ELECTRICAL STANDARD DETAILS

ELECTRICAL STANDARD DETAILS LIST

SUB-DISCIPLINE VIEW NAME


141 ELECTRICAL SITE MAINTENANCE HOLE DETAIL - 90 DEGREE ROUTING
141 ELECTRICAL SITE MAINTENANCE HOLE DETAIL - STRAIGHT ROUTING

142 ELECTRICAL GROUNDING METAL STACK GROUNDING DETAIL


142 ELECTRICAL GROUNDING PERIMETER GROUND BUS TO EQUIPMENT GROUND BAR CONNECTION

143 ELECTRICAL LIGHTING TYPICAL HIGH BAY LINEAR MOUNTING DETAIL

144 ELECTRICAL POWER 15KV SWITCH BOTTOM ENTRANCE TERMINATION DETAIL


144 ELECTRICAL POWER 36" CABLE TRAY SECTION
144 ELECTRICAL POWER 480 VOLT BOTTOM ENTRANCE TERMINATION DETAIL
144 ELECTRICAL POWER 480 VOLT TOP ENTRANCE TERMINATION DETAIL
144 ELECTRICAL POWER BUILDING OR THERMAL EXPANSION JOINT
144 ELECTRICAL POWER BUSWAY SUPPORT HIGH BAY
144 ELECTRICAL POWER BUSWAY SWAY BRACING DETAIL
144 ELECTRICAL POWER BUSWAY TRAPEZE HANGAR DETAIL
144 ELECTRICAL POWER CABLE TERMINATION DETAIL AT SUBSTATION - BOTTOM ENTRY
144 ELECTRICAL POWER CABLE TRAY AND HANGER ROD CONNECTION TO STRUT CHANNEL DETAIL
144 ELECTRICAL POWER CABLE TRAY ELEVATION CHANGE WITH SPLICE PLATES
144 ELECTRICAL POWER CABLE TRAY VERTICAL DROP SUPPORT ELEVATION
144 ELECTRICAL POWER CENTER CABLE TAP BUS FEEDER CONNECTION DETAIL
144 ELECTRICAL POWER COMPRESSED AIR PRV STATION CONTROL DIAGRAM
144 ELECTRICAL POWER ELECTRICAL LABEL DETAILS
144 ELECTRICAL POWER EXPANSION-THERMAL HANGER DETAIL
144 ELECTRICAL POWER HANGER DETAIL AND NOTES
144 ELECTRICAL POWER INVERTED END TAP BOX
144 ELECTRICAL POWER LEVEL II EV CHARGER POWER DISTRIBUTION DETAIL
144 ELECTRICAL POWER LEVEL II EV CHARGING STATION STANCHION - DOUBLE
144 ELECTRICAL POWER LEVEL III EV CHARGING STATION STANCHION
144 ELECTRICAL POWER PANELBOARD SUPPORT DETAIL
144 ELECTRICAL POWER PRIMARY SELECTIVE KEY INTERLOCK SCHEME
144 ELECTRICAL POWER REMOTE BREAKER CONTROL PANEL
144 ELECTRICAL POWER SPACE REQUIREMENTS FOR ELECTRICAL SERVICES
144 ELECTRICAL POWER TYPICAL 208Y/10V PANEL CONNECTION DIAGRAM
144 ELECTRICAL POWER TYPICAL CABLE TRAY - BUS DUCT ELEVATION CHANGE
144 ELECTRICAL POWER TYPICAL EQUIPMENT PAD AT SUBSTATION
144 ELECTRICAL POWER TYPICAL RECEPTACLE MAIN AND SUB PANEL INSTALLATION DETAIL
144 ELECTRICAL POWER TYPICAL SMOKE EXHAUST FAN CONTROL SCHEMATIC
144 ELECTRICAL POWER TYPICAL SUBSTATION PULLBOX CABLE ENTRY DETAIL
144 ELECTRICAL POWER VERTICAL CABLE TRAY FLOOR PENETRATION SUPPORT
144 ELECTRICAL POWER VERTICAL CABLE TRAY SUPPORT
1'-2"

MAINTENANCE HOLE FRAME

PULLING EYE (TYP) GRP STEP LADDER


WATERPROOF 12" TYPICAL INTERVAL CAST IRON COVER
GRP STEP LADDER 38" DIAMETER X 1 1/2" THICK
12" INTERVAL TYPICAL PULLING EYE (TYPICAL)
FINISHED GRADE
5" CAST IRON COVER
4'-5" 38" DIAMETER X 1 1/2" THICK
SUM PIT 3'-0"

10"
12" X 12" 3'-0" COPPER CLAD GROUND ROD 3/4" X 10'

#4/0 BARE COPPER 3'-2"


GROUND CONDUCTOR COPPER CLAD GROUND ROD 3/4" X 10'

TYPICAL 6" DIAMETER TIE TO NEXT MAINTENANCE HOLE


TIE TO NEXT MAINTENANCE HOLE DUCT BANK - 2X2 GROUNDING ROD
GROUNDING ROD (SEE NOTE 3) (FOR MANUFACTURING ONLY)
1'-6"
2'-4 1/2"

ELECTRIC (FOR MANUFACTURING ONLY)


TOP OF DUCT #4/0 BARE COPPER GROUND CONDUCTOR
3'-0"

(NOTE 1) COPPER GROUND BUS BAR


COPPER GROUND BUS BAR (1/4" X 2" X 2'-0" MINIMUM)
E
OP 4'-5" (1/4" X 2" X 2'-0" MINIMUM)
SL BELL END DUCT WATERPROOF

2"
1'-0"
7 1/2"7 1/2"7 1/2"

CONNECTOR
.

5'-6"
E BELL END DUCT CONNECTOR (TYPICAL) TOP OF DUCT
6'-0"

OP
SL (NOTE 1)
SLOPE

WATERPROOF BOTTOM OF DUCT

1'-0"

(NOTE 1)
(NOTE 1)
3'-0"

.
.

A A SLOPE

1'-2"
1'-2"
5"
1'-9"

TYPICAL 6" DIAMETER


DUCT BANK - 2 X 2
5"

BOTTOM OF DUCT (NOTE 3)


TYPICAL 6" DIAMETER DUCT BANK - 2X2 (NOTE 1)
CABLE RACK (SEE NOTE 3)
TYPICAL CABLE RACK SUMP PIT
(TYPICAL) (12" X 12")
1'-9" 7 1/2"7 1/2"7 1/2" 2'-4 1/2" NOTES:
4" SCHEDULE 40 PVC - ELECTRICAL CONTRACTOR
3'-0" 3'-0" 1. ALL TOP OF DUCT, BOTTOM OF DUCT, AND RELATED DIMENSIONS SHALL BE SHALL COORDINATE WITH CIVIL CONTRACTOR ON INVERT
PROVIDED WITH THE SHOP DRAWINGS. ELEVATION OF MAINTENANCE HOLES. IF THERE IS SUFFICIENT
6'-0" GRADE DRAINING FROM THE MAINTENANCE HOLE,
2. ALL DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS SHALL BE EXTEND 4" CONDUIT TO STORM SEWER. (PREFERRED OPTION)
PROVIDED ON THE SHOP DRAWINGS. SECTION A-A
PLAN VIEW 1/3 CUBIC YARD CRUSHED GRAVEL WITH
3. DUCT BANK SHOWN IS TYPICAL. SEE SITE POWER AND ENLARGED SITE POWER 4" SCHEDULE 40 PVC EXTENDED INTO GRAVEL
PLAN FOR ACTUAL SIZE OF DUCT BANK. (ALTERNATE OPTION IF PREFERRED OPTION
IS NOT FEASIBLE)
4. COORDINATE EXACT MAINTENANCE HOLE LOCATIONS WITH CIVIL DRAWINGS.

5. FOR POWER MAINTENANCE HOLES, PROVIDE ALL SPLICING COMPONENTS AND


FIRE TAPPING AS REQUIRED. CAST IRON COVER SHALL BE LABELED "ELECTRIC-HV".

6. COORDINATE THE DEPTH OF THE DUCT BANK OPENING WITH THE CIVIL
DRAWINGS.

7. FOR COMMUNICATION MAINTENANCE HOLES, PROVIDE INNERDUCT


SLACK/TRANSITION AS DIRECTED BY THE TECHNOLOGY CONSULTANT. CAST IRON
COVER SHALL BE LABELED "COMMUNICATIONS".

8. MAINTENANCE HOLES SHALL BE TWO PIECE WITH TOP PIECE INSTALLED AFTER
CABLES HAVE BEEN PULLED.

MAINTENANCE HOLE DETAIL - 90 DEGREE ROUTING


CAST IRON COVER
38" DIAMETER X 1 1/2" THICK

PULLING EYE (TYPICAL)


FINISHED GRADE MAINTENANCE HOLE FRAME
CAST IRON COVER
38" DIAMETER X 1 1/2" THICK
GRP STEP LADDER
3'-0"
12" TYPICAL INTERVAL 3'-0"

10"
SUMP PIT
COPPER CLAD GROUND ROD TYPICAL
(12" X 12")
3/4" X 10' 3'-2"
TIE TO NEXT MAINTENANCE TIE TO NEXT MAINTENANCE
2"

COPPER GROUND
HOLE GROUNDING ROD HOLE GROUNDING ROD BUS BAR
(FOR MANUFACTURING ONLY) (FOR MANUFACTURING ONLY) 1/4" X 2" X 2'-0"
MINIMUM
ELECTRIC COPPER CLAD GROUND GRP STEP LADDER
#4/0 BARE COPPER ROD 3/4" X 101 12" TYPICAL INTERVAL
GROUND CONDUCTOR
#4/0 BARE COPPER PULLING EYE (TYPICAL)
SL
4'-5"

4'-5"
OP GROUND CONDUCTOR
E
COPPER GROUND BUS BAR

5'-6"
BELL END DUCT
.

