Professional Documents
Culture Documents
Date: 12-June-2019
Description: Intergraph Smart® P&ID simplifies the process of creating piping and
instrumentation drawings. It is a data-centric solution, meaning a data model
is created and stored in an on-line database. The graphical representation is
the user's view into the data, allowing for synchronization of both the graphics
and the data model.
System Requirements
Important: Beginning with Windows 10 and Oracle 12.1.0.2, Microsoft and Oracle will enforce
the Internet Host Table Specification RFC 952 which mandates that component hostname labels
can contain only alphanumeric characters. Hostnames using underscores (‘_’) are not allowed.
Refer to Oracle Support Articles 1603775.1 and 1957895.1 and Microsoft KB 101785.
For full details of system requirements, refer to the Hardware and Software Recommendations
section of the Smart P&ID Installation and Upgrade Guide in the Help\en-US folder of the DVD
Setup (SPPIDInstallGuide.pdf)
Version Compatibility
For up-to-date information on the software compatibility of this product in a standalone or
integrated environment, please refer to the Compatibility Matrix on the Hexagon PPM Support
Web site at https://smartsupport.intergraph.com/.
Log on and perform the following steps:
For information about authoring tool versions that work with a particular version of SmartPlant
Foundation, select SPFoundation in step 3.
Special Instructions
Refer to the Smart P&ID Installation and Upgrade Guide (SPPIDInstallGuide.pdf) for installation
and upgrade details.
Documentation
General
Use the Help menu to access the help files and Printable Guides for this product.
For the latest support information for this product, connect to https://hexagonppm.com/ppm-
support.
Printed documentation is not available for separate purchase.
Training
To register for training on Hexagon PPM products, call Training Registration at (800) 766-7701
in the U.S. Outside the U.S., call (256) 730-5400 or contact your local Hexagon PPM office.
For current information on training, connect to http://www.intergraph.com/ppm/training/.
Customer Support
For the latest Support Services information for this product, including solutions to known
software issues, connect to https://hexagonppm.com/ppm-support.
To open service requests outside the U.S., please contact your local Hexagon PPM office.
Fixes
Automation
TR PB:96390
Piping point properties can now be updated using Llama
TR PB:105738
A drawing can now be renamed using Llama
TR PB:107525
A draft.exe error does not occur anymore upon closing drawing after accessing
LMADatasource.CodeList
TR PB:134211
A display set for a drawing can now be updated successfully using VB.NET Automation
TR PB:151612
LLAMA Automation performance accessing Hydraulic Circuits is comparable to SPPID 2014
TR PB:156049
Using Plaice, partner OPCs can now be placed successfully from the stockpile after placing
OPC
TR PB:175218
When changing a drawing’s Drawing Number with LLAMA, the drawing now goes Out-of-Date
for Drawing Property Changes
TR PB:190386
When two open drawings and SPPID are closed simultaneously draft.exe now closes properly
TR PB:199450
When using the Drawing Validation available on the Smart Support website, if you delete a
multi-rep from Model the drawing does not go into a recreate state anymore
TR PB:209239
Placing a Flange on a Valve is not creating a constraint violation anymore when using a
validation dll
TR PB:213362
Placement.PIDDeleteItem does not throw a Type Mismatch error anymore when deleting
InstrLoop or Mechanical (Equipment) from the Plant Stockpile
TR PB:215410
A fix was made such that a Llama program does not crash anymore due to extensive memory
usage
TR PB:218076
The sample Source Code .NET – SPImportImpl can be run successfully
Documentation
TR PB:114765
Misleading information about SPPID publish has been clarified
TR PB:162699
Insulation Manager Help documentation now clearly states that the default
temperature/thickness units set in the Options Dialog Box apply to Insulation Manager only.
