Catalog 3105/USA Directional Control Valves

Technical Information Series DSH081 and DSH091

General Description DSH081C, DSH091C


Out (1)
The DSH081 and DSH091, 2-way, poppet-type,
solenoid valves are used in applications requiring on/
off valves and low leakage. Single acting cylinder In (2)
applications typically utilize valves of this type. Valves DSH081N, DSH091N
can be used for bleed down flow and/or raising and Out (1)

lowering a vertical cylinder. Normally open and nor-


mally closed configurations plus manual overrides are
available. In (2)

Operation
Normally Closed In
(2)
The valve pilot is held on its seat by spring force,
blocking pilot flow. This allows pressure at the inlet to Out
(1)
hold the poppet on its seat, thus, preventing flow
through the valve (inlet to outlet). When the coil is
energized, the valve pilot is pulled off its seat. This
vents pressure inside the poppet to the outlet port,
creating a pressure imbalance across the main poppet
which allows flow from the inlet to the outlet.
Normally Open Specifications
The valve pilot is held off of its seat by spring force. Rated Flow N.C. 30 LPM (8 GPM)
Pilot flow is vented to the outlet port, creating a N.C. Fast Res. 11 LPM (3 GPM)
pressure imbalance that moves the main poppet off it’s N.O. 30 LPM (8 GPM)
seat, allowing flow from the inlet to the outlet. When
Maximum Inlet 345 Bar (5000 PSI) - Steel
the coil is energized, the valve pilot and main poppets Pressure 210 Bar (3000 PSI) - Aluminum
are forced to close, thus blocking flow from the inlet to
the outlet. Leakage 10 drops/min. (2/3 cc/min.)
at 345 Bar (5000 PSI)

Features Minimum 90% of rated voltage


Operating Voltage at 345 Bar (5000 PSI)
• Low hysteresis
Operating Temp. -40°C to +93.3°C (Nitrile)
• Replaceable, one piece encapsulated, coils with minimal Range (Ambient) (-40°F to +200°F)
amperage draw -31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
• Variety of coil terminations and voltages
Cartridge Material All parts steel. All operating
• Variety of manual override options available
parts hardened steel.

Body Material Steel or Aluminum

Filtration ISO Code 16/13,


SAE Class 4 or better

Mounting No restrictions

Cavity DSH081 Common Cavity No. C08-2

DSH091 Common Cavity No. C09-2

dsh081.pm6.5, bl, ll

Parker Hannifin Corporation


Hydraulic Valve Division
Hydraulics DC36 Elyria, Ohio 44035 USA
Catalog 3105/USA Directional Control Valves
Technical Information Series DSH081 and DSH091

Performance Curves
Pressure Drop vs. Flow (Through cartridge only)

Normally Closed Normally Open


PSI Bar Hydraulic Oil 135 SSU @ 100°F (28 cSt) PSI Bar Hydraulic Oil 135 SSU @ 100°F (28 cSt)
240 16 240 16

200 13 200 13

-In
ut
DSH081CH & CHR
Pressure Drop (∆P)

Pressure Drop (∆P)


-O

ut
DSH091CH & CHR

O
In
160 11 160 11

120 8 120 8
Out-In
t De-Energized
In-Ou
80 6 80 6
In In-Out
Out-
Energized
40 3 40 3
DSH081C & CR
DSH091C & CR
0 0
LPM 8 15 23 30 38 LPM 8 15 23 30 38 46 53
0 0
GPM 2 4 6 8 10 GPM 2 4 6 8 10 12 14
Flow (Q) Flow (Q)

Solenoid Coil Specifications

Voltage 10 VDC 12 VDC 24 VDC 120 VAC 240 VAC

Watts 14 14 14 14 14

Amps 1.45 1.17 0.57 .144 .079

Response Time DSH081C & CR DSH081CH & CHR DSH081N & NR Wire “H” for all
(at nominal flow, DSH091C & CR DSH091CH & CHR DSH091N & NR Class voltages
5000 PSI) (Normally Closed) (N.C. Fast Res.) (Normally Open)
A.C. Integral full
Open 50ms 30ms 50ms Rectifiers wave bridge

Close 80ms 60ms 150ms

dsh081.pm6.5, bl, ll

Parker Hannifin Corporation


Hydraulic Valve Division
Hydraulics DC37 Elyria, Ohio 44035 USA
Catalog 3105/USA Directional Control Valves
Dimensions Series DSH081 and DSH091

*Inch equivalents for millimeter dimensions are shown in (**)

41.7 (1.64) 46.1 (1.82) 41.7 (1.64) 46.1 (1.82)


Normal Coil Coil Normal
31.9
Operation Overridden Overridden Operation 22.9 (1.26)
(.90)

Push & Twist Push & Twist Flush Extended


Manual Override Manual Override Manual Override Manual Override
(N.C. Valves Only) (N.O. Valves Only) (N.O. Valves Only) (N.O. Valves Only)

Cartridge Only
42.4 33.3 (1.31) 3.4 N.m.
(1.67) 3.4 N.m. (30 In.-Lbs.)
(30 In.-Lbs.) Torque
Torque

2.8 12.6
(.11) (.49)

11.5 9.9
(.45) 91.7
84.5 (3.61) (.39)
(3.33)