1/4" X 2" X 2'-0" MINIMUM BELL END DUCT


WEATHERPROOF CONNECTOR (TYPICAL)
CONNECTOR
PE

SL
S LO

WEATHERPROOF TOP OF DUCT


OP

WATERPROOF WATERPROOF (NOTE1)


E

.
.

B B

N OT E 1
BOTTOM OF DUCT

N OT E 1
.

SLOPE 5" (NOTE)

1'-2"
1'-2"

1'-2"
1'-8"

SLOPE TYPICAL 6" DIAMETER


DUCT BANK - 2 X 2
5"

5"
TYPICAL 6" DIAMETER
DUCT BANK - 2 X 2 (NOTE 3)
(NOTE 3) TYPICAL 6" DIAMETER
DUCT BANK - 2 X 2 SUMP PIT (12" X 12")
(NOTE 3)
2'-4 1/2" 7 1/2"7 1/2"7 1/2" 1'-9" CABLE RACK 4" SCHEDULE 40 PVC - ELECTRICAL CONTRACTOR
(TYPICAL) SHALL COORDINATE WITH CIVIL CONTRACTOR ON INVERT
3'-0" 3'-0" ELEVATION OF MAINTENANCE HOLES. IF THERE IS SUFFICIENT
NOTES: GRADE DRAINING FROM MAINTENANCE HOLE, EXTEND 4"
6'-0" CONDUIT TO STORM SEWER (PREFERRED OPTION)
1. ALL TOP OF DUCT, BOTTOM OF DUCT, AND RELATED DIMENSIONS SHALL BE
PROVIDED WITH THE SHOP DRAWINGS.
1/3 CUBIC YARD CRUSHED GRAVEL WITH
2. ALL DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS SHALL BE SECTION B-B 4" SCHEDULE 40 PVC EXTENDED INTO GRAVEL
PROVIDED ON THE SHOP DRAWINGS. (ALTERNATE OPTION IF PREFERRED OPTION
PLAN VIEW IS NOT FEASIBLE)
3. DUCT BANK SHOWN IS TYPICAL. SEE SITE POWER AND ENLARGED SITE POWER
PLAN FOR ACTUAL SIZE OF DUCT BANK.

4. COORDINATE EXACT MAINTENANCE HOLE LOCATIONS WITH CIVIL DRAWINGS.

5. FOR POWER MAINTENANCE HOLES, PROVIDE ALL SPLICING COMPONENTS AND


FIRE TAPPING AS REQUIRED. CAST IRON COVER SHALL BE LABELED "ELECTRIC-HV".

6. COORDINATE THE DEPTH OF THE DUCT BANK OPENING WITH THE CIVIL
DRAWINGS.

7. FOR COMMUNICATION MAINTENANCE HOLES, PROVIDE INNERDUCT


SLACK/TRANSITION AS DIRECTED BY THE TECHNOLOGY CONSULTANT. CAST IRON
COVER SHALL BE LABELED "COMMUNICATIONS".

8. MAINTENANCE HOLES SHALL BE TWO PIECE WITH TOP PIECE INSTALLED AFTER
CABLES HAVE BEEN PULLED.

MAINTENANCE HOLE DETAIL - STRAIGHT ROUTING


METAL STACK

250KCMIL BARE
COPPER GROUND

3/4" X 10'-0" COPPER CLAD


GROUND ROD (TYPICAL)

250KCMIL BARE
COPPER GROUND

#2 BARE
COPPER GROUND
#2 BARE
REBAR COPPER GROUND

10'-0" MIN
(TYPICAL)

BUILDING STEEL
COLUMN

CADWELD CONNECTION
(TYPICAL)

GENERAL GROUNDING NOTES:

A. GROUND RESISTANCE SHALL NOT EXCEDD 5 OHMS


B. GROUND RODS SHALL BE BURIED A MINIMUM OF 24" BELOW GRADE
C. ALL GROUND ELETRODE CONDUCTORS SHALL BE BURIED A MINIMU, OF 24" BELOW GRADE

METAL STACK GROUNDING DETAIL


EXOTHERMIC CONNECTION
TYPE G3
1/4" x 2" COPPER PERIMETER
GROUND BUS

1/8" x 1" COPPER EQUIPMENT


GROUNDING BAR

3/8"-16 PAN HEAD MACHINE


BOLT, 12" ON CENTER

FIN. FLOOR

SELF-DRILLING TUBULAR
EXPANSION SHIELD
ANCHORS

PERIMETER GROUND BUS


TO EQUIPMENT GROUND
BAR CONNECTION
PRE-MANUFACTURED POWER
"T" ARMOR DROP CONNECTION

CHANNEL STRUT SPRING NUT ROOFPURLIN


WITH JAM NUT ASSEMBLY B-LINE #B760-22J6 OR
B-LINE #B446 FEMALE-MALE EQUAL BEAM CLAMP
SWIVEL HANGER ASSEMBLY B-LINE B22SH
(SEE DETAIL "B")
EXTENDER CABLE
FACTORY CRIMPED LOOP
MODULAR WIRING
TIE-WRAP

STAINLESS STEEL 3/32"


DIAMETER SAFETY ROPE
(OWNER SUPPLIED)
1/2" ZINC PLATED 1. NORMAL LIGHTING FIXTURE TO HAVE
THREADED ROD GREY HOUSING.
2. EMERGENCY LIGHTING FIXTURE TO HAVE
ORANGE COLOR HOUSING AND
CIRCUIT TAG.
GRIPPLE AIRCRFT CABLE ADJUSTER/
3. FIXTURE POSITION SHOWN ON FLOOR
FITTING. INSERT THE GRIPPLE
PLANS ARE NOMINAL LOCATIONS. ALIGN
ADJUSTABLE CABLE INTO THE
FIXTURE LINE-UPS AS BEST AS
ADJUSTER AND ADJUST TO DESIRED
POSSIBLE. AVOID INTERFERENCE WITH
HEIGHT
EXISTING AND NEW OBSTRUCTIONS.
THREAD THE TAIL OF THE SAFETY 4. ALL COMPONENTS ARE TO BE
CABLE THRU FIXTURE FIN CONTRACTOR PROVIDED UNLESS
OTHERWISE NOTED.
FEMALE LOOP LENGTH
AS REQUIRED

LED LIGHT FIXTURE

BOTTOM CHORD
OFTRUSS

0'-1" TPYICAL
STRUT MOUNTS BETWEEN
PURLINS

WRAP GRIPPLE AIRCRAFT CABLE


AROUND STRUT SUPPORT OR
BUILDING STEEL TO SECURE CABLE
WRAP SAFETY CABLE AROUND
STRUT SUPPORT OR BUILDING
STEEL TO SECURE CABLE
10

6
8 5 3

SECURE EXCESS GRIPPLE CABLE TO 4


STEM OF FIXTURE WITH ZIP TIES

THREAD THE TAIL OF THE GRIPPLE


ADJUSTABLE CABLE THRU THE STEM
LOOP AND THEN THRU THE GRIPPLE
CABLE LOOPAND PULL TIGHT SECURE EXCESS GRIPPLE CABLE
TO STEM OF SIXTURE WITH ZIP TIES
INSERT THE GRIPPLE ADJUSTABLE
CABLE INTO THE ADJUSTER AND 5
ADJUST TO DESIRED HEIGHT 2
11
THREAD THE TAIL OF THE GRIPPLE
ADJUSTABLE CABLE THEU THE SELF-
LOCKING CARABINER, THEM CLIP LINK NOTES
HOOK THRU LIGHT FIXTURE HANGER LOOP MARK
NO.
PROVIDE LOOP IN POWER CORD DROP 1 LITHONIA "IBG" LED LUMINAIRE FIXTURE
1 2 FIXTURE HANGER CABLE LOOP
0'-1" TYPICAL

3 GRIPPLE AIRCRAFT CABLE


4 NYLON CABLE TIES
5 GRIPPLE AIRCRAFT SAFETY CABLE
6 10' DROP CORD/CONNECTOR
7 STRUT (EXISTING)
8 STRUT BEAM CLAMP (EXISTING)
9 GRIPPLE AIRCRAFT CABLE ADJUSTER/FITTING
NOTES: 10 1/2' -13 CHANNEL STUD (EXISING)
1. CONTRACTOR TO CONFIRM THERE IS A CARIBINER BETWEEN THE LOOP AND AIRCRAFT CABLE. 11 SELF LOCKING CARABINER

TYPICAL HIGH BAY LINEAR MOUNTING DETAIL


CONCRETE PAD

EXISTING SLAB ON
METAL DECK

X:8"
LUGS

15KV CLASS CABLE


INSULATING SKIRTS RAYCHEM CAT. #HVT-153-G TERMINATION KIT
(QUANTITY AND ORIENTATION PER
MANUFACTURERS RECOMMENDATIONS)

ACCESSIBLE, REMOVABLE
COVER LATES

CABLE SHIELD GROUNDS


(NOTE 2)

GROUND BUS

CABLE CABLE SUPPORT BODY


GROUNDS
OPENING TO SUIT FITTING
BAKELITE WELDING PLUG
ADALET JAG-280-25 OR OTHER
IAC TERMINATOR TO MATCH
LOCK NUT
CABLE DIAMETER (NOTE 3)
CABLE SUPPORT BODY 1/4" STEEL PLATE WITH WELDED SEAMS
ADAPTER TOP OPENING FRAME FOR WATER-TIGHT
DESIGN. HOLES TO BE CUT OUT BY
IAC CLAMP ELECTRICAL CONTRACTOR. (NOTE 3)

NOTES:

1. FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS FOR CABLE TERMINATION.


2. CABLE SHIELDS SHALL BE GROUNDED PER MANUFACTURERS INSTRUCTIONS.
3. PROVIDE 1/8" THICK NEOPRENE GASKET BETWEEN LOCK NUT AND STEELPLATE.