TR PB:163446
The name of the 'Equipment - New' filter has been corrected in the Drawing Manager Help -
Saving Drawings topic
TR PB:163687
The SmartPlant Resource Path in the Options Manager Help > Settings now correctly points
to the SPPIDDataMap.xml file
TR PB:176049
The description of the Coincident 1:1 setting located in the "Files Tab" page of SmartPlant
P&ID Help has been corrected
TR PB:190821
Detailed documentation has been added for how to create Break Nozzles
TR PB:217231
Documentation has been corrected for the Subscribe Access functionality in a disconnected
Workshare environment
Drawing Manager
TR PB:51646
Confusing error message has been revised for specific check in scenario
TR PB:88290
Draft.exe has been fixed to release memory when drawings are closed
TR PB:104011
The icons at the top of the Fetch dialog in Drawing Manager are now visible when the dialog
is first opened
TR PB:111168
Associate Version is now disabled on Revision Properties dialog
TR PB:114431
The Revision Date has been fixed to display correctly when the date format is "dd.mm.yy"
TR PB:119057
Drawing files are now placed in the correct folder when a plant group has been renamed and the
drawings have been updated
TR PB:151020
The Schedule Update Drawing task now observes the hierarchy selection made for the task and
only updates drawings in the selected plant group
TR PB:154960
Drawing names are now properly updated in the Satellite Plant when updated at the host
TR PB:160190
The drawing name has been added to the SmartplantPID log file for a problem that occurred
with a particular drawing during the Update Drawing operation
TR PB:166150
Simply applying a display set does not allow the user to create a new version anymore
TR PB:173552
The Revision Date now shows correctly in the Revision Properties window when a “Long Date”
format is used
TR PB:173967
Sorting has been fixed to work with “Filter” and “Include Subnodes” on
TR PB:175602
The software has been fixed to not incorrectly deactivate the Include Subnodes button in a
sequence of operations
TR PB:184484
A drawing containing more than 1000 OPCs can now successfully be checked in to the As-Built
TR PB:194512
Titleblock Fields w/ Special Character “&” now display successfully with Save As AutoCAD
DWG
TR PB:196660
The Schedule button has been disabled when printing to the SmartPlant PDF Converter
TR PB:196788
A fix has been applied to allow the user to schedule and successfully print to local (not
redirected) printers
TR PB:201036
Drawing Manager has been fixed to not crash anymore when modifying drawing properties
TR PB:201866
Drawing versions can be successfully retrieved in succession
TR PB:204194
The error message has been modified to clearly indicate that the drawing is open in the As-Built
TR PB:208676
Importing 50 Drawings of Size 13 MB does not cause Drawing Manager to crash anymore
TR PB:209413
Update Drawings has been fixed to resolve moved OPCs that have been moved back and forth
between plant and drawing stockpiles
TR PB:213049
Drawing Manager has been fixed to handle the dd.mm.yy format correctly on the Revision
History Properties dialog
TR PB:213309
The user can now check the specific drawing in this dataset into the As-Built
TR PB:215020
The software now allows the user to connect to a newly created connected Workshare Satellite
Plant
TR PB:216277
The pipe run’s construction status does not receive the default value anymore during Update
Drawings but retains its value
TR PB:216364
Update Drawing does not change the Construction Status of the lines in this specific dataset
anymore
TR PB:216602
A fix has been made to retain the linked border when drawings are copied and pasted in the
project of an As-Built plant
TR PB:218497
Drawings with OPCs in the drawing stockpiles can now be successfully retrieved by the host
plant using Get Latest from Local
TR PB:219811
Drawing Manager has been fixed to successfully import drawings with paired OPCs
Options Manager
TR PB: 107182
The Reference Data Upgrade has been fixed to upgrade all symbol files to the latest RAD
TR PB: 158912
A fix was made where the Piping OPC will correctly retain the black symbology upon selection
TR PB: 167202
Options Manager does not display a read-only message anymore for the style file if Drawing
Manager or a drawing is open
TR PB: 192474
Upgrade Reference Data does not display an error anymore with an OOTB plant
TR PB: 206313
Upgrade Reference Data now complete successfully with the referenced dataset
TR PB: 207593
A fix has been made to successfully save the changes to Options Manager after a custom
symbology filter has been added for the Revision Cloud
Rule Manager
TR PB: 162587
Consistency criteria of a rule are not cleared anymore if the consistency tab is opened before
saving a modified rule
Smart P&ID
TR PB:53103
The software behavior has been changed such that filtering now works correctly in the EDE with
various Nominal Diameter values
TR PB:71900
An issue was addressed with display of OPC's in the EDE being slow
TR PB:72650
A problem with a cloned “Test Sys Item Tag” label to which a property has been added has
been resolved
TR PB:72980
Display Sets are now displaying correctly when properties are changed.
