SURAT DUKUNGAN

Penangkal Petir
LIGHTNING PROTECTION INTERNATIONAL PTY LTD

GUARDIAN Lightning Protection System 5


TESTED IN
ACCORDANCE
WITH IEC
62561-2

Comprehensive Lightning, Surge Protection & Earthing Solutions www.lpi.com.au


LIGHTNING PROTECTION INTERNATIONAL PTY LTD

The LPI story LPI’s 4-Step Approach Active in Industry


Lightning Protection International Pty to Lightning
Ltd (LPI) is a fully Australian owned Protection
manufacturer and supplier of direct
strike lightning protection, surge and It is the strategic aim of our company to
transient protection, and earthing / be able to provide a complete packaged
grounding solutions. solution. LPI has identified 4 key steps
when considering the complete approach
LPI has provided specialist lightning to lightning protection. Ask for our 4-Step
protection advice to customers for many approach to lightning protection.
years in some of the most lightning-prone
areas of the world. LPI personnel have
extensive experience in risk management,
system design, training, installation, OUR SYSTEM DESIGN
certification, and commissioning of APPROACH INCLUDES
lightning protection systems in a wide Definition and provision of area
variety of industry groups. 1
protection
LPI maintains a third party Quality 2 Creation of a bonded earthing
Management System to AS/NZS system
ISO 9001:2015. 3 Protection of mains power lines
LPI’s range of products and services
4 Protection of signal, data and
are exported from its head office, communication lines
research and manufacturing facility
in Tasmania, Australia as well as via
regional offices worldwide.
The company has been recognised
within Australia for its outstanding
export successes and has been awarded
several prestigious export awards.

2 L I G H T N I N G P R O T E C T I O N I N T E R N AT I O N A L P T Y LT D w w w. l p i . c o m . a u
GUARDIAN LIGHTNING PROTECTION SYSTEM 5

LPI’s Guardian™ CAT System 5 on the local codes and applications, other
materials such as flat copper or aluminium
LPI’s award-winning families of enhanced tape, smooth weave conductor or stranded
air terminals have the following key conductor may be used.
characteristics:
4. LPI Lightning Strike Recorder (LSR2)
• First company to introduce corona- which confirms system efficiency and
minimising terminals with optimised blunt effectiveness.
design and four independent panels;
5. An earthing system consisting of earth
• Extensive field experience with more than
rods, clamps, copper tapes and earth
50,000 installations over 15+ years in
enhancing compounds such as LPI RESLO,
more than 75 countries around the world;
SRIM PLUS or GRIP.
• Air terminal families designed to meet
direct-strike placement methodologies 1. A Family of LPI CAT (Controlled Guardian CAT Range
in compliance with various international Advanced Triggering) series air terminals.
standards; and 2. A Fibreglass Reinforced Plastic (FRP) LPI offers Guardian CAT Terminal in high-
• Proven technology based on international mast which provides an insulated mast for quality Stainless Steel.
research findings, modelling and field mounting of LPI CAT series air terminals. CAT X SS – ZZ
testing.
3. A purpose designed LPI High Voltage X: CAT terminal model. Model I, II and III
LPI’s GuardianTM System 5 provides a Shielded Cable (HVSC Plus) specifically
purpose-designed package for direct- designed for the conveying of lightning ZZ: Blank for standard version,
strike lightning protection. energy to ground. Alternatively, depending GI for 2 inch BSP GI Pipe adaptor

How does the LPI Guardian™ CAT Terminal operate?