15KV SWITCH BOTTOM ENTRANCE TERMINATION DETAIL


U.V. RESISTANT (BLACK) NYLON
CABLE TIE (TYPICAL). LASH CABLE
TO EVERY 12'-0" FOR HORIZONTAL
RUNS - TY-RAP CABLE TIES SHALL BE
THOMAS AND BETTS DELTEC TYPE OR
APPROVED EQUAL/

INTERLOCKED
ARMOR CABLES

NOTE:
MAXIMUN CABLE TRAY SUPPORT
SHALL BE 10'-0" (TYPICAL)

36" CABLE TRAY SECTION


LUGS

HEAT SHRINK TERMINATION


INSULATING SLEEVE
RAYCHEM CAT. # HVT-Z-153-G
(TYPICAL)

CABLE SHIELD GROUNDS


(NOTE 2)

GROUND BUS

CABLE CABLE SUPPORT BODY


GROUNDS
OPENING TO SUIT FITTING

ADALET JAG-280-25 OR OTHER


IAC TERMINATOR TO MATCH
CABLE DIAMETER (NOTE 3) LOCK NUT

1/4" STEEL PLATE WITH WELDED SEAMS


ADAPTER TOP OPENING FRAME FOR WATER-TIGHT
DESIGN. HOLES TO BE CUT OUT BY
ELECTRICAL CONTRACTOR. (NOTE 3)

NOTES:

1. FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS FOR CABLE TERMINATION.


2. CABLE SHIELDS SHALL BE GROUNDED PER MANUFACTURERS INSTRUCTIONS.
3. PROVIDE 1/8" THICK NEOPRENE GASKET BETWEEN LOCK NUT AND STEELPLATE.

480 VOLT BOTTOM ENTRANCE


TERMINATION DETAIL
OPENING TO SUIT FITTING
ADALET JAG-280-25, ADAPTER
OR OTHER IAC SWITCHGEAR
TERMINATOR TO ENCLOSURE
MATCH CABLE
DIAMETER
(SEE NOTE 3) LOCK NUT

CABLE SUPPORT
BODY
CABLE GROUNDS

GROUND BUS

CABLE SHIELD GROUNDS


(SEE NOTE 2)

HEAT SHRINK TERMINATION


INSULATION SLEEVE
RAYCHEM CAT. #HVT-Z-153-G
(TYPICAL)

LUGS

NOTES:

1. FOLLOW MANUFACTURERS INSTALLATION INSTRUCTIONS FOR CABLE TERMINATION.


2. CABLE SHIELDS SHALL BE GROUNDED PER MANUFACTURERS INSTRUCTIONS.
3. PROVIDE 1/8" THICK NEOPRENE GASKET BETWEEN LOCK NUT AND STEELPLATE.

480 VOLT TOP ENTRANCE


TERMINATION DETAIL
EXPANSION CLAMPS, NUTS,
JOINT BOLTS, AND WASHERS

CHANNEL BUS DUCT

JOINT

PLAN
B-LINE CHANNEL MOUNT CHANNEL
B22SHA BETWEEN ROOF
OURLINS TO SUIT
(NO WELDING ALLOWED)

B-LINE PLATE
B201

NUT, WASHER AND


LOCK WSHER
(TYPICAL)
EXPANSION
JOINT BUS DUCT

BUS DUCT
HANGER

ELEVATION

BUILDING OR THERMAL
EXPANSION JOINT
UNISTRUT P101 (B-LINE B22A) SPRING NUT
OR EQUIVALENT MEMBER WITH MINIMUM ALLOWABLE MOMENT (HOT DIPPED GALVANIZED
CAPACITY = 14,000 LBS (TYPICAL)
@10'-0" OC. MAX PLACED AT PANEL POINTS ON BOX TRUSS

10'-0" 10'-0" 10'-0"

1/2" THREADED
STEEL ROD WITH
NUTS AND WASHERS
(HOT DIPPED
GALAVANIZED - 1/2" THREADED
TYPICAL) STEEL ROD WITH
NUTS AND WASHERS
(HOT DIPPED
GALAVANIZED -
SECONDARY TYPICAL)
STRUCTURAL BOX TRUSS STEEL
SEE STRUCTURAL
DRAWINGS FOR LOCATIONS 1600AMP
AND ADDITIONAL NOTES BUSWAY 1600AMP
AND INFORMATION
BUSWAY
SECONDARY
I-NUT W/LOCK WASHER STEEL
(HOT DIPPED GALVANIZED -
TYPICAL)

DOUBLE NUT W/
LOCKING WASHER MANUFACTURER'S

19'-6" A.F.F.
19'-6" A.F.F.

UNISTRUT SUPPORT UNISTRUT SUPPORT


(HOT DIPPED GALVANIZED - RECOMMENDED
(HOT DIPPED GALVANIZED) (HOT DIPPED GALVANIZED)
TYPICAL) HANGER CLAMP.
OR MANUFACTURED OR MANUFACTURED
(HOT DIPPED
SUPPORT HANGER (TYPICAL) SUPPORT HANGER (TYPICAL)
GALVANIZED - TYPICAL)

FRONT VIEW SIDE VIEW


N.T.S. N.T.S.

CLAMP AND HANGER DETAIL GENERAL NOTES:

1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.

2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.

3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
BUSWAY AND CABLE TRAY. BUSWAY SUPPORT HIGH BAY
4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
CPACITY OF THE HARDWARE SPECIFIED.

5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
WITH THE SET SCREWS,

6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)

7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CLAMP).

9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.


CLAMP AND HANGER DETAIL GENERAL NOTES:
1600 A, 3P BUSWAY "Z" CLAMP BUSWAY TO UNISTRUT; CLAMP MUST
ALLOW BUSWAY TO EPAND LONGITUDINALLY. 1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
B-LINE PLATE B202 BUSWAY SWAY BRACE SECURED TO BOTTOM CHORD SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.
(TYPICAL) OF TRUSS AT 30'-0" ON CENTERS OR WHENEVER
CROSING TRUSS 2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
1/2"-13 HEX HEAD MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.
NUT C/W WASHER
AND LOCK WASHER 3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
(TYPICAL) BUSWAY AND CABLE TRAY.

4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
CPACITY OF THE HARDWARE SPECIFIED.
B-LINE CHANNEL
B22SH 5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
WITH THE SET SCREWS,

6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)
UNISTRUT TO BE SUPPORTED BY BOTTOM CHORD
STRUCTURAL STEEL (TYPICAL) 7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CLAMP).

9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.

BUSWAY SWAY BRACING DETAIL


B-LINE B22SHA BACK SPRING NUT HOT
BEAM CLAMP TO BACK CHANNEL DIPPED GALVANIZED
B-LINE 12 GAUGE HOT DIPPED (TYPICAL)
B441-22A GALVANIZED (TYPICAL)
(TYPICAL) C
L PURLIN C
L PURLIN

CLAMP AND HANGER DETAIL GENERAL NOTES:

1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.
B-LINE
FLAT PLATE 2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
1/2" THREADED STEEL FITTING B202 1/2" HEX HEAD NUT MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.
ROD WITH NUTS AND (TYPICAL) C/W WASHER AND LOCK
LOCK WASHERS (HOT WASHER (HOT DIPPED 3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
DIPPED GALVANIZED - GALVANIZED - TYPICAL) BUSWAY AND CABLE TRAY.
TYPICAL)
4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
1600 AMP CPACITY OF THE HARDWARE SPECIFIED.
BUSWAY MANUFACTURER'S
RECOMMENDED 5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
I-NUT W/LOCK WASHER (HOT HANGER CLAMP. WITH THE SET SCREWS,
DIPPED GALVANIZED - TYPICAL) (HOT DIPPED
GALVANIZED - 6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)
TYPICAL)
7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BOTTOM BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CHORD OF CLAMP).
TRUSS
9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.

DOUBLE NUT W/
LOCKING WASHER
(HOT DIPPED
GALVANIZED - TYPICAL) UNISTRUT SUPPORT
(HOT DIPPED GALVANIZED)
OR MANUFACTURED
SUPPORT HANGER - (TYPICAL)

BUSWAY TRAPEZE HANGAR DETAIL


SUBSTATION LOW
VOLTAGE CABLES SUBSTATION ROOM
INCOMING SECTION FINISH FLOOR
4" EQUIPMENT PAD

ACCESSIBLE REMOVABLE COVER PLATES


SIZE OF COVER PLATE TO BE DETERMINED
BASED ON STRUCTURAL MEMBERS PRESENT
THAT MAY PREVENT ACCESS. COVER PLATES
TO BE DRILLED AND TAPPED. FIELD COORDINATE.