TR PB:78552
The software has been fixed such that the property value is set to NULL when a driving label is
removed
TR PB:82547
A problem with the Revision Number and the Hold Revision Number Property in the equipment
report
TR PB:87427
Inserted objects do not disappear anymore when the drawing template is changed
TR PB:89221
The software now enforces the character limit of 240 in the Equipment Description field
TR PB:97792
The Contract and Hydro Test Package Item Tags are not incorrectly displayed in the Package
Item Tag field anymore in the EDE
TR PB:99245
An Instrument OPC now shows an inconsistency for "Cannot evaluate Consistency"
TR PB:103777
A Titleblock label that reports 'Plant' properties such as Description now reports these
properties if one or more projects also have values for the property
TR PB:105454
Certain parametric symbols whose size has been changed do not revert back to their original
shape anymore when the drawing is recreated
TR PB:105644
Graphics are not flipped anymore after translation (Save As) to AutoCAD
TR PB:108302
Symbols with Multiple LineStyles/Pattern now translate correctly to AutoCAD
TR PB:109985
The EDE command 'Move to Different Stockpile' has been fixed to work correctly
TR PB:113896
When overwriting a file with the same name Save as PDF now takes into consideration and
handles properly files that are open
TR PB:113915
The software has been fixed to honor the default symbology width for new primary piping
TR PB:114289
TR PB:128321
Igr files inserted into the drawing template are now stored on the DrawingBorder layer
TR PB:114842
All characters typed into a string property field in the EDE are properly retained
TR PB:118866
A problem with an Inline/Offline Instrument's PipeRun/SignalRun ownership has been resolved
TR PB:119850
The problem of an icon assigned any custom button appearing dark grey/black when re-entering
P&ID is not seen on the new platform
TR PB:124981
Performance has been improved with Plant Editing when editing items in huge drawings
TR PB:125172
The default format set as Pressure-MPa in Data Dictionary Manager is now reflected correctly
in the Properties window
TR PB:128536
Auxiliary Graphics are not displayed in the Typicals view anymore
TR PB:130428
PDFs can now be printed successfully in a Citrix Environment
TR PB:131198
A fix has been made such that labels places on Area Breaks now correctly show the property
values.
TR PB:131774
Loops residing in the Plant Stockpile are not moved to the Drawing Stockpile anymore when an
associated instrument is moved to another drawing
TR PB:133835
Plant Group item tags now remain editable when labels are used to display the plant group item
tag
TR PB:135525
An issue with copying rows and columns while selecting a large number of rows or fields has
been fixed
TR PB:135958
Deleting a property value in the EDE or in Properties grid now sets the property value to null
TR PB:137261
There is no overlap anymore between Item Type pulldown and View Menu pulldown icons on
Japanese Windows 10
TR PB:138019
An error message does not display anymore when updating symbology
TR PB:139969
Description attributes have been added to all ducting and piping points on items of type
Instrument
TR PB:150713
Double Clicking while holding Ctrl (or Shift) key does not cause the Modeler to crash anymore
TR PB:154166
Placing an assembly does not change the background color to the previous setting anymore
TR PB:154675
The space between the symbol and the leader line has been minimized for most symbol
locations
TR PB:154891
The software has been fixed to now allow creation of an Area Break square of size 3mm.
TR PB:155856
Pipe Spec Access with Spec Revisions does not overwrite user entered values anymore
TR PB:155935
Nominal Diameter values can be typed into the field manually again for most values
TR PB:157549
Running servicepids twice does not render drawings out of date anymore due to the need to
recreate of another user accessing them
TR PB:158785
cmdlpcheck.dll can now successfully be run on an Oracle plant.
