Service Interval Service Activities (Replace parts if necessary) Time Required
Maintenance 1 • Inspect mechanism 30 min / TR490-491
o Springs 1 hour / TR492 (Every 6 months for o Bearings Standard Use or Every o Cams 3 months for Intense o Bolt assembly Use) • Inspect and adjust all limit switches • Inspect and adjust shock absorbers • Inspect and tighten all bolts o Add Loctite™#242 on bolts as needed • Measure main voltage (120V) • Measure low voltage (24V) • Inspect and clean logic controller • Verify all fuses • Inspect all electrical connections and cables • Inspect heater • Inspect anchors • Clean all the inside of the canopy with a vacuum • Inspect door locks • Test TR49X in entrance and exit
Part kit required for Maintenance 1 – per gate: None