1#4/0 BAE COPPER GRD


WIRE TO PRIMARY
SWITCHGEAR GRD BUS

1/4" THICK STEEL CLOSURE PLATE PROVIDED


BY STRUCTURAL CONTRACTOR TO THE
ELECTRICAL CONTRACTOR. ELECTRICAL
CONTRACTOR SHALL SHIP THE PLATE TO WORK ADALET JAG-280-25
SHOP TO MAKE THE CABLE ENTRY HOLES TO FIT OR OTHER IAC
THE CABLE AND PROVIDE AND INSTALL COVER TERMNATOR TO
PLATES TO PLUG UNUSED CABLE OPENINGS. MATCH CABLE
REFER TO STRUCTURAL DRAWINGS FOR DETAILS. DIAMETER

3/C PLUS GROUND - 750KCMIL


ALUMINUM CABLE - IAC

CABLE TRAY
(TYPICAL)

CABLE TERMINATION DETAIL AT SUBSTATION -


BOTTOM ENTRY
C
L PURLIN B-LINE 1/2"-12 C
L PURLIN
B22SHA ALL SPRING
GAUGE NUT
(TYPICAL) (TYPICAL)

BEAM
CLAMP
B-LINE
B441-22A
(TYPICAL)
B-LINE
FLAT PLATE
FITTING 1/2" HEX
B202 HEAD NUT
(TYPICAL) C/W WASHER
AND LOCK
WASHER
(TYPICAL)

CABLE TRAY B-LINE


B22SH
12 GAUGE
(TYPICAL)
CBLE TRAY
MANUFACTURER'S

1'-0" MIN
RECOMMENDED
INSIDE
6" CABLE TRAY 6"
1'-6"

SECURING
ASSEMBLIES
(TYPICAL) 12"-13
ALL THREADED
6"

ROD (TYPICAL)

1" MAX
1/2"-13 HEX
B-LINE
NUT CW
B22SH
WASHER AND
12 GAUGE
LOCK
(TYPICAL)
1/2"-13 CHANNEL WASHER
STUDS WITH SPRING (TYPICAL)
2-1/8" LONG C/W
HEX HEAD NUT, DOUBLE NUT
WASHER AND LOCK W/LOCK
WASHER WASHER

NOTE:
ALL STRUT AND HANGING SUPPORTS FOR CABLE
TRAYS INCLUDING BUT NOT LIMITED TO: RODS,
NUTS, WASHERS, ETC. SHALL NOT BE DIPPED
GALVANIZE,

CABLE TRAY AND HANGER ROD


CONNECTION TO STRUT CHANNEL DETAIL
SPLICE PLATE CABLE TRAY VERTICALLY
SUPPORTS ADJUSTALE SPLICE
PLATE (TYPICAL)

CABLE TRAY

BONDING JUMPER HORIZONTAL CABLE BONDING JUMPER


(TYPICAL) TRAY BEND (TYPICAL)

CABLE TRAY

NOTE: BONDING JUMPER IS NOT REQUIRED IF SPLICE PLATE IS SIZED


AND INSTALLED PER NEC REQUIREMENTS.

CABLE TRAY ELEVATION


CHANGE WITH SPLICE PLATES
B-LINE
FLAT PLATE
FITTING B202
(TYPICAL) DUAL
CHANNEL
B-LINE
B22SHA
1/2" - HEX
HEAD NUT
C/W WASHER
AND LOCK
WASHER
(TYPICAL)

BEAM CLAMP
B-LINE
B760-22
1/2" - 13
ALL THREADED
ROD (TYPICAL)

VERTICAL HANGER
SPLICE PLATE
B-LINE 9G-8226
(TYPICAL)

DOUBLE NUT
W/ LOCK WASHER

CABLE TRAY VERTICAL


DROP SUPPORT ELEVATION
CABLE LUGS ARMORED CABLE 6" DEEP CABLE
TERMINATIONS LADDER TRAY
BUS DUCT TAP (TYPICAL) (TYPICAL)
(TYPICAL)

CENTERLINE OF
BUS DUCT

FIELD VERIFY ALL


1'-0"
MIN
DIMENSIONS PRIOR
TO INSTALLATION
TO CLEAR ALL
INTERFERENCES BOTTOM CHORD OF
(TYPICAL) TRUSS LINE (TYPICAL)

15'-0" TO 22'-0" (VARIES)


BUS DUCT
LABEL TAP BOX FIELD VERIFY ALL
BUS DUCT CENTER BOTTOM AND SIDES DIMENSIONS PRIOR
CABLE TP BOX WITH SUBSTATON TO INSTALLATION
FEEDER BREAKER TO CLEAR ALL
NUMBER (BUS INTERFERENCES
NUMBER) (TYPICAL) (TYPICAL)

FINISH FLOOR

CENTER CABLE TAP BUS


FEEDER CONNECTION DETAIL
SEQUENCE OF OPERATION

COMPRESSED AIR METER AND PRESSURE REDUCING VALVE (PRV)


2 #12, 1#12 GND IN 3/4" CONDUIT
COMPRESSED AIR METER:
CAT 6 IN 1" CONDUIT
THE LOCAL PLC SHALL MONITOR THE COMPRESSED AIR METER FOR MASS FLOW, TEMPERATURE, PRESSURE, AND ALARMS 2 AMP DI RAIL MOUNTED
ON A CONTINUAL BASIS. THESE VALUES SHALL BE MADE AVAILABLE TO THE LOCAL PLC AND GBMS AT ALL TIMES. AN CIRCUIT BREAKER
3 AMP DIN RAIL MOUNTED
ALARM SHALL BE GENERATED AT THE LOCAL HMI AND GBMS UPON LOSS OF 4-20AmA SIGNAL FROM THE COMPRESSED AIR
CIRCUIT BREAKER 1 AMP DIN RAIL MOUNTED
MASS FLOW METER. THE CONTROLLER SHALL MONITOR AND RECORD COMPRESSED AIR METER READINGS SO AS TO
CIRCUIT BREAKER
PROVIDE A COMPRESSED AIR CONSUMPTION HISTORY. USAGE READINGS SHALL BE RECORDED ON A DAILY, WEEK-TO- 120-230VAC, 24VDC, 10A
DATE, MONTH-TO-DATE, AND YEAR-TO-DATE BASIS. 2 AMP DIN RAIL MOUNTED
DIN RAIL MOUNTED POWER SUPPLY CIRCUIT BREAKER
WITH 10 AMP FUSE
PRV: MOORE INDUSTRIES
30 AMP, 120VAC DIN RAIL MOUNTED HES SINGLE CHANNEL
THE PLC SHALL MONITOR THE PRESSURE UPSTREAM AND DOWNSTREAM OF THE PRV. THE PRV SHALL OPEN AND CLOSE FUSED DISCONNECT SWITCH HART TO ETHERNET GATEWAY
TO MAINTAIN THE PRESSURE SETPOINT (PRESSURE SETPOINT USER ADJUSTABLE AT LOCAL HMI AND GBMS) OF THE PRV. WITH 15 AMP FUSES DIN RAIL MOUNTED
AN ALARM SHALL BE GENERATED AT THE LOCAL HMI AND GBMS FOR THE FOLLOWING:
1 AMP DIN RAIL MOUNTED
• LOW PRESSURE - PRESSURE BELOW PRV IS 5 PSI BELOW SETPOINT CIRCUIT BREAKER
2#`6, 1#16 GND
• HIGH PRESSURE - PRESSURE ABOVE PRV IS 5 PSI ABOVE SETPOINT
24VDC DIN RAIL (TYPICAL)
• PRV FAILURE
2 #6 (IN 3/4" CONDUIT WHERE REQUIRED)
ET200SP CONTROLLER 24VDC
GBMS INTEGRATION:
DIN RAIL MOUNTED HOFFMAN NEMA 12
ALL PRESSURE TRANSDUCERS AND PRVS SHALL BE INTEGRATED INTO THE GBMS. THE PRV SHALL BE CAPABLE OF ENCLOSURE
REMOTE PRESSURE SETPOINT ADJUSTMENT. ALL POINT HISTORIES SHALL BE ENABLED AND SAMPLED AT 30 SECOND
4-20 mA HART SIGNAL OVER
INTERVALS. ALARMS SHALL BE GENERATED AT THE GBMS TO ALERT SITE PERSONNEL OF ABNORMAL OPERATING
BELDEN 8760LS SHIELDED
CONDITIONS.
WITH STEEL ARMOR (PRESSURE)
4-CHANNEL ANALOG OUTPUT 4-20mA HART SIGNAL OVER
MODULE 4-20mA BELDEN 8760LS SHIELDED
WITH STEEL ARMOR (FLOW RATE, TEMPERATURE
HARDWARE POINTS SOFTWARE POINTS 4-CHANNEL ANALOG INPUT PRESSURE, AND ALARM)
POINT NAME MODULE 4-20mA
AI AO BI BO AV BV LOOP SCHED TREND ALARM SHOW ON GRAPHIC
DEMAND X X 4-CHANNEL HART INPUT
SIERRA 640i METER WITH HART PROTOCOL
PEAK MONTH-TO-DATE X X MODULE 4-20mA
AND MASS FLOW RATE, TEMPERATURE,
PEAK WEEK-TO-DATE X X PROGRAMMING PORT AND PRESSURE METERING
PEAK TODAY X X
PEAK YEAR-TO-DATE X X KTP 400 BASIC HMI INTERFACE
USAGE WEEK-TO-DATE X X DOOR MOUNTED
USAGE MONTH-TO-DATE X X 4-20mA SIGNAL OVER UP STREAM PRESSURE TRANSMITTER
USAGE TODAY X X BELDEN 8760 LS SHIELDED ROSEMOUNT 2088 WITH HART PROTOCOL
USAGE YEAR-TO-DATE X X WITH STEEL ARMOR (VALVE CONTROL)
DOWNSTRAM PRESSURE TRANSMITTER
CA METER INSTANTANEOUS FLOW X X X 4-20mA SIGNAL OVER ROSEMOUNT 2088 WITH HART PROTOCOL
CA METER TOTALIZED FLOW X X X BELDEN 8760LS SHIELDED
CA METER TEMPERATURE X X X WITH STEEL ARMOR (VALVE ALARM) DIGITAL VALVE CONTROLLER
CA METER PRESSURE X X X EMERSON DVC6200 WITH INTEGRAL
CA METER FAILURE X X X LIMIT SWITCH
PRESSURE SENSOR UPSTREAM OF PRV X X X NOTES:
PRESSURE SENSOR DOWNSTREAM OF PRV X X X
PRV CONTROL X X X A. PROVIDE ALL COMPONENTS PER FORD STANDARD SPECIFICATIONS FOR THE CONTROL PANEL TO OPERATE PER THE SEQUENCE OF
PRV % OPEN X X OPERATION WHETHER OR NOT INDICATED ON THIS DIAGRAM. COMPONENTS WITHIN POWERTRAIN OPERATIONS PLANTS SHALL COMPLY WITH
LOW PRESSURE ALARM X X X PTS02-121ME CONTROLS HARDWARE SPECIFICATION WITH EXCEPTION OF ALLEN BRADLEY RELAYS AND CONTROL PANELS. COMPONENTS
WITHIN VEHICLE OPERATIONS PLANTS SHALL COMPLY WITH GLOBAL VEHICLE OPERATIONS STRUCTURES STANDARDS SECTION 2 - DESIGN.
HIGH PRESSURE ALARM X X X
PRV FAILURE X X X B. CONTROL PANEL SHALL BE PROVIDED BY LEIDOS. CONTACT BRUCE SODERBERG AT BRUCE.S.SODERBERG@LEIDOS.COM.
TOTALS 6 1 0 0 0 0 0 0 21 4 21
TOTAL HARDWARE (7) TOTAL SOFTWARE (25)