A Guardian CAT terminal consists of a This restricts the production of “corona” rises to the point where a triggering arc
blunt, earthed lightning rod surrounded by or “point discharge” ions and is critical is generated between the panel and the
electrically floating metal panels. Rounded because excessive production of ions lightning rod. (See step 2). By design and
or blunt tips have been demonstrated (corona) results in a “space charge cloud” appropriate terminal placement, this arc
to be more efficient than sharp points above the air terminal which tends to mask occurs at the right time to ensure the
because of a reduced space charge effect. the electrical field and inhibit the formation resulting streamer will form a stable,
This principle has been proven in tests and progression of an upward leaders. progressing upward leader. (See step 3).
conducted at South Baldy Peak in central (See step 1).
The triggering arc has two key effects,
New Mexico, USA. The panels are isolated from each other namely:
(Source: “The Measurement of Lightning as well as from the lightning rod to
(i) It produces a large number of ions to
Rod Responses to Nearby Strikes” by C.B. allow the panels to rise in voltage due to
aid the initiation of an upward leader.
Moore, G.D. Aulich and W. Rison / 2001.) capacitive coupling with the approaching
downward leader, regardless of its (ii) It causes a large increase in the electric
During the static thunderstorm phase, direction of approach. The electric field field at a critical distance from the air
when the electric fields are steady at 5-15 increases as the lightning downward leader terminal, aiding propagation through this
kV/m, the panels present as a relatively approaches closer, causing increased critical area. This ensures a more efficient
low field intensification surface aided voltage difference between the panels and mode of protection with an enhanced area
by the blunt configuration of the rod tip. the lightning rod. Eventually, the voltage of protection.

STEP 1 STEP 2 STEP 3

Capacitive coupling
Blunt, earthed Formation of ionised
lightning rod path for the lightning
Triggered arc across discharge
air gap initiates streamer
Air gap

Four electrically Electrically isolated panels Four electrically


floating panels rise in voltage as the isolated panels
electric field increases
Downconductor Downconductor
Downconductor

Lightning earth Lightning earth Lightning earth

3 L I G H T N I N G P R O T E C T I O N I N T E R N AT I O N A L P T Y LT D w w w. l p i . c o m . a u
GUARDIAN LIGHTNING PROTECTION SYSTEM 5

Lightning Strike Recorder (LSR2)


Downconductors LPI has developed a LSR which is
LPI offers a comprehensive range of downconductors for designed for easy mounting on a
the safe and efficient passage of lightning energy to a downconductor to effectively count the
dedicated lightning earth. number of lightning strikes captured
by the Guardian CAT Terminal. LSR
Tester available on request, contact
LPI for details.

Lightning Protection Earths


The installation of a radial and rod arrangement is recommended
for each lightning protection earth. This earthing configuration
provides an effective means for the safe dissipation of the lightning
energy into the ground mass. All individual lightning earths should
be bonded together in a ring earth arrangement to minimise
ground loops and potential differences under transient conditions.
Compliance to all international standards requires an earth
resistance reading of less than 10 Ohms for the lightning earths.

25 mm x 3 mm
Earth Rods clamped to Copper Tape
Copper Tape
Tape Clamp

HVSC Plus has been tested by


a certified, independent high
Earth Pit
voltage laboratory located at
Monash University, Australia. Earth Rod
Clamp
Withstand Voltage ≥ 500 kV Each Radial Trench
is treated with
Earth Enhancing
LPI offers a selection of LPI Copper Tape
Compound
25 x 3 mm typically 3 Radial
downconductors and fixing Lengths of 10 m, 500 mm depth
accessories: with a maximum depth of 1000 mm

Refer to Guardian Installation graphic, page 5.

High Voltage Shielded


Cable (HVSC Plus) Key components of a lightning earth include:

Flat tapes –
∆ Earth Rods –
Copperbonded (threaded or
Bare, Tinned & unthreaded), Solid Copper
PVC Covered, Copper or Stainless Steel
and Aluminium
∆ Earth Enhancing
Compounds
Stranded Conductors - to assist in
Bare, Tinned and lowering soil
PVC Coated (Copper) resistance
Smooth Weave Conductors -
Bare Al, Cu and Tinned Copper ∆ Mechanical
Earth Pits
Clamps and

Downconductor Fixings Polymer earth pit


Concrete earth pit
and Connectors
∆ Earth Electrodes – Use of flat copper tape is
recommended as it provides greater
surface contact with the soil
mass as opposed to circular
or stranded copper
conductors

4 L I G H T N I N G P R O T E C T I O N I N T E R N AT I O N A L P T Y LT D w w w. l p i . c o m . a u
GUARDIAN LIGHTNING PROTECTION SYSTEM 5

