COLUMN SCHEDULE

MARK SIZE REINFORCEMENT / REMARKS

FILLED CELL #5 BARS IN GROUT FILLED MASONRY BLOCK


SPACED AS SHOWN, BUT NO GREATER THAN
48" O.C.
BD21029038001
SC-1
8" X 12" CONCRETE (4) #5 BARS WITH #3 TIES @ 8" O.C. WITH 05/10/22
STARTER COLUMN #5 HOOKBARS SIMILAR AS SHOWN IN A/S-3

8" X 27" CONCRETE (8) #5 BARS WITH #3 TIES @ 8" O.C. WITH
SC-2
STARTER COLUMN #5 HOOKBARS AS SHOWN IN DETAIL A/S-3

C-1 8" X 12" (4) #5 BARS WITH #3 TIES @ 8" O.C.

C-2 8" X 8" (2) #5 BARS WITH #3 TIES @ 8" O.C.

NOTES:
· LAP ALL REINFORCING STEEL 48 BAR DIA.
· HOOKREINFORCEMENT STEEL AT TOP OF UPPER MOST BEAM
· REFER TO TYPICAL COLUMN REINFORCING DETAILS THIS SHEET

COLUMN REINF. DETAILS TYPICAL COLUMN REINFORCING DETAIL


SCALE: 1/2" = 1'-0"

SC-1 C-2 SC-2


C-1

FOUNDATION LEGEND

STRUCTURAL CONSULTING
9719 S. DIXIE HWY, UNIT 2 Off: 305.609.3652
Miami, FL 33156 CA 28548

FOUNDATION CORNER DETAIL


SCALE: 1/2" = 1'-0"

B
S-3
Digitally
1
THOM signed by
THOMAS MOE
S-3
AS Date:
2021.12.16

MARK
FOUNDATION SCHEDULE
SIZE REINFORCEMENT
MOE 15:44:00 -05'00'
16" X 12" DEEP (2) #5 CONTINUOUS
WF-1
CONT. FOOTING BOTTOM BARS

#6 BARS @ 10" O.C. EACH WAY


3'-0" X 3'-0" X 1'-4" DEEP (BOTTOM); #5 BARS @ 10" O.C.,
PAD-1 PAD FOOTING EACH WAY (TOP)

8" X 8" DEEP (1) #5 BARS CONTINUOUS


TE-1 THICKENED EDGE BOTTOM BAR

NOTES: TERMITE NOTE:

· SPLICES IN REINFORCING BARS SHALL BE NOT LESS THAN 36 BAR PRIOR TO PLACEMENT OF CONCRETE THE FILL INSIDE OF
DIAMETERS AND REINFORCEMENT SHALL BE CONTINUOUS AROUND ALL THE FOUNDATION SHALL BE TREATED FOR SUBTERRANEAN
S-3

A CORNERS AND CHANGES IN DIRECTION. CONTINUITY SHALL BE TERMITES BY A LICENSED PEST CONTROL COMPANY.
2

PROVIDED AT CORNERS OR CHANGES IN DIRECTION BY BENDING THE UPON COMPLETION A CERTIFICATE OF COMPLETION SHALL
S-3 LONGITUDINAL STEEL AROUND THE CORNER 48 BAR DIAMETERS OR BY BE ISSUED BY THE LICENSED PEST CONTROL COMPANY TO
ADDING MATCHING REINFORCING STEEL, WHICH SHALL EXTEND 48 BAR THE BUILDING DEPARTMENT CONFIRMING THAT THE
DIAMETERS FROM EACH CORNER OR CHANGE DIRECTION. BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR
THE PREVENTION OF SUBTERRANEAN TERMITES AND THAT
· TOP OF ALL WALL & PAD FOOTINGS TO BE 12" BELOW NATURAL GRADE (MIN.) THE TREATMENT IS IN ACCORDANCE WITH AGRICULTURE
NORTH AND CONSUMER SERVICES.

FOUNDATION PLAN COMPACTION SPECIFICATIONS

SCALE: 1/4" = 1'-0" SUB SOIL TO BE FREE FROM ALL DETRITUS


MATERIALS AND COMPACTED WITH A HEAVY
SELF PROPELLED ROLLER TO 95% MAX DRY
DENSITY PER ASTM D-1557 WITH NO LESS THAN
10 PASSES IN EACH DIRECTION.

FILL SHALL BE PLACED IN LIFTS NOT GREATER THAN


12" LOOSE THICKNESS FOR MATERIAL COMPACTED BY HEAVY
COMPACTION EQUIPMENT, & NOT MORE THAN 6" INCHES
NOTES TO CONTRACTOR: LOOSE THICKNESS FOR MATERIAL COMPACTED BY HAND -
· ELEVATION IS IN REFERENCE TO THE FINISHED FLOOR. TOP OF SLAB TO BE OPERATED UNITS.
COORDINATED WITH FINISHED MATERIAL. TOP OF ALL WALL FOOTING ELEVATIONS
SHALL BE 12" BELOW FINISHED GRADE. SOIL STATEMENT
· CONTRACTOR SHALL COORDINATE STRUCTURAL DRAWINGS WITH ALL ARCHITECTURAL, SOIL AT THIS SITE IS MIXTURE OF ROCKAND SAND,
ELECTRICAL, MECHANICAL AND PLUMBING DRAWINGS AND NOTIFY THE DESIGN TEAM ADEQUATE TO SUPPORT A DESIGN LOAD OF
OF ANY DISCREPANCIES. 2,000 P.S.F. AT TIME OF CONSTRUCTION A LETTER
· CONTRACTOR SHALL VERIFY ALL DIMENSIONS ELEVATIONS AND SLAB FINISHES PRIOR ATTESTING TO THIS FACT WILL BE SUBMITTED BY
TO COMMENCEMENT OF CONSTRUCTION. THIS ENGINEER.
· ALL POST ANCHORS TO BE GALVANIZED OR STAINLESS STEEL
· CONTRACTOR TO SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL FOR ALL INTERIOR CONCRETE SLAB OVER EXISTING
APPLICABLE ITEMS INCLUDING, BUT NOT LIMITED TO: WINDOWS & DOORS; ROOFING, ALL

·
DOWEL BARS SHALL BE SET IN HILTI HIT 200 EPOXY ADHESIVE, OR APPROVED EQUAL
ALL EXPANSION ANCHORS TO BE HILTI KWIKBOLT TZ, OR APPROVED EQUAL AND SHALL
INSTALL ± 4" CONCRETE SLAB OVER EXISTING CONCRETE SLAB
REINFORCED WITH 6 X 6 X W1.4 X W1.4 WELDED WIRE FOUNDATION PLAN
REINFORCEMENT PLACED 1 1/2" FROM TOP OF SLAB.
BE GALVANIZED, STAINLESS STEEL OR ZINC PLATED

S-1