COMPRESSED AIR PRV STATION CONTROL DIAGRAM


"A" AS AS 3"
REQ'D REQ'D
TRP-24/S CP22B
1E-3

TEXT

4"

4"
CONTROL PANEL

1 1/2"
ON BUS TRANSFORMER
POWERED BY 1E-3
DETAIL 1 (BRADY) DETAIL 7 (BRADY)

1 1/2"
DETAIL 12 (PHENOLIC)
"B"
AS
REQ'D AS AS
EQUIPMENT
RP-8/S I.D.
REQ'D REQ'D
277 VOLTS

4"
70-RK1 DO NOT

4"

4"
ON BUS PLUG
DETAIL 2 (BRADY)
ELP3A1-PB USE
SIZE
DEVICE LABEL TYPE LABEL/TEXT COLOR DETAIL DETAIL 8 (BRADY) DETAIL 13 (BRADY)
"A" "B"
AS
EXISTING EQUIPMENT BRADY SIZE TO FIT WHITE/BLACK - REQUIRED
3"
1

EXIT
BUS, BUS PLUGS, BRADY AS REQ'D 4" WHITE/BLACK
13,200 VOLTS

4"
TAP BOXES 2
EF-U18

1 1/2"
CABLE TRAYS BRADY AS REQ'D 4" ORANGE/BLACK 3
DISTRIBUTION
PHENOLIC 3" 1 1/2" WHITE/BLACK
4 DETAIL 3 (BRADY) HVAC MCC#2
PANELS 5
120/277/480 VOLT 6
3" DETAIL 9 (PHENOLIC) ARROWS AS
TRANSFORMER BRADY AS REQ'D 4" WHITE/BLACK 7 INDICATED

SUBSTATIONS PHENOLIC OEM WHITE/BLACK


RP-24/S MOUNTING
3"
ON PLANS
- (TYP.)

1 1/2"
RECEPTACLE PANEL HOLES (typ.)
PULL/TERMINAL BRADY SIZE TO FIT WHITE/BLACK 8 DETAIL 4 (NOTE 6)
BOXES POWERED BY WR2B15U
TRP-24/S WELD

1 1/2"
EXHAUST FANS PHENOLIC 3" 1 1/2" WHITE/BLACK 9
DETAIL 4 (PHENOLIC) RECEPTACLE
WELDING PHENOLIC 3" 1 1/2" WHITE/BLACK 10
RECEPTACLE POWERED BY 1E-3
DETAIL 10 (PHENOLIC)
ISOLATION JOINT PHENOLIC 8" 4" YELLOW/BLACK 11 3"
CONTROL PANELS LP2B1
PHENOLIC 3" 1 1/2" WHITE/BLACK 12
(ALL PANELS) CHAIN
LIGHTING PANEL

1 1/2"
LENGTH AS
POWERED BY REQ'D
BUS PLUG SLOTS BRADY AS REQ'D 4" RED/WHITE 13 1E-3
EXIT PLACARD BRADY OR MIN. 12" MIN. 7 7/8" RED/WHITE 14
SIMILAR DETAIL 5 (PHENOLIC)

3"
ISOLATION

4"
NOTES:

1. BRADY LABELS SINGLE LINE SHALL BE 3" TEXT.


CP2B1 JOINT BACK TO
BACK SIGN
CONTACTOR PANEL TEXT
1 1/2"

8" HEIGHT 1"


2. BRADY LABELS DOUBLE LINE SHALL BE 1.25" TEXT. POWERED BY
LP2B1 DETAIL 11 (PHENOLIC)
3. BRADY LABELS TRIPLE LINE SHALL E .75" TEXT.
DETAIL 6 (PHENOLIC)
4 BRADY LABELS QUAD. LINE SHALL BE .50" TEXT.

5. 3"X1-1/2"" PHENOLIC TAG TEXT HEIGHT SHALL BE .25"

6. EXIT PLACARD SHALL HAVE PLAINLY LEGIBLE LETTERS NOT LESS THAN 8 INCHES HIGH WITH THE PRINCIPAL STROKES OF THE
LETTERS NOT LESS THAN 0.75 INCH WIDE. THE WORD "EXIT" SHALL HAVE LETTERS HAVING A WIDTH NOT LESS THAN 2 INCHES WIDE,
EXCEPT THE LETTER "I" AND THE MINIMUM SPACING BETWEEN LETTERS SHALL NOT BE LESS THAN 0.375 INCH. SIGNS LARGER THAN
THE MINIMUM ESTABLISHED HERE SHALL HAVE THE LETTER WIDTHS, STROKES AND SPACING IN PROPORTION TO THE HEIGHT.

ELECTRICAL LABEL DETAILS


B-LINE B22SHA BACK SPRING NUT HOT
BEAM CLAMP TO BACK CHANNEL DIPPED GALVANIZED
B-LINE 12 GAUGE HOT DIPPED (TYPICAL)
B441-22A GALVANIZED (TYPICAL)
(TYPICAL) C
L PURLIN C
L PURLIN

CLAMP AND HANGER DETAIL GENERAL NOTES:

1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.
B-LINE
FLAT PLATE 2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
1/2" THREADED STEEL FITTING B202 1/2" HEX HEAD NUT MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.
ROD WITH NUTS AND (TYPICAL) C/W WASHER AND LOCK
LOCK WASHERS (HOT WASHER (HOT DIPPED 3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
DIPPED GALVANIZED - GALVANIZED - TYPICAL) BUSWAY AND CABLE TRAY.
TYPICAL)
4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
CAPACITY OF THE HARDWARE SPECIFIED.
MANUFACTURER'S
RECOMMENDED 5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
I-NUT W/LOCK WASHER (HOT HANGER CLAMP. WITH THE SET SCREWS,
DIPPED GALVANIZED - TYPICAL) (HOT DIPPED
GALVANIZED - 6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)
TYPICAL)
7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BOTTOM BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CHORD OF CLAMP).
TRUSS
9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.

DOUBLE NUT W/
LOCKING WASHER
(HOT DIPPED
GALVANIZED - TYPICAL) UNISTRUT SUPPORT
(HOT DIPPED GALVANIZED)
OR MANUFACTURED
SUPPORT HANGER - (TYPICAL)

EXPANSION-THERMAL HANGER DETAIL


B-LINE #B3054 MALLEABLE IRON
BEAM CLAMP (HOT DIPPED
GALVANIZED (TYPICAL)

CLAMP AND HANGER DETAIL GENERAL NOTES:

1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
PURLIN SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.

2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
1/2" THREADED STEEL MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.
ROD WITH NUTS AND
LOCK WASHERS (HOT 3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
DIPPED GALVANIZED - BUSWAY AND CABLE TRAY.
TYPICAL)
4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
1600 AMP CAPACITY OF THE HARDWARE SPECIFIED.
BUSWAY MANUFACTURER'S
RECOMMENDED 5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
I-NUT W/LOCK WASHER (HOT HANGER CLAMP. WITH THE SET SCREWS,
DIPPED GALVANIZED - TYPICAL) (HOT DIPPED
GALVANIZED - 6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)
TYPICAL)
7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BOTTOM BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CHORD OF CLAMP).
TRUSS
9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.

