You are on page 1of 1

a The 0grammable Timer

ON/OFF o can not setting overlap but


should bnme after contact 15 seconds,
Multi-functional Igita a n d control on-off
have ring bellprogram groupP ac
Ccording to the time sequence.(If setting same ONOFF wil weekly or daily, on-off manually
b. When function Can set 20 program, cycle or daily, and control on-off mant
groups
groups on-off
on-O cycle weekly
c.
view the set number
setting is finished.ect.press ( loto view program, ~

Press pre ONor the set number ofof ONiOEE


ONIOFF and time, it be modified follow the Umes pulsation 1s 99min 59sec
59sec
terface ON or OFF
enter to the interface
Of program,
program, press
and the d approp With co time range setting within
press "MANUAI"
"MANUAL" to10 clear the ON
cear or OFF time of cunent Own function, ime (1Hours) manually
2.2 20 u grou Can set
failure
pulsation function setting ("P" flashes on
Daylight Savingtravel time as usual if power
screen when
Step opening) u m battery, and s e c sA ts3 sec) every day
Button ume corection(-3 industrial installation
DII for construction and
sec Standard rails suitable
Hold both H+
and M+ for Programming
2 Enter into the Products can be
pulse width setting, display as 0:00 and P selecteo 16A, 20A)
ress H+, M+ and 9 at the same time
3 Set the
pulse width: min/ s (max 59 min 59 sec)
Press both and Manual Technical data
puse
the P on Rated voltage: AC220V 50Hz Power failure memory 3year
Press width setting is completed, the screen flashes
Ener into
Press H+M* timing pulsalion Voltage range: 190-240V Contact Form: 1 group conversion
ON(Display 1 ON)(Press again for
Set ON time the sEd
6 Number 20 groups, minimum 1 min consumed power:
Press D+ of on/off
program setting: s5VA(16A) 7.5VA(20A)
Same setung every day,
MO-FR. MO-SA, SASU,
t is
Number of 20 times, 1 sec-59 min 59 sec Electrical life:
same MO.WE, TH-SA, MO WE FR. TU TH SA (" - pulsation setting: 10times
Repeat step 4-6 every day, do
not press D+ and skip this step)
Contact load capacity: Resistance load: 16A/ 250V AC CoS p=1 Mechanical life:
Set the pulsation time of 10times
Press both H+ and M+ 2nd to 20th groups(or press to exit) ind uct ve load:10A/ 250V AC COS o=0.6
Exit the pulsation function, the Countdown time: Work temperature: -10 +50 °C (non-icing)
When setting is
finished, pres t o view the set display P will be disappeared sec- 99min59sec
b. Press Contact resistance between Ambient humidity: 35 856 RH
s100m2
enter to the interface number of pulsation and the time, it be modified follow the contacis
pulsation program, press "MANUAL" to appropriate selup steps
clear the pulsation time of current group and Insulation resistance between contacts 2100MO Storage temperature: -10 +60 °C
2.3 then display
Countdown function setting Timing error: St2 sec/day(25C) About 125g(16A)135g(20A)
(""d" displayed at bottom left corner of
screen) Weight:
Step Button
Programming Wiring drawing and External dimension
Hold both and O for 3 sec Enter into the countdown
T
2 setting. "d" displayed at bottom left corner,
press and H+/M+ displayed as 0:00 Unitmm
at the same time Set the min and sec of countdown
3 Press MANUAL
respectively (duration range: 1sec-99min59sec) U
Start the countdown function
4 Press
Halfway reset and wait to start the countdown again
5 Hold both and for 3sec Exit the countdown 16A product 20A product
seting. "d" at bottom left corner will be Wiring diagram Wiring diagram
disappeared
3. Manual daylight saving time (DST) display time
setting LOdd L

Step Load (
Button
Programming max36.0-
setting Hold both D+ and M+ for 3 sec naxoo
The
at
present time will increase 1hour("1h" Setting method
displayed the bottom left corner of the
cancel Hold both D+ and M+ for 3 sec again screen) If there is
DST will be canceled and back to the no display for the first time,
present time press "RESET".(press botn Tor 3 seconds, then the
Note: This
"D* and "H product will be turned off and all will be lost.
setting only set present time displayed. The ON/OFF time of But day corection parameters, accumulated operating times and action times are setting
not
reserved.)
If the
program or pulsation has been set is
program needs to run according to DST, set it in the setting program. changed. ON/OFF 1. Setting display time(present time):

Step Button
4.
programming
Automatic correction of time error Holdand then press H+ on
daily("1d" dis play at bottom left corner of HOUR increases the screen, press H+
screen) continuously, the hours increase
Step Button Hold and then press M+ MINUTE increases on the screen,
Programming continuously press M+, the minutes
increase
Press both MANUAL and Hold and then press D+ Mark of WEEK moves on the sCreen, preSs D+
Enter into time corection, screen display:1d-00 (setting 3 continuously to choose the week
Press D+
range-3-3sec)
Set the number of
seconds to The timer is 24 hour system when turned on, hold 9 TOr Sec 1o ConvErt o
urs
compensate each day. The program is incremented or system With "AM" showed on
decremented by 1 sec again to convert to 24 hours system and the "AM on the upper left corner will be the upper left corner. Hold "" for 5
Press
second(For example, displayed as 05 refer to increase
0.5 seconds;-20 refer to reduce 2 seconds ) disappeared.
The setting is
confirmed and exit
2. Timing setings (2.1,2.2 and 2.3three functions can not be used at the same time)

5. Control ON or OFF manually (press "MANUAL") 2.1 20 groups setting of on/offfunction:


Screen Display Button
Step
Work state Programming
ON AUTO 1 Enter into timing ON setting
Automatic control and in the ON
state Press (display 1 ON)
AUTO OFF Automatic control and in the OFF state Press H+ and M+ Set ON time, press H*o
Setne nour, press M+to set the minute
ON Press D+ Same
wE
setting every day, MR, MO-SA, SASU,
Permanent ON and not controlled by the timer MO-WE, TH-SA, MO FR, TU TH SA (if it
same every day, do not press D+ and is
OFF skip this step)
4 Enter into timing OFF setting (displays 1 OFF)
Permanent OFF and not controlled by the timer
Press
5 Press H+M+ Set OFF time, press H+ to
Attention setthe hour, press M+ to set the
Same setting every day, MO-FR, MO-SA
minue
Please don't use in the 6 Press D+ SA,
place w dust, corrOSIve gas, direct sunlight or rain. SA SU, MO-WE, TH-SA, MO WE FR, TU TH SA (if it is
same every day, do not press D and skip this s
the
Please store and use in tne conditions or raled voltage with the snecfied temperature and
humiaily Repeat step 1-6 Set the ON/OFF time of 2d to 20th
Froduct design and specifications mayoe be changed witho groups(or press to
t notice exit)

You might also like