Application
LPI GUARDIAN CAT TERMINAL
LPI’s Guardian CAT series terminals come in three sizes, ORDERING CODE: CAT I-SS
CAT II-SS
providing users with a tailored, customised design (provided by IMPORTANT: CAT III-SS
Guardian CAT terminal to be
LPI) for the application at hand. a minimum of 2 metres above
LPI UPPER TERMINATION KIT
ORDERING CODE: UTERMKIT-Mk3
the highest point of the
building. LPI SUPPORT MAST
LPI uses a software program called “CATCALC”. It takes into Recommended clearance ORDERING CODE: FRP-2M
height = 5 metres FRP-3M
consideration all of the key lightning parameters and site FRP-4M
factors relevant to the project, e.g., lightning activity, structure LPI INLINE COUPLING
height and dimensions, and level of protection (a choice of ORDERING CODE: ILCOUPLING
LPI GUY KIT
“Standard”, “High” and “Very High”). ORDERING CODE: GUYKIT-4M
GUYKIT-4M-SS
A key part of the calculations involves the identification and GUYKIT-7M
GUYKIT-7M-SS
allowance for “competing features” on the structure and LPI CABLE TIES
ORDERING CODE: SS-CABTIE-STD
elsewhere, which also have the ability to launch upward SS-CABTIES-L

leaders. Allowance for this phenomenon is critical, especially LPI HIGH VOLTAGE SHIELDED CABLE
ORDERING CODE: HVSCPLUS-PM
on tall structures and on sites that comprise more than one
LPI LOWER MAST ASSEMBLY WITH BASE
major structure. ORDERING CODE: ALUMB-3M
ALUMB-4M
ALUMB-5M
CATCALC designs are certified by LPI and therefore offer ALUMB-6M
additional security with regard to the provision of satisfactory
lightning protection levels, particularly in relation to the level of
lightning activity around the installation. LPI SADDLES AND FIXINGS
ORDERING CODE: SAD FIX
The protection radius computed for the Guardian CAT air BUILDING
terminals is dependent on a number of variables. The main
variables are:
• Structure height, via the original “Collection Volume”
model of Eriksson in 1987, where the striking distance has
a dependence not only on peak stroke current but also LPI HIGH VOLTAGE SHIELDED CABLE
structure height. ORDERING CODE: HVSCPLUS-PM

• The degree of electric field enhancement which depends on LPI LIGHTNING STRIKE RECORDER
ORDERING CODE: LSR2
the structure geometry, position of the CAT terminal on the
structure, the model of CAT terminal and any enhancement
multiplier effects due to sub-structures superimposed on LPI EARTH PIT
ORDERING CODE: EPIT-P, EPIT-C1D
the base structure.
LPI LOWER TERMINATION KIT
ORDERING CODE: LTERMKIT-Mk3
• The electric field distribution in the space between the
downward leader tip and the top of the structure or CAT LPI EARTHING SYSTEM
terminal. This calculation is based on a model of the LPI EARTH ENHANCING
TYPICAL PRODUCTS REQUIRED
FOR RADIAL & ROD LP EARTH:
COMPOUND
downward leader charge. ORDERING CODE:
4 X CBER3014
4 X RTC253
RESLO-20, SRIMPLUS-20, 1 X EPIT-P
• The velocity boundary that limits the striking distance GRIP-10 1 X RESLO-20
30 X FL6T253C
surface of the collection volume. This parameter is typically
defined via the velocity ratio of the downward and upward
leaders.
Structure height Protection Protection Protection
• Various other parameters, such as the cloud base height and
+ installed CAT Level - Level - Level -
the site altitude above sea level. 5 m above structure Very High High Standard

The table at right provides indicative attractive radii achieved CAT I CAT II CAT III CAT I CAT II CAT III CAT I CAT II CAT III
with the CAT terminals when placed according to the CVM / 10 35 40 50 50 60 70 70 80 90
IEEE Std. 998. 20 45 55 65 60 75 90 75 100 110
NOTE: Blank entries provide guidance on the structure height 30 50 60 75 70 85 100 80 110 120
at which the next model (larger size) of CAT terminal should be 50 70 85 95 110 120 130
used in order to provide optimum performance with regard to 80 75 90 100 120 120 130
space charge / corona effects, as described earlier. 100 75 90 115 120 128 130
The figures
in this table are 120 75 90 115 120 128 130
indicative only, a full
design should be completed 150 75 90 115 120 128 130
by LPI upon application.
All figures represented
as metres (m).