DOUBLE NUT W/
LOCKING WASHER
(HOT DIPPED
GALVANIZED - TYPICAL) UNISTRUT SUPPORT
(HOT DIPPED GALVANIZED)
OR MANUFACTURED
SUPPORT HANGER - (TYPICAL)

HANGER DETAIL AND NOTES


PLUG-IN
BUS

END
TAP
BOX SWAY BRACE

2' MIN
3' MAX

SWAY BRACE
CABLE
TRAY

PLAN
B-LINE CHANNEL MOUNT CHANNEL
B22SHA BETWEEN ROOF
PURLINS TO SUIT
(NO WELDING ALLOWED)

B-LINE PLATE
B202

1/2" - 13 HEX HEAD NUT,


C/W WASHER AND LOCK
PLUG-IN WASHER (TYPICAL)
BUS
ALL 1/2" - 13
END THREADED ROD
TAP
BOX

BUS DUCT
HANGER

ELEVATION

INVERTED END TAP BOX


BREAKER IN UPSTREAM PANEL
TO SERVE EV CHARGER TRANSFORMER

EV CHARGER PANEL MAIN:


BUSSING:
400A BREAKER
400A
P-P VOLTAGE:
P-N VOLTAGE:
208
120
225A-3P FED FROM 1 50kVA TRANSFORMER GROUND BUS: STANDARD PHASE: 3
ELECTRONIC TRIP UNIT ASSUMING A %Z OF 3.5% OR GREATER MOUNTING: SURFACE WIRE: 4
NEUTRAL: 200% MIN SC INTERRUPTING RATING: 14KAIC
3#4/0, 1#4GND
IN 2" CONDUIT REMARKS
LIGHT RECEPT CONT NON C OC PROT CKT O O O CKT OC PROT NON C CONT RECEPT LIGHT
REMARKS
LOAD LOAD LOAD LOAD A B C LOAD LOAD LOAD LOAD
EV CHARGER (LEVEL 2 - 32A) 3328 1 X 2 3328 EV CHARGER (LEVEL 2 - 32A)
2#6, 1#10GRD IN 1" UNDERGROUND CONDUIT
40* 40** 2#1, 1#8GRD IN 1 1/4" UNDERGROUND CONDUIT
3328 3 X 4 3328
EV CHARGER (LEVEL 2 - 32A) 3328 5 X 6 3328 EV CHARGER (LEVEL 2 - 32A)
2#6, 1#10GRD IN 1" UNDERGROUND CONDUIT 40* 40** 2#1, 1#8GRD IN 1 1/4" UNDERGROUND CONDUIT
3328 7 X 8 3328
150KVA, K-13 RATED EV CHARGER (LEVEL 2 - 32A) 3328 9 X 10 3328 EV CHARGER (LEVEL 2 - 32A)
480V-208Y/120V, 3PH, 4W 2#6, 1#10GRD IN 1" UNDERGROUND CONDUIT
40* 40** 2#1, 1#8GRD IN 1 1/4" UNDERGROUND CONDUIT
3328 11 X 12 3328
1#1/0 EV CHARGER (LEVEL 2 - 32A) 3328 13 X 14 3328 EV CHARGER (LEVEL 2 - 32A)
2#6, 1#10GRD IN 1" UNDERGROUND CONDUIT
40* 40** 2#1, 1#8GRD IN 1 1/4" UNDERGROUND CONDUIT
3328 15 X 16 3328
EV CHARGER (LEVEL 2 - 32A) 3328 17 X 18 3328 EV CHARGER (LEVEL 2 - 32A)
2#6, 1#10GRD IN 1" UNDERGROUND CONDUIT
40* 40** 2#1, 1#8GRD IN 1 1/4" UNDERGROUND CONDUIT
5-500KCMIL, 1#3GND 3328 19 X 20 3328
IN 4" CONDUIT (200% NEUTRAL) SPACE 21 X 22 SPACE
SPACE 23 X 24 SPACE
SPACE 25 X 26 SPACE
SPACE 27 X 28 SPACE
SPACE 29 X 30 SPACE

EV CHARGER PANEL
400A, 208Y/120V, 3PH, 4W * REPLACE THE 40A, 2 POLE BREAKER IN THE FUTURE WITH A 60A, 2 POLE BREAKER FOR THE 48A LEVEL 2 EV CHARGERS
30 POLES WITH (10) 40A-2P BREAKERS
(200% NEUTRAL) ** REPLACE THE 40A, 2 POLE BREAKER IN THE FUTURE WITH A 100A, 2 POLE BREAKER FOR THE 80A LEVEL 2 EV CHARGERS

LEVEL II EV CHARGER POWER DISTRIBUTION DETAIL


CAP

1/4"
CAR CHARGER FURNISHED BY OWNER
INSTALLED BY ELECTRICAL CONTRACTOR
(TYPICAL FOR 2)
4"X4"X3/8"
POWDER COATED WEATHERPROOF GFI RECEPTACLE
STEEL POST (WHERE INDICATED)

4'-2"
BOLT COVER
CLAMP GROUNDING BASEPLATE
CONDUCTOR TO CHAMFER
4"

BOLT ASSEMBLY
GRADE
3/4" ANCHOR BOLT
MOUNT CHANNEL (TYPICAL FOR 4)
BETWEEN ROOF
PURLINS TO SUIT
3'-6" MINIMUM

(NO WELDING ALLOWED)


4'-0"

(4) #7 WITH #3 TIES


AT 12" ON CENTER
CONDUIT REINFORCED ROUND
COUPLING CONCRETE BASE

3'-6"
SCHEDULE 80 PVC ROUND

NOTES:

1. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER

2. BOND CONCRETE REINFORCEMENTS SO THAT SYSTEM IS ELECTRICALLY CONTINUOUS

LEVEL II EV CHARGING
STATION STANCHION - DOUBLE
CHAMFER

GRADE
4"

3/4" ANCHOR BOLT


(TYPICAL FOR 4)
3'-6" MINIMUM

(4) #7 WITH #3 TIES


AT 12" ON CENTER
4'-0"

CONDUIT REINFORCED ROUND


COUPLING CONCRETE BASE

3'-6"
ROUND
SCHEDULE 80 PVC

NOTES:

1. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER

2. BOND CONCRETE REINFORCEMENTS SO THAT SYSTEM IS ELECTRICALLY CONTINUOUS

LEVEL III EV CHARGING


STATION STANCHION
UNISTRUT
CHANNEL B-LINE
B22SH (TYPICAL)

UNISTRUT DUAL CHANNEL


CHANNEL B-LINE B-LINE B22SHA
B22SH (TYPICAL)

PANELBOARD
(LP/RP)
CORNER ANGLE WITH HEX BOLTS,
CHANNEL NUTS, LOCK WASHER
UNISTRUT CHANNEL
DUAL CHANNEL B-LINE B22SH
TOP PLAN B-LINE B22SHA (TYPICAL)

HEX BOLT
AND NUT

EXISTING STEEL
PANELBOARD "C" CHANNEL
(LP/RP)
EXISTING SIDING

POST BASE GROUNDING BAR


B-LINE B281SQ
WITH HEX BOLTS,
NUTS, WASHERS
AND ANCHORS

ELEVATION

PANELBOARD SUPPORT DETAIL


6C 6D

K K-RE1852 K-RE1852 K
K K-16642 K-16642
OPEN OPEN
K-18090 K-18090 K

K-16642 K-16642
K-18090 K-18090

K-16642
K-18090

OPEN K-RE1852

SEQUENCE OF OPERATION

Low Voltage Main - Medium Voltage Main 6D -


ꞏClose ꞏClose
ꞏꞏClose either switch 6C or 6D ꞏꞏOpen switch 6C
ꞏꞏInsert key RE1852 ꞏꞏKey RE1852 is captive when switch 6C is open
ꞏꞏClose breaker ꞏꞏKey 16642 is released when switch 6C is open
ꞏꞏKey RE1852 captive when breaker in closed position ꞏꞏRemove key 16642 from switch 6C
ꞏOpen ꞏꞏ6C locked in open position upon removal of key 16642
ꞏꞏOpen breaker ꞏꞏInsert key 16642 into switch 6D
ꞏꞏKey RE1852 now released when breaker in open position ꞏꞏKey RE1852 is captive when switch 6D is open
ꞏꞏRemove key RE1852 ꞏꞏClose switch 6D
Medium Voltage Main 6C - ꞏꞏKey 16642 is captive when switch 6D is closed
ꞏClose ꞏꞏKey 18090 is captive when switch 6D is closed
ꞏꞏOpen switch 6D ꞏꞏKey RE1852 now released when switch 6D is closed
ꞏꞏKey RE1852 is captive when switch 6D is open ꞏꞏRemove key RE1582 from switch 6D
ꞏꞏKey 18090 is released when switch 6D is open ꞏꞏ6D locked in closed position upon removal of key RE1582
ꞏꞏRemove key 18090 from switch 6D ꞏꞏKey RE1582 can now be used to close the Low Voltage Main
ꞏꞏ6D locked in open position upon removal of key 18090 ꞏOpen
ꞏꞏInsert key 18090 into switch 6C ꞏꞏLow Voltage Main open procedure is followed to remove RE1582 from Low Voltage Main
ꞏꞏKey RE1852 is captive when switch 6C is open ꞏꞏInsert key RE1852 into switch 6D
ꞏꞏClose switch 6C ꞏꞏUnlock switch 6D from closed position upon insertion of key RE1582
ꞏꞏKey 18090 is captive when switch 6C is closed ꞏꞏOpen switch 6D
ꞏꞏKey 16642 is captive when switch 6C is closed ꞏꞏKey RE1852 is captive when switch 6D is open
ꞏꞏKey RE1852 now released when switch 6C is closed ꞏꞏKey 16642 is released when switch 6D is open
ꞏꞏRemove key RE1582 ꞏꞏKey 18090 is released when switch 6D is open
ꞏꞏ6C locked in closed position upon removal of key RE1582
ꞏꞏKey RE1582 can now be used to close the Low Voltage Main
ꞏOpen
ꞏꞏLow Voltage Main open procedure is followed to remove RE1582 from Low Voltage Main
ꞏꞏInsert key RE1852 into switch 6C
ꞏꞏUnlock switch 6C from closed position upon insertion of key RE1582
ꞏꞏOpen switch 6C
ꞏꞏKey RE1852 is captive when switch 6C is open
ꞏꞏKey 18090 is released when switch 6C is open
ꞏꞏKey 16642 is released when switch 6C is open

