7 / Level Design pressure ・Refer to the installation manual for
Outdoor Unit 12.7 15.9 12.7 15.9 19.1 15.9 19.1 difference (High pressure) details other than those mentioned in
Condition the left table such as additional
RZA refrigerant charge amount.
9.5 / 15.9 Max. piping length 10m 10m 50m 50m ------- ------- -------
50/60D ・Clean the existing piping if its length
RZA Chargeless pipng length 10m 10m 30m 30m ------- ------- ------- Max. exceeds 30m.
4.15MPa
series Condition 30m
・Clean the existing piping if existing
RZA 9.5 / 15.9 10m 10m 75m 75m 75m 35m 35m piping length exceeds limit of
Max. piping length
71-140D chargeless piping length to perform
Chargeless pipng length 10m 10m 30m 30m 30m 15m 15m pump-down refrigerant recovery.
RZA100DY1
RZA50DV2V RZA71DV1 RZA125DV1 / Y1 Standard pipe size Same condition with standard pipe Piping length and chargeless piping length are shortened
Heat
Pump RZA60DV2V RZA100DV1 RZA140DV1 / Y1 Piping length and chargeless piping length are much shortened Cooilng capacity is lowered (pay attention to piping length)
Reuse of existing piping is not allowed

Technology for energy efficiency


RZFC85DVM 4
RZFC
RZFC100DVM
series RZFC40DVM
The high efficiency compressor to achieve a high COP 2
RZFC50DVM RZFC71DY1
Cooling
RZFC60DVM RZFC85DY1 RZFC125DY1 1 Compressor equiped with reluctance DC motor
only RZFC71DVM RZFC100DY1 RZFC140DY1 3
Daikin DC Inverter models are equipped with the reluctance DC motor for compressor.
The reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and 1
reluctance torque*2.
Easy Installation and Maintenance This motor can save energy because it generates more power with a smaller electric
power than an AC or previous DC motor.
Swing compressor
4-direction piping offers greater layout Facilitates pump down (Refrigerant recovery function) Reluctance DC Motor Reluctance
DC motor High efficiency during partial
freedom (RZF125/140, RZA71-140, RZFC125/140)

Motor efficiency
A pump-down switch is provided to make it easier to collect load operation.
refrigerant if the unit is to be moved or layout modified. DC motor *1. A neodymium magnet
The outer panel for the piping connection part of the front, More than 20%
is approximately 10
Energy savings is Swing bushing
*Pump-down function is available for pre-charged refrigerant amount. Note: times stronger than a
right side and backside can be removed and is easier for Data are based standard ferrite realised,
Refrigerant gas
*Although pumping-down operation allows most of the refrigerant to AC motor
post-installation piping work. be recovered in a short period of time, some refrigerant will remain
on studies magnet. eliminating the
conducted under *2. The torque created by friction and the
inside the indoor unit and refrigerant piping. Rotational speed controlled the change in power leakage of
Using a refrigerant recovery machine, recover remaining refrigerant
Removable part of bottom
Small load Large load conditions at a between the iron and
from the stop valve service port until the pressure falls to 0.09 MPa.
Low capacity High capacity
Daikin laboratory. magnet parts. refrigerant gas. Piston by incorporated
blade and roller.
(gauge pressure:-0.011MPa) or less.
frame makes the piping 2 Refrigerant cooling Fan
3
work easier Separation Low gas pressure detection function (RZF100-140CVM, RZF71-140CYM, RZA71-140D, RZFC71-140DY1) V-cut Propeller Fan (RZF50-100, RZA50/60, RZFC40-100)
(RZF125/140, RZA71-140, RZFC125/140) available
Effective gas monitoring reduces the labor required Daikin’s unique refrigerant Through use of a V-cut propeller fan that imitates the
for operation, maintenance, and repairs. cooling system exhibits efficiency of the swan, a migratory bird, airflow becomes
high cooling capacity smooth and loss is reduced.
even during high outdoor
temperatures.
Night Quiet Operation Mode RZF series RZA series Refrigerant cooling helps protect Imitating the
V-cut performance
the printed circuit board and propeller fan of the swan
The automatic night quiet mode will initiate 8 hours after maintains high cooling capacity
Sound pressure level1 (dB(A)) even during high outdoor
the peak temperature is reached in the daytime, and temperatures.
Rated
normal operation will resume 10 hours after that. Night Quiet
Mode
Peak outdoor temperature
Cooling Heating 4 High condensing capacity by micro channel heat exchanger RZF series RZFC series
50-71C 48 ------ 44
Reduced wind resistance
Capacity (%)

100C 49 ------ 45 The flattening of the heat exchanger tubes improves the flow of air and increases heat exchange efficiency.
100 RZF Reducing noise will
125C 52 ------ 45 reduce capacity slightly. Conventional tube and fin coil Micro channel coil
Conventional heat Micro channel
exchanger heat exchanger
8 hours 140C 54 ------ 45
50 10 hours Note : The diameter of the refrigerant
50-60D 47 49 43 1
Anechoic chamber The diameter of the Flat, multi-hole channel(holes where refrigerant
Load (%)

conversion value, refrigerant channel aluminium heat flows) is approx.1mm.


71D 48 50 44 (holes where
0 measured according to JIS exchanger tubes
100DV1 49 53 45 refrigerant flows) Approx.
48 parameters and criteria. is approx. 7mm
RZA 7mm
Sound (dB(A))

Rated Approx.
Note : 100DY1 48 50 44 During operation these
1mm
Operation

Quiet mode Utilizing flat, multi-hole heat exchanger tubes


44 Quiet mode Daikin date for RZF71C 125D 49 51 45 values are somewhat
increases the heat exchange area and realizes
Operating sound about higher owing to ambient Flow of refrigerant Flow of refrigerant energy savings.
8:00 12:00 16:00 20:00 0:00 4:00 8:00 4 dB quieter
140D 53 56 49 conditions.

45 46
SPECIFICATIONS RZF series

CEILING MOUNTED CASSETTE TYPE <Round Flow> (1 Phase) Cooling only COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE (1 Phase) Cooling only
50 60 71 100 125 140 50 60
Indoor unit FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM Indoor unit FFF50BV1 FFF60BV1
Model Model
Name Outdoor unit Name Outdoor unit
RZF50CV2V RZF60CV2V RZF71CV2V RZF100CVM RZF125CVM RZF140CVM RZF50CV2V RZF60CV2V
Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240 / 220-230V, 50 / 60Hz Power supply Outdoor unit 1 Phase, 220V, 50Hz
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0 Cooling Capacity 1,2 5.0 6.0
Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5) Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3)
17,100 20,500 24,200 34,100 42,700 47,800 17,100 20,500
Btu/h (7,800-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) Btu/h (7,800-19,100) (8,900-21,500)
Power consumption Cooling 1 kW 1.14 1.53 1.93 2.97 4.18 5.47 Power consumption Cooling 1 kW 1.51 2.00
COP kW/kW 4.39 3.92 3.68 3.37 2.99 2.56 COP kW/kW 3.31 3.00
CSPF kWh/kWh 6.60 6.31 6.17 5.50 5.15 5.00 CSPF kWh/kWh 4.96 4.73
Indoor unit Colour Unit ---------- Indoor unit Colour Unit ----------
Decoration panel Fresh white Decoration panel White
Airflow rate 3
m /min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0 Airflow rate (H/L) m /min
3
15.0 / 10.0
(H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741 cfm 530 / 353
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5 Sound pressure level 3 (H/L) dB(A) 41 / 32
Dimensions Unit mm 256X840X840 298X840X840 Dimensions Unit mm 260(286*)X575X575 (*Include control box)
(HXWXD) Decoration panel mm 50X950X950 (HXWXD) Decoration panel mm 55X700X700
Machine Unit kg 22 24 Machine Unit kg 17.5
weight Decoration panel kg 5.5 weight Decoration panel kg 2.7
Certified Operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Micro channel unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.3 1.6 2.4 Motor output kW 1.3
Refrigerant charge (R32) kg 1.2 (Charged for 30 m) 1.3 (Charged for 30 m) 1.9 (Charged for 30 m) Refrigerant charge (R32) kg 1.2 (Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54 Sound Cooling dB(A) 48
pressure level 3 Night quiet mode pressure level 3
dB(A) 44 45 Night quiet mode dB(A) 44
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320 Dimensions (HXWXD) mm 595X845X300
Machine weight kg 41 48 64 Machine weight kg 41
Certified Operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole) Outdoor unit mm 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