5 L I G H T N I N G P R O T E C T I O N I N T E R N AT I O N A L P T Y LT D w w w. l p i . c o m . a u
GUARDIAN LIGHTNING PROTECTION SYSTEM 5

Advantages of Research and Development


Guardian Terminals The company has an ongoing commitment throughout such countries as Australia,
1. For most applications, a Guardian to Research and Development. Indonesia, Sri Lanka, USA and South Korea.
System consists of a single CAT LPI personnel and their associates have LPI has extensive experience with HV and
lightning terminal which provides been involved in a number of field trials surge current laboratory testing, both
an enhanced area of protection, throughout lightning prone regions of in-house and at external, accredited
a single, purpose-designed, the world. This experience has extended laboratories around the world.
insulated lightning downconductor
cable for sensitive structures, or
a conventional downconductors
for standard structures, and a low
impedance earthing system.

2. LPI’s CATCALC software can determine


the optimum number, height and
location of CAT terminals required
for your project.

3. The Guardian system can be installed to TESTED IN


comply with most lightning protection ACCORDANCE
standards. The predominant placement WITH IEC Disclaimer
method used in the CATCALC software 62561-2 ∆ LPI maintains a policy of on-going product development,
is the CVM, per IEEE Std. 998. specifications are subject to change without notice.
4. LPI’s Guardian system is simple to install ∆ Application detail, illustrations and schematic drawings are
and requires no special maintenance. representative only and should only be used as guides.
∆ It should be noted that 100% protection level for direct strike
5. LPI’s Guardian is a very economical lightning, lightning detection and surge and transient protection
lightning protection solution whilst equipment cannot be provided due to the lightning discharge
providing superior security. process being a random atmospheric event.

6. The design of LPI’s CAT terminals is


based on the most recent research,
development and improvements
within the industry.

Distributed by: LIGHTNING PROTECTION


INTERNATIONAL PTY LTD
ABN 11 099 190 897

PO Box 379 Kingston, Tasmania, Australia 7051


49 Patriarch Drive, Huntingfield, Tasmania, Australia 7055

∆ Telephone: +61 3 6281 2475


∆ Email: info@lpi.com.au
∆ Web: www.lpi.com.au

© Copyright 2020 Lightning Protection International Pty Ltd. BR-GUARD-CAT-V8


Complies with NF C 17-102 Standard
Who is LPI? LPI Product Offering
Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd offers a comprehensive
(LPI) is a fully owned Australian manufacturer range of products and services as part of its complete solution
and supplier of direct strike lightning, surge & to your lightning problems. These products cover Direct strike
transient protection equipment and grounding protection, surge and transient protection and grounding
products to a wide range of industries solutions.
throughout the world. • Stormaster range of ESE Air terminals, compliant to NF C 17-102
LPI personnel and their associates have • Guardian Lightning Protection System 5
combined experience over many years in servicing • Conventional lightning protection
customers throughout the world on many types of • Surge and Transient protection products for power lines
projects in some of its most lightning prone areas.
• Surge and Transient protection products for data,
Our personnel have vast experience in providing communications and signal lines
direct strike area protection, surge and transient
• “EXOWELD” range of exothermic welding products for the
protection and grounding solutions. Our extensive connection of grounding conductors
experience has involved risk management, system
• Ground rods and accessories
design, training, certification and installation and
commissioning in key industry groups such as: • Earth Enhancing Compounds for the lowering of soil resistivity