PRIMARY SELECTIVE KEY INTERLOCK SCHEME


BREAKER 6A2 BREAKER 6B2
OPEN CLOSE OPEN CLOSE

OPEN CLOSE OPEN CLOSE

G R G R

BREAKER 6A2 BREAKER 6A3 BREAKER 6A2 BREAKER 6B3 BREAKER 6B


OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE

OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE

G R G R G R G R G R

BREAKER 6A4 BREAKER 6B4


OPEN CLOSE OPEN CLOSE

OPEN CLOSE OPEN CLOSE

G R G R

TO SUBSTATION
BREAKER 6A1 BREAKER 6A5 BREAKER 6B5 BREAKER 6B1
OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE

OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE

G R G R G R G R

NOTES:
1. REMOTE BREAKER CONTROL PANEL FURNISHED BY OWNER AND INSTALLED BY ELECTRICAL TRADES
2. COORDINATE AND VERIFY QUANTITY OF CONDUCTORS WITH MANUFACTURER SHOP DRAWING PRIOR TO INSTALLATION

REMOTE BREAKER CONTROL PANEL


3'-6" MIN FREE SPACE
REQUIRED IN FRONT OF SWITCH

29"

"D" - SEE TABLE


CENTER
TAP BOX
SQUARE D I-LINE 2 SERIES FUSIBLE BUS PLUGS
AMPERAGE HEIGHT DEPTH CLEARANCE WIDTH
RATING "H" "D" W/DOOR OPEN

30 10.25 9.25 24.50 15.25


60 10.25 9.25 24.50 15.25
"H" - SEE TABLE

100 10.25 9.25 29.50 20.25


200 16.75 11.25 33.00 21.75
400 16.75 15.25 41.75 39.25
PLUG-IN 600 16.75 15.25 41.75 39.25
BUS BUS
PLUG

PARALLEL TRUSS COORDINATE PLUG BOTTOM CHORD


TO BUS LOCATIONS WITH OF TRUSS
OTHER CONTRACTS

CLAMP AND HANGER DETAIL GENERAL NOTES:

1. THE MAXIMUM LOAD FOR 3/8" ROD HANGERS SHALL NOT EXCEED 610 LBS. FOR 1/2" RODS THE MAXIMUM LOAD
SHALL NOT EXCEED 1130 LBS. THE RATED SUPPORT CAPACITY OF CLAMPING DEVICES SHALL NOT BE EXCEEDED.

2. USE ONLY 1/2" ROD FOR SUPPORT OF BUSWAY AND CABLE TRAY. FOR BUSWAY USE CLAMPING DEVICES WITH A
MINIMUM OF 700 LBS DESIGN LOAD CAPACITY.

3. USE ONLY CLAMPING DEVICES THAT SPECIFICALLY INDICATE "FOR USE WITH 1/2" ROD" WHEN SUPPORTING
BUSWAY AND CABLE TRAY.

4. ALTERNATES TO SPECIFIED CLAMP HARDWARE SHALL HAVE A CAPACITY GREATER THAN OR EQUAL TO THE
CAPACITY OF THE HARDWARE SPECIFIED.

5. ALL CLAMP HARDWARE THAT USE SET SCREWS AS PART OF THE CLAMPING SYSTEM SHALL INCLUDE JAM NUTS
WITH THE SET SCREWS,

6. CLAMPING DEVICES FOR OUTDOOR USE SHALL BE ZINC COATED (ELECTRO-PLATED OR GALVANIZED.)

7. TIGHTEN CAP NUTS TO MANUFACTURER'S RECOMMENDED TORQUE.

8. ALL CLAMP HARDWARE SHALL BE SUCH THAT VISUAL VERIFICATION OF FULL ROD, BOLT OR SCREW THREADS CAN
BE MADE AFTER INSTALLATION. (I.E. DO NOT USE ITEMS SUCH AS B-LINE B351 C-CLAMP OR UNISTRUT PLC025 FLANGE
CLAMP).

9. FIXTURE MOUNTING DETAIL WHEN CENTERED ON PURLIN OR OTHER BEAM.

SPACE REQUIREMENTS FOR ELECTRICAL SERVICES


45VVA, 480-280Y/120VAC-3PH-4W
100A, 480V, 3PH K-4 RATED TRANSFORMER, COPPER WINDING
480V-3PH. BUS DUCT WIRH 100 AMP FUSES
SQUARE "D" CAT.#EE45T3HCU. FOR MOUNTING
DETAIL SEE THIS DRAWING.
100A
NF FLEXIBLE NON-METALLIC
CONDUIT AS REQUIRED

1 #6 BARE STRANDED 4 1/0 & 1#6 GND, 1-1/2" RGS CONDUIT


COPPER GROUND
3 #2 & 1 #8 GND CADWELDED TO
EQUIPMENT 480V TO
1-1/2" RGS CONDUIT BUILDING STEEL
GROUNDING BUS PLUG
CONDUCTOR A B C DRY TYPE TRANSFORMER
PROVIDE DISCONNECT
WHERE PLUG IS PULL BOX WITH GASKETING
GREATER THAN 50' AND SOLID NEUTRAL SQUARE
FROM TRANSFORMER N
"D" CAT,#MPX815-42

CABLE THROUGH W/COVER


LENGTH AS REQUIRED EQUIPMENT A B C
SQUARE "D" CAT.#MPX866 BONDING JUMPER SYSTEM BONDING JUMPER
TO PANEL GROUND BUS
GROUNDING
RECEPTACLE PANEL NEUTRAL CONDUCTOR
ELECTRODE
208Y/120V-3PH.-4W, 42 CIRCUIT TO PANEL NEUTRAL BUS
CONDUCTOR IN
WITH 150A MAIN CIRCUIT BREAKER TO RECEPTACLE
PVC CONDUIT
SQUARE "D" CAT.#NQ-CW-PANEL INTERIOR, PANELS
BOX, FRONT NQ-CW COLUMN WIDTH
PANELBOARD CONSISTING OF: BUILDING STEEL
BUS: COPPER, SILVER/TIN PLATING
CU. GROUND BAR, TYPE 1 WITH GASKET, INSTALL COPPER BAR WITH
BRANCHES: (42) 20A/1P ECB-G3 COPPER STUB AND THERMO-WELD
SOLID NEUTRAL COLUMN WIDTH CONNECTOR REMOVE NEUTRAL TO COLUMN
CABLE. SEE RECEPTACLE PANEL ON THIS BONDING JUMPER IN
DRAWING FOR TYPICAL MOUNTING AND
INSTALLATION DETAIL
PANEL
TRANSFORMER DELTA-WYE
MAIN PANEL FOR
MOUNTING DETAIL CONNECTION DIAGRAM
SEE THIS DRAWING
(TYPICAL)
TWO 20 AMP, 120 VOLT
HEAVE DUTY DUPLEX
RECEPTACLES WITH
WATERPROOF COVER
SEE DESCRIPTION
(TYPICAL)

TYPICAL 208Y/10V PANEL CONNECTION DIAGRAM


30 DEGREE, 36"
RADIUS VERTICAL
CABLE TRAY OUTSIDE BEND (TYPICAL
SUPPORT (TYPICAL) BOTH SIDES)

30 DEGREE, 36"
RADIUS VERTICAL
INSIDE BEND (TYPICAL
BOTH SIDES)

BOTTOM CHORD OF TRUSS


ELEVATION 18'-0" +/-

TYPICAL CABLE TRAY - BUS


DUCT ELEVATION CHANGE
CL CL

C4 x 5.4
METAL CHANNEL
METAL CHANNEL

2" MIN
(TYPICAL)
METAL CHANNEL
METAL CHANNEL
2" MIN

TYPICAL
3"

2 1/2"
CL

REAR REAR
1 3/8"

CL

48"
H3 X0 H3
X0
HV LV
H2 X3 HV
CL X3 H2 CL
5 4 . 5 " 2'-2 7/16"

X2 METAL CHANNEL X2
H1 H1
X1 X1
CL
METAL CHANNEL
METAL CHANNEL

20"
FRONT FRONT
CL CL
2" MIN

FRONT

TYPICAL
FRONT

2 1/2"
2" MIN

2 /12"
VARIES VARIES VARIES
VARIES VARIES 2'-7 1/2" VARIES

38" VARIES VARIES 38"

VARIES 2" 2"


VARIES 36" 22" 36" 22" 36" 1 1/8"
2" MIN
2" MIN 2" MIN
2" MIN

TYPICAL EQUIPMENT PAD AT SUBSTATION


BUILDING COLUMN
SIZE VARIES

1" MIN
B-LINE B22 SERIES CHANNEL
WITH B-LINE B613 SERIES
COLUMN SUPPORT
CONNECTION TO DOWNSTREAM
CIRCUITS (TYPICAL) ELECTRICAL PANELBOARD, WIRING
TROUGH OR PULL BOX MOUNTED
ON B-LINE STRU WITHIN COLUMN
WEB. (WHERE PANELBOARDS, TROUGHS,
CONNECTION TO DISTRIBUTION AND PULL BOXES CANNOT FIT WITHIN