CEILING MOUNTED CASSETTE TYPE <Round Flow> (3 Phase) Cooling only DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (1 Phase) Cooling only
71 100 125 140 50 60 71 100 125 140
Indoor unit FCF71CVM FCF100CVM FCF125CVM FCF140CVM Indoor unit FBA50BVMA(9) FBA60BVMA(9) FBA71BVMA(9) FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9)
Model Model
Name Outdoor unit Name Outdoor unit
RZF71CYM RZF100CYM RZF125CYM RZF140CYM RZF50CV2V RZF60CV2V RZF71CV2V RZF100CVM RZF125CVM RZF140CVM
Power supply Outdoor unit 3 Phase, 380-415 / 380V, 50 / 60Hz Power supply Indoor unit 1 Phase, 220-240V / 220-230V, 50 / 60Hz
Cooling Capacity 1,2 7.1 10.0 12.5 14.0 Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240 / 220-230V, 50 / 60Hz
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) 17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (7,800-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling 1 kW 1.93 2.97 4.18 5.47
COP kW/kW 3.68 3.37 2.99 2.56 Power consumption Cooling 1 kW 1.35 1.64 2.15 3.01 4.44 5.69
CSPF kWh/kWh 6.17 5.50 5.15 5.00 COP kW/kW 3.70 3.66 3.30 3.32 2.82 2.46
Indoor unit Colour Unit ---------- CSPF kWh/kWh 5.51 5.30 5.19 4.88 4.70 4.47
Decoration panel Fresh white Indoor unit Colour ----------
Airflow rate m3/min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0 Fan Airflow rate (H/M/L) m3/min 18.0 / 15.0 / 12.5 23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0
(H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741 cfm 635 / 530 / 441 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5 External static pressure 3
Pa Rated 50 (50-150)
Dimensions Unit mm 256X840X840 298X840X840 Sound pressure level 4 (H/M/L) dB(A) 35.0 / 33.0 / 31.0 38.0 / 35.0 / 33.0 38.0 / 35.5 / 33.0 40.0 / 37.5 / 35.0
(HXWXD) Decoration panel mm 50X950X950 Air filter 5 ----------
Machine Unit kg 22 24 Dimensions (HXWXD) mm 245X1000X800 245X1400X800
weight Decoration panel kg 5.5 Machine weight kg 37 47
Certified Operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Micro channel unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.6 2.4 Motor output kW 1.3 1.6 2.4
Refrigerant charge (R32) kg 1.3 (Charged for 30 m) 1.9 (Charged for 30 m) Refrigerant charge (R32) kg 1.2 (Charged for 30 m) 1.3 (Charged for 30 m) 1.9 (Charged for 30 m)
Sound Cooling dB(A) 48 49 52 54 Sound Cooling dB(A) 48 49 52 54
pressure level 3 pressure level 4
Night quiet mode dB(A) 44 45 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 695X930X350 990X940X320 Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Machine weight kg 48 64 Machine weight kg 41 48 64
Certified Operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 18.0 (Hole) 26.0 (Hole) Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping
Note : Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat. 2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 3
External static pressure is changeable in 11 stages by remote controller.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.

59 60
SPECIFICATIONS RZF series

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (3 Phase) Cooling only FLOOR STANDING TYPE (1 Phase) Cooling only
71 100 125 140 50 60 71 100 125 140
Indoor unit FBA71BVMA(9) FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9) Indoor unit FVA50AMVM FVA60AMVM FVA71AMVM FVA100AMVM FVA125AMVM FVA140AMVM
Model Model
Name Outdoor unit Name Outdoor unit
RZF71CYM RZF100CYM RZF125CYM RZF140CYM RZF50CV2V RZF60CV2V RZF71CV2V RZF100CVM RZF125CVM RZF140CVM
Power supply Indoor unit 1 Phase, 220-240V / 220-230V, 50 / 60Hz Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240 / 220-230V, 50 / 60Hz
Outdoor unit 3 Phase, 380-415 / 380V, 50 / 60Hz Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
Cooling Capacity 1,2 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5) 17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (7,800-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) Power consumption Cooling 1 kW 1.23 1.79 2.51 3.48 4.48 5.71
Power consumption Cooling 1 kW 2.15 3.01 4.44 5.69 COP kW/kW 4.07 3.35 2.83 2.87 2.79 2.45
COP kW/kW 3.30 3.32 2.82 2.46 CSPF kWh/kWh 6.03 4.86 4.46 4.19 4.67 4.18
CSPF kWh/kWh 5.19 4.88 4.70 4.47 Indoor unit Colour Fresh white
Indoor unit Colour ---------- Airflow rate m3/min 18 / 16 / 14 28 / 25 / 22 28 / 26 / 24 30 / 28 / 26
Fan Airflow rate (H/M/L) m /min
3
23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0 (H / M / L) cfm 635 / 565 / 494 988 / 883 / 777 988 / 918 / 847 1,059 / 988 / 918
cfm 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883 Sound pressure level (H / M / L)
3
dB(A) 43 / 41 / 38 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48
External static pressure 3 Pa Rated 50 (50-150) Dimensions (HXWXD) mm 1,850X600X270 1,850X600X350
Sound pressure level 4 (H/M/L) dB(A) 38.0 / 35.0 / 33.0 38.0 / 35.5 / 33.0 40.0 / 37.5 / 35.0 Machine weight kg 42 50
Air filter 5 ---------- Certified Operation range °CWB 14 to 25
Dimensions (HXWXD) mm 245X1000X800 245X1400X800 Outdoor Colour Ivory white
Machine weight kg 37 47 unit Coil Type Micro channel
Certified Operation range °CWB 14 to 25 Compressor Type Hermetically sealed swing type
Outdoor Colour Ivory white Motor output kW 1.30 1.60 2.40
unit Coil Type Micro channel Refrigerant charge (R32) kg 1.2 (Charged for 30 m) 1.3 (Charged for 30 m) 1.9 (Charged for 30 m)
Compressor Type Hermetically sealed swing type Sound Cooling dB(A) 48 49 52 54
pressure level 3
Motor output kW 1.6 2.4 Night quiet mode dB(A) 44 45
Refrigerant charge (R32) kg 1.3 (Charged for 30 m) 1.9 (Charged for 30 m) Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320
Sound Cooling dB(A) 48 49 52 54 Machine weight kg 41 48 64
pressure level 4
Night quiet mode dB(A) 44 45 Certified Operation range °CDB 21 to 46
Dimensions (HXWXD) mm 695X930X350 990X940X320 Piping Liquid (Flare) mm 9.5
Machine weight kg 48 64 connections Gas (Flare) mm 15.9
Certified Operation range °CDB 21 to 46 Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Piping Liquid (Flare) mm 9.5 Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole)
connections Gas (Flare) mm 15.9 Max. interunit piping length m 50 (Equivalent length 70)
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Max. installation level difference m 30
Outdoor unit mm 18.0 (Hole) 26.0 (Hole) Heat insulation Both liquid and gas piping
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.

CEILING MOUNTED SLIM DUCT TYPE (1 Phase) Cooling only FLOOR STANDING TYPE (3 Phase) Cooling only
50 60 71 100 125 140
Indoor unit FDF50BV1 FDF60BV1 Indoor unit FVA71AMVM FVA100AMVM FVA125AMVM FVA140AMVM
Model Model
Name Outdoor unit Name Outdoor unit
RZF50CV2V RZF60CV2V RZF71CYM RZF100CYM RZF125CYM RZF140CYM
Power supply Outdoor unit 1 Phase, 220V, 50Hz Power supply Outdoor unit 3 Phase, 380-415 / 380V, 50 / 60Hz
Cooling Capacity 1,2 5.0 6.0 Cooling Capacity 1,2 7.1 10.0 12.5 14.0
Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3) Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
17,100 20,500 24,200 34,100 42,700 47,800
Btu/h (7,800-19,100) (8,900-21,500) Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Power consumption Cooling 1
kW 1.51 1.98 Power consumption Cooling 1
kW 2.51 3.48 4.48 5.71
COP kW/kW 3.31 3.03 COP kW/kW 2.83 2.87 2.79 2.45
CSPF kWh/kWh 4.98 4.78 CSPF kWh/kWh 4.46 4.19 4.67 4.18
Indoor unit Colour Unit ---------- Indoor unit Colour Fresh white
Fan Airflow rate (H/L) m3/min 16.0 / 13.5 Airflow rate m3/min 18 / 16 / 14 28 / 25 / 22 28 / 26 / 24 30 / 28 / 26
cfm 565 / 477 (H / M / L) cfm 635 / 565 / 494 988 / 883 / 777 988 / 918 / 847 1,059 / 988 / 918
External static pressure Pa 40 Sound pressure level 3 (H / M / L) dB(A) 43 / 41 / 38 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48
Sound pressure level 3 (H/L) dB(A) 38 / 34 Dimensions (HXWXD) mm 1,850X600X270 1,850X600X350
Air filter Mould-proof air filter (Removable / Washable / Mould proof) Machine weight kg 42 50
Dimensions (HXWXD) mm 200X1100X620 Certified Operation range °CWB 14 to 25
Machine weight kg 30 Outdoor Colour Ivory white
Certified Operation range °CWB 14 to 25 unit Coil Type Micro channel
Outdoor Colour Ivory white Compressor Type Hermetically sealed swing type
unit Coil Type Micro channel Motor output kW 1.60 2.40
Compressor Type Hermetically sealed swing type Refrigerant charge (R32) kg 1.3 (Charged for 30 m) 1.9 (Charged for 30 m)
Motor output kW 1.3 Sound Cooling dB(A) 48 49 52 54
pressure level 3
Refrigerant charge (R32) kg 1.2 (Charged for 30 m) Night quiet mode dB(A) 44 45
Sound Cooling dB(A) 48 Dimensions (HXWXD) mm 695X930X350 990X940X320
pressure level 3
Night quiet mode dB(A) 44 Machine weight kg 48 64
Dimensions (HXWXD) mm 595X845X300 Certified Operation range °CDB 21 to 46
Machine weight kg 41 Piping Liquid (Flare) mm 9.5
Certified Operation range °CDB 21 to 46 connections Gas (Flare) mm 15.9
Piping Liquid (Flare) mm 9.5 Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
connections Gas (Flare) mm 15.9 Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26) Max. interunit piping length m 50 (Equivalent length 70)
Outdoor unit mm 26.0 (Hole) Max. installation level difference m 30
Max. interunit piping length m 50 (Equivalent length 70) Heat insulation Both liquid and gas piping
Max. installation level difference m 30 Note :
Heat insulation Both liquid and gas piping
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
Note : 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