TR PB:159696
Copied display sets or folders can be pasted to the top level of the tree again
TR PB:160410
All numbers display fully in the quick pick tool on Windows 7 Aero themes, Windows 7 Basic,
Windows 10, and Windows Server 2016
TR PB:163204
The software has been fixed to where compound filters with a combination of simple filters at
least one of which contains PMC criteria work correctly when used in display sets
TR PB:164461
A fix has been made to provide consistent solutions on the Consistency Check dialog, observing
the rules of being able to write to the Catalog
TR PB:166386
When the border line type of SmartFrame is set, the information is now stored correctly in
database
TR PB:166870
Codelists errors have been fixed, allowing all reports to run successfully on an MSSQL satellite
TR PB:168304
The software has been fixed to show the revision label as blank if no Revision Date has been
assigned to the revision
TR PB:170274
The upgrade has been fixed to retain linked igr files in the state they were in (cropped) in the
previous version
TR PB:170508
Any plant item with item tag validation now automatically gets the next sequence number
from Options Manager settings
TR PB:174010
Gap Styles now appear in MicroStation the same as they do in the SPID file
TR PB:174181
Items assigned to a plant group in the plant stockpile can be moved to another drawing
without moving every item assigned to the group
TR PB:174185
The software has been fixed to not show "Ghost" symbols when placing an assembly
TR PB:174250
An issue has been addressed with performance degradation after upgrade with Logo placed as
a symbol
TR PB:174294
Advanced Filters can now be customized and used successfully in the Representation view of
the EDE
TR PB:175071
Addressed performance issues related to assembly placement
TR PB:175221
Addressed a problem with pipe spec validation using SRD
TR PB:181654
The software has been fixed to correct the propagation issue from a process pipe line to a
nozzle
TR PB:182118
A problem with the volatile Filter in the EDE has been corrected
TR PB:184079
An issue has been fixed with a Polish character and a multi-line Equipment description
TR PB:185700
Replacing Primary Piping with Secondary Piping does not delete the Plant Group Name
anymore
TR PB:186228
Inconsistencies now show correctly for TEMA heat exchangers
TR PB:186244
The SPID Modeler does not crash anymore after inserting a MicroStation V8 DGN file with 3D
Elements
TR PB:186264
The cursor does not move to the top of Properties window anymore after assigning select set
values
TR PB:187560
A problem with a linked Excel file receiving automatic updates has been fixed
TR PB:187674
Additions to the OPC Brief/Bulk List are now correctly reflected in the Properties Window
TR PB:187721
All parts of a DGN file are now displayed when the file is inserted into drawing
TR PB:188157
An issue has been addressed with frequent run-time errors when opening a drawing
TR PB:188249
The EDE reports have been fixed to honor the particular view selected in the EDE
TR PB:189526
Users is now able to delete any item in the plant or drawing stockpile from the EDE while using
Norwegian, Bokmal (Norway) Format
TR PB:189754
A problem has been fixed with highlighting incorrect items on the Consistency Check Dialog
TR PB:189789
Item 1 Property now displays property names for the Process Pipe Run To Process Pipe Run
rule
TR PB:190777
A problem has been fixed where "My Display Sets" entries Ddsappeared after upgrade
TR PB:191128
OPCs are now deleted successfully in a plant using customized validation
TR PB:192212
The SPID Modeler does not crash anymore after inserting a MicroStation V8 DGN file with 2D
Elements
TR PB:194014
PlantItemValidation now occurs when the Option Code is set to Null using the Option Code
dialog
TR PB:194015
A fix has been made where the SmartText Label Set to "As Entered" displays using the correct
font
TR PB:194394
The format Upper Case - Variable Length is now honored in the Description dialog box
TR PB:195137
The problem with duplicate Labels in Template After Update Drawings and Recreate has been
corrected
TR PB:195259
A Commit Failure or Undo Processing Failure does not occur anymore when refreshing a
drawing
TR PB:196010
A problem has been addressed where an inserted and cropped DGN file moves after recreate
TR PB:196148
The size of a cropped Smartframe is retained after a drawing is recreated
TR PB:197278
Changing the template of an existing drawing does not remove inserted objects with the
indicated workflow
TR PB:197537
A linked Drawing Border does not disappear anymore after copying and pasting a drawing
TR PB:197848