See Coil
Information 7/8 Hex.
For Terminal 31 N.m.
27.8 Connectors 27.8 (275 In.-Lbs.)
(1.1) In (1.1) In Torque
(2) * 3/4
16UNF-2A
(2)
Thread
K (Dia.)
Out (1) * For applications over 210 Bar
(3000 PSI), Thread Lock Out (1)
Normally Closed Compound is recommended. Normally Open
Model K (Dia.)
DSH081C & CR 12.6
DSH081CH & CHR (.50)
DSH081N & NR
DSH091C & CR 15.8 Cartridge In Body
DSH091CH & CHR (.62)
DSH091N & NR

2 13.9
(.55)
31.8
(1.25) 44.5
(1.75)

38.1 12.7
(1.50) (.50)
44.5 25.4
(1.75) (1.00)
THIRD-ANGLE
PROJECTION

dsh081.pm6.5, bl, ll

Parker Hannifin Corporation


Hydraulic Valve Division
Hydraulics DC38 Elyria, Ohio 44035 USA
Catalog 3105/USA Directional Control Valves
Ordering Information Series DSH081 and DSH091

DSH 1
Solenoid Size Poppet Style Override Seals Coil Coil Coil Body
Valve Type Option Voltage Wattage Termination Option

Code Type
Code Style Code Type
Omit Nitrile
08 3/4″ - 16UNF-2B Threaded V Fluorocarbon Omit Cartridge
Cavity with .500″ Dia. Seat without Coil
09 3/4″ - 16UNF-2B Threaded L 14 Watt
Cavity with .625″ Dia. Seat
Code Type

Omit Without Manual Override Code Description


Code Description
E Push Type Manual Override Omit Cartridge without Coil
C Normally Closed, Out (1) with Extended Rod
Metered (Normally Open Only) C 1/2″ NPTF Conduit
reverse flow. Connector with
In (2) M Push Type Manual Override 24″ 18 AWG Wires
with Flush Rod
CH Normally Closed, Out (1) (Normally Open Only) D DIN 43650
Metered (Hirschmann)
reverse flow. T Push & Twist Plug Face
Fast response In (2) Manual Override
P SAE 1B-0.25 SAE
CHR Normally Closed, Out (1)
Double Spade
Full reverse flow. (DC Only)
Fast response
In (2) W Double Wire, 24″
18 AWG (DC Only)
CR Normally Closed, Out (1)
Full reverse flow. Code Description WP Waterproof
Double Wire, 24″
In (2) Omit Cartridge without Coil 16 AWG (DC Only)

N Normally Open, Out (1) D010 10 VDC


Metered D012 12 VDC
reverse flow. Code Port Size & Material
In (2) D024 24 VDC
Omit Cartridge Only
NR Normally Open, Out (1) A120 120/110 VAC, 60/50 Hz
Full reverse flow. 4P 1/4″ NPTF (B**-2-4P) Steel
A240 240/220 VAC, 60/50 Hz
In (2) A4P 1/4″ NPTF (B**-2-A4P) Aluminum
6P 3/8″ NPTF (B**-2-6P) Steel
Shipping Weight A6P 3/8″ NPTF (B**-2-A6P) Aluminum
Cartridge Only .23 kg (.50 lbs.)
4T SAE-4 (B**-2-4T) Steel
Cartridge in Body .34 kg (.75 lbs.)
A4T SAE-4 (B**-2-A4T) Aluminum
SERVICE PARTS 6T SAE-6 (B**-2-6T) Steel
A6T SAE-6 (B**-2-A6T) Aluminum
Coil Size Coil Wattage Coil Termination Coil Voltage
4B 1/4″ BSPG (B**-2-4B) Steel
Code Size Code Type
DIN Connector: S8 1/2″ I.D. L 14 Watts A4B 1/4″ BSPG (B**-2-A4B) Aluminum
Grey — 692914 SW8 1/2″ I.D.
Black — 692915 Code Description Code Description 6B 3/8″ BSPG (B**-2-6B) Steel
Coil Nut: C Conduit D010 10 VDC
A6B 3/8″ BSPG (B**-2-A6B) Aluminum
DSH081C / DSH091C Series — 118127-00 D DIN 43650 D012 12 VDC
DSH081N / DSH091N Series — 118194-00 P Double Spade D024 24 VDC ** Specify size 08 or 09.
Nitrile Seal Kit: S Double Screw A120 120 VAC NOTE:
DSH081 Series — SK08-2 W Double Wire A240 240 VAC If system pressure does not exceed 210 Bar
DSH091 Series — SK09-2
WP Waterproof (3000 PSI), aluminum bodies can be used.
Fluorocarbon Seal Kit: Double Wire Higher pressures require steel bodies.
DSH081 Series — SK08-2V
Notes: See Series 08 and 09 Coil Data Sheet.
DSH091 Series — SK09-2V For other coil voltages and terminations, consult factory.
S8 Coil applies to all terminations except WP.
SW8 Coil applies to WP termination only.

dsh081.pm6.5, bl, ll

Parker Hannifin Corporation


Hydraulic Valve Division
Hydraulics DC39 Elyria, Ohio 44035 USA

You might also like