61 62
SPECIFICATIONS RZF series SPECIFICATIONS RZA series

CEILING MOUNTED CASSETTE TYPE <Round Flow> (1 Phase) Heat Pump


CEILING SUSPENDED TYPE (1 Phase) Cooling only
50 60 71 100 125 140
50 60 71 100 125 140 Model Indoor unit FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM
Indoor unit FHA50BVMV FHA60BVMV FHA71BVMV FHA100BVMV FHA125BVMA FHA140BVMA Name Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA125DV1 RZA140DV1
Model
Name Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240V, 50Hz
Outdoor unit RZF50CV2V RZF60CV2V RZF71CV2V RZF100CVM RZF125CVM RZF140CVM
Cooling capacity 1,3 kW 5.0 (1.4-6.0) 6.0 (1.4-7.1) 7.1 (3.2-8.0) 10.0 (3.2-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0)
Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240 / 220-230V, 50 / 60Hz Rated (Min. - Max.) Btu/h 17,100 (4,800-20,500) 20,500 (4,800-24,200) 24,200 (10,900-27,300) 34,100 (10,900-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600)
Cooling Capacity 1,2 5.0 6.0 7.1 10.0 12.5 14.0 Heating capacity 2,3 kW 6.0 (1.4-7.1) 7.1 (1.4-8.0) 8.0 (3.5-9.0) 11.2 (3.5-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Rated (Min. - Max.) kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5) Rated (Min. - Max.) Btu/h 20,500 (4,800-24,200) 23,200 (4,800-27,300) 27,300 (12,000-30,700) 38,200 (11,900-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400)
17,100 20,500 24,200 34,100 42,700 47,800 Power consumption Cooling 1 1.11 1.49 1.90 3.06 3.52 4.21
Btu/h (7,800-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) kW
Heating 2 1.27 1.54 2.05 2.90 3.81 4.75
Power consumption Cooling 1 kW 1.20 1.53 2.30 3.24 4.29 5.40 COP Cooling 4.50 4.03 3.73 3.27 3.55 3.32
COP kW/kW 4.17 3.92 3.09 3.09 2.91 2.59 kW/kW
Heating 4.73 4.61 3.90 3.86 3.68 3.37
CSPF kWh/kWh 6.30 6.11 5.91 5.17 5.09 4.78 CSPF Cooling kWh/kWh 7.22 6.85 6.13 5.54 5.76 5.20
Indoor unit Colour White Indoor unit Colour Unit ----------
Airflow rate m3/min 15.0 / 13.5 / 12.0 / 11.0 / 10.0 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0 Decoration panel Fresh white
(H / HM / M / ML / L) cfm 530 / 477 / 424 / 388 / 353 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847 Airflow rate m3/min 23.0 / 21.0 / 18.5 / 16.0 / 13.5 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 37.0 / 36.0 / 35.0 / 33.5 / 32.0 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0 (H / HM / M / ML / L) cfm 812 / 741 / 653 / 565 / 477 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741
Dimensions (HXWXD) mm 235X960X690 235X1270X690 235X1590X690 Sound pressure level 4 (H / HM / M / ML / L) dB(A) 37.0 / 34.5 / 32.0 / 29.5 / 27.5 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5
Machine weight kg 25 32 38 Dimensions Unit mm 256X840X840 298X840X840
Certified Operation range °CWB 14 to 25 (HXWXD) Decoration panel mm 50X950X950
Outdoor Colour Ivory white Machine Unit kg 22 24
unit Coil Type Micro channel weight Decoration panel kg 5.5
Compressor Type Hermetically sealed swing type Certified Cooling °CWB 14 to 25
Motor output kW 1.3 1.6 2.4 Operation range Heating °CDB 15 to 27
Refrigerant charge (R32) kg 1.2 (Charged for 30 m) 1.3 (Charged for 30 m) 1.9 (Charged for 30 m) Outdoor Colour Ivory white
Sound Cooling dB(A) 48 49 52 54 unit Coil Type Cross fin coil
pressure level 3
Night quiet mode dB(A) 44 45 Compressor Type Hermetically sealed swing type
Dimensions (HXWXD) mm 595X845X300 695X930X350 990X940X320 Motor output kW 1.3 2.4 3.3
Machine weight kg 41 48 64 Refrigerant charge (R32) kg 1.7 (Charged for 30 m) 2.6 (Charged for 30 m) 3.75 (Charged for 30 m)
Certified Operation range °CDB 21 to 46 Sound Cooling / Heating dB(A) 47 / 49 48 / 50 49 / 53 49 / 51 53 / 56
Piping Liquid (Flare) mm 9.5 pressure level 4 Night quiet mode dB(A) 43 44 45 49
connections Gas (Flare) mm 15.9 Dimensions (HXWXD) mm 595X845X300 990X940X320 1,430X940X320
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26) Machine weight kg 45 69 93
Outdoor unit mm 26.0 (Hole) 18.0 (Hole) 26.0 (Hole) Certified Cooling °CDB -5 to 46
Max. interunit piping length m 50 (Equivalent length 70) Operation range Heating °CWB -15 to 15.5
Max. installation level difference m 30 Piping Liquid (Flare) mm 9.5
Heat insulation Both liquid and gas piping connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) 75 (Equivalent length 90)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

CEILING SUSPENDED TYPE (3 Phase) Cooling only CEILING MOUNTED CASSETTE TYPE <Round Flow> (3 Phase) Heat Pump
71 100 125 140 100 125 140
Indoor unit FHA71BVMV FHA100BVMV FHA125BVMA FHA140BVMA Model Indoor unit FCF100CVM FCF125CVM FCF140CVM
Model Name Outdoor unit RZA100DY1 RZA125DY1 RZA140DY1
Name Outdoor unit RZF71CYM RZF100CYM RZF125CYM RZF140CYM Power supply Outdoor unit 3 Phase, 380-4150V, 50Hz
Power supply Outdoor unit 3 Phase, 380-415 / 380V, 50 / 60Hz Cooling capacity 1,3 kW 10.0 (5.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0)
7.1 10.0 12.5 14.0 Rated (Min. - Max.) Btu/h 34,100 (17,100-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600)
Cooling Capacity 1,2
Rated (Min. - Max.) kW (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.5) Heating capacity 2,3 kW 11.2 (5.1-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Rated (Min. - Max.) Btu/h 38,200 (17,400-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400)
24,200 34,100 42,700 47,800
Btu/h (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,900) Power consumption Cooling 1 2.78 3.52 4.21
kW
Heating 2 2.71 3.81 4.75
Power consumption Cooling 1
kW 2.30 3.24 4.29 5.40
COP Cooling 3.60 3.55 3.32
COP kW/kW 3.09 3.09 2.91 2.59 kW/kW
Heating 4.14 3.68 3.37
CSPF kWh/kWh 5.91 5.17 5.09 4.78 CSPF Cooling kWh/kWh 5.91 5.76 5.20
Indoor unit Colour White Colour Unit ----------
Indoor unit
Airflow rate m3/min 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0 Decoration panel Fresh white
(H / HM / M / ML / L) cfm 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847 Airflow rate m3/min 34.5 / 31.0 / 27.5 / 24.0 / 20.0 36.5 / 33.0 / 29.0 / 25.0 / 21.0
Sound pressure level 3 (H / HM / M / ML / L) dB(A) 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0 (H / HM / M / ML / L) cfm 1,218 / 1,094 / 971 / 847 / 706 1,288 / 1,165 / 1,024 / 883 / 741
Dimensions (HXWXD) mm 235X1270X690 235X1590X690 Sound pressure level 4 (H / HM / M / ML / L) dB(A) 45.0 / 41.5 / 38.0 / 35.0 / 32.5 46.0 / 43.0 / 40.0 / 36.0 / 32.5
Machine weight kg 32 38 Dimensions Unit mm 298X840X840
Certified Operation range °CWB 14 to 25 (HXWXD) Decoration panel mm 50 950 950
X X

Ivory white Machine Unit kg 24


Outdoor Colour weight
unit Coil Type Micro channel Decoration panel kg 5.5
Certified Cooling °CWB 14 to 25
Compressor Type Hermetically sealed swing type
Operation range Heating °CDB 15 to 27
Motor output kW 1.6 2.4
Outdoor Colour Ivory white
Refrigerant charge (R32) kg 1.3 (Charged for 30 m) 1.9 (Charged for 30 m)
unit Coil Type Cross fin coil
Sound Cooling dB(A) 48 49 52 54
pressure level 3 Compressor Type Hermetically sealed swing type
Night quiet mode dB(A) 44 45 3.3
Motor output kW
Dimensions (HXWXD) mm 695X930X350 990X940X320 Refrigerant charge (R32) kg 3.75 (Charged for 30 m)
Machine weight kg 48 64 Sound Cooling / Heating dB(A) 48 / 50 49 / 51 53 / 56
Certified Operation range °CDB 21 to 46 pressure level 4 Night quiet mode dB(A) 44 45 49
Piping Liquid (Flare) mm 9.5 Dimensions (HXWXD) mm 1,430X940X320
connections Gas (Flare) mm 15.9 Machine weight kg 93
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26) Certified Cooling °CDB -5 to 46
Outdoor unit mm 18.0 (Hole) 26.0 (Hole) Operation range Heating °CWB -15 to 15.5
Max. interunit piping length m 50 (Equivalent length 70) Piping Liquid (Flare) mm 9.5
Max. installation level difference m 30 connections Gas (Flare) mm 15.9
Both liquid and gas piping Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Heat insulation
Outdoor unit mm 26.0 (Hole)
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). Max. interunit piping length m 75 (Equivalent length 90)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat. Max. installation level difference m 30
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. Heat insulation Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
3
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