CheckSymbolsCmd.dll has been fixed to find symbols with incorrect Class, Subclass, and Type
TR PB:197911
An issue has been corrected with Save As DGN ignoring symbology settings for some Piping
Components
TR PB:198164
Update Drawings has been fixed to resolve "Moved OPCs"
TR PB:198444
Solid Fills are now correctly translated to Microstation
TR PB:198505
An problem has been corrected with certain drawings in a plant hanging during Re-create
TR PB:198553
Additional Inserted Objects are not created for mapped symbol when importing SmartSketch
files
TR PB:198620
A Segment Break can now be placed between an Instrument and Signal Run
TR PB:199715
An issue has been addressed when assigning many items to a package in MS SQL Server
TR PB:201020
The user can now successfully copy and paste items in a specific drawing in the supplied
dataset
TR PB:201380
Irrelevant property break warnings are not displayed anymore in the database constraint report
TR PB:201876
The Modeler does not crash anymore when selecting Bold or Italics in the EDE Display Settings
TR PB:204042
An issue has been addressed with the drag and drop error message, "The symbol link already
exists"
TR PB:204959
A problem has been fixed concerning inconsistent Instrument Class/Type when a drawing is
reopened after symbol replacement
TR PB:206175
Values assigned to the 'Revision Text' property now persist after reopening the drawing
TR PB:206372
Problems with a particular drawing that failed to re-create a drawing and could not be opened
have been addressed
TR PB:207508
Issues with property values being displayed in inappropriate places have been resolved
TR PB:209340
Custom Toolbars have been replaced with Favorites and a Quick Catalog in the new Catalog
Explorer
TR PB:209687
The shortcut menu now correctly displays when multiple labels are selected
TR PB:211536
An issue of more than 80% of drawings in a particular plant having bandaided items has been
addressed
TR PB:212285
The Delete key can does not delete a folder in the Catalog Explorer in P&ID
TR PB:213616
Hidden Object information for all symbols now goes to the HiddenObjects layer in AutoCAD,
regardless of the filter-to-layer mapping that has been defined.
TR PB:214070
The software has been fixed to show all filters in the Display Set dialog
TR PB:215359
Registry keys are not created anymore by the Hotfix setup
TR PB:215562
A problem has been addressed where most pipe runs in a project drawing have invalid claims
after "Verify for checkin"
TR PB:216177
A problem has been fixed in the EDE such that the Instrument looptag dialog now displays
properly and instrument can be assigned successfully
TR PB:217871
Unapproved Inconsistencies do not change to Approved anymore after the drawing is recreated
TR PB:217907
With a keyboard update of the Nominal Diameter, the user now has to hit Enter or click outside
the field in order for the software to correctly register the new value and reflect it in the label
TR PB:218527
Plant-wide or entire database report does not crash anymore with an MSSQL database
TR PB:218998
A fix has been made where a workflow with “Move Partner OPC” does not result in commit
failure which require a recreate of the drawing
TR PB:219485
Reports can now be run successfully on a machine with SPID 2019 and SEM 2019 installed
TR PB:205823
SPPID is able to connect to an SRD Server for Oracle 12c or 18c if Oracle data access dlls are
registered to the GAC
Smart Integration
TR PB:117766
The Metadata adapter contains all information necessary to publish process case data from
SPID
TR PB:132985
The pipe run property "ScheduleOrThickness" is now successfully published when mapped to
"ScheduleOrThickness" under MapForPIDPipingConnector
TR PB: 153193
The unit 'hp_550ft-lbf/s' UoM for the Electrical Requirement property on an equipment is now
published with the correct unit
TR PB: 154540
A message now displays to the user if a selected task which includes one or more Create
items whose PBS is not the same as current drawing’s plant group
TR PB: 165656
A software fix has been made to generate Delete tasks for instruments deleted from SPI
TR PB: 169366
The SPPIDdatamap.xml has been corrected such that Area UoMs are now published with the
correct unit
TR PB: 190491
Cancel and Merge (Project) commands are now correctly enabled in an integrated
environment where both SPID and SPF are installed
TR PB: 192985
A fix has been made to enable the user to compare a current PID drawing with a published
version of the drawing to SPF
Open Problems
Automation
TR PB: 158600
Properties do not propagate from Pipe Run to Piping Component in certain scenarios
Workaround: User (non-admin and admin) has to run the Llama application while the