PER NIC 110B-26A(1)


18"

TRANSFORMER OR MAIN PANEL COLUMN WEB, B-LINE CHANNEL SHALL

3'-0" MINIMUM
BE INSTALLED FLUSH AGAINST STRUCTURAL
MEMBER, SEE DETAIL #1)

PULL BOX WITH GASKETING


AND SOLID NEUTRAL CABLE TROUGH W/COVER
SQUARE "D" CAT.#MPX815-42 LENGTH AS REQUIRED DEPTH AND WIDTH OF
SQUARE "D" CAT.#MTX866 WORKING SPACE REQUIRED
PER THE 2011 NEC

HEIGHT OF WORKING SPACE


SHALL BE FROM FINISHED
A A FLOOR TO A MINIMUM OF
B-LINE MOUNTING 12'-0" A.F.F. PER NIC 110B-26(3)
CHANNEL, SEE SECTION 2'-6" MINIMUM
"A-A" FOR MATERIALS PER NEC 110B-26a(2)
PANELBOARD SHALL BE MOUNTED SO
22"

THAT THE CENTERLINE OF THE MAIN


BREAKER IS 78" ABOVE FINISHED FLOOR

CL
COLUMN MOUNTED PANELBOARD (DOOR REMOVED
FOR CLARITY) 208Y/120V-3PH-4 WIRE, 42 CIRCUIT
WITH 150A MAIN BREAKER SQUARE "D" CAT.#NQ-CW
INTERIOR, BOX, FRONT NQ-CW WIDTH PANELBOARD BUILDING COLUMN
CONSISTING OF: BUS: COPPER, SILVER/TIN PLATING SIZE VARIES
100"

CU. GROUND BAR, TYPE 1 WITH GASKET.


78"

BRANCHES: (42 20A/1P ECB-G3 SOLID NEUTRAL COLUMN


WIDTH CONNECTOR CABLE B-LINE B22 SERIES CHANNEL
12" MIN

WITH B-LINE B613 SERIES


COLUMN SUPPORT

FINISHED FLOOR ELECTRICAL PANELBOARD, WIRING TROUGH


OR PULL BOX MOUNTED ON B-LINE STRUT
TWO 20 AMP, 120 VOLT HEAVY DUTY DUPLEX RECEPTACLES
NEMA 5-20R HOSPITAL GRADE, 2 POLE, 3 WIRE, GROUNDING
DETAIL #1 WITHIN COLUMN WEB

TYPE, MOUNTED IN TWO GANG FD BOX WITH WEATHERPROOF


COVER, BOX MOUNTED BELOW RECEPTACLE PANEL, RECEPTACLES
TO BE PASS AND SEYMOUR CAT.#8300-GRY AND WEATHERPROOF
COVER TO BE PASS AND SEYMOUR CA.#CA22-G OR APPROVED EQUAL

TYPICAL RECEPTACLE MAIN AND SUB PANEL INSTALLATION DETAIL


SAFETY SWITCH NOTES:
WITH 1 N/.O. AND 1 N.C.
30A/NF 1. REPLACE STARTERS FOR ALL EXHAUST FANS AT THEIR EXISTING LOCATION. THESE STARTERS ARE PRESENTLY
AUXILIARY CONTACTS
30AS/30AF WP LOCATED IN THE TRUSS SPACE (BCT). CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION AND SIZE.
FU-4 M1 OL'S
L1 T1 2. REPLACE WIRING AND CONDUIT BETWEEN BUS PLUG AND STARTER ONLY. WIRING BETWEEN THE STARTERS
AND FANS TO REMAIN.
L2 FU-5 M2 T2 EXHAUST 3. FURNISH AND INSTALL CONTROL WIRES IN CONDUIT BETWEEN THE STARTER AND ASSOCIATED AIR HANDLING
FAN MOTOR UNIT (AHU) AS MENTIONED IN NOTE 4 BELOW. WIRE COLORS TO MATCH PER NOTE 5. COORDINATE LOCATION OF
FU-6 M3 480V, 3PH WIRE DROPS IN AHU WITH MECHANICAL CONTRACTOR.
L3 T3 4. THIS EXHAUST FAN IS WIRED TO THE DESIGNATED AIR HANDLING UNIT (AHU) AS INDICATED HERE.
5. WIRE COLORS FOR SIGNALS ARE AS FOLLOWS:
SIZE 1
24 VDC - ORANGE WITH BLUE STRIP
N.I.C. 0 VDC - WHITE WITH BLUE STRIPS
FU-1 FU-2
RUN COMMON FROM PLC (RELAY CONTACT)
480V 120V AC LINE - ORANGE WITH RED STRIPE
120V AC NEUTRAL - WHITE WITH ORANGE STRIPE
H1 H3 H2 H4
6. CONTRACTOR TO VERIFY THE INTEGRITY OF THE WIRING. IF FOUND NOT SUITABLE, THEN THE CONTRACTOR
180-120V SHALL REPLACE THE EXISTING WIRING WITH NEW WIRING. (WIRING BETWEEN STARTER AND MOTOR)
CONTROL XFMR. 7. REFER TO MECHANICAL PLANS FOR THE LOCATION OF ALL AHU AND EXHAUST FANS.
DISC. SW.
100 VA

100 GROUND
FU-3
REMOTE 1. SIZE OF THE STARTER FUSES AND OVERLOADS SHALL BE PER N.E.C.
OFF BMS 2. VERIFY VOLTAGE AND OPERABILITY OF FAN DAMPER ACTUATORS PRIOR TO COMMENCEMENT OF WORK.
SAFETY 3. ELECTRICAL CONTRACTOR SHALL CONFIRM EXHAUST FAN SEQUENCE OF OPERATION AND DAMPER
N.I.C. SWITCH START
MAINT. LOCAL REMOTE STOP O/L CONTROLS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN.
1101 STOP 1102 1103 4. REFER TO POWER PLAN SHEETS FOR INDIVIDUAL FAN LOCATIONS FOR EXACT POWER SOURCE.
110 M MOTOR CONTACTOR 5. 3 AHU PLC INPUTS
OX PB A. MOTOR
START B. OVERLOAD STATUS
120 TS C. LOCAL/REMOTE STATUS
D. FURNISH AND INSTALL 10#14 CONTROL WIRES IN RGS CONDUIT.
6. 3 AHU PLC INPUTS
XO A. START/STOP
M M
BMS B. FURNISH AND INSTALL 4#14 CONTROL WIRES IN RGS CONDUIT
MOTOR
130 RUN

M
O/L
STATUS
140 FIRE ALARM
START

BMS SS N.I.C.
OX LOCAL/REMOTE BMS
STATUS SAFETY
DISC. SW. N.I.C.
SELECTOR

150

SS

N.I.C.
SAFETY
SWITCH
1601 SAFETY
170 A SWITCH
OPEN
100

M
1701
180 G RUNNING

100
O/L AUX.
1801
A O/L TRIP

100

TYPICAL SMOKE EXHAUST FAN CONTROL SCHEMATIC


SWITCHGEAR ABOVE
(TYPICAL)
METAL ENCLOSURE
(TYPICAL) PULLBOX
OPENING 3-1/8" DIA HOLE
REAR REAR (TYPICAL) REAR

METAL ENCLOSURE

6" 3 1 /2 "
(TYPICAL)
11"

11"
6"
2" 2"

5 15/16"
6"

2'-2 15/16"

6"
TYPICAL
6"
6"
2'-10" 2'-10"

6"
6"
4'-7"

4'-7"
6"
15KV PRIMARY SWITCH

3"
2'-3 15/16" 1'-5" 2 1/2" 4" 4" 4" 2 1/2" 15KV PRIMARY SWITCH
6'-0"

MTM
TYPICAL

2" 12'-4" 2"

FRONT FRONT
480V SECTION 480V SECTION 480V SECTION 480V SECTION 480V SECTION
(MAIN AND CIRCUIT BREAKER (CIRCUIT BREAKER (TIE) CIRCUIT BREAKER (MAIN AND CIRCUIT BREAKER
POSITION 1) POSITIONS 2-5) POSITIONS 2-5) POSITION 1)

3'-0" 1'-10" 3'-0" 1'-10" 3'-0"

TYPICAL SUBSTATION PULLBOX CABLE ENTRY DETAIL


CORNER ANGLES WITH
HEX NUT, LOCK WASHER
AND CAP SCREWS

DUAL CHANNEL
B-LINE B22SHA
WIH CONCRETE
ANCHORS

TOP PLAN

VERTICAL
CABLE TRAY

DUAL CHANNEL
B-LINE B22SHA
WITH CONCRETE
ANCHORS

ELEVATION
VERTICAL CABLE TRAY FLOOR
PENETRATION SUPPORT
VERTICAL
CABLE TRAY

VERTICAL
CABLE TRAY

UNISTRUT CHANNEL
B-LINE B22SH (TYPICAL)
DUAL CHANNEL
DUAL CHANNEL B-LINE B22SHA
B-LINE B22SHA (TYPICAL)
(TYPICAL)

CABLE TRAY
HOLD DOWN CLAMP
(TYPICAL)
UNISTRUT CHANNEL B-LINE
B22SH (TYPICAL)
CORNER ANGLE WITH
HEX BOLTS, CHANNEL
NUTS, LOCK WASHER

VERTICAL CABLE TRAY SUPPORT