63 64
SPECIFICATIONS RZA series

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (1 Phase) Heat Pump FLOOR STANDING TYPE (1 Phase) Heat Pump
50 60 71 100 125 140 50 60 71 100 125 140
Model Indoor unit FBA50BVMA(9) FBA60BVMA(9) FBA71BVMA(9) FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9) Model Indoor unit FVA50AMVM FVA60AMVM FVA71AMVM FVA100AMVM FVA125AMVM FVA140AMVM
Name Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA125DV1 RZA140DV1 Name Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA125DV1 RZA140DV1
Power supply Indoor unit 1 Phase, 220-240V / 220-230V, 50 / 60Hz Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240V, 50Hz
Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240V, 50Hz Cooling Capacity 1,3 kW 5.0 (1.4-6.0) 6.0 (1.4-7.1) 7.1 (3.2-8.0) 10.0 (3.2-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0)
Cooling Capacity 1,3 kW 5.0 (1.4-6.0) 6.0 (1.4-7.1) 7.1 (3.2-8.0) 10.0 (3.2-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) Rated (Min. - Max.) Btu/h 17,100 (4,800-20,500) 20,500 (4,800-24,200) 24,200 (10,900-27,300) 34,100 (10,900-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600)
Rated (Min. - Max.) Btu/h 17,100 (4,800-20,500) 20,500 (4,800-24,200) 24,200 (10,900-27,300) 34,100 (10,900-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600) Heating capacity 2,3 kW 6.0 (1.4-7.1) 7.1 (1.4-8.0) 8.0 (3.5-9.0) 11.2 (3.5-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Heating capacity 2,3 kW 6.0 (1.4-7.1) 7.1 (1.4-8.0) 8.0 (3.5-9.0) 11.2 (3.5-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0) Rated (Min. - Max.) Btu/h 20,500 (4,800-24,200) 23,200 (4,800-27,300) 27,300 (12,000-30,700) 38,200 (11,900-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400)
Rated (Min. - Max.) Btu/h 20,500 (4,800-24,200) 23,200 (4,800-27,300) 27,300 (12,000-30,700) 38,200 (11,900-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400) Power consumption Cooling 1 1.24 1.65 2.18 3.29 3.85 4.50
kW
Power consumption Cooling 1 1.23 1.64 2.00 3.17 3.74 4.27 Heating 2 1.50 1.96 2.49 3.36 4.22 5.26
kW
Heating 2 1.31 1.81 2.09 2.90 3.73 4.56 COP Cooling 4.04 3.63 3.25 3.04 3.25 3.11
kW/kW
COP Cooling 4.06 3.66 3.56 3.15 3.34 3.28 Heating 3.99 3.62 3.21 3.33 3.31 3.04
kW/kW
Heating 4.58 3.92 3.82 3.86 3.75 3.51 CSPF Cooling kWh/kWh 6.04 5.41 5.32 5.27 5.43 5.02
CSPF Cooling kWh/kWh 6.28 5.92 5.71 5.33 5.30 4.93 Indoor unit Colour Fresh white
Indoor unit Colour ---------- Airflow rate (H / M / L) m3/min 18 / 16 / 14 28 / 25 / 22 28 / 26 / 24 30 / 28 / 26
Fan Airflow rate (H / M / L) m3/min 18.0 / 15.0 / 12.5 23.0 / 19.5 / 16.0 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0 cfm 635 / 565 / 494 988 / 883 / 777 988 / 918 / 847 1,059 / 988 / 918
cfm 635 / 530 / 441 812 / 688 / 565 1,130 / 953 / 794 1,271 / 1,077 / 883 Sound pressure level 4 (H / M / L) dB(A) 43 / 41 / 38 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48
External static pressure 4 Pa Rated 50 (50-150) Dimensions (HXWXD) mm 1,850X600X270 1,850X600X350
Sound pressure level 5 (H/M/L) dB(A) 35.0 / 33.0 / 31.0 38.0 / 35.0 / 33.0 38.0 / 35.5 / 33.0 40.0 / 37.5 / 35.0 Machine weight kg 42 50
Air filter 6 ---------- Certified Cooling °CWB 14 to 25
Dimensions (HXWXD) mm 245X1000X800 245X1400X800 Operation range Heating °CDB 15 to 27
Machine weight kg 37 47 Outdoor Colour Ivory white
Certified Cooling °CWB 14 to 25 unit Coil Type Cross fin coil
Operation range Heating °CDB 15 to 27 Compressor Type Hermetically sealed swing type
Outdoor Colour Ivory white Motor output kW 1.3 2.4 3.3
unit Coil Type Cross fin coil Refrigerant charge (R32) kg 1.7 (Charged for 30 m) 2.6 (Charged for 30 m) 3.75 (Charged for 30 m)
Compressor Type Hermetically sealed swing type Sound Cooling / Heating dB(A) 47 / 49 48 / 50 49 / 53 49 / 51 53 / 56
pressure level 4
Motor output kW 1.3 2.4 3.3 Night quiet mode dB(A) 43 44 45 49
Refrigerant charge (R32) kg 1.7 (Charged for 30 m) 2.6 (Charged for 30 m) 3.75 (Charged for 30 m) Dimensions (HXWXD) mm 595X845X300 990X940X320 1,430X940X320
Sound Cooling / Heating dB(A) 47 / 49 48 / 50 49 / 53 49 / 51 53 / 56 Machine weight kg 45 69 93
pressure level 5
Night quiet mode dB(A) 43 44 45 49 Certified Cooling °CDB -5 to 46
Dimensions (HXWXD) mm 595X845X300 990X940X320 1,430X940X320 Operation range Heating °CWB -15 to 15.5
Machine weight kg 45 69 93 Piping Liquid (Flare) mm 9.5
Cooling °CDB -5 to 46 connections Gas (Flare) mm 15.9
Certified
Operation range Heating °CWB -15 to 15.5 Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Piping Liquid (Flare) mm 9.5 Outdoor unit mm 26.0 (Hole)
connections Gas (Flare) mm 15.9 Max. interunit piping length m 50 (Equivalent length 70) 75 (Equivalent length 90)
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Max. installation level difference m 30
Outdoor unit mm 26.0 (Hole) Heat insulation Both liquid and gas piping
Max. interunit piping length m 50 (Equivalent length 70) 75 (Equivalent length 90)
Max. installation level difference m 30
Heat insulation Both liquid and gas piping

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (3 Phase) Heat Pump FLOOR STANDING TYPE (3 Phase) Heat Pump
100 125 140 100 125 140
Model Indoor unit FBA100BVMA(9) FBA125BVMA(9) FBA140BVMA(9) Model Indoor unit FVA100AMVM FVA125AMVM FVA140AMVM
Name Outdoor unit RZA100DY1 RZA125DY1 RZA140DY1 Name Outdoor unit RZA100DY1 RZA125DY1 RZA140DY1
Power supply Indoor unit 1 Phase, 220-240V / 220-230V, 50 / 60Hz Power supply Outdoor unit 3 Phase, 380-415V, 50Hz
Outdoor unit 3 Phase, 380-415V, 50Hz
Cooling Capacity 1,3 kW 10.0 (5.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0)
Cooling Capacity 1,3 kW 10.0 (5.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0)
Rated (Min. - Max.) Btu/h 34,100 (17,100-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600)
Rated (Min. - Max.) Btu/h 34,100 (17,100-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600)
Heating capacity 2,3 kW 11.2 (5.1-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0) Heating capacity 2,3 kW 11.2 (5.1-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Rated (Min. - Max.) Rated (Min. - Max.) Btu/h 38,200 (17,400-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400)
Btu/h 38,200 (17,400-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400)
Power consumption Cooling 1 2.78 3.74 4.27 Power consumption Cooling 1
3.00 3.85 4.50
kW kW
Heating 2 2.69 3.73 4.56 Heating 2 3.16 4.22 5.26
COP Cooling 3.60 3.34 3.28 COP Cooling 3.33 3.25 3.11
kW/kW kW/kW
Heating 4.16 3.75 3.51 Heating 3.55 3.31 3.04
CSPF Cooling kWh/kWh 5.75 5.30 4.93 CSPF Cooling kWh/kWh 5.60 5.43 5.02
Indoor unit Colour ---------- Colour
Indoor unit Fresh white
Fan Airflow rate (H / M / L) m3/min 32.0 / 27.0 / 22.5 36.0 / 30.5 / 25.0
Airflow rate (H / M / L) m3/min 28 / 25 / 22 28 / 26 / 24 30 / 28 / 26
cfm 1,130 / 953 / 794 1,271 / 1,077 / 883
External static pressure 4 Pa Rated 50 (50-150) cfm 988 / 883 / 777 988 / 918 / 847 1,059 / 988 / 918
Sound pressure level 5 (H/M/L) dB(A) 38.0 / 35.5 / 33.0 40.0 / 37.5 / 35.0 Sound pressure level 4 (H / M / L) dB(A) 50 / 47 / 44 51 / 48 / 46 53 / 51 / 48
Air filter 6 ---------- Dimensions (HXWXD) mm 1,850X600X350
Dimensions (HXWXD) mm 245X1400X800 Machine weight kg 50
Machine weight kg 47 Certified Cooling °CWB 14 to 25
Certified Cooling °CWB 14 to 25 Operation range Heating °CDB 15 to 27
Operation range Heating °CDB 15 to 27 Outdoor Colour Ivory white
Outdoor Colour Ivory white unit Coil Type Cross fin coil
unit Coil Type Cross fin coil
Compressor Type Hermetically sealed swing type
Compressor Type Hermetically sealed swing type
Motor output kW Motor output kW 3.3
3.3
Refrigerant charge (R32) kg 3.75 (Charged for 30 m) Refrigerant charge (R32) kg 3.75 (Charged for 30 m)
Sound Cooling / Heating dB(A) 48 / 50 49 / 51 53 / 56 Sound Cooling / Heating dB(A) 48 / 50 49 / 51 53 / 56
pressure level Night quiet mode
5 pressure level 4
dB(A) 44 45 49 Night quiet mode dB(A) 44 45 49
Dimensions (HXWXD) mm 1,430X940X320 Dimensions (HXWXD) mm 1,430X940X320
Machine weight kg 93 Machine weight kg 93
Certified Cooling °CDB -5 to 46 Cooling °CDB -5 to 46
Certified
Operation range Heating °CWB -15 to 15.5 Operation range Heating °CWB -15 to 15.5
Piping Liquid (Flare) mm 9.5
connections Gas (Flare) Piping Liquid (Flare) mm 9.5
mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 26.0 (Hole) Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Max. interunit piping length m 75 (Equivalent length 90) Outdoor unit mm 26.0 (Hole)
Max. installation level difference m 30 Max. interunit piping length m 75 (Equivalent length 90)
Heat insulation Both liquid and gas piping Max. installation level difference m 30
Note : Heat insulation Both liquid and gas piping
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). Note :
3
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
4
External static pressure is changeable in 11 stages by remote controller. 2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
5
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 3
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
6
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more. 4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