drawing is opened. Also the application cannot re run by right clicking and selecting "Run as
Administrator"
TR PB:168241
When performing Automation placement of Pipe Runs, immediately using the AutoGap or Gap
Now commands do not work and no errors are reported in the log files
Workaround: Place a valve on one Pipe Run and delete the valve. AutoGap and Gap
commands work now
TR PB:169118
When deleting multiple Inline Components with PIDDeleteItem, Pipe Runs are not mending
and the drawing is left in a state of broken relationships and missing ISPItems
TR PB: 171441
Properties cannot be propagated using Llama in MS SQL plants if the drawing is in closed
state
Drawing Manager
TR PB: 79325
Incorrect data is displayed in XML Title Block labels when the drawing is printed from
Drawing Manager
TR PB:131261
Updating all drawings in a large large dataset leaves many drawings out of date
TR PB:132313
Constraint Violations occur when importing a drawing from a Source plant to a Target plant
Workaround: Create an assembly of the drawing in the Source plant and place it in the
Target plant
TR PB:163434
When copying and pasting a drawing Area/Unit prefixes are added to the instrument’s Tag
Sequence Number
TR PB:219469
When performing Copy/Paste drawing, not all property break labels are created properly in
the pasted drawing, resulting in values propagating across the break when they should not
Options Manager
TR PB: 107185
When upgrading the Reference Data using Tools > Upgrade Reference Data, the Template
files are not upgraded to the latest RAD version
TR PB: 160372
After creating a new plant with customer’s data dictionary template (DDT) and associating
SPPID the customer cannot revise an existing or new SPPID document to SPF.
TR PB: 160750
Moving the order of the filters (using Move Up or Move Down) in Options Manager >
Symbology does not trigger Update Drawing and cause the drawing to be out of date
Smart P&ID
TR PB:96131
Deleting a reducer from a pipe run after mirroring the reducer breaks the pipe run
TR PB:107861
Copying Fluid Code data to resolve an inconsistency does not reset the Fluid System value
Workaround: always fix both the Fluid System and the Fluid Code inconsistencies
TR PB:115353
A clear message is not presented when a drawing fails to open in certain situations,
preventing the user from being able to fix the problem
TR PB:127676
A Commit failure occurs when a Multi-representation equipment is deleted
Workaround: close and reopen the drawing or update the drawing before deleting the Multi-
representation item
TR PB:132324
After deleting the concentric reducer on the horizontal pipe run then part of the pipe run is
deleted but the remaining pipe run is broken into two pipe runs
TR PB:141195
The font size set in the pidmstn.dgn file for a specific font and used for translation to
MicroStation .dgn is not honored
TR PB:142312
The logo files (.tif) inserted and linked into the embedded .igr border template file do not
translate correctly with Save As to AutoCAD .dwg format
TR PB:143863
The unit conversion from m^3/hr to nm^3/hr is incorrect and ambiguous
TR PB:144289
It is not possible to embedding TIF images in a drawing
TR PB:149902
Some symbols dissolve to Individual Components w/ Save As MicroStation when moved in
the .dgn file
Workaround: fence select the objects before moving them in the .dgn file
TR PB:151884
TR PB:152253
Changing a drawing template using File > Page Setup restores the original template after
recreating the drawing unless SmartSketch is installed on the machine
TR PB:153984
After changing the border of drawing using File > Page Setup and recreating the drawing, the
border is shifted from its previous location
TR PB:154906
Mirroring or rotating a Select Set without the Copy option moves and/or shifts labels
TR PB:157240
The duplicate tag report logs duplicate item tags across different Item Types
TR PB:160370
Symbology is not honored with a filter for all Plant Items, except Signal Lines, using the Supply
By property
TR PB:160819
A segment break label (end of group) cannot be placed on a primary pipe run between a flange
and a nozzle when the endcap for Primary Piping is flat
TR PB:163931
There is an intermittent problem with the toolbar buttons being disabled just after opening a
drawing in the Modeler
Workaround: double click the title bar above the toolbar and drag the empty ribbon bar to a
different position
TR PB:166411
Single Heat Tracing using a style of ‘Dotted’ does not display on pipe runs in one particular plant
TR PB:167360
Data loss is experienced with a particular plant after recreate in a German Environment only
TR PB:214928
