SMOKE DETECTOR F4
SMOKE DETECTOR F3 B
SMOKE DETECTOR F2
SMOKE DETECTOR F1
A
EMBRAER – Sep12 1
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection
EMBRAER – Sep12 2
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection
E-190 SCHEMATIC DIAGRAM FWD CARGO
FIRE EXTINGUISHER CONTROL PANEL
COMPARTMENT
TEST SMOKE
FAULT DETECTOR
ALARM
F1
SMOKE
F2
FWD DETECTOR TEST MAU 1
SMOKE
DETECTOR
F3
SMOKE
DETECTOR
F4
CMC MAU 2
MAU 3
EICAS DISPLAY
EMBRAER – Sep12 3
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Smoke Detection
OPERATION
EICAS
MASTER WARNING
MASTER CAUTION
MAU 1 MAU 2
ASCB WOW
AURAL WARNING
CARGO FAN
EMBRAER – Sep12 4
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - Cargo Compartment Smoke Detection
IF SMOKE IS DETECTED:
• BOTH RECIRCULATION FANS TURN OFF
• CARGO VENTILATION FAN STOPS
• VENT OUTFLOW VALVE CLOSES
EMBRAER – Sep12 5
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Cargo Compartment Fire Extinguishing
FIRE EXTINGUISHER
CONTROL PANEL OPERATION
MAU 1
AFT
LOW-RATE CARGO
EICAS DISPLAY BOTTLE COMPARTMENT
MAU 3
FWD
CARGO
MAU 2 HIGH-RATE COMPARTMENT
BOTTLE
EMBRAER – Sep12 6
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lavatory Fire Protection
LAVATORY DETECTORS AND EXTINGUISHERS LOCATION
SENSOR
RESET
FIRE
POWER ON
LAVATORY SMOKE
DETECTOR
LAVATORY
SMOKE
DETECTOR
FIRE
EXTINGUISHER FIRE
BOTTLE EXTINGUISHER
BOTTLE
AFT LAVATORY
FWD LAVATORY
EMBRAER – Sep12 7
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - Pax & Lavatory Fire Protection
SMOKE FIRE
DETECTORS EXTINGUISHERS
LOCATION LOCATION
LAV SMOKE
CABIN SMOKE
EMBRAER – Sep12 8
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Lineage - IFE Fire Protection
CABIN SMOKE
RECIRC SMOKE
EMBRAER – Sep12 9
Issue: Nov, 2003 Rev.:00
Section 14-07 – FIRE PROTECTION
FIRE PROTECTION
Landing Gear Bay Fire Detection
BLOCK DIAGRAM
WARN
LH SENSOR
MAU 1
Loop A
LH SENSOR
GENERIC MWS LG BAY FIRE EICAS
I/O 1
Loop B
FIRE BELL
RH SENSOR MAU 2
Loop A
CMC Message will be provided when BOTH
RH SENSOR GENERIC
I/O 3
loops from the same bay detect fire or
Loop B
when one loop is failed and the other
ASCB detects fire
EMBRAER – Sep12 10