65 66
SPECIFICATIONS RZA series SPECIFICATIONS RZFC series

CEILING SUSPENDED TYPE (1 Phase) Heat Pump CEILING MOUNTED CASSETTE TYPE <Round Flow> (1 Phase) Cooling only
50 60 71 100 125 140 40 50 60 71 85 100
Model Indoor unit FHA50BVMV FHA60BVMV FHA71BVMV FHA100BVMV FHA125BVMA FHA140BVMA Indoor unit FCFC40DVM FCFC50DVM FCFC60DVM FCFC71DVM FCFC85DVM FCFC100DVM
Name Outdoor unit RZA50DV2V RZA60DV2V RZA71DV1 RZA100DV1 RZA125DV1 RZA140DV1 Model
Name Outdoor unit
Power supply Outdoor unit 1 Phase, 220V, 50Hz 1 Phase, 220-240V, 50Hz RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC85DVM RZFC100DVM
Cooling Capacity 1,3 kW 5.0 (1.4-6.0) 6.0 (1.4-7.1) 7.1 (3.2-8.0) 10.0 (3.2-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) Power supply Outdoor unit 1 Phase, 220–240 / 220-230V, 50 / 60Hz
Rated (Min. - Max.) Btu/h 17,100 (4,800-20,500) 20,500 (4,800-24,200) 24,200 (10,900-27,300) 34,100 (10,900-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600) Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)
Heating capacity 2,3 kW 6.0 (1.4-7.1) 7.1 (1.4-8.0) 8.0 (3.5-9.0) 11.2 (3.5-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Rated (Min. - Max.) Btu/h 20,500 (4,800-24,200) 23,200 (4,800-27,300) 27,300 (12,000-30,700) 38,200 (11,900-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400) 13,600 17,100 20,500 24,200 29,000 34,100
Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) (17,100-38,200)
Power consumption Cooling 1 1.30 1.66 2.09 3.22 3.62 4.48
kW
Heating 2 1.52 2.07 2.42 3.00 4.05 4.75 Power consumption Cooling 1 kW 1.26 1.57 1.89 2.38 2.85 3.35
COP Cooling 3.85 3.61 3.40 3.11 3.45 3.13 COP kW/kW 3.18 2.98
kW/kW
Heating 3.95 3.43 3.30 3.73 3.46 3.37 CSPF kWh/kWh 5.13 4.90 4.67
CSPF Cooling kWh/kWh 6.12 5.65 5.61 5.37 5.62 5.02 Indoor unit Colour Unit White
Indoor unit Colour White Decoration panel Fresh white
Airflow rate 3
m /min 15.0 / 13.5 / 12.0 / 11.0 / 10.0 20.5 / 18.8 / 17.0 / 15.5 / 14.0 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0 Airflow rate m /min3
19 / 14 / 11 23 / 18 / 13 34 / 27 / 20
(H / HM / M / ML / L) cfm 530 / 477 / 424 / 388 / 353 724 / 664 / 600 / 547 / 494 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847 (H / M / L) cfm 671 / 494 / 388 812 / 635 / 459 1,200 / 953 / 706
Sound pressure level 4 (H / HM / M / ML / L) dB(A) 37.0 / 36.0 / 35.0 / 33.5 / 32.0 38.0 / 37.0 / 36.0 / 35.0 / 34.0 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0 Sound pressure level 3 (H / M / L) dB(A) 37 / 32 / 28 37 / 34 / 28 38 / 34 / 29 45 / 38 / 33
Dimensions (HXWXD) mm 235X960X690 235X1270X690 235X1590X690 Dimensions Unit mm 256X840X840 298X840X840
Machine weight kg 25 32 38 (HXWXD) Decoration panel mm 50X950X950
Certified Cooling °CWB 14 to 25 Machine Unit kg 19 22 24
Operation range Heating °CDB 15 to 27 weight Decoration panel kg 5.5
Outdoor Colour Ivory white Certified Operation range °CWB 14 to 25
unit Coil Type Cross fin coil Outdoor Colour Ivory white
Compressor Type Hermetically sealed swing type unit Coil Type Micro channel
Motor output kW 1.3 2.4 3.3 Compressor Type Hermetically sealed swing type
Refrigerant charge (R32) kg 1.7 (Charged for 30 m) 2.6 (Charged for 30 m) 3.75 (Charged for 30 m) Motor output kW 1.20 1.30 1.60
Sound Cooling / Heating dB(A) 47 / 49 48 / 50 49 / 53 49 / 51 53 / 56 Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
pressure level 4
Night quiet mode dB(A) 43 44 45 49 Sound pressure level 3 Cooling dB(A) 48 49 50 51 52
Dimensions (HXWXD) mm 595X845X300 990X940X320 1,430X940X320 Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 45 69 93 Machine weight kg 34 37 44
Certified Cooling °CDB -5 to 46 Certified Operation range °CDB 21 to 46
Operation range Heating °CWB -15 to 15.5 Piping Liquid (Flare) mm 6.4 9.5
Piping Liquid (Flare) mm 9.5 connections Gas (Flare) mm 12.7 15.9
connections Gas (Flare) mm 15.9 Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26) Outdoor unit mm 18.0 (Hole)
Outdoor unit mm 26.0 (Hole) Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. interunit piping length m 50 (Equivalent length 70) 75 (Equivalent length 90) Max. installation level difference m 15 30
Max. installation level difference m 30 Heat insulation Both liquid and gas piping
Heat insulation Both liquid and gas piping

CEILING SUSPENDED TYPE (3 Phase) Heat Pump CEILING MOUNTED CASSETTE TYPE <Round Flow> (3 Phase) Cooling only
100 125 140 71 85 100 125 140
Model Indoor unit FHA100BVMV FHA125BVMA FHA140BVMA Indoor unit FCFC71DVM FCFC85DVM FCFC100DVM FCFC125DVM FCFC140DVM
Name Outdoor unit RZA100DY1 RZA125DY1 RZA140DY1 Model
Name Outdoor unit
Power supply Outdoor unit 3 Phase, 380-415V, 50Hz RZFC71DY1 RZFC85DY1 RZFC100DY1 RZFC125DY1 RZFC140DY1
Cooling Capacity 1,3 kW 10.0 (5.0-11.2) 12.5 (5.0-14.0) 14.0 (5.0-16.0) Power supply Outdoor unit 3 Phase, 380-415V, 50Hz
Rated (Min. - Max.) Btu/h 34,100 (17,100-38,200) 42,700 (17,100-47,800) 47,800 (17,100-54,600) Cooling Capacity 1,2 7.1 8.5 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
Heating capacity 2,3 kW 11.2 (5.1-12.5) 14.0 (5.1-16.0) 16.0 (5.1-18.0)
Rated (Min. - Max.) Btu/h 38,200 (17,400-42,700) 47,800 (17,400-54,600) 54,600 (17,400-61,400) 24,200 29,000 34,100 42,700 47,800
Btu/h (10,900-27,300) (14,300-34,100) (17,100-38,200) (19,500-47,800) (21,200-52,900 )
Power consumption Cooling 1 2.78 3.62 4.48
kW
Heating 2 2.73 4.05 4.75 Power consumption Cooling 1 kW 2.38 2.85 3.35 4.70 5.88
COP Cooling 3.59 3.45 3.13 COP kW/kW 2.98 2.66 2.38
kW/kW
Heating 4.11 3.46 3.37 CSPF kWh/kWh 4.67 4.29 4.10
CSPF Cooling kWh/kWh 5.86 5.62 5.02 Indoor unit Colour Unit White
Indoor unit Colour White Decoration panel Fresh white
Airflow rate m3/min 28.0 / 26.0 / 24.0 / 22.0 / 20.0 31.0 / 29.0 / 27.0 / 25.0 / 23.0 34.0 / 31.5 / 29.0 / 26.5 / 24.0 Airflow rate m3/min 23 / 18 / 13 34 / 27 / 20 36 / 29 / 21
(H / HM / M / ML / L) cfm 988 / 918 / 847 / 777 / 706 1,094 / 1,024 / 953 / 883 / 812 1,200 / 1,112 / 1,024 / 935 / 847 (H / M / L) cfm 812 / 635 / 459 1,200 / 953 / 706 1,271 / 1,024 / 741
Sound pressure level 4 (H / HM / M / ML / L) dB(A) 42.0 / 40.0 / 38.0 / 36.0 / 34.0 44.0 / 42.5 / 41.0 / 39.0 / 37.0 46.0 / 44.0 / 42.0 / 40.0 / 38.0 Sound pressure level 3 (H / M/ L) dB(A) 37 / 34 / 28 38 / 34 / 29 45 / 38 / 33 46 / 40 / 33
Dimensions (HXWXD) mm 235X1590X690 Dimensions Unit mm 256X840X840 298X840X840
Machine weight kg 38 (HXWXD) Decoration panel mm 50X950X950
Certified Cooling °CWB 14 to 25 Machine Unit kg 22 24
Operation range Heating °CDB 15 to 27 weight Decoration panel kg 5.5
Outdoor Colour Ivory white Certified Operation range °CWB 14 to 25
unit Coil Type Cross fin coil Outdoor Colour Ivory white
Compressor Type Hermetically sealed swing type unit Coil Type Micro channel
Motor output kW 3.3 Compressor Type Hermetically sealed swing type
Refrigerant charge (R32) kg 3.75 (Charged for 30 m) Motor output kW 1.60 2.40
Sound Cooling / Heating dB(A) 48 / 50 49 / 51 53 / 56 Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
pressure level 4
Night quiet mode dB(A) 44 45 49 Sound pressure level 3 Cooling dB(A) 50 51 52 54 56
Dimensions (HXWXD) mm 1,430X940X320 Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 93 Machine weight kg 46 62
Certified Cooling °CDB -5 to 46 Certified Operation range °CDB 21 to 46
Operation range Heating °CWB -15 to 15.5 Piping Liquid (Flare) mm 9.5
Piping Liquid (Flare) mm 9.5 connections Gas (Flare) mm 15.9
connections Gas (Flare) mm 15.9 Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26) Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
Outdoor unit mm 26.0 (Hole) Max. interunit piping length m 50 (Equivalent length 70)
Max. interunit piping length m 75 (Equivalent length 90) Max. installation level difference m 30
Max. installation level difference m 30 Heat insulation Both liquid and gas piping
Heat insulation Both liquid and gas piping Note :
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
3
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

