2. Answer:
a.) V - E -Ir n Volt
= 6 - (.5 X .30) = 6 - .045
= 5.955 Volt.
b.) V = 6 - (2 x .5) = 6 - 1
V = 5 Volt.
3. Answer:
4. Answer:
a.)
= .0037
b.)
𝑄
𝐷= 𝐶𝑜𝑢𝑙𝑜𝑚 𝑏 𝑀𝑒𝑡𝑒𝑟 2 𝐷 = 60 𝑋 106 500 𝑥 106 12. 𝐶
𝐴
6. Answer:
1.) Jumper cable in the switch Button
7. Answer:
8. Answer:
60%
9. Answer:
0 X 3.0 Meter wiring code (page.169)
10.
Answer:
1.) VA Compute.
VA = V x 1.732 x 1
VA = 210 x 1.732 x 1
VA = 363.72
2.) Computing continuous load
363.72 VA x 125% = 454.65VA
2xKx1xL 1.732 x k x 1 x L
11. Vd = CM
𝑉𝑑 = CM
12. Answer:
1.) Electrocution
2.) Arching
3.) Fire
4.) Shocking
5.) Explosion
13.
Answer:
➢ Lamp Limens = (Maintained foot-candle X area) / (cu X mf)
= 50 fc X (10m X 20m) / 0.38 x 0.75
= 50 FC X (200 / .285)
= 35,087.719 Lumens
➢ Each 40 watts fluorescent lamps have an output of 3200 lumens, the member of lamp will be
= Number of lumens = 35087.719 / 3200
➢ Since there are 3 lamps for each fixture, divide.
8.77/3 = 2.93 saying 3 Lamps for each fixture.
14. Answer:
1.5 mm2
15. Answer:
7.1.7 socket – outlet for a normal use must be positioned at a standard height of 300mm or
450mm above floor level or 100mm above work surfaces