Inconsistency indicators do not display in a particular SQL plant
TR PB:219621
In the Consistency Check dialog, no solutions are listed to resolve the inconsistent flow
direction that is detected between a delivered ducting inline instrument and a duct run
Workaround: manually resolve the inconsistencies in the property grid for the instrument
TR PB:219915
Editing properties in the Properties Grid or moving a large group of objects outside the
drawing border causes the Modeler to crash in Citrix
TR PB:219921
TR PB:219989
TR PB:219991
With a particular plant the modeler crashes intermittently but without specified or
reproducible workflows
TR PB:221038
While doing SPPID Map file synchronization the Intergraph SmartPlant Schema Component
stops working
TR PB:221486
With a particular Oracle dataset “Draft has stopped working” displays upon opening any
drawing in the plant
TR PB:221526
Drawings cannot be opened in a particular MS SQL plant
TR PB:221765
Compare and Refresh incorrectly reports that Case Data values are lost when a drawing is
check into the AsBuilt
Legal Notices
Copyright
Copyright © 1999-2019 Hexagon AB and/or its subsidiaries and affiliates. All Rights Reserved.
This computer program, including software, icons, graphic symbols, documentation, file formats, and audio-visual
displays; may be used only as pursuant to applicable software license agreement; contains confidential and proprietary
information of Hexagon AB and/or third parties which is protected by patent, trademark, copyright law, trade secret law,
and international treaty, and may not be provided or otherwise made available without proper authorization from
Hexagon AB and/or its subsidiaries and affiliates.
Portions of the user interface are copyright © 2012-2018 Telerik AD.
Documentation
Documentation shall mean, whether in electronic or printed form, User's Guides, Installation Guides, Reference Guides,
Administrator's Guides, Customization Guides, Programmer's Guides, Configuration Guides and Help Guides delivered
with a particular software product.
Other Documentation
Other Documentation shall mean, whether in electronic or printed form and delivered with software or on Intergraph
Smart® Support, SharePoint, box.net, or the Hexagon PPM documentation web site, any documentation related to work
processes, workflows, and best practices that is provided by Intergraph as guidance for using a software product.
Terms of Use
a. Use of a software product and Documentation is subject to the End User License Agreement ("EULA") delivered
with the software product unless the Licensee has a valid signed license for this software product with Intergraph
Corporation. If the Licensee has a valid signed license for this software product with Intergraph Corporation, the
valid signed license shall take precedence and govern the use of this software product and Documentation. Subject
to the terms contained within the applicable license agreement, Intergraph Corporation gives Licensee permission
to print a reasonable number of copies of the Documentation as defined in the applicable license agreement and
delivered with the software product for Licensee's internal, non-commercial use. The Documentation may not be
printed for resale or redistribution.
b. For use of Documentation or Other Documentation where end user does not receive a EULA or does not have a
valid license agreement with Intergraph, Intergraph grants the Licensee a non-exclusive license to use the
Documentation or Other Documentation for Licensee’s internal non-commercial use. Intergraph Corporation gives
Licensee permission to print a reasonable number of copies of Other Documentation for Licensee’s internal, non-
commercial use. The Other Documentation may not be printed for resale or redistribution. This license contained
in this subsection b) may be terminated at any time and for any reason by Intergraph Corporation by giving written
notice to Licensee.
Disclaimer of Warranties
Except for any express warranties as may be stated in the EULA or separate license or separate terms and conditions,
Intergraph Corporation disclaims any and all express or implied warranties including, but not limited to the implied
warranties of merchantability and fitness for a particular purpose and nothing stated in, or implied by, this document or
its contents shall be considered or deemed a modification or amendment of such disclaimer. Intergraph believes the
information in this publication is accurate as of its publication date.
The information and the software discussed in this document are subject to change without notice and are subject to
applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this
document.
