! CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
OBSERVE LOCAL PLUMBING AND BUILDING CODES
Recommended Tools & Materials
U S E
Phillips Screwdriver
Channel Lock Pliers Hacksaw Tubing Cutter Tape Measure
Pipe Wrench
Regular Screwdriver
Level
1 2 TABLE
F U T U R E
Provide suitable reinforcement behind
finished wall for lavatory hanger Part # Model Distance "A"
mounting screws. *Determine 0124 Comrade - 2-1/2" (64mm)
horizontal center line location of 0321 Declyn - 2-3/4" (70mm)
support from the table listed in Step 2. Determine the
desired rim height 0355/0356 Lucerne - 1" (25mm)
(Make sure support bottom extends to 0372/0373 Penlyn - 1/8" (3mm)
lavatory back wall bottom.) (for example 32")
then select from the 4867/4869 Regalyn + 2-3/4" (70mm)
NOTE: If replacing an existing sink be Table at right the 9024 Decorum - 3-11/16" (93mm)
certain to shut off water supply before height of the hanger 18-1/4" x 20-1/16"
F O R
C/L OF HANGER ANCHORING SLOTS
EXAMPLE:
C/L of 2 x 8 Hanger HANGER
Support Location For Comrade:
32" - 2-1/2" = 29-1/2" A
S A V E
*
RIM HOLES FOR
HEIGHT ANCHOR SCREWS
IN BACK DRAPERY
*
Finished WASTE SUPPLIES
Floor AS REQUIRED
FINISHED FLOOR
Steel Hanger
Mounting Screw
A
Positioning Screw
7 8 Caulk
Secure lavatory on
Return the fitted lavatory to hanger as shown in 5.
the installed position. Connect Insert and tighten anchor
trap to drain assembly hand screws if applicable.
tight to check alignment. It C Connect hot and cold
may be necessary to cut off supply lines to the
part of the tailpiece (area "B") B shut-off valves. Tighten
or part of the horizontal leg of trap joints for watertight
the trap (area "C"). assembly. Apply a bead
of caulk around the edge Shut-off
which contacts the wall Valves
as shown.