• Telecommunications & Broadcasting • FRP Mast


• Aluminium
• Petrochemical, oil & gas Mast
• GI Pipe

• Highrise buildings and hotels – all types of


structures STORMASTER
DOWNCONDUCTOR
ESE Air Terminal
• Sporting centre and grounds – Golf courses,
race tracks, stadiums
• Aviation - Civil & Military High Voltage
Shielded Cable
• Mining – coal, gold, nickel, iron, copper,
bauxite etc.
• Industrial facilities of all kinds
• Defence – communications, surveillance Copper Tape

and storage of armaments


• Power generation and distribution
• Rail / transport systems
• Monuments / Ecological sites Ground Resistance Lightning
Improvement Powder Strike
(GRIP) Recorder
(LSR)
LPI’s Stormaster ESE
The LPI Stormaster ESE range of terminals provides a safe The energy is conveyed to ground via downconductor(s).
and efficient system for the protection of your facility from When the energy enters the dedicated lightning earth, it is
direct lightning strikes. The LPI Stormaster ESE terminal safely dissipated without risk to personnel and equipment.
captures the lightning energy at a preferred point.

How does the LPI Stormaster ESE Terminal work?


The Stormaster Early Streamer Emission air terminal which initiates the triggering of an upward streamer from
uses the naturally occurring electrical field to complete the Stormaster ESE terminal. The concept of earlier allows
the timely release of an upward streamer. This process for a larger or enhanced area of protection to be provided
provides for a safe and efficient method of controlling by the Stormaster ESE in comparison to a conventional rod.
dangerous lightning energy at a preferred point.
With the release of the upward streamer from the finial
As a thunder storm gathers overhead the ambient electrical tip earlier than other competing structural points,
field surrounding the Stormaster ESE begins to rise in the Stormaster ESE terminal becomes a preferred
voltage. Upon the approach of a downleader towards the point for the capture of the lightning discharge
protected area there is a rapid increase in the electric field within the protected area.

The Stormaster ESE Range


LPI offers two models in STORMASTER-ESE-60
STORMASTER-ESE-50
it’s range of Early Streamer
Emission air terminals.

Both terminals have been


tested to NF C 17-102.

 Stormaster-ESE-50
 Stormaster-ESE-50-GI
 Stormaster-ESE-60
 Stormaster-ESE-60-GI

GI Model - For direct mounting to 2” dia. GI Pipe.

Lightning Strike Recorder (LSR)


LPI have developed a Lightning Strike Recorder (LSR) which is designed for
easy mounting on a downconductor to effectively count the number of lightning
strikes captured by the Stormaster ESE Terminal.

The LSR has a current sensitivity range of 1500A through to a maximum of


220KA @ 8/20 µs impulse and operates by sensing current by means of an
inductive pickup loop. The strike recorder has a mechanical 6 digit display
secured within a polycarbonate IP 67 rated enclosure. The LSR is self powered
and does not require the use of a battery or any external power source.
Certified Performance
As one of the leading companies in the field of lightning protection, LPI
has invested heavily in field and laboratory testing as part of its on-
going commitment to research and development.

Throughout the product development of the Stormaster ESE the


proto-type models were subjected to intense testing under high
voltage conditions. Following further refinements the Stormaster
terminals were subjected to final testing by an independently
accredited test laboratory which completed testing in full
compliance with the French National Standard NF C 17-102.
The final testing of Stormaster ESE terminals showed effective
performance as defined in the French National Standard.

The objective of the testing under NF C 17-102 is to


obtain a statistical result between a single reference
rod and the ESE terminal whereby a time
difference is obtained between the two and by
definition, a triggering time advance ΔT is
calculated. Safety margins are applied to
the measured values in order to provide
a conservative measured result.

Advantages of • LPI’s Stormaster ESE system is simple to install


and requires no special maintenance.
the Stormaster
• LPI’s Stormaster ESE system is a cost effective
ESE Terminal solution for providing your lightning protection
A typical Stormaster ESE installation whilst providing superior safety.
consists of a single Stormaster
ESE terminal with an enhanced
• The Stormaster ESE range of terminals have
been fully tested in accordance with NF C 17-102
area of protection and one or more
in a high voltage laboratory.
downconductors connected to a
dedicated low impedance lightning earth.