67 68
SPECIFICATIONS RZFC series

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (1 Phase) Cooling only DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE (1 Phase) Cooling only
40 50 60 71 85 100 40 50 60 71 85
Indoor unit FBFC40DVM(9) FBFC50DVM(9) FBFC60DVM(9) FBFC71DVM(9) FBFC85DVM(9) FBFC100DVM(9) Indoor unit FDBF40DV1 FDBF50DV1 FDBF60DV1 FDBF71DV1 FDBF85DV1
Model Model
Name Outdoor unit Name Outdoor unit
RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC85DVM RZFC100DVM RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC85DVM
Power supply Indoor unit ---------- Power supply Indoor unit ----------
Outdoor unit 1 Phase, 220–240 / 220-230V, 50 / 60Hz Outdoor unit 1 Phase, 220-240V, 50Hz
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 10.0 Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2) Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0)
13,600 17,000 20,500 24,200 29,000 34,100 13,600 17,100 20,500 24,200 29,000
Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) (17,100-38,200) Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100)
Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.74 3.17 Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.98
COP kW/kW 3.35 3.20 2.90 3.00 3.10 3.15 COP kW/kW 3.35 3.20 2.90 3.00 2.85
CSPF kWh/kWh 4.38 4.18 3.98 CSPF kWh/kWh 4.38 4.13 3.93
Indoor unit Colour ---------- Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m /min
3
15.5 / 12 / 9 25 / 20 / 16.5 36 / 30.5 / 25 Fan Airflow rate (H/M/L) m /min
3
15 / 12 / 9.5 22.5 / 20 / 17.5
cfm 547 / 424 / 318 883 / 706 / 582 1,271 / 1,077 / 883 cfm 530 / 424 / 335 794 / 706 / 618
External static pressure 3 Pa Rated 30 (30-130) Rated 40 (40-140) Rated 50 (50-150) External static pressure Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 37 / 35 / 30 39 / 37 / 34 40 / 37.5 / 35 Sound pressure level 3 (H/M/L) dB(A) 37 / 33 / 25 39 / 35 / 33
Air filter 5 ---------- Air filter 4 ----------
Dimensions (HXWXD) mm 245X700X800 245X1,000X800 245X1,400X800 Dimensions (HXWXD) mm 245X700X800 245X1,000X800
Machine weight kg 26 36 46 Machine weight kg 26 36
Certified Operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Micro channel unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60 Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m) Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 4 Cooling dB(A) 48 49 50 51 52 Sound pressure level 3 Cooling dB(A) 48 49 50 51
Dimensions (HXWXD) mm 595X845X300 695X930X350 Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44 Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5 Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9 connections Gas (Flare) mm 12.7 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 18.0 (Hole) Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70) Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. installation level difference m 15 30 Max. installation level difference m 15 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE (3 Phase) Cooling only DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE (3 Phase) Cooling only
71 85 100 125 140 71 85
Indoor unit FBFC71DVM(9) FBFC85DVM(9) FBFC100DVM(9) FBFC125DVM(9) FBFC140DVM(9) Indoor unit FDBF71DV1 FDBF85DV1
Model Model
Name Name Outdoor unit
Outdoor unit RZFC71DY1 RZFC85DY1 RZFC100DY1 RZFC125DY1 RZFC140DY1 RZFC71DY1 RZFC85DY1
Power supply Indoor unit ---------- Power supply Indoor unit ----------
Outdoor unit 3 Phase, 380-415V, 50Hz Outdoor unit 3 Phase, 380-415V, 50Hz
Cooling Capacity 1,2 7.1 8.5 10.0 12.5 14.0 Cooling Capacity 1,2 7.1 8.5
kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5) Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0)
Rated (Min. - Max.)
24,200 29,000 34,100 42,700 47,800 24,200 29,000
Btu/h (10,900-27,300) (14,300-34,100) (17,100-38,200) (19,500-47,800) (21,200-52,900) Btu/h (10,900-27,300) (14,300-34,100)
Power consumption Cooling 1
kW 2.37 2.74 3.17 5.21 6.22 Power consumption Cooling 1
kW 2.37 2.98
COP kW/kW 3.00 3.10 3.15 2.40 2.25 COP kW/kW 3.00 2.85
CSPF kWh/kWh 3.98 3.71 3.60 CSPF kWh/kWh 3.93
Indoor unit Colour ---------- Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 25 / 20 / 16.5 36 / 30.5 / 25 Fan Airflow rate (H/M/L) m3/min 22.5 / 20 / 17.5
cfm 883 / 706 / 582 1,271 / 1,077 / 883 cfm 794 / 706 / 618
External static pressure 3 Pa Rated 40 (40-140) Rated 50 (50-150) External static pressure Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 39 / 37 / 34 40 / 37.5 / 35 Sound pressure level 3 (H/M/L) dB(A) 39 / 35 / 33
Air filter 5 ---------- Air filter 4 ----------
Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800 Dimensions (HXWXD) mm 245X1,000X800
Machine weight kg 36 46 Machine weight kg 36
Certified Operation range °CWB 14 to 25 Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Micro channel unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type Compressor Type Hermetically sealed swing type
Motor output kW 1.60 2.40 Motor output kW 1.60 1.60 2.40
Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m) Refrigerant charge (R32) kg 1.0 (Charged for 15 m)
Sound pressure level 4 Cooling dB(A) 50 51 52 54 56 Sound pressure level 3 Cooling dB(A) 50 51
Dimensions (HXWXD) mm 695X930X350 990X940X320 Dimensions (HXWXD) mm 695X930X350
Machine weight kg 46 62 Machine weight kg 46
Certified Operation range °CDB 21 to 46 Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Outdoor unit mm 18.0 (Hole) 26.0 (Hole) Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping

Note : Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
4
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.

