FIRE PROTECTION

Section 14-07 – FIRE PROTECTION


FIRE PROTECTION
E-190 Cargo Compartment Smoke Detection
• Cargo compartment is increased in capacity, dimension and volume to 22.60 m³
(E170 – 14.33 m³)
• Cargo compartment smoke detection system is fitted with:
- 4 smoke detectors in the FWD cargo compartment
- 3 smoke detectors in the AFT cargo compartment
SMOKE DETECTOR A3
SMOKE DETECTOR A2
SMOKE DETECTOR A1

SMOKE DETECTOR F4

SMOKE DETECTOR F3 B

SMOKE DETECTOR F2

SMOKE DETECTOR F1

A
EMBRAER – Sep12 1
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection

IN THE EVENT OF A FIRE, THE FOLLOWING INDICATIONS WILL BE PROVIDED:

• AURAL WARNING SOUNDS (TRIPLE CHIME)


• MASTER WARNING LIGHTS FLASH
• THE ASSOCIATED CARGO COMPARTMENT EXTINGUISHING BUTTON ILLUMINATES
• EICAS WARNING MESSAGE CRG FWD (AFT) SMOKE IS DISPLAYED

EMBRAER – Sep12 2
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection
E-190 SCHEMATIC DIAGRAM FWD CARGO
FIRE EXTINGUISHER CONTROL PANEL
COMPARTMENT

TEST SMOKE
FAULT DETECTOR
ALARM
F1

SMOKE

FWD DETECTOR ALARM DETECTOR

F2
FWD DETECTOR TEST MAU 1
SMOKE
DETECTOR

F3
SMOKE
DETECTOR

F4

CMC MAU 2

MAU 3

EICAS DISPLAY
EMBRAER – Sep12 3
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection
OPERATION

BOTH RECIRCULATION FANS TURN


OFF IF SMOKE IS DETECTED

EICAS

MASTER WARNING
MASTER CAUTION
MAU 1 MAU 2

ASCB WOW

CMC SPDA 1 SPDA 2 MAU 3

AURAL WARNING

SMOKE SMOKE SMOKE SMOKE CARGO SMOKE SMOKE SMOKE


DETECTOR DETECTOR DETECTOR DETECTOR DETECTOR DETECTOR DETECTOR
OUTFLOW
SOV
FWD CARGO AFT CARGO

CARGO FAN
EMBRAER – Sep12 4
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - Cargo Compartment Smoke Detection

IF SMOKE IS DETECTED:
• BOTH RECIRCULATION FANS TURN OFF
• CARGO VENTILATION FAN STOPS
• VENT OUTFLOW VALVE CLOSES

CRG AFT ACCESS OPEN


DO NOT DISCHARGE EXTINGUISHING BOTTLE INTO THE
BAGGAGE COMPARTMENT

EMBRAER – Sep12 5
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Fire Extinguishing
FIRE EXTINGUISHER
CONTROL PANEL OPERATION

MAU 1
AFT
LOW-RATE CARGO
EICAS DISPLAY BOTTLE COMPARTMENT

MAU 3

FWD
CARGO
MAU 2 HIGH-RATE COMPARTMENT
BOTTLE

EMBRAER – Sep12 6
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lavatory Fire Protection
LAVATORY DETECTORS AND EXTINGUISHERS LOCATION

SENSOR

RESET
FIRE
POWER ON

LAVATORY SMOKE
DETECTOR

LAVATORY
SMOKE
DETECTOR
FIRE
EXTINGUISHER FIRE
BOTTLE EXTINGUISHER
BOTTLE

AFT LAVATORY
FWD LAVATORY
EMBRAER – Sep12 7
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - Pax & Lavatory Fire Protection

SMOKE FIRE
DETECTORS EXTINGUISHERS
LOCATION LOCATION

LAV SMOKE

CABIN SMOKE
EMBRAER – Sep12 8
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - IFE Fire Protection
CABIN SMOKE

IFE RACK SMOKE

RECIRC SMOKE

EMBRAER – Sep12 9
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Landing Gear Bay Fire Detection
BLOCK DIAGRAM

WARN
LH SENSOR
MAU 1
Loop A
LH SENSOR
GENERIC MWS LG BAY FIRE EICAS
I/O 1
Loop B
FIRE BELL

RH SENSOR MAU 2
Loop A
CMC Message will be provided when BOTH
RH SENSOR GENERIC
I/O 3
loops from the same bay detect fire or
Loop B
when one loop is failed and the other
ASCB detects fire

CMC: INFORMATION ABOUT LG BAY FIRE DET FAIL EICAS


WHICH SENSOR IS FAILED BOTH SENSORS FROM THE
SAME BAY ARE FAILED

EMBRAER – Sep12 10