The software, Documentation and Other Documentation discussed in this document are furnished under a license and
may be used or copied only in accordance with the terms of this license. THE USER OF THE SOFTWARE IS
EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN
ENVIRONMENT.
Intergraph is not responsible for the accuracy of delivered data including, but not limited to, catalog, reference and
symbol data. Users should verify for themselves that the data is accurate and suitable for their project work.
Limitation of Damages
IN NO EVENT WILL INTERGRAPH CORPORATION BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL
INCIDENTAL, SPECIAL, OR PUNITIVE DAMAGES, INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR
PRODUCTION, LOSS OF REVENUE OR PROFIT, LOSS OF DATA, OR CLAIMS OF THIRD PARTIES, EVEN IF
INTERGRAPH CORPORATION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
UNDER NO CIRCUMSTANCES SHALL INTERGRAPH CORPORATION’S LIABILITY EXCEED THE AMOUNT THAT
INTERGRAPH CORPORATION HAS BEEN PAID BY LICENSEE UNDER THIS AGREEMENT AT THE TIME THE
CLAIM IS MADE. EXCEPT WHERE PROHIBITED BY APPLICABLE LAW, NO CLAIM, REGARDLESS OF FORM,
ARISING OUT OF OR IN CONNECTION WITH THE SUBJECT MATTER OF THIS DOCUMENT MAY BE BROUGHT
BY LICENSEE MORE THAN TWO (2) YEARS AFTER THE EVENT GIVING RISE TO THE CAUSE OF ACTION HAS
OCCURRED.
IF UNDER THE LAW RULED APPLICABLE ANY PART OF THIS SECTION IS INVALID, THEN INTERGRAPH LIMITS
ITS LIABILITY TO THE MAXIMUM EXTENT ALLOWED BY SAID LAW.
Export Controls
Intergraph Corporation’s software products and any third-party Software Products obtained from Intergraph Corporation,
its subsidiaries, or distributors (including any Documentation, Other Documentation or technical data related to these
products) are subject to the export control laws and regulations of the United States. Diversion contrary to U.S. law is
prohibited. These Software Products, and the direct product thereof, must not be exported or re-exported, directly or
indirectly (including via remote access) under the following circumstances:
a. To Cuba, Iran, North Korea, Sudan, or Syria, or any national of these countries.
b. To any person or entity listed on any U.S. government denial list, including but not limited to, the U.S. Department
of Commerce Denied Persons, Entities, and Unverified Lists,
http://www.bis.doc.gov/complianceandenforcement/liststocheck.htm, the U.S. Department of Treasury Specially
Designated Nationals List, http://www.treas.gov/offices/enforcement/ofac/, and the U.S. Department of State
Debarred List, http://www.pmddtc.state.gov/compliance/debar.html.
c. To any entity when Licensee knows, or has reason to know, the end use of the Software Product is related to the
design, development, production, or use of missiles, chemical, biological, or nuclear weapons, or other un-
safeguarded or sensitive nuclear uses.
d. To any entity when Licensee knows, or has reason to know, that an illegal reshipment will take place.
Any questions regarding export or re-export of these Software Products should be addressed to Intergraph Corporation’s
Export Compliance Department, Huntsville, Alabama 35894, USA.
Trademarks
Intergraph®, the Intergraph logo®, Intergraph Smart®, SmartPlant®, SmartMarine, SmartSketch®, SmartPlant Cloud®,
PDS®, FrameWorks®, I-Route, I-Export, ISOGEN®, SPOOLGEN, SupportManager®, SupportModeler®, SAPPHIRE®,
TANK, PV Elite®, CADWorx®, CADWorx DraftPro®, GTSTRUDL®, CAESAR II®, and HxGN SDx® are trademarks or
registered trademarks of Intergraph Corporation or its affiliates, parents, subsidiaries. Hexagon and the Hexagon logo
are registered trademarks of Hexagon AB or its subsidiaries. Other brands and product names are trademarks of their
respective owners.
The following are trademarks and service marks owned by Intergraph Corporation d/b/a Hexagon PPM or its
subsidiaries worldwide: https://hexagonppm.com/trademarks.