Ground Resistance
Improvement Powder (GRIP)
Ground Resistance Improvement Powder is a ground enhancing
material which is applied in and around an earthing system to reduce
the soil resistivity and lower ground impedance. GRIP is supplied in
10kg and 40kg kits and is particularly useful in difficult sites such as
sandy soils and rocky ground. LPI recommends the installation of a radial
lightning earth to aid in the efficient dissipation of the lightning energy.

Contact LPI or an authorised representative for design assistance and for


further details on LPI’s complete range of earth enhancing compounds.
Protection Performance
Rp3
The protection radius (Rp) of a Stormaster ESE terminal is h1 Rp2
calculated using the following formula as defined by the French Rp1
National Standard NF C 17-102 (July 1995). h2

Rp = √h(2D-h) + ΔT(2D + ΔT) for ≥5m where: h3

The following key parameters determine the calculation of RP.


• ΔT as established during the test.
Stormaster-ESE-50 = ΔT (µs) 50
Stormaster-ESE-60 = ΔT (µs) 60
• h = actual height of Stormaster terminal above the area to be
protected (m).
• D (in m) depends on the selected level of protection,
protection levels are specified in annex B of the standard
NF C 17-102.
D = 20m for protection level 1 (High Protection)
D = 45m for protection level 2 (Medium protection)
D = 60m for protection level 3 (Standard protection)

PROTECTION RADIUS (M) - (Rp)


h = height of Stormaster terminal 2 4 5 6 10 15 20 45 60
above area to be protected (m)
Protection Level 1 (High Protection)
Stormaster 50 28 55 68 69 69 70 70 - -
Stormaster 60 32 64 79 79 79 80 80 - -
Protection Level 2 (Medium Protection)
Stormaster 50 35 69 86 87 88 90 92 95 -
Stormaster 60 40 78 97 97 99 101 102 105
Protection Level 3 (Standard Protection)
Stormaster 50 38 76 95 96 98 100 102 110 110
Stormaster 60 44 87 107 107 109 111 113 120 120

Research and Development


The company has an ongoing commitment to Research and
Development.

LPI personnel and its associates have been involved in a number of field
trials throughout lightning prone regions of the world. This experience
has extended throughout such countries as Australia, Indonesia, Sri Lanka
the USA and South Korea.
LPI Endorsement LPI’s 4-Step Approach to
Lightning Protection International Pty Ltd forms Lightning Protection
“Partnerships” with our customers to provide complete
It is the strategic aim of our company to be able to provide a
lightning, surge and grounding solutions. Our core
complete packaged solution. LPI has identified 4 key steps when
competence is the ability to consistently deliver superior
considering the complete approach to lightning protection, ask for
performance, quality and value to customers in a broad
our “LPI 4 Step approach to lightning protection”.
range of market segments.

LPI’s Endorsement confirms our assurance of a long-


term partnership with our customers and endorses the
Our system
design approach
product quality and performance.
includes:
All products offered by LPI come
with the quality endorsement
and compliance with 1 Definition and provision of area protection
International standards 2 Creation of a bonded earthing system
and bodies wherever
3 Protection of power lines
possible.
4 Protection of signal, data and communication lines

Disclaimer LIGHTNING PROTECTION INTERNATIONAL PTY. LTD.


ABN 11 099 190 897
• LPI maintains a policy of on-going product development,
specifications are subject to change without notice. Complex 1,
16 Mertonvale Circuit, Kingston
• Application detail, illustrations and schematic drawings are Tasmania, Australia 7050.
representative only and should be used as guides.
Telephone: + 61 3 6227 1955
• It should noted that 100% (100 percent) protection level Facsimile: + 61 3 6229 1900
for direct strike lightning and surge and transient protection Email: info@lpi.com.au
equipment is not possible and cannot be provided due to the
lightning discharge process being a natural atmospheric event. Web: www.lpi.com.au

©Copyright 2003 Lightning Protection International Pty Ltd. BR-STORM-V1