69 70
SPECIFICATIONS RZFC series OPTIONS RZF series RZA series

DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE (1 Phase) Cooling only Indoor unit
Indoor unit
40
FDLF40DV1
50
FDLF50DV1
60
FDLF60DV1
71
FDLF71DV1
85
FDLF85DV1
CEILING MOUNTED CASSETTE TYPE < Round Flow >
Model Kit name
Name Outdoor unit Name of option Remark
RZFC40DVM RZFC50DVM RZFC60DVM RZFC71DVM RZFC85DVM FCF50CVM FCF60CVM FCF71CVM FCF100CVM FCF125CVM FCF140CVM
Power supply Indoor unit ---------- Standard panel with Fresh white BYCQ125EEF
Outdoor unit 1 Phase, 220-240V, 50Hz Sensing Black BYCQ125EEK
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 Decoration Fresh white BYCQ125EAF
kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) 1 panel Standard panel
Rated (Min. - Max.) Black BYCQ125EAK
13,600 17,100 20,500 24,200 29,000 Designer panel 1 Fresh white BYCQ125EAPF
Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) Auto grille panel 2,3 Fresh white BYCQ125EASF
Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.98 Sealing material of air discharge outlet 4 For usage of 3-, 4-way flow KDBH551C160
2
COP kW/kW 3.35 3.20 2.90 3.00 2.85 For usage of 2-way flow KDBH552C160
CSPF kWh/kWh 4.33 4.13 3.93 3 Panel spacer KDB55J160F
Indoor unit Colour ---------- Fresh air intake kit Chamber Without T-duct joint KDDP55B160 (Components: KDDP55C160-1, KDDP55B160-2) 8
Fan Airflow rate (H/M/L) m /min
3
16 / 14 / 12 20 / 18 / 16.5 4 type 5,6 With T-duct joint KDDP55B160K (Components: KDDP55C160-1, KDDP55B160K2) 8
cfm 565 / 494 / 424 706 / 635 / 582 Direct installation type 7 KDDP55X160A
External static pressure Pa Rated 15 (15-38) High-efficiency filter unit 9 (Colorimetric method 65%) KAF556D80 KAF556D160
5 (Including filter chamber)
Sound pressure level 3 (H/M/L) dB(A) 37 / 33 / 30 40 / 37 / 34 (Colorimetric method 90%) KAF557D80 KAF557D160
Air filter Mould-proof air filter (Removable / Washable / Mould proof) Replacement high-efficiency filter 9,10 (Colorimetric method 65%) KAF552D80 KAF552D160
6
Dimensions (HXWXD) mm 200X900X620 200X1,100X620 (Colorimetric method 90%) KAF553D80 KAF553D160
Machine weight kg 28 31 7 Filter chamber KDDFP55C160
Certified Operation range °CWB 14 to 25 8 Replacement long-life filter KAF5511D160
Outdoor Colour Ivory white 9 Replacement long-life filter (Auto grille panel) KAF5512D160
unit Coil Type Micro channel 10 Ultra long-life filter unit (Including filter chamber) 9 KAF555D160
Compressor Type Hermetically sealed swing type 11 Replacement ultra long-life filter 9,10 KAF550D160
Motor output kW 1.20 1.30 1.60 12 Branch duct chamber 4 KDJP55C80 KDJP55C160
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m) 13 Insulation kit for high humidity 9,11 KDTP55K80A KDTP55K160A
Sound pressure level 3 Cooling dB(A) 48 49 50 51 Cooling only BRC7M635F (Fresh white) / BRC7M635K (Black)
14 Remote controller Wireless type
Dimensions (HXWXD) mm 595X845X300 695X930X350 Heat pump BRC7M634F (Fresh white) / BRC7M634K (Black)
Machine weight kg 34 37 44 15 Navigation remote controller Wired type 12 BRC1E63
Certified Operation range °CDB 21 to 46 16 Central remote controller 13 DCS302CA61
Piping Liquid (Flare) mm 6.4 9.5 17 Unified ON/OFF controller 13 DCS301BA61
connections Gas (Flare) mm 12.7 15.9 18 Schedule timer 13 DST301BA61
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32) 19 intelligent Touch Controller 13 DCS601C51
Outdoor unit mm 18.0 (Hole) 20 Adaptor for wiring 14 BRP11B62
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70) 21 Wiring adaptor for electrical appendices 14 KRP4AA53
Max. installation level difference m 15 30 22 Installation box for adaptor PCB KRP1H98A
Heat insulation Both liquid and gas piping 23 Remote sensor (for indoor temperature) BRCS01A-5
24 Wireless LAN connecting adaptor BRP072C42-1
Note:
1
When installing designer panel, body height (ceiling required dimension) is 42 mm higher than 7
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow.
standard panel. Designer panel cannot operate 2 and 3 way flow. The chamber type is recommended when more fresh air is necessary.
2
A dedicated remote controller (BRC16A2) for the auto grille panel is included for lowering and 8
Please order using the names of both components instead of set name.
raising the suction grille. 9
This option cannot be installed to designer panel and auto grille panel.
3
When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than 10
Filter chamber is required.
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE (3 Phase) Cooling only
4
standard panel.
Circulation airflow is not available with this option.
11
12
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.
Wiring for wired remote controller should be obtained locally.
71 85 5
When installing a fresh air intake kit (chamber type), two air outlet corners are closed. 13
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
6
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of 14
Installation box for adaptor PCB(KRP1H98A) is necessary.
Indoor unit FDLF71DV1 FDLF85DV1 the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the
Model
operating sound and may also influence temperature sensing.
Name Outdoor unit RZFC71DY1 RZFC85DY1
Power supply Indoor unit ----------
Round flow type: List of optional parts required to achieve different flow patterns
Outdoor unit 3 Phase, 380-415V, 50Hz For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
Cooling Capacity 1,2 7.1 8.5 (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
24,200 29,000
Btu/h (10,900-27,300) (14,300-34,100) All round flow 4-way flow
Power consumption Cooling 1
kW 2.37 2.98
Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
COP kW/kW 3.00 2.85 Designer panel Auto grille panel Panel spacer1
Independently installable optional parts (Chamber type) 1 , 2 (Direct installation type) for high humidity filter unit2 filter unit2
CSPF kWh/kWh 3.93 Panel/grille related Designer panel x o o o x x x
Indoor unit Colour ---------- Auto grille panel x o o o x x x
Fan Airflow rate (H/M/L) m3/min 20 / 18 / 16.5 Panel spacer1 o o o o x o o
cfm 706 / 635 / 582 Auxillary function related Fresh air intake kit (Chamber type)1,2 o o o x x o o
External static pressure Pa Rated 15 (15-38) Fresh air intake kit (Direct installation type) o o o x o o o
Sound pressure level 3 (H/M/L) dB(A) 40 / 37 / 34 Insulation kit for high humidity x x x x o x x
Air filter Mould-proof air filter (Removable / Washable / Mould proof) Filter related High-efficiency filter unit2 x x o o o x x
Dimensions (HXWXD) mm 200X1,100X620 Ultra long-life filter unit2 x x o o o x x
Machine weight kg 31
Certified Operation range °CWB 14 to 25 3-way flow 2-way flow 5
Outdoor Colour Ivory white Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Designer panel Auto grille panel Panel spacer1,3
unit Coil Type Micro channel Independently installable optional parts (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2

Compressor Type Hermetically sealed swing type Panel/grille related Auto grille panel x o o x x x
Motor output kW 1.60 1.60 2.40 Panel spacer1,3 x x x
Refrigerant charge (R32) kg 1.0 (Charged for 15 m) Auxillary function related Fresh air intake kit (Chamber type)1,2 x o x x x o
Sound pressure level 3 Cooling dB(A) 50 51 Fresh air intake kit (Direct installation type) x o x o x o
Dimensions (HXWXD) mm 695X930X350 Insulation kit for high humidity x x x x o x x
Machine weight kg 46 Filter related Ultra long-life filter unit2 x x o o x x

Piping
Certified Operation range
Liquid (Flare)
°CDB 21 to 46
Branch duct connection
mm 9.5
connections Gas (Flare) mm 15.9 Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Designer panel Auto grille panel Panel spacer1
Independently installable optional parts (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Branch duct chamber 1 1-way branch / unit 3-way flow o o o o o 4
x x o
Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
2-way branch / unit 2-way flow x o x o o 4
x x o
1-way branch / unit 2-way flow x o x o o 4
x x o
Max. installation level difference m 30
Heat insulation Both liquid and gas piping 1. In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not
joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) When branch ducts are used, circulation airflow is not available.
2
Capacities are net, including a deduction for cooling for indoor fan motor heat. 2. When two different types of optional chambers are used together, a fresh air intake kit must be installed in the upper position.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 3. It is not possible to use panel spacers in a 2-way flow installation. (△)
4. It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
5. When 3-way or 2-way flow is selected, circulation airflow is not available.

71 72
OPTIONS RZF series RZA series

Indoor unit
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE FLOOR STANDING TYPE
Kit name Kit name
No. Name of option Remark
FFF50BV1 FFF60BV1 No. FVA50AMVM FVA100AMVM
Name of option Remark
1 Decoration panel BYFQ60B3W1 FVA60AMVM FVA125AMVM
FVA71AMVM FVA140AMVM
2 Sealing material of air discharge outlet KDBH44BA60
1 Replacement long-life filter KAF95M160
3 Panel spacer KDBQ44BA60A
Cooling only BRC4C66
4 Fresh air intake kit Direct installation type KDDQ44XA60 2 Remote controller Wireless type
Heat pump BRC4C65
5 Replacement long-life filter KAF441C60
3 Navigation Remote Controller Wired type 1 BRC1E63
6 Remote controller Wireless type Cooling only BRC7E531W
4 Central remote controller 2 DCS302CA61
7 Navigation remote controller Wired type 1 BRC1E63
5 Unified ON/OFF controller 2 DCS301BA61
8 Central remote controller 2 DCS302CA61
6 Schedule timer 2 DST301BA61
9 Unified ON/OFF controller 2 DCS301BA61
7 intelligent Touch Controller 2 DCS601C51
10 Schedule timer 2
DST301BA61
8 Adaptor for wiring 3 BRP11B61
11 intelligent Touch Controller 2 DCS601C51
9 Wiring adaptor for electrical appendices(2) 3 KRP4AA52
12 Adaptor for wiring 3 BRP11B61
10 Installation box for adaptor PCB KRP4AA95
13 Wiring adaptor for electrical appendices(2) 3 KRP4AA53
Note :
14 Installation box for adaptor PCB KRP1BB101 1
Wiring for wired remote controller should be obtained locally.
15 Remote sensor (for indoor temperature) BRCS01A-1
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA95) is necessary.
16 Interface adaptor for SkyAir series DTA112BA51
Note :
1
Wiring for wired remote controller should be obtained locally.

CEILING SUSPENDED TYPE


2
This optional accessory requires DTA112BA51.
3
Installation box for adaptor PCB (KRP1BB101) is necessaary.
Kit name

No. FHA100BVMV
Name of option Remark FHA50BVMV
FHA71BVMV FHA125BVMA
FHA60BVMV
FHA140BVMA
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE 1 Replacement long-life filter Resin net KAF501B56 KAF501B80 KAF501B160
Kit name 2 Fresh air intake kit KDDQ50A140
No. Name of option Remark FBA50BVMA(9) FBA100BVMA(9) 3 Drain pump kit KDU50R160
FBA60BVMA(9) FBA125BVMA(9)
FBA71BVMA(9) FBA140BVMA(9) 4 L-type piping kit (for upward direction) KHFP5N160

1 Long-life filter1 KAF631C80 KAF631C160 Cooling only BRC7M56


5 Remote controller Wireless type
65% KAF632C80 KAF632C160 Heat pump BRC7M53
2 High-efficiency filter1
90% KAF633C80 KAF633C160 6 Navigation Remote Controller Wired type 1 BRC1E63
3 Filter chamber (for rear suction)1 KDDFP63B80 KDDFP63B160 7 Central remote controller 2 DCS302CA61
4 Service panel Fresh white KTBJ25K80F KTBJ25K160F 8 Unified ON/OFF controller 2 DCS301BA61
5 Air discharge adaptor KDAP25A71A KDAP25A140A 9 Schedule timer 2 DST301BA61
6 Shield plate for side plate KDBD63A160 10 intelligent Touch Controller 2 DCS601C51
Cooling only BRC4C66 11 Adaptor for wiring BRP11B61
7 Remote controller Wireless type
Heat pump BRC4C65 12 Wiring adaptor for electrical appendices 3 KRP4AA52
8 Navigation Remote Controller Wired type2 BRC1E63 13 Installation box for adaptor PCB KRP1D93A
9 Remote sensor (for indoor temperature) BRCS01A-4 14 Adaptor box mounting plate KKSAP50A56 ----------
10 Adaptor for wiring BRP11B62 15 Remote sensor (for indoor temperature) BRCS01A-4
11 Wiring adaptor for electrical appendices(2) KRP4AA51 Electrical box with earth terminal (3 blocks)
16 KJB311AA
12 Mounting plate for adaptor PCB.3,4,5 KRP4A98
17 Electrical box with earth terminal (2 blocks) KJB212AA
13 Central remote controller6 DCS302CA61
18 Wireless LAN connecting adaptor BRP072C42-1
14 Unified ON/OFF controller6 DCS301BA61
Note :
15 Schedule timer6 DST301BA61 1
Wiring for wired remote controller should be obtained locally.
16 intelligent Touch Controller6 DCS601C51
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP1D93A) is necessary.
17 Wireless LAN connecting adaptor BRP072C42-1
Note :
1
If installing high efficiency filter and long-life filter to the unit, filter chamber is required.
2
Wiring for wired remote controller should be obtained locally. Kit name
3
Mounting plate is necessary for each adaptor marked .
4
Up to 2 adaptors can be fixed for each mounting plate.
5
Only one mounting plate can be installed for each indoor unit.
6
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

Outdoor unit
CEILING MOUNTED SLIM DUCT TYPE 1 Phase RZF50/60/71CV2V RZA50/60DV2V RZA71/100/125/140DV1
RZF100CVM RZF125/140CVM
Kit name No. Name of option
No. Name of option Remark 3 Phase ---------- ---------- RZF71/100CYM RZF125/140CYM RZA100/125/140DY1
FDF50BV1 FDF60BV1
Remote controller Wireless type Cooling only 1 Central drain plug KKP014A4 KKP937A4 KKPJ5G280
1 BRC4C64
2 Fixture for preventing overturning ---------- KKTP5B112
2 Navigation remote controller Wired type 1 BRC1E63
3 Wire fixture for preventing overturning ---------- K-KYZP15C
3 Remote sensor (for indoor temperature) BRCS01A-1
4 Demand adaptor ---------- KRP58M6 KRP58M51 KRP58M51+EKMKSA1 KRP58M51+EKMKSA2
4 Insulation kit for high humidity KDT25N63
1 Phase BRV2BPSF ---------- BRV2BPSS BRV2BPL ----------
Note : 5 Overvoltage PCB
1
Wiring for wired remote controller should be obtained locally. 3 Phase ---------- BRV2BPSS+BRV2BPSS ----------

73 74
OPTIONS RZFC series

Indoor unit
CEILING MOUNTED CASSETTE TYPE < Round Flow > DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Kit name Kit name
FCFC40DVM FCFC100DVM No. Name of option Remark FBFC40DVM(9) FBFC71DVM(9) FBFC100DVM(9)
No. Name of option Remark FCFC71DVM FBFC50DVM(9) FBFC125DVM(9)
FCFC50DVM FCFC125DVM FBFC85DVM(9)
FCFC85DVM FBFC60DVM(9) FBFC140DVM(9)
FCFC60DVM FCFC140DVM
1 Long-life filter 1 KAF631C56 KAF631C80 KAF631C160
1 Decoration panel Standard panel Fresh white BYCQ125EAF
65% KAF632C56 KAF632C80 KAF632C160
For usage of 3-, 4-way flow KDBH551C160 2 High-efficiency filter 1
2 Sealing material of air discharge outlet 90% KAF633C56 KAF633C80 KAF633C160
For usage of 2-way flow KDBH552C160
3 Filter chamber(for rear suction)1 KDDFP63B56 KDDFP63B80 KDDFP63B160
3 Panel spacer KDB55J160F
4 Service panel Fresh white KTBJ25K56F KTBJ25K80F KTBJ25K160F
Chamber Without T-duct joint KDDP55B160 (KDDP55C160-1, KDDP55B160-2) 4

type 1,2 5 Air discharge adaptor KDAP25A56A KDAP25A71A KDAP25A140A


4 Fresh air intake kit With T-duct joint KDDP55B160K (KDDP55C160-1, KDDP55B160K2) 4

6 Shield plate for side plate KDBD63A160


Direct installation type 3 KDDP55X160A
7 Remote controller Wireless type Cooling BRC4C66
(Colorimetric method 65%) KAF556D80 KAF556D160
5 High-efficiency filter unit 8 Simplified Remote Controller Wired type 2 BRC2E61
(Including filter chamber) (Colorimetric method 90%) KAF557D80 KAF557D160
9 Remote sensor (for indoor temperature) BRCS01A-4
(Colorimetric method 65%) KAF552D80 KAF552D160
6 Replacement high-efficiency filter 5 10 Adaptor for wiring 3 BRP11B62
(Colorimetric method 90%) KAF553D80 KAF553D160
11 Wiring adaptor for electrical appendices(2) 3 KRP4AA51
7 Filter chamber KDDFP55C160
12 Mounting plate for adaptor PCB.3,4,5 KRP4A98
8 Replacement long-life filter KAF5511D160
13 Central remote controller 6 DCS302CA61
9 Ultra long-life filter unit (Including filter chamber) KAF555D160
14 Unified ON/OFF controller 6 DCS301BA61
10 Replacement ultra long-life filter 5 KAF550D160
15 Schedule timer 6 DST301BA61
11 Branch duct chamber KDJP55C80 KDJP55C160
16 intelligent Touch Controller 6 DCS601C51
12 Insulation kit for high humidity 6 KDTP55K80A KDTP55K160A
17 Drain pump kit BDU24AMD2
13 Remote controller Wireless type Cooling only BRC7F635F
Note:
14 Simplified remote controller Wired type 7 BRC2E61 1
If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate.
2
Wiring for wired remote controller should be obtained locally. 5
Only one mounting plate can be installed for each indoor unit.
15 Central remote controller 8
DCS302CA61 3
Mounting plate is necessary for each adaptor marked . 6
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
16 Unified ON/OFF controller 8 DCS301BA61
17 Schedule timer 8 DST301BA61
18 intelligent Touch Controller 8 DCS601C51
19 Adaptor for wiring 9 BRP11B62
20 Wiring adaptor for electrical appendices 9 KRP4AA53 DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
Kit name
21 Installation box for adaptor PCB KRP1H98A
No. Name of option Remark FDBF40DV1 FDBF71DV1
22 Remote sensor (for indoor temperature) BRCS01A-5 FDBF50DV1 FDBF85DV1
Note: FDBF60DV1
1
When installing a fresh air intake kit (chamber type), two air outlet corners are closed. 4
Please order using the names of both components instead of set name. 1 Remote controller Wireless type Cooling BRC4C66
2
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of 5
Filter chamber is required.
the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the 6
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH. 2 Simplified Remote Controller Wired type 1 BRC2E61
operating sound and may also influence temperature sensing. 7
Wiring for wired remote controller should be obtained locally.
3
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. 8
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 3 Remote sensor (for indoor temperature) BRCS01A-1
The chamber type is recommended when more fresh air is necessary. 9
Installation box for adaptor PCB(KRP1H98A) is necessary.
Note:
1
Wiring for wired remote controller should be obtained locally.

Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. Kit name
No. Name of option Remark FDLF40DV1 FDLF71DV1
FDLF50DV1 FDLF85DV1
Optional accessory parts
Panel spacer1 Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life FDLF60DV1
Independently installable optional parts (Chamber type) 1 , 2 (Direct installation type) for high humidity filter unit2 filter unit2
Panel/grille related Panel spacer1 o o x o o 1 Remote controller Wireless type Cooling BRC4C66

All-round flow Auxillary function related Fresh air intake kit (Chamber type)1,2 o x x o o 2 Simplified Remote Controller Wired type 1 BRC2E61
4-way flow Fresh air intake kit (Direct installation type) o x o o o 3 Remote sensor (for indoor temperature) BRCS01A-1
Insulation kit for high humidity x x o x x
Filter related High-efficiency filter unit2 o o o x x Note:
Wiring for wired remote controller should be obtained locally.
o o o
1
Ultra long-life filter unit2 x x

Optional accessory parts


Panel spacer1 Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life
Independently installable optional parts (Chamber type) 1 , 2 (Direct installation type) for high humidity filter unit2 filter unit2
Panel/grille related Panel spacer 1,3
x x
3-way flow
2-way flow 5
Auxillary function related Fresh air intake kit (Chamber type)1,2 x x x o
Fresh air intake kit (Direct installation type) x o x o
x x o x x
Outdoor unit
Insulation kit for high humidity
Filter related Ultra long-life filter unit2 o o x x
Kit name
Optional accessory parts Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra long-life 1 Phase RZFC40/50/60/71DVM RZFC85/100DVM ----------
Independently installable optional parts Panel spacer1 (Chamber type) 1 , 2 (Direct installation type) for high humidity filter unit2 filter unit2 No. Name of option
Branch duct Branch duct chamber 1 1-way branch / unit 3-way flow o o o 4
x x o 3 Phase ---------- RZFC71/85/100DY1 RZFC125/140DY1
connection 2-way branch / unit 2-way flow x o o 4
x x o 1 Central drain plug KKP014A4 KKP937A4 KKPJ5G280
1-way branch / unit 2-way flow x o o 4
x x o 2 Fixture for preventing overturning ---------- ---------- KKTP5B112
1. In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not 3 Wire fixture for preventing overturning ---------- ---------- K-KYZP15C
joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. When branch ducts are used, circulation airflow is not available.
2. When two different types of optional chambers are used together, a fresh air intake kit must be installed in the upper position.
3. It is not possible to use panel spacers in a 2-way flow installation. (△)
4. It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
5. When 3-way or 2-way flow is selected, circulation